SDAS143C − APRIL 1982 − REVISED AUGUST 1995
Copyright 1995, Texas Instruments Incorporated
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
Package Options Include Plastic
Small-Outline (D) Packages, Ceramic Chip
Carriers (FK), and Standard Plastic (N) and
Ceramic (J) 300-mil DIPs
TYPE
TYPICAL MAXIMUM
CLOCK FREQUENCY
(CL = 50 pF)
(MHz)
TYPICAL POWER
DISSIPATION
PER FLIP-FLOP
(mW)
ALS74A 50 6
AS74A 134 26
description
These devices contain two independent
positive-edge-triggered D-type flip-flops. A low
level at the preset (PRE) or clear (CLR) inputs sets
or resets the outputs regardless of the levels of the
other inputs. When PRE and CLR are inactive
(high), data at the data (D) input meeting the
setup-time requirements are transferred to the
outputs on the positive-going edge of the clock
(CLK) pulse. Clock triggering occurs at a voltage
level and is not directly related to the rise time of
CLK. Following the hold-time interval, data at the
D input can be changed without affecting the
levels at the outputs.
The SN54ALS74A and SN54AS74A are
characterized for operation over the full military
temperature range of −55°C to 125°C. The
SN74ALS74A and SN74AS74A are characterized
for operation from 0°C to 70°C.
FUNCTION TABLE
INPUTS OUTPUTS
PRE CLR CLK D Q Q
L H X X H L
HLXXLH
LLXXH
H
H H HHL
H H LLH
H H L X Q0Q0
The output levels in this configuration are not
specified t o meet the minimum levels for VOH if the
lows at PRE and CLR are near VIL maximum.
Furthermore, this configuration is nonstable; that
is, it does not persist when PRE or CLR returns to
its inactive (high) level.
SN54ALS74A, SN54AS74A ...J PACKAGE
SN74ALS74A, SN74AS74A ...D OR N PACKAGE
(TOP VIEW)
1
2
3
4
5
6
7
14
13
12
11
10
9
8
1CLR
1D
1CLK
1PRE
1Q
1Q
GND
VCC
2CLR
2D
2CLK
2PRE
2Q
2Q
SN54ALS74A, SN54AS74A . . . FK PACKAGE
(TOP VIEW)
3212019
910111213
4
5
6
7
8
18
17
16
15
14
2D
NC
2CLK
NC
2PRE
1CLK
NC
1PRE
NC
1Q
1D
1CLR
NC
2Q
2Q V
2CLR
1Q
NC CC
NC − No internal connection
GND
  !" # $%&" !#  '%()$!" *!"&+
*%$"# $ " #'&$$!"# '& ",& "&#  &-!# #"%&"#
#"!*!* .!!"/+ *%$" '$&##0 *&# " &$&##!)/ $)%*&
"&#"0  !)) '!!&"&#+



SDAS143C − APRIL 1982 − REVISED AUGUST 1995
2POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
logic symbol
S
4
3
1CLK
1D
2
1D
R
1
1Q
5
6
C1
10
11
2CLK 12
2D 13
2Q
9
8
1PRE
2PRE
1CLR
2CLR
1Q
2Q
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Pin numbers shown are for the D, J, and N packages.
logic diagram (positive logic)
PRE
CLR
Q
Q
CLK
D
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, VCC 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, VI 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, TA: SN54ALS74A 55°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74ALS74A 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range 65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.



SDAS143C − APRIL 1982 − REVISED AUGUST 1995
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
recommended operating conditions
SN54ALS74A SN74ALS74A
UNIT
MIN NOM MAX MIN NOM MAX
UNIT
VCC Supply voltage 4.5 5 5.5 4.5 5 5.5 V
VIH High-level input voltage 2 2 V
VIL Low-level input voltage 0.7 0.8 V
IOH High-level output current 0.4 0.4 mA
IOL Low-level output current 4 8 mA
fclock Clock frequency 0 25 0 34 MHz
PRE or CLR low 15 15
t
w
Pulse duration CLK high 17.5 14.5 ns
tw
Pulse duration
CLK low 17.5 14.5
ns
tsu
Setup time before CLK
Data 16 15
ns
tsu Setup time before CLKPRE or CLR inactive 10 10 ns
thHold time after CLKData 2 0 ns
TAOperating free-air temperature −55 125 0 70 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
SN54ALS74A SN74ALS74A
UNIT
PARAMETER
TEST CONDITIONS
MIN TYPMAX MIN TYPMAX
UNIT
VIK VCC = 4.5 V, II = −18 mA −1.5 −1.5 V
VOH VCC = 4.5 V to 5.5 V, IOH = −2 mA VCC−2 VCC−2 V
VOL
VCC = 4.5 V
IOL = 4 mA 0.25 0.4 0.25 0.4
V
VOL VCC = 4.5 V IOL = 8 mA 0.35 0.5 V
II
CLK or D
VCC = 4.5 V,
VI = 7 V
0.1 0.1
mA
IIPRE or CLR VCC = 4.5 V, VI = 7 V 0.2 0.2 mA
IIH
CLK or D
VCC = 4.5 V,
VI = 2.7 V
20 20
A
IIH PRE or CLR VCC = 4.5 V, VI = 2.7 V 40 40 µA
IIL
CLK or D
VCC = 4.5 V,
VI = 0.4 V
0.2 0.2
mA
IIL PRE or CLR VCC = 4.5 V, VI = 0.4 V 0.4 0.4 mA
IOVCC = 5.5 V, VO = 2.25 V −20 −112 −30 −112 mA
ICC VCC = 5.5 V, See Note 1 2.4 4 2.4 4 mA
All typical values are at VCC = 5 V, TA = 25°C.
The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
NOTE 1: ICC is measured with D, CLK, and PRE grounded, then with D, CLK, and CLR grounded.



SDAS143C − APRIL 1982 − REVISED AUGUST 1995
4POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
switching characteristics (see Figure 1)
PARAMETER FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
RL = 500 ,
TA = MIN to MAXUNIT
PARAMETER
(INPUT)
(OUTPUT)
SN54ALS74A SN74ALS74A
UNIT
MIN MAX MIN MAX
fmax 25 34 MHz
tPLH
PRE or CLR
Q or Q
3 18 3 13
ns
tPHL PRE or CLR Q or Q 5 17 5 15 ns
tPLH
CLK
Q or Q
5 23 5 16
ns
tPHL
CLK
Q or Q
5 20 5 18
ns
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, VCC 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, VI 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, TA: SN54AS74A 55°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN74AS74A 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range 65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54AS74A SN74AS74A
UNIT
MIN NOM MAX MIN NOM MAX
UNIT
VCC Supply voltage 4.5 5 5.5 4.5 5 5.5 V
VIH High-level input voltage 2 2 V
VIL Low-level input voltage 0.8 0.8 V
IOH High-level output current −2 −2 mA
IOL Low-level output current 20 20 mA
fclock*Clock frequency 0 90 0 105 MHz
PRE or CLR low 4 4
t
w
*Pulse duration CLK high 4 4 ns
tw*
Pulse duration
CLK low 5.5 5.5
ns
tsu*
Setup time before CLK
Data 4.5 4.5
ns
tsu*Setup time before CLKPRE or CLR inactive 2 2 ns
th*Hold time after CLKData 0 0 ns
TAOperating free-air temperature −55 125 0 70 °C
* On products compliant to MIL-STD-833, Class B, this parameter is based on characterization data but is not production tested.



SDAS143C − APRIL 1982 − REVISED AUGUST 1995
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
SN54AS74A SN74AS74A
UNIT
PARAMETER
TEST CONDITIONS
MIN TYPMAX MIN TYPMAX
UNIT
VIK VCC = 4.5 V, II = −18 mA −1.2 −1.2 V
VOH VCC = 4.5 V to 5.5 V, IOH = −2 mA VCC−2 VCC−2 V
VOL VCC = 4.5 V, IOL = 20 mA 0.25 0.5 0.25 0.5 V
IIVCC = 5.5 V, VI = 7 V 0.1 0.1 mA
IIH
CLK or D
VCC = 5.5 V,
VI = 2.7 V
20 20
A
IIH PRE or CLR VCC = 5.5 V, VI = 2.7 V 40 40 µA
IIL
CLK or D
VCC = 5.5 V,
VI = 0.4 V
0.5 0.5
mA
IIL PRE or CLR VCC = 5.5 V, VI = 0.4 V −1.8 −1.8 mA
IOVCC = 5.5 V, VO = 2.25 V −30 −112 −30 −112 mA
ICC VCC = 5.5 V, See Note 1 10.5 16 10.5 16 mA
All typical values are at VCC = 5 V, TA = 25°C.
The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
NOTE 1: ICC is measured with D, CLK, and PRE grounded, then with D, CLK, and CLR grounded.
switching characteristics (see Figure 1)
PARAMETER FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
RL = 500 ,
TA = MIN to MAX§UNIT
PARAMETER
(INPUT)
(OUTPUT)
SN54AS74A SN74AS74A
UNIT
MIN MAX MIN MAX
fmax* 90 105 MHz
tPLH
PRE or CLR
Q or Q
2 9 2 7.5
ns
tPHL PRE or CLR Q or Q 2.5 11.5 2.5 10.5 ns
tPLH
CLK
Q or Q
2.5 10 3 8
ns
tPHL
CLK
Q or Q
3.5 10.5 3 9
ns
* On products compliant to MIL-STD-833, Class B, this parameter is based on characterization data but is not production tested.
§For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.



SDAS143C − APRIL 1982 − REVISED AUGUST 1995
6POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
PARAMETER MEASUREMENT INFORMATION
SERIES 54ALS/74ALS AND 54AS/74AS DEVICES
tPHZ
tPLZ
tPHL tPLH
0.3 V
tPZL
tPZH
tPLH tPHL
LOAD CIRCUIT
FOR 3-STATE OUTPUTS
From Output
Under Test Test
Point
R1
S1
CL
(see Note A)
1.3 V
1.3 V1.3 V
3.5 V
3.5 V
0.3 V
0.3 V
th
tsu
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
Timing
Input
Data
Input
1.3 V 1.3 V 3.5 V
3.5 V
0.3 V
0.3 V
High-Level
Pulse
Low-Level
Pulse
tw
VOLTAGE WAVEFORMS
PULSE DURATIONS
Input
Out-of-Phase
Output
(see Note C)
1.3 V 1.3 V
1.3 V1.3 V
1.3 V 1.3 V
1.3 V1.3 V
1.3 V
1.3 V
3.5 V
3.5 V
0.3 V
0.3 V
VOL
VOH
VOH
VOL
Output
Control
(low-level
enabling)
Waveform 1
S1 Closed
(see Note B)
Waveform 2
S1 Open
(see Note B) [0 V
VOH
VOL
[3.5 V
In-Phase
Output
0.3 V
1.3 V 1.3 V
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS
R2
VCC
RL
Test
Point
From Output
Under Test
CL
(see Note A)
LOAD CIRCUIT
FOR OPEN-COLLECTOR OUTPUTS
LOAD CIRCUIT FOR
BI-STATE
TOTEM-POLE OUTPUTS
From Output
Under Test Test
Point
CL
(see Note A) RL
RL = R1 = R2
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. When measuring propagation delay items of 3-state outputs, switch S1 is open.
D. All input pulses have the following characteristics: PRR 1 MHz, tr = tf = 2 ns, duty cycle = 50%.
E. The outputs are measured one at a time with one transition per measurement.
Figure 1. Load Circuits and Voltage Waveforms
PACKAGE OPTION ADDENDUM
www.ti.com 5-Sep-2011
Addendum-Page 1
PACKAGING INFORMATION
Orderable Device Status (1) Package Type Package
Drawing Pins Package Qty Eco Plan (2) Lead/
Ball Finish MSL Peak Temp (3) Samples
(Requires Login)
5962-9862701Q2A ACTIVE LCCC FK 20 1 TBD Call TI Call TI
5962-9862701QCA ACTIVE CDIP J 14 1 TBD Call TI Call TI
84011012A ACTIVE LCCC FK 20 1 TBD Call TI Call TI
8401101CA ACTIVE CDIP J 14 1 TBD Call TI Call TI
8401101DA ACTIVE CFP W 14 1 TBD Call TI Call TI
JM38510/37101B2A ACTIVE LCCC FK 20 1 TBD POST-PLATE N / A for Pkg Type
JM38510/37101BCA ACTIVE CDIP J 14 1 TBD A42 N / A for Pkg Type
SN54ALS74AJ ACTIVE CDIP J 14 1 TBD A42 N / A for Pkg Type
SN54AS74AJ ACTIVE CDIP J 14 1 TBD A42 N / A for Pkg Type
SN74ALS74AD ACTIVE SOIC D 14 50 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
SN74ALS74ADE4 ACTIVE SOIC D 14 50 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
SN74ALS74ADG4 ACTIVE SOIC D 14 50 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
SN74ALS74ADR ACTIVE SOIC D 14 2500 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
SN74ALS74ADRE4 ACTIVE SOIC D 14 2500 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
SN74ALS74ADRG4 ACTIVE SOIC D 14 2500 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
SN74ALS74AJ OBSOLETE CDIP J 14 TBD Call TI Call TI
SN74ALS74AN ACTIVE PDIP N 14 25 Pb-Free (RoHS) CU NIPDAU N / A for Pkg Type
SN74ALS74AN3 OBSOLETE PDIP N 14 TBD Call TI Call TI
SN74ALS74ANE4 ACTIVE PDIP N 14 25 Pb-Free (RoHS) CU NIPDAU N / A for Pkg Type
SN74ALS74ANSR ACTIVE SO NS 14 2000 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
SN74ALS74ANSRE4 ACTIVE SO NS 14 2000 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
SN74ALS74ANSRG4 ACTIVE SO NS 14 2000 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
PACKAGE OPTION ADDENDUM
www.ti.com 5-Sep-2011
Addendum-Page 2
Orderable Device Status (1) Package Type Package
Drawing Pins Package Qty Eco Plan (2) Lead/
Ball Finish MSL Peak Temp (3) Samples
(Requires Login)
SN74AS74AD ACTIVE SOIC D 14 50 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
SN74AS74ADE4 ACTIVE SOIC D 14 50 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
SN74AS74ADG4 ACTIVE SOIC D 14 50 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
SN74AS74ADR ACTIVE SOIC D 14 2500 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
SN74AS74ADRE4 ACTIVE SOIC D 14 2500 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
SN74AS74ADRG4 ACTIVE SOIC D 14 2500 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
SN74AS74AN ACTIVE PDIP N 14 25 Pb-Free (RoHS) CU NIPDAU N / A for Pkg Type
SN74AS74ANE4 ACTIVE PDIP N 14 25 Pb-Free (RoHS) CU NIPDAU N / A for Pkg Type
SN74AS74ANSR ACTIVE SO NS 14 2000 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
SN74AS74ANSRE4 ACTIVE SO NS 14 2000 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
SN74AS74ANSRG4 ACTIVE SO NS 14 2000 Green (RoHS
& no Sb/Br) CU NIPDAU Level-1-260C-UNLIM
SNJ54ALS74AFK ACTIVE LCCC FK 20 1 TBD POST-PLATE N / A for Pkg Type
SNJ54ALS74AJ ACTIVE CDIP J 14 1 TBD A42 N / A for Pkg Type
SNJ54ALS74AW ACTIVE CFP W 14 1 TBD A42 N / A for Pkg Type
SNJ54AS74AFK ACTIVE LCCC FK 20 1 TBD POST-PLATE N / A for Pkg Type
SNJ54AS74AJ ACTIVE CDIP J 14 1 TBD A42 N / A for Pkg Type
(1) The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
PACKAGE OPTION ADDENDUM
www.ti.com 5-Sep-2011
Addendum-Page 3
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
OTHER QUALIFIED VERSIONS OF SN54ALS74A, SN54AS74A, SN74ALS74A, SN74AS74A :
Catalog: SN74ALS74A, SN74AS74A
Military: SN54ALS74A, SN54AS74A
NOTE: Qualified Version Definitions:
Catalog - TI's standard catalog product
Military - QML certified for Military and Defense Applications
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device Package
Type Package
Drawing Pins SPQ Reel
Diameter
(mm)
Reel
Width
W1 (mm)
A0 (mm) B0 (mm) K0 (mm) P1
(mm) W
(mm) Pin1
Quadrant
SN74ALS74ADR SOIC D 14 2500 330.0 16.4 6.5 9.0 2.1 8.0 16.0 Q1
SN74ALS74ANSR SO NS 14 2000 330.0 16.4 8.2 10.5 2.5 12.0 16.0 Q1
SN74AS74ADR SOIC D 14 2500 330.0 16.4 6.5 9.0 2.1 8.0 16.0 Q1
SN74AS74ANSR SO NS 14 2000 330.0 16.4 8.2 10.5 2.5 12.0 16.0 Q1
PACKAGE MATERIALS INFORMATION
www.ti.com 11-Mar-2008
Pack Materials-Page 1
*All dimensions are nominal
Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm)
SN74ALS74ADR SOIC D 14 2500 346.0 346.0 33.0
SN74ALS74ANSR SO NS 14 2000 346.0 346.0 33.0
SN74AS74ADR SOIC D 14 2500 346.0 346.0 33.0
SN74AS74ANSR SO NS 14 2000 346.0 346.0 33.0
PACKAGE MATERIALS INFORMATION
www.ti.com 11-Mar-2008
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TIs terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TIs standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic."Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products Applications
Audio www.ti.com/audio Communications and Telecom www.ti.com/communications
Amplifiers amplifier.ti.com Computers and Peripherals www.ti.com/computers
Data Converters dataconverter.ti.com Consumer Electronics www.ti.com/consumer-apps
DLP®Products www.dlp.com Energy and Lighting www.ti.com/energy
DSP dsp.ti.com Industrial www.ti.com/industrial
Clocks and Timers www.ti.com/clocks Medical www.ti.com/medical
Interface interface.ti.com Security www.ti.com/security
Logic logic.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense
Power Mgmt power.ti.com Transportation and Automotive www.ti.com/automotive
Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video
RFID www.ti-rfid.com
OMAP Mobile Processors www.ti.com/omap
Wireless Connctivity www.ti.com/wirelessconnectivity
TI E2E Community Home Page e2e.ti.com
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright ©2011, Texas Instruments Incorporated