A-42 Visit www.GemsSensors.com for most current information.
LEVEL SWITCHES – SINGLE POINT
LEDs
R0.1182˝
(R3 mm)
0.1182˝
(3 mm)
0.5910˝
(15 mm)
0.2364˝
(6 mm)
2.2458˝
(57 mm)
1.1820˝
(30 mm)
0.7880˝
(20 mm)
1.7730˝
(45 mm)
Pot
10-48VDC
BRN
BLK BLU
300mA
max
LOAD
10-48VDC
BRN
BLK BLU
300mA
max
LOAD
Fluid Properties Max. Container
Wall Thickness Wet/Dry Sink Part Number
Water Based,
Conductive
(unshielded sensor)
5/8˝
N.O. Wet 230079
N.C. Dry 230081
Non-Water Based,
Not Conductive
(shielded sensor)
3/8˝
N.O. Wet 228830
N.C. Dry 229855
CAP-100 Series – Non-Contact, Capacitive
Level Sensor
For non-metallic containers
Easy external mounting
Compact – 30x45 mm (1.18˝ x 1.77˝)
Potentiometer for sensitivity adjustment
Power on and signal LED indicators
The CAP-100 series offers a unique level sensing solution for a wide variety of bottle
types including plastic, glass and fiberglass. The non-contact sensor is ideally suited
for medical applications such as waste, reagent or diluent liquids as well as dark,
sticky or viscous fluids. The easy-to-calibrate sensor is available in both aqueous and
non-aqueous versions and can be delivered with factory preset sensitivity for quick
installation for OEM orders. The CAP-100 may also be used as a proximity sensor to
detect the presence of solids such as paper or pulp.
Specifications
Performance
Nominal Sensing Distance, Sn 0.39˝ (10mm)
Sensing Range 0-0.39˝ (0-10mm)
Repeat Accuracy - (% of Sn) <10%
Hysteresis - (% of Sn) <20%
Mechanical
Enclosure Ratings IP67, NEMA 1,3,4,6,13
Operating Temperature Range -13°F to +158°F (-25°C to +70°C)
LED Signal Indicator Yellow
Power On LED Indicator Green
Potentiometer Yes
Sensor Type
Unshielded L-Type, Non-Embeddable
Shielded D-Type, Embeddable
Sensor Material Glass Filled Nylon
Cable 78.74˝ (2 meter), 3 Wire PVC
Shock 30g, 11ms
Vibration 55Hz, 1mm amplitude in all planes
Electrical
Supply Voltage 10-48 VDC
Continuous Switching Current 300 mA
Voltage Drop <2 VDC
Current Consumption <10 mA
Switching Frequency 100 Hz
Transient Protection 2kV, 1ms, 1 kOhm
Overload Protection Yes
Short Circuit Yes
Reverse Polarity Protection Yes
Approvals CE
Typical Applications
Fluid Monitoring:
•Waste •Detergent/Wash
•Reagents •Coolant
•Diluent •PrintingInk
Dimensions
How To Order
Select a Part Number based on Fluid Properties and Sink State.
Wiring Diagram
Normally Open Normally Closed