www.recom-power.com REV.: 2/2019 ECO-1
DC/DC Converter
RKZE
Description
The RKZE series are low cost 2W DC/DC converters in a standard SIP7 footprint. This makes them
suitable for price sensitive industrial, test and measurement and high volume applications.
The RKZE converters are pin-compatible with the RK and RH converter series, offering a simple way
to upgrade a 1W high isolation supply to 2W. Standard isolation is 3kVDC with a /H version factory
tested to 4kVDC. The RKZE is available with single or dual outputs with optional continuous short circuit
protection (/P suffix).
Features
Unregulated
Converters
Low cost 2W converter
Industry standard SIP7 package
3kVDC or 4kVDC isolation options
Single or dual outputs
Short circuit protected (/P versions)
IEC/EN62368-1 certified
IEC/EN62368-1 certified
EN55032 compliant
EN55024 compliant
2 Watt
SIP7
Single and Dual
Output
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load
Model Numbering
Selection Guide
Part nom. Input Output Output Efficiency max. Capacitive
Number Voltage Voltage Current typ.
(1) Load
(2)
[VDC] [VDC] [mA] [%] [µF]
RKZE-xx05S (3,4) 5, 12, 15, 24 5 400 81-83 1500
RKZE-xx09S (3,4) 5, 12, 15, 24 9 222 84-85 680
RKZE-xx12S (3,4) 5, 12, 15, 24 12 167 82-88 330
RKZE-xx15S (3,4) 5, 12, 15, 24 15 133 84-86 330
RKZE-xx05D (3,4) 5, 12, 15, 24 ±5 ±200 83-85 ±680
RKZE-xx12D (3,4) 5, 12, 15, 24 ±12 ±84 84-85 ±220
RKZE-xx15D (3,4) 5, 12, 15, 24 ±15 ±66 83-86 ±220
Notes:
Note3: standard part is without suffixes
without suffix, standard isolation voltage (3kVDC/1 second)
add suffix „/H“ for 4kVDC isolation (refer to “Isolation Voltage (6)”)
Note4: add suffix „/P“ for Continuous Short Circuit Protection (refer to “Short Circuit Protection (SCP)”
or add suffix „/HP“ for 4kVDC Isolation and Continuous Short Circuit Protection
Protection (4)
Isolation Option (3)
Single or Dual
nom. Input Voltage
Output Voltage
RKZE-__ __ _/_
Ordering Examples
RKZE-1205S = 12V Input Voltage, 5V Output Voltage, Single Output with 3kVDC Isolation
RKZE-1509S/H = 15V Input Voltage, 9V Output Voltage, Single Output with 4kVDC Isolation
RKZE-0505D/P = 5
V Input Voltage, 5V Output Voltage, Dual Output with 3kVDC Isolation and SCP protection
RKZE-2415D/HP =
24V Input Voltage, 15V Output Voltage, Dual Output with 4kVDC Isolation and SCP protection
www.recom-power.com REV.: 2/2019 ECO-2
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RKZE
Series
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Internal Input Filter capacitor type
Input Voltage Range ±10%
Input Current nom. Vin=
5VDC
12VDC
15VDC
24VDC
500mA
200mA
160mA
100mA
Quiescent Current nom. Vin=
5VDC
12VDC
15VDC
24VDC
30mA
15mA
12mA
7mA
Minimum Load 0%
Start-up Time 10ms
Rise Time 2ms
Internal Operating Frequency 20kHz
Output Ripple and Noise 20MHz BW 75mVp-p 150mVp-p
Efficiency vs. Load
RKZE-0505S RKZE-1205S
RKZE-2412S
RKZE-2405S
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
www.recom-power.com REV.: 2/2019 ECO-3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RKZE
Series
REGULATIONS
Parameter Condition Value
Output Accuracy ±5.0% max.
Line Regulation low line to high line ±1.2% typ. / 1.0% max.
Load Regulation (5) 10% to 100% load 5Vout
9, 12, 15Vout
15% max.
10% max.
Cross Regulation dual output only ±5.0% typ.
Tolerance Envelope
5Vout 9, 12, 15Vout
+15%
+8%
Vnom
+5%
-1%
-5%
Output Voltage [%]
10 50 100
Output Load [%]
Typical Load Line
+10%
+5%
Vnom
+5%
-1%
-5%
Output Voltage [%]
10 50 100
Output Load [%]
Typical Load Line
PROTECTIONS
Parameter Type Value
Short Circuit Protection (SCP) below 100mW, “/P” suffix continuous
Isolation Voltage (6) I/P to O/P
standard part tested for 1 second
rated for 1 minute
3kVDC
1.5kVAC
“/H” suffix tested for 1 second
rated for 1 minute
4kVDC
1.8kVAC
Isolation Resistance 10GW min.
Isolation Capacitance 120pF max.
Leakage Current 0.3µA max.
Insulation Grade functional
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
Notes:
Note5: Operation below 10% load will not harm the converter, but specifications may not be met
www.recom-power.com REV.: 2/2019 ECO-4
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RKZE
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Audio/Video, information and communication technology equipment - Part1: Safety
requirements WD-SE-R-180474-A0 IEC62368-1:2014 2nd Edition
EN62368-1:2014 + AC:2015
RoHS2 RoHS 2011/65/EU + AM2015/863
EMC Compliance Condition Standard / Criterion
Electromagnetic compatibility of multimedia equipment – Emission Requirements with external components EN55032:2015, Class B
Information technology equipment - Radio disturbance characteristics - Limits and
methods of measurement EN55024:2010 + A1:2015
ESD Electrostatic discharge immunity test Air: ±2, 4, 8kV
Contact: ±2, 4kV IEC61000-4-2:2009, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test 3V/m IEC61000-4-3:2006 + A2:2010, Criteria A
Fast Transient and Burst Immunity ±0.5kV IEC61000-4-4:2012, Criteria A
Surge Immunity ±0.5kV IEC61000-4-5:2014 + A1:2017, Criteria B
Immunity to conducted disturbances, induced by radio-frequency fields 3V IEC61000-4-6:2013 + Cor1:2015, Criteria A
Power Magnetic Field Immunity 50Hz, 1A/m IEC61000-4-8:2010, Criteria A
continued on next page
-40 -20 0 20 40 7060-30 -10 10 30 50 80 90
95
110100
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
Derating Graph
(@ Chamber and natural convection 0.1m/s)
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range full load @ natural convection 0.1m/s -40°C to +80°C
Maximum Case Temperature +110°C
Temperature Coefficient ±0.01%/K
Thermal Impedance 0.1m/s, horizontal 46K/W
Operating Altitude 5000m
Operating Humidity non-condensing 5% - 95% RH
MTBF according to MIL-HDBK-217F, G.B. +25°C
+80°C
18300 x 103 hours
8070 x 103 hours
www.recom-power.com REV.: 2/2019 ECO-5
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RKZE
Series
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter Type Value
Material case
potting
black plastic, (UL94V-0)
epoxy, (UL94V-0)
Dimension (LxWxH) 19.65 x 7.05 x 10.20mm
Weight 2.8g typ.
Dimension Drawing (mm)
Recommended Footprint Details
Bottom View
0.5
1.27
10.20
0.5+0.10/-0.05 0.25±0.05
7.05
19.65
embossed Logo
6 x 2.54 =15.24
2.00
12 567
2.54
2.54
4.10
Marking
Top View
12 567
Pin Information
Pin # Single Dual
1 +Vin +Vin
2 -Vin -Vin
5 -Vout -Vout
6 No Pin Com
7 +Vout +Vout
xx.x ± 0.5mm
xx.xx ± 0.25mm
L1
C
1
-Vout
+Vout
-Vin
+Vin
+Vout
+Vin
-Vout
-Vin
L1
C
1
-Vout
+Vout
-Vin
+Vin
+Vout
Com
Com
+Vin
-Vout
-Vin
EMC Filter Suggestion according to EN55032
Component List Class A Component List Class B
MODEL C1
RKZE-2405S, RKZE-1209S
10µF 50VRKZE-0515S
RKZE-2405D, RKZE-0515D
MODEL C1 L1
RKZE-2405S, RKZE-1209S
10µF 50V 12µH choke
RLS-126
RKZE-0515S
RKZE-2405D, RKZE-0515D
Notes:
Note8: Filter suggestions are valid for indicated part numbers only. For other part numbers, please contact RECOM tech support for advice
www.recom-power.com REV.: 2/2019 ECO-6
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RKZE
Series
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimension (LxWxH) tube 520.0 x 16.0 x 9.0mm
Packaging Quantity 25pcs
Storage Temperature Range -55°C to +125°C
Storage Humidity 5% to 95% RH
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.