LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50 W AC/DC Universal Input Switch Mode Power Supplies 1
2 YEAR WARRANTY
NLP40 Series
Single, dual and triple output
•4.25 x 2.5 x 1.15 inch package (1U applications)
•Smallest industry package
•Overvoltage and short circuit protection
•40 W with free air convection
•EN55022, EN55011 conducted emission level B
•EN61000-4-2, -3, -4, -5, -6 immunity compliant
•UL, VDE and CSA safety approvals
•Available RoHS compliant
The NLP40 series is a 40 W universal input ac-dc power supply on a 4.25 x 2.5 inch card
with a maximum component height of 1.15 inches for use in 1U applications. This product is
the smallest standard 40 W package in the industry making the series ideal for
communication applications with space constraints where a standard 5 x 3 inch card
solution is not suitable. The NLP40 provides 40 W of output power with free air convection
cooling which can be boosted to 50 W with 20 CFM of air. Standard features include
overvoltage and short circuit protection. The series, with full international safety approval and
the CE mark, meets conducted noise EN55022 level B and has immunity compliance to
EN61000-4-2,-3,-4, -5, -6. The NLP40 series is designed for use in low power data
networking, computer and telecom applications such as hubs, routers, POS terminals, LCD
projectors, cable modems and PABX’s. This list is not exclusive as the generic feature set of
the NLP40 series with industry standard output configurations provides a solution for most
low power applications including many industrial applications.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
GENERAL SPECIFICATIONS
Hold-up time 120 Vac 12 ms @ 40 W
230 Vac 20 ms @ 40 W
Efficiency 75% typical
Isolation voltage Input/output 3000 Vac
Input/chassis 1500 Vac
Switching frequency Fixed 65 kHz, ±5 kHz
Approvals and EN60950, IEC950, UL1950
standards (See Note 8) VDE0805, CSA C22.2 No. 950
Weight 200 g (7.06 oz)
MTBF MIL-HDBK-217F 150,000 hours min.
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating ambient, 0 °C to +70 °C
(See Notes 6, 7, 9) (see derating curve)
Non-operating -40 °C to +70 °C
50 °C to 70 °C ambient, Derate to
convection cooled 50% load
0 °C to 50 °C, ambient, 40 W
convection cooled
0 °C to 50 °C ambient, 50 W
20 CFM forced air
Peak (0 °C to +50 °C, 60 s) (See Note 2)
Relative humidity Non-condensing 5% to 95% RH
Altitude Operating 10,000 feet max.
Non-operating 30,000 feet max.
Vibration (See Note 4) 5-500 Hz 2.4 G rms peak
Shock per MIL-STD-810E 516.4 Part IV
OUTPUT SPECIFICATIONS
Total regulation Main output ±2.0%
(Line and load) Auxiliary outputs ±5.0%
Rise time At turn-on 1.0 s, max.
Transient response Main output 5.0% max. dev.,
25% step at 0.1 A/µs 1 ms rec. to 1.0%
Temperature coefficient ±0.02%/°C
Overvoltage protection Main outputs 135%, ±15%
Short circuit protection Cyclic operation Continuous
Minimum output current Single 0 A
Multiple (See Note 5)
INPUT SPECIFICATIONS
Input voltage range Universal input 90-264 Vac
(See Note 9) 120-370 Vdc
Input frequency range 47-440 Hz
Input surge current 120 Vac, cold start 15 A max.
230 Vac, cold start 30 A max.
Safety ground 120 Vac, 60 Hz 0.2 mA
leakage current 230 Vac, 50 Hz 0.4 mA
Input current 120 Vac 1.4 A rms
230 Vac 0.7 A rms
Input fuse UL/IEC127 250 Vac H 3.15 A
EMC CHARACTERISTICS (10)
Conducted emissions EN55022, FCC part 15 level B
Radiated emissions EN55022, FCC part 15 level A
ESD air EN61000-4-2, level 3 Perf. criteria 1
ESD contact EN61000-4-2, level 3 Perf. criteria 1
Surge EN61000-4-5, level 3 Perf. criteria 1
Fast transients EN61000-4-4, level 3 Perf. criteria 1
Radiated immunity EN61000-4-3, level 3 Perf. criteria 1
Conducted immunity EN61000-4-6, level 3 Perf. criteria 1
SPECIFICATIONS