SPECIFICATION CONTROL DRAWING 202400114 CHEMINAX 120 OHM, AWG 24, RADIO FREQUENCY, 19 STRANDS Date: 8-18-99 OF AWG 36, TWIN CONDUCTOR CABLE Revision: THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200. DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE DESIGNATED. CHARACTERISTIC IMPEDANCE 120 + 10 ohms, Method C at 1 MHz CAPACITANCE - MUTUA . . i CONDUCTORS L 12.5 pF/ft. (nominal) AWG 24, 19 Strands of : ' VELOCITY OF PROPA I 77 AWG 36, Silver-Coated GATION % (nominal) 025 High Strength Copper Alloy 068 DIELECTRICS Rayfoam L Colors - White/ ADDITIONAL REQUIREMENTS Light Blue ELECTRICAL CONDUCTOR RESISTANCE 26.5 ohms/1000 ft. (nominal) INSULATION RESISTANCE 10,000megohms (minimum) for 1000 ft. JACKET FLAWS SPARK TEST 1.0kV (rms), 60 Hz IMPULSE TEST 6.0kV (peak) VOLTAGE WITHSTAND (DIELECTRIC) 1000 volts (rms) (minimum) SHIELD 153 AWG 38 Tin-Coated Copper ENVIRONMENTA AGING STABILITY 135C/-55C/4.50 inch mandrel FLAMMABILITY Method B HEAT SHOCK 228C LOW TEMPERATURE- -5C/4.50 inch mandrel COLD BEND VOLTAGE WITHSTAND (POST ENVIRONMENTAL) 1000 volts (rms), 1 minute JACKET PHYSICAL 47.+ hea Radiation-Crosslinked Modified PVF, INSULATION (DIELECTRIC) (Prior to Cabling) ELONGATION 50% (minimum) TENSILESTRENGTH 1000 Ibf/in? (minimum) JACKET ELONGATION 200% (minimum) TENSILE STRENGTH 4000 Ibf/in? (minimum) JACKET THICKNESS .009 inch (nominal) SHIELD COVERAGE 90% (minimum) Outer jacket will be white (designated by a "-9" appended to the part number, e.g., 202400114-9) unless otherwise specified. Jesignate outer jacket color with a dash number in accordance : with MIL-STD-681. WEIGHT 14.6 Ibs/1000 ft. (nominal) Raychem Corporation THIS SPECIFICATION SHEET TAKES PRECEDENCE aye. ery 300 Constitution Drive OVER DOCUMENTS REFERENCED HERIN. REFERENCE Menlo Park, California 94025 DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT 1-800-2 Raychem Fax: 1-415-361-6297 ON DATE OF INVITATION FOR BiD.