FTA series(80,100,125,150A)
Three phase input type(1-stage filter)
FTA -80 -683 -O
Ordering information
1 Model Name
2 Rated Current
3 Line to ground capacitor code:See table 1.1.
table1.1 Line to ground capacitor code
Code
Leakage Current
(Input 250/500V 60Hz)
(155,335only 250/400V 60Hz)
Line to ground
capacitor
(nominal value)
223 1.0mA/2.0mA max 22,000pF
683 2.5mA/5.0mA max 68,000pF
104 3.5mA/7.0mA max 100,000pF
155 160mA/250mA max 1.5 F
335 320mA/500mA max 3.3 F
*
When the line to ground capacitor code is
different, the attenuation characteristic is different.
4 Option
H:Ultra high attenuation type
"155","335" is not applied.
S:Hexagon socket head cap screw
(Standard type is Hexagon head screw)
U:Improve differential mode attenuation
(Rated voltage 250V)
G:With switch of line to ground capacitor
Only "155","335" is applied.
*
"155" is Leakage current 160mA/250mA max
when the switch state is ON (switched to “ ”).
50μA/80μA max when the switch state is OFF
(switched to
“ ”
).
"335" is Leakage current 320mA/500mA max
when the switch state is ON (switched to “ ”).
50μA/80μA max when the switch state is OFF
(switched to “ ”).
1 2 3 4
Features of FTA series
Circuit Diagram
Book type (Space-saving type)
- 1-stage filter General-purpose High-attenuation (150kHz - 1MHz)
- Selectable leakage current value, Ultra high attenuation type
"155","335" for EU
(Wye type with neutral earth system), With switch of line to ground capacitor "-G"
R
Specifications
No. Items FTA-80-683 FTA-100-683 FTA-125-683 FTA-150-683
1Rated Voltage[V] AC Three phase 500 (voltage range:528 max) 50/60Hz *1 *2
2 Rated Current[A] 80 100 125 150
3 Test Voltage (Terminal-Mounting Plate) 2,500 VAC (Cutoff Current = 100mA), 1minute at room temperature and humidity *3
4
Isolation Resistance (Terminal-Mounting Plate)
500 VDC 100MW min at room temperature and humidity *4
5 Leakage current 250/500V 60Hz 2.5mA/5.0mA max
6 DC resistance 5mW max 4mW max 3mW max 3mW max
7 Safety agency approval temperatures -25 to +85C (Refer to Derating Curve)
8 Operating temperature -40 to +85C (Refer to Derating Curve)
9 Operating humidity 20 to 95%RH (Non condensing)
10 Storage temperature/humidity -40 to +85C/20 to 95%RH (Non condensing)
11 Vibration 10 to 55Hz, 19.6m/s2 (2G), 3min. Period, 1hour each X, Y and Z axis
12 Impact 196.1m/s2 (20G), 11ms Once each X, Y and Z axis
13 Safety agency approvals UL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565 Teil3-1, ENEC
14 Case size (without projection)
100X130X210 mm (WXHXD)
(Option: -G refer to external view)
100X170X260 mm(WXHXD)
(Option: -G refer to external view)
[3.94X5.12X8.27 inches]
[3.94X6.69X10.24 inches]
15 Weight 3.1kg max 4.2kg max
*1 Only capacitor code and option “155”,“335”, Three Phase D-connection:400 (440 max), Wye-connection:500(528 max)
*2 Only option “U”, Three Phase 250(275 max)
*3 Only capacitor code and option “155”,“335”, 2,800VDC (Cutoff Current = 10mA), 1minute at room temperature and humidity.
*4 Only capacitor code and option “155”,“335”, Isolation resistance specification is deleted.
Case Case
: Mounting Plate
CY :
Line to ground capacitor
: Mounting Plate
CY :
Line to ground capacitor
: Mounting Plate
CY :
Line to ground capacitor
CY :
Line to ground capacitor
SW : Switch
(The switch state is OFF)
CY :
Line to ground capacitor
SW
INE
1
2
3
LOAD
4
5
6
CY
CY
LINE
1
2
3
LOAD
4
5
6
CY CY
LINE
1
2
3
LOAD
4
5
6
CY CY
LINE
1
2
3
LOA
4
5
6
INE
1
2
3
LOAD
4
5
6
CY CY
CY
CY
Derating Curve
70 80 90-20 40 50 60
20
0
-40 -30
100
80
60
40
Ambient Temperature [C]
Load Factor [%]
(1) Line to ground capacitor code : 223, 683, 104 (2) Line to ground capacitor code : 155, 335 (3) Line to ground capacitor code : 223, 683, 104
Option : U
(4) Line to ground capacitor code : 155, 335
Option : U
(5) Line to ground capacitor code : 155, 335
Option : G
*Keep free ventilation holes for cooling.
FTA-7