150 04/02
Notes
■If the maximum loads specified for load dump and jump start are fully utilized, subsequent
polarity reversal of the AUTO varistors is inadmissible.
■If the load remains under the maximum ratings, polarity reversal may be admissible.
Contact EPCOS for consultancy on this kind of problem.
■Load dump or jump start can decrease the varistor voltage in load direction by max. 15 %.
■Load dump: min. time of energy input 40 ms, interval 60 s.
Maximum ratings (TA = 85 °C)
Type
SIOV-
Ordering code VRMS
V
VDC
V
imax
8/20 ms
A
Wmax
(2 ms)
J
Pmax
W
WLD
(10x)
J
12-V supply systems
CU3225K14AUTOG2 B72650M1140K072 14 16 100 0,4 0,01 6
CU4032K14AUTOG2 B72660M1140K072 14 16 250 0,9 0,02 12
CU3225K17AUTOG2 B72650M1170K072 17 20 100 0,5 0,01 6
CU4032K17AUTOG2 B72660M1170K072 17 20 250 1,1 0,02 12
24-V supply systems
CU3225K30AUTOG2 B72650M1300K072 30 34 100 0,9 0,01 6
CU4032K30AUTOG2 B72660M1300K072 30 34 250 2,0 0,02 12
Characteristics (TA = 25 °C)
Type
SIOV-
VJump
(5 min)
V
Vv
(1 mA)
V
DVv
(1 mA)
%
Max. clamping
voltage
Ctyp
(1 kHz)
nF
Derating
curve
Page
V/I char-
acteristic
Page
v
V
i
A
12-V supply systems
CU3225K14AUTOG2 25 22 ± 10 43 1,0 1,4 246 274
CU4032K14AUTOG2 25 22 ± 10 43 2,5 2,3 246 275
CU3225K17AUTOG2 30 27 ± 10 53 1,0 1,2 246 274
CU4032K17AUTOG2 30 27 ± 10 53 2,5 1,9 246 275
24-V supply systems
CU3225K30AUTOG2 50 47 ± 10 93 1,0 0,6 246 274
CU4032K30AUTOG2 50 47 ± 10 93 2,5 1,1 246 275
Monolithic; Automotive Series