LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50 W AC/DC Universal Input Switch Mode Power Supplies 1
2 YEAR WARRANTY
NLP40 Series
Single, dual and triple output
4.25 x 2.5 x 1.15 inch package (1U applications)
Smallest industry package
Overvoltage and short circuit protection
40 W with free air convection
EN55022, EN55011 conducted emission level B
EN61000-4-2, -3, -4, -5, -6 immunity compliant
UL, VDE and CSA safety approvals
Available RoHS compliant
The NLP40 series is a 40 W universal input ac-dc power supply on a 4.25 x 2.5 inch card
with a maximum component height of 1.15 inches for use in 1U applications. This product is
the smallest standard 40 W package in the industry making the series ideal for
communication applications with space constraints where a standard 5 x 3 inch card
solution is not suitable. The NLP40 provides 40 W of output power with free air convection
cooling which can be boosted to 50 W with 20 CFM of air. Standard features include
overvoltage and short circuit protection. The series, with full international safety approval and
the CE mark, meets conducted noise EN55022 level B and has immunity compliance to
EN61000-4-2,-3,-4, -5, -6. The NLP40 series is designed for use in low power data
networking, computer and telecom applications such as hubs, routers, POS terminals, LCD
projectors, cable modems and PABX’s. This list is not exclusive as the generic feature set of
the NLP40 series with industry standard output configurations provides a solution for most
low power applications including many industrial applications.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
GENERAL SPECIFICATIONS
Hold-up time 120 Vac 12 ms @ 40 W
230 Vac 20 ms @ 40 W
Efficiency 75% typical
Isolation voltage Input/output 3000 Vac
Input/chassis 1500 Vac
Switching frequency Fixed 65 kHz, ±5 kHz
Approvals and EN60950, IEC950, UL1950
standards (See Note 8) VDE0805, CSA C22.2 No. 950
Weight 200 g (7.06 oz)
MTBF MIL-HDBK-217F 150,000 hours min.
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating ambient, 0 °C to +70 °C
(See Notes 6, 7, 9) (see derating curve)
Non-operating -40 °C to +70 °C
50 °C to 70 °C ambient, Derate to
convection cooled 50% load
0 °C to 50 °C, ambient, 40 W
convection cooled
0 °C to 50 °C ambient, 50 W
20 CFM forced air
Peak (0 °C to +50 °C, 60 s) (See Note 2)
Relative humidity Non-condensing 5% to 95% RH
Altitude Operating 10,000 feet max.
Non-operating 30,000 feet max.
Vibration (See Note 4) 5-500 Hz 2.4 G rms peak
Shock per MIL-STD-810E 516.4 Part IV
OUTPUT SPECIFICATIONS
Total regulation Main output ±2.0%
(Line and load) Auxiliary outputs ±5.0%
Rise time At turn-on 1.0 s, max.
Transient response Main output 5.0% max. dev.,
25% step at 0.1 A/µs 1 ms rec. to 1.0%
Temperature coefficient ±0.02%/°C
Overvoltage protection Main outputs 135%, ±15%
Short circuit protection Cyclic operation Continuous
Minimum output current Single 0 A
Multiple (See Note 5)
INPUT SPECIFICATIONS
Input voltage range Universal input 90-264 Vac
(See Note 9) 120-370 Vdc
Input frequency range 47-440 Hz
Input surge current 120 Vac, cold start 15 A max.
230 Vac, cold start 30 A max.
Safety ground 120 Vac, 60 Hz 0.2 mA
leakage current 230 Vac, 50 Hz 0.4 mA
Input current 120 Vac 1.4 A rms
230 Vac 0.7 A rms
Input fuse UL/IEC127 250 Vac H 3.15 A
EMC CHARACTERISTICS (10)
Conducted emissions EN55022, FCC part 15 level B
Radiated emissions EN55022, FCC part 15 level A
ESD air EN61000-4-2, level 3 Perf. criteria 1
ESD contact EN61000-4-2, level 3 Perf. criteria 1
Surge EN61000-4-5, level 3 Perf. criteria 1
Fast transients EN61000-4-4, level 3 Perf. criteria 1
Radiated immunity EN61000-4-3, level 3 Perf. criteria 1
Conducted immunity EN61000-4-6, level 3 Perf. criteria 1
SPECIFICATIONS
File Name: nlp40.pdf Rev (03): 08 Nov 2005
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
NLP40 Series
Single, dual and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50 W AC/DC Universal Input Switch Mode Power Supplies 2
File Name: nlp40.pdf Rev (03): 08 Nov 2005
OUTPUT OUTPUT CURRENT
RIPPLE (3) TOTAL MODEL NUMBER (11,12)
VOLTAGE MAX (1) PEAK (2) FAN (1) REGULATION
+3.3 V (IA)4 A5 A4.5 A 50 mV ±2.0% NLP40-76T366J (5)
+12 V (IB)2 A3 A3 A120 mV ±5.0%
–12 V (IC)0.2 A 1 A 0.5 A 120 mV ±5.0%
+5 V (IA)4 A5 A4.5 A 50 mV ±2.0% NLP40-7608J (5)
+12 V (IB)2 A3 A3 A120 mV ±5.0%
–12 V (IC)0.2 A 1 A 0.5 A 120 mV ±5.0%
+5 V (IA)4 A5 A4.5 A 50 mV ±2.0% NLP40-7610J (5)
+15 V (IB)1.6 A 2 A 2 A 150 mV ±5.0%
–15 V (IC)0.2 A 1 A 0.5 A 150 mV ±5.0%
+12 V (IA)1.8 A 2.2 A 2.1 A 120 mV ±2.0% NLP40-7627J (5)
-12 V (IB)1.8 A 2.2 A 2.1 A 120 mV ±5.0%
+5 V (IA)4 A5 A4.5 A 50 mV ±2.0% NLP40-7629J (5)
+12 V (IB)2 A3 A3 A120 mV ±5.0%
3.3 V (IA)8 A 10 A 9 A 50 mV ±2.0% NLP40-76S3J
5 V 8 A 10 A 9 A 50 mV ±2.0% NLP40-7605J
12 V 3.3 A 4.5 A 4 A 120 mV ±2.0% NLP40-7612J
15 V 2.6 A 3.6 A 3.3 A 150 mV ±2.0% NLP40-7615J
24 V 1.6 A 2.5 A 2 A 240 mV ±2.0% NLP40-7624J
48 V 0.8 A 1.1 A 1 A 300 mV ±2.0% NLP40-7617J
Notes
1Maximum output power is 40 W for natural convection cooling. With
20 CFM fan cooling, the maximum output power is 50 W.
2Peak output current lasting less than 60 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total reg. limits.
3Figure is peak-to-peak. Output noise measurements are made across a
50 MHz bandwidth using a 12 inch twisted pair, terminated with a 47 µF
capacitor.
4Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G
rms 5 Hz to 500 Hz.
5For multiple output units (except -7627J, 76T366J) to maintain stated
regulation then:
0.25 ≤ IA/ IB5, for IB> 0.3 A
0.50 ≤ IA/ IB5, for IB< 0.3 A
For maximum output current I(C) on triple output models, i.e. for
IC = IMax., I Amin. ≥ 0.5 A and IA≥I
B.
For NLP40-7627J only, to maintain stated regulation then:
0.5 ≤ IA/ IB≤2.
For NLP40-76T366J only, to maintain stated regulation then:
0.25 ≤ IA/ IB≤4.
6For optimum reliability, no part of the heatsink should exceed 120 °C, and
no semiconductor case temperature should exceed 130 °C.
7CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
8This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
9When the input voltage is <90 Vac the operating range is 0 °C to +40 °C.
10 For system EMI compliance, a ground choke may be required before
connecting the ground wire to the chassis. It is recommended that this
ground choke be placed as close as possible to the systems ac inlet to
eliminate noise pick-up in the system.
11 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
12 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
DERATING CURVE
Output Power (Watts)
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
20W
40W
50W
20 CFM FORCED AIR COOLING
25W
NATURAL
CONVECTION
COOLING
Datasheet © Artesyn Technologies
®
2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent
accompany the sale of any such product(s) or information contained herein.
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
NLP40 Series
Single, dual and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50 W AC/DC Universal Input Switch Mode Power Supplies 3
www.artesyn.com
File Name: nlp40.pdf Rev (03): 08 Nov 2005
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File 10401-3336-0093
Licence No. 93662
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
C5
MAXIMUM COMPONENT
HEIGHT 1.15 (29.21)
TOLERANCE: .xxx ± 0.005"
.xx ± 0.02"
ALL DIMENSIONS IN INCHES (mm)
4.25
(107.95)
1
N
J2
4.00
(101.60)
2.25
(57.15)
2.50
(63.50)
F1
L
J1
P1
Mounting
Hole Diameter
0.138 (3.50) Typical
0.125
(3.175)
T1
Input and output connectors
AC (J1) connector type
Molex 26-60-4030 type.
DC (J2) connector type
Molex 26-60-4060 type.
Mating connectors
AC (J1) mating connector type
Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp
terminals.
DC (J2) mating connector type
Molex 09-50-3061 with Triurcon 6838 or equivalent crimp terminals.
Note: The input and output connectors are the same as
those used on NFS40, NFN40, NAL40 and NAN40.
INPUT
PIN CONNECTIONS
J1
Pin 1 AC Line
Pin 2 No Pin
Pin 3 AC Neutral
P1
Pin 1 Safety Ground
OUTPUT PIN CONNECTIONS
J2 SINGLE DUAL TRIPLE
Pin 1 +Vout V (B) V (B)
Pin 2 +Vout V (A) V (A)
Pin 3 +Vout V (A) V (A)
Pin 4 Return Return Return
Pin 5 Return Return Return
Pin 6 Return Return V (C)