7526A Precision Process Calibrator Extended specifications Specifications General Specifications Warm-up Time ................................... Twice the time since last warmed up, to a maximum of 30 minutes Settling Time ...................................... Less than 5 seconds for all functions and ranges except as noted Standard Interfaces ............................ RS-232 IEEE-488 (GPIB) Temperature Performance Operating ..................................... 0 C to 50 C Calibration (tcal) ......................... 18 C to 28 C Storage......................................... -20 C to 70 C Temperature Coefficient .................... Temperature coefficient for temperatures outside tcal 5 C is 10 % of the 90day specification (or 1 year if applicable) per C Relative Humidity Operating ..................................... <80 % to 30 C <70 % to 40 C <40 % to 50 C Altitude Operating ....................................... 3,000 m (9,800 ft) maximum Non-operating ................................ 12,200 m (40,000 ft) maximum rd Safety ................................................. EN/IEC 61010-1:2010 3 Edition, UL 61010-1:2012, CAN/CSA 22.2 No. 61010-1-12 EMC ..................................................... Complies with EN/IEC 61326-1:2006, EN 61326-2-1:2006 for controlled EM environments except when used in the following conditions: In electromagnetic fields from 0.08-2.7 GHz in excess of 1V/m. When subjected to electrostatic discharge (ESD) to the binding posts. Good static awareness practices should be followed when handling this product such as discharging any built up static charge to the product chassis prior to handling terminals or test connections. When the product is used with data I/O cables in excess of 3 m. Analog Low Isolation ......................... 20 V Line Power Line Voltage (selectable) 120 V~ ............................................... 100 V to 120 V 240 V~ ................................................ 220 V to 240 V Line Frequency ................................... 47 to 63 Hz Line Voltage Variation ....................... 10 % about setting Power Consumption .......................... 15 VA maximum Dimensions Height .......................................... 14.6 cm (5.75 inch) Width ........................................... 44.5 cm (17.5 inch) Depth ........................................... 29.8 cm (11.75 inch) overall Weight (without options) ................... 4.24 kg (9.35 lb) 2 Fluke Calibration 7526A Precision Process Calibrator Extended Specifications DC Voltage Specifications, Output Ranges Absolute Uncertainty, tcal 5C, (ppm of output +V) [1] 90 Days 1 Year 0 mV to 100.000 mV 0 V to 1.00000 V 0 V to 10.0000 V 0 V to 100.000 V 25 25 25 25 3 10 100 1 mV -10 to 75.000 mV 25 2 V 30 3 30 10 30 100 30 1 mV TC Output and 30 2 V [1] All outputs are positive only, unless otherwise noted. [2] Remote sensing is not provided. Output resistance is <1 Stability 24 hours, 1 C (ppm of output +V) 5 ppm + 2 V 4 ppm + 10 V 4 ppm + 100 V 5 ppm + 1 mV Input 5 ppm + 2 V Noise Bandwidth 0.1 to 10 Hz p-p (ppm of output +V) 1 V 10 V 100 V 10 ppm+1 mV Ranges 0 mV to 100.000 mV 0 V to 1.00000 V 0 V to 10.0000 V 0 V to 100.000 V Resolution Maximum [2] Burden 1 V 10 V 100 V 1 mV 10 mA 10 mA 10 mA 1 mA 1 V 10 Bandwidth 10 Hz to 10 kHz rms V 6 V 60 V 600 V 20 mV DC Voltage Specifications, Isolated Input Absolute Uncertainty, tcal 5 C, (ppm of reading + mV) 50 0.2 50 2.0 Ranges 0 V to 10.0000 V 0 V to 100.000 V Resolution 100 V 1 mV DC Current Specifications, Output Ranges [1] 0 mA to 100.000 mA Absolute Uncertainty, tcal 5 C, (ppm of output + A) 90 Days 1 Year [2] [2] 40 1 50 1 [1] All outputs are positive only. [2] For line voltages less than 95 V (100 ppm of reading) Resolution Maximum Compliance Voltage Maximum Inductive Load 1 A 12 V 100 mH Noise Ranges Bandwidth 10 Hz to 10 kHz rms V 20 A Bandwidth 0.1 to 10 Hz p-p 2000 nA 0 mA to 100.000 mA DC Current Specifications, Isolated Input Absolute Uncertainty, tcal 5 C, (ppm of reading + A) Ranges 0 mA to 50.0000 mA 0 mA to 24.0000 mA (Loop Power) [1] Loop Power: 24 V 10 % [2] HART Resistor: 250 3 % [1][2] 100 100 1 1 Resolution 0.1 A 0.1 A Resistance Specifications, Output Ranges 5 to 400.000 5 to 4.00000 k [1] Absolute Uncertainty, tcal 5 C, Ohms 90 Days 1 Year 0.012 0.015 0.25 0.3 Resolution 0.001 0.01 Nominal Current [1] 1 to 3 mA 100 A to 1 mA For currents lower than shown, the specification becomes New Spec. = Stated Spec. x Imin/Iactual. For example, a 500 A stimulus that measures 100 has a specification of: 0.015 x 1 mA/500 A=0.03 3 Fluke Calibration 7526A Precision Process Calibrator Extended Specifications Resistance Specifications, Input Absolute Uncertainty, tcal 5 C (ppm of reading + ) 90 Days 1 Year 0 to 400.000 20 ppm + 0.0035 20 ppm + 0.004 0 k to 4.00000 k 20 ppm + 0.035 20 ppm + 0.04 Ranges Resolution Stimulus Current 0.001 0.01 1 mA 0.1 mA Thermocouple Specification, Output and Input TC Type Minimum B C E J K L N R S Absolute Uncertainty, tcal 5 C, (C) Range (C) Output/Input Maximum 90 days 1 Year 600 C 800 C 1550 C 800 C 1550 C 1820 C 0.35 C 0.28 C 0.21 C 0.35 C 0.28 C 0.22 C 0 C 1000 C 1800 C 2000 C 1000 C 1800 C 2000 C 2316 C 0.15 C 0.22 C 0.24 C 0.32 C 0.16 C 0.23 C 0.26 C 0.35 C -250 C -200 C -100 C 0 C 600 C -200 C -100 C 0 C 600 C 1000 C 0.24 C 0.10 C 0.07 C 0.06 C 0.08 C 0.25 C 0.12 C 0.09 C 0.08 C 0.10 C -210 C -100 C 800 C -100 C 800 C 1200 C 0.13 C 0.07 C 0.08 C 0.14 C 0.09 C 0.10 C -250 C -200 C -100 C 500 C 800 C -200 C -100 C 500 C 800 C 1372 C 0.45 C 0.15 C 0.08 C 0.09 C 0.11 C 0.46 C 0.16 C 0.10 C 0.10 C 0.13 C -200 C -100 C -100 C 900 C 0.08 C 0.07 C 0.10 C 0.09 C -250 C -200 C -100 C 0 C 100 C 800 C -200 C -100 C 0 C 100 C 800 C 1300 C 0.72 C 0.22 C 0.11 C 0.09 C 0.08 C 0.10 C 0.73 C 0.23 C 0.12 C 0.11 C 0.10 C 0.12 C -50 C -25 C 0 C 100 C 400 C 600 C 1000 C 1600 C -25 C 0 C 100 C 400 C 600 C 1000 C 1600 C 1767 C 0.54 C 0.44 C 0.38 C 0.27 C 0.21 C 0.19 C 0.18 C 0.21 C 0.55 C 0.45 C 0.39 C 0.28 C 0.22 C 0.21 C 0.19 C 0.23 C -50 C -25 C 0 C 100 C 400 C 600 C 1000 C 1600 C -25 C 0 C 100 C 400 C 600 C 1000 C 1600 C 1767 C 0.51 C 0.43 C 0.37 C 0.28 C 0.22 C 0.21 C 0.20 C 0.24 C 0.51 C 0.43 C 0.38 C 0.29 C 0.23 C 0.22 C 0.22 C 0.26 C 4 Fluke Calibration 7526A Precision Process Calibrator Extended Specifications [1] R S T U XK BP [1] -50 C -25 C 0 C 100 C 400 C 600 C 1000 C 1600 C -25 C 0 C 100 C 400 C 600 C 1000 C 1600 C 1767 C 0.54 C 0.44 C 0.38 C 0.27 C 0.21 C 0.19 C 0.18 C 0.21 C 0.55 C 0.45 C 0.39 C 0.28 C 0.22 C 0.21 C 0.19 C 0.23 C -50 C -25 C 0 C 100 C 400 C 600 C 1000 C 1600 C -25 C 0 C 100 C 400 C 600 C 1000 C 1600 C 1767 C 0.51 C 0.43 C 0.37 C 0.28 C 0.22 C 0.21 C 0.20 C 0.24 C 0.51 C 0.43 C 0.38 C 0.29 C 0.23 C 0.22 C 0.22 C 0.26 C -250 C -200 C -100 C 0 C 200 C -200 C -100 C 0 C 200 C 400 C 0.34 C 0.14 C 0.09 C 0.07 C 0.06 C 0.35 C 0.16 C 0.11 C 0.09 C 0.09 C -200 C 0 C 200 C 0 C 200 C 600 C 0.15 C 0.08 C 0.07 C 0.16 C 0.10 C 0.10 C -200 C -100 C 0 C 600 C -100 C 0 C 600 C 800 C 0.10 C 0.07 C 0.06 C 0.07 C 0.11 C 0.09 C 0.08 C 0.09 C 0 C 200 C 600 C 800 C 1600 C 2000 C 200 C 600 C 800 C 1600 C 2000 C 2500 C 0.17 C 0.14 C 0.15 C 0.22 C 0.26 C 0.38 C 0.18C 0.16 C 0.17 C 0.23 C 0.28 C 0.40 C Does not include thermocouple wire error. Type B, E, J ,K, N, R, S and T are based on ITS-90 Type L and U are based on DIN 43710-1985 Type C is based on ASTM standard E 988-96 Type XK and BP are based on GOST R 8.585-2001 RTD and Thermistor Specification, Output RTD Types Pt 385, 100 Pt 3926, 100 Pt 3916, 100 Pt 385, 200 Pt 385, 500 Pt 385, 1000 Ni 120, 120 [2] Cu 427, 10 YSI 400 Range C Minimum -200 C -200 C -200 C -200 C 400 C -200 C -200 C -80 C -100 C 15 C [1] 2-wire output [2] Based on MINCO Application Aid No. 18 Maximum 800 C 630 C 630 C 400 C 630 C 630 C 630 C 260 C 260 C 50 C 5 Fluke Calibration 7526A Precision Process Calibrator Extended Specifications Absolute Uncertainty, tcal 5 C (C) 90 Days 1 Year 0.04 C 0.05 C 0.04 C 0.05 C 0.04 C 0.05 C 0.35 C 0.40 C 0.42 C 0.50 C 0.15 C 0.17 C 0.07 C 0.09 C 0.02 C 0.02 C 0.30 C 0.38 C 0.005 C 0.007 C [1] RTD and Thermistor Specification, Input Absolute Uncertainty, tcal 5 C, (C) Range (C) RTD Type Output/Input Minimum Maximum 90 Days 1 Year -200 C -80 C 100 C 300 C 400 C 630 C -80 C 100 C 300 C 400 C 630 C 800 C 0.012 C 0.018 C 0.022 C 0.025 C 0.031 C 0.037 C 0.013 C 0.020 C 0.024 C 0.026 C 0.033 C 0.038 C -200 C -80 C 0 C 100 C 300 C 400 C -80 C 0 C 100 C 300 C 400 C 630 C 0.012 C 0.014 C 0.016 C 0.022 C 0.022 C 0.024 C 0.013 C 0.015 C 0.017 C 0.022 C 0.026 C 0.032 C -200 C -190 C -80 C 0 C 100 C 300 C 400 C 600 C -190 C -80 C 0 C 100 C 300 C 400 C 600 C 630 C 0.009 C 0.012 C 0.014 C 0.016 C 0.021 C 0.024 C 0.030 C 0.031 C 0.010 C 0.013 C 0.015 C 0.017 C 0.022 C 0.026 C 0.031 C 0.033 C -200 C -80 C 0 C 100 C 260 C 300 C 400 C -80 C 0 C 100 C 260 C 300 C 400 C 630 C 0.047 C 0.050 C 0.053 C 0.054 C 0.062 C 0.064 C 0.079 C 0.053 C 0.056 C 0.060 C 0.060 C 0.069 C 0.071 C 0.088 C -200 C 0 C 100 C 300 C 400 C 0 C 100 C 300 C 400 C 630 C 0.023 C 0.026 C 0.031 C 0.035 C 0.041 C 0.025 C 0.028 C 0.034 C 0.038 C 0.045 C -200 C 0 C 100 C 300 C 400 C 0 C 100 C 300 C 400 C 630 C 0.014 C 0.017 C 0.022 C 0.024 C 0.031 C 0.015 C 0.018 C 0.024 C 0.026 C 0.033 C -80 C 260 C 0.008 C 0.009 C -100 C 260 C 0.097 C 0.110 C YSI 400 15 C 50 C 0.005 C 0.007 C SPRT -200 C 660 C 0.05 C 0.06 C Pt 385, 100 Pt 3926, 100 Pt 3916, 100 Pt 385, 200 Pt 385, 500 Pt 385, 1000 Ni 120, 120 Cu 427, 10 [2] [1] 4-wire mode. Uncertainties shown do not include probe uncertainties. [2] Based on MINCO Application Aid No. 18. 6 Fluke Calibration 5502A Multi-Product Calibrator Extended Specifications [1] Pressure Measurement Specifications The Calibrator can accept the Fluke 700 or 525A-P Series pressure modules. Pressure modules connect directly into the front panel Lemo connector with the Calibrator firmware auto-detecting the type and value of the module you connect. Range Determined by the pressure module Accuracy and Resolution Determined by the pressure module in H2O 4 C (inches of water at 4 degrees Celsius) in H2O 20 C (inches of water at 20 degrees Celsius) in H2O 60 C (inches of water at 60 degrees Fahrenheit) cm H2O 4 C (centimeters of water at 4 degrees Celsius) cm H2O 20 C (centimeters of water at 20 degrees Celsius) mm H2O 4 C (millimeters of water at 4 degrees Celsius) mm H2O 20 C (millimeters of water at 20 degrees Celsius) BAR (bars) mBAR (millibars) kPa (kilopascals) MPa (megapascals) in HG 0 C (inches of mercury at 0 degrees Celsius) mm HG 0 C (millimeters of mercury at 0 degrees Celsius) kg/cm2 (kilograms per square centimeter) Switch Test Specifications, Isolated Input Contact Closure Resistance Excitation Current Units PSI (pounds per square inch) <1 k 27 mA Max 7 Fluke Calibration 7526A Precision Process Calibrator Extended Specifications Ordering Information 7526A Precision Process Calibrator Fluke 700 Series Pressure Modules (continued) Model 7526A Type Dual Description Precision Process Calibrator Includes traceable calibration report, user manual CD, getting started guide, power cord, thermocouple shorting jumper and USB-to-serial adapter cable FLUKE-700PD7 High Recommended Accessories Model Y7526A 7526A-CASE 5520A-525A/LEADS Description Rack Mount Kit Carrying Case Thermocouple and Test Leads Set Fluke 525A Series Pressure Modules Type Model Differential 525A-P02 Gage 525A-P03 525A-P04 525A-P05 525A-P06 525A-P07 525A-P08 525A-P29 Absolute 525A-PA4 525A-PA5 525A-PA6 525A-PA7 525A-PA8 Vacuum 525A-PV4 Range 1 psi (6900 Pa) 5 psi (34 kPa) 15 psi (103 kPa) 30 psi (207 kPa) 100 psi (690 kPa) 500 psi (3400 kPa) 1000 psi (6900 kPa) 3000 psi (20.7 M Pa) 15 psi (103 kPa) 30 psi (207 kPa) 100 psi (690 kPa) 500 psi (3400 kPa) 1000 psi (6900 kPa) -15 psi to 0 psi (-34 kPa) Fluke 700 Series Pressure Modules Type Model Differential FLUKE-700P00 FLUKE-700P01 FLUKE-700P02 FLUKE-700P22 FLUKE-700P03 FLUKE-700P23 FLUKE-700P04 FLUKE-700P24 Gage FLUKE-700P05 FLUKE-700P06 FLUKE-700P27 FLUKE-700P07 FLUKE-700P08 FLUKE-700P09 Absolute FLUKE-700PA3 FLUKE-700PA4 FLUKE-700PA5 FLUKE-700PA6 Vacuum FLUKE-700PV3 FLUKE-700PV4 Dual FLUKE-700PD2 FLUKE-700PD3 FLUKE-700PD4 FLUKE-700PD5 Range 1 in. H2O (0.25 kPa) 10 in. H2O (2.5 kPa) 1 psi (6900 Pa) 1 psi (6900 Pa) 5 psi (34 kPa) 5 psi (34 kPa) 15 psi (103 kPa) 15 psi (103 kPa) 30 psi (207 kPa) 100 psi (690 kPa) 300 psi (2070 kPa) 500 psi (3400 kPa) 1000 psi (6900 kPa) 1500 psi (10 Mpa) 5 psi (34 kPa) 15 psi (103 kPa) 30 psi (207 kPa) 100 psi (690 kPa) -5 psi (-34 kPa) -15 psi (-103 kPa) 1 psi (6900 Pa) 5 psi (34 kPa) 15 psi (103 kPa) -15 psi to 30 psi (-100 to 207 kPa) Model FLUKE-700PD6 FLUKE-700P29 FLUKE-700P30 FLUKE-700P31 Range -15 psi to 100 psi (-100 to 690 kPa) -15 psi to 200 psi (-100 to 1380 kPa) 3000 psi (20.7 MPa) 5000 psi (34 MPa) 10 000 psi (69 MPa) Pumps and Accessories Model FLUKE-700PTP-1 FLUKE-700LTP-1 FLUKE-700PRV-1 Description Pneumatic Test Pump Low-pressure Test Pump Pressure Relief Valve Kit Comparison Test Pumps Model P5510-2M P5513-20M P5514-70M P5515-140M Description Pnuematic Test Pump, vacuum to 300 psi (2 MPa) Pneumatic Test Pump, vacuum to 3000 psi (20 MPa) Hydraulic Test Pump, 0 psi to 10 000 psi (70 MPa) Hydraulic Test Pump, 0 psi to 20 000 psi (140 MPa) Hydraulic Test Pump Model Description FLUKE-700HTH-1 Hydraulic Test Hose FLUKE-700HTP-2 Hydraulic Test Pump, 10 000 PSI (690 bar) 700 PMP Pressure Pump Model Fluke-71X FLUKE-700ILF Description Hose Kit Accessory In-line Filter Pressure Calibration Kit Model FLUKE-700PCK Description Pressure Calibration Kit Thermocouple Plug Kit Model FLUKE-700TC1 FLUKE-700TC2 Description TC Mini-Plug Kit, Types J,K,T,E,R/S,B/Cu,L,U,C,N TC Mini-Plug Kit, Types J,K,T,E,R,S Fluke Calibration. Precision, performance, confidence.TM Fluke Calibration PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (877) 355-3225 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.flukecal.com (c)2012 Fluke Calibration. Specifications subject to change without notice. Printed in U.S.A. 10/2012 4264410A_EN Modification of this document is not permitted without written permission from Fluke Calibration. 8 Fluke Calibration 7526A Precision Process Calibrator Extended Specifications