General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG Plastic body with/without French striker gG 500V Size 0 and 1 from 40 to 250 A * BLADE-STYLE FUSES: WITH BLOWN FUSE INDICATOR or TRIP-INDICATOR * COMPLYING WITH IEC 269.1 AND 2.1 NF EN 60269.1 & 2 NF C 63210 - 63211 AND DIN 43620 * DIMENSIONS: D1 D2 D G M B D1 D G M B F e e H K A C A C H N N L L J J With blown fuse indicator With trip-indicator Size A B C D D1 D2* F* G H J K L M N e Wgt. 0 1 46 52 62 64 59 64 67 74 36 47 39 47 14 14 2,5 3 15 21 14,5 16 14,5 14,5 125 135 10 10 14,5 14,5 6 6 230g 400g * For fuses with trip-indicator Size 0 1 Voltage Current rating rating IN(A) (VAC) 500 500 Accessories: 40 50 63 80 100 125 160 200 80 100 125 160 200 250 Watts loss (W) Designation Ref. Number 4.2 5.5 6.5 8.5 9.5 12 15 19 8.5 9.6 12.5 15 19 23 gG gG gG gG gG gG gG gG gG gG gG gG gG gG With blown fuse indicator 0 / 40 0 / 50 0 / 63 0 / 80 0 / 100 0 / 125 0 / 160 0 / 200 1 / 80 1 / 100 1 / 125 1 / 160 1 / 200 1 / 250 A095013 B095014 C095015 D095016 E095017 F095018 G095019 H095020 K095022 P095026 T095030 V095031 W095032 Z095035 Catalog Number NH0GG50V40-3 NH0GG50V50-3 NH0GG50V63-3 NH0GG50V80-3 NH0GG50V100-3 NH0GG50V125-3 NH0GG50V160-3 NH0GG50V200-3 NH1GG50V80-3 NH1GG50V100-3 NH1GG50V125-3 NH1GG50V160-3 NH1GG50V200-3 NH1GG50V250-3 Neutral link Reference Number Z219304 - Reference Number A219834 Pull-out handle - PMP Reference Number P215592 GPEU46 With trip-indicator Designation Ref. Number Catalog Number gG gG gG gG gG gG gG 0 / 40 P 0 / 50 P 0 / 63 P 0 / 80 P 0 / 100 P 0 / 125 P 0 / 160 P T095214 V095215 W095216 Y095218 A095220 C095222 G095226 NH0GG50V40-4 NH0GG50V50-4 NH0GG50V63-4 NH0GG50V80-4 NH0GG50V100-4 NH0GG50V125-4 NH0GG50V160-4 gG gG gG gG gG gG 1 / 80 P 1 / 100 P 1 / 125 P 1 / 160 P 1 / 200 P 1 / 250 P D095591 E095592 F095593 G095594 H095595 K095597 NH1GG50V80-4 NH1GG50V100-4 NH1GG50V125-4 NH1GG50V160-4 NH1GG50V200-4 NH1GG50V250-4 General Purpose IEC Fuses General Purpose IEC Fuses NH Fuses (Plain Blades) gG Plastic body with/without French striker gG 500V Size 0 and 1 from 40 to 250 A Current Limitation Curves Total Clearing I2t I2t (A2S) Ic (kA) 107 100 106 250 200 105 160 125 100 80 63 50 40 10 104 103 102 1 40 50 63 80 100 125 160 200 250 1 Rating (A) b: total clearing I t @ 500 V 10 100 Ip (kA) 2 Ic = Peak let-through current Ip = Available fault current a: pre-arcing I2t Time VS. Current Characteristics 125 200 40 50 63 80 100 160 250 104 Breaking capacity 100 kA t (s) t (s) = Pre-arcing duration 103 102 10 1 10-1 10 -2 10 100 1 000 GPEU47 10 000 Ip (A) Ip (A) = R.M.S. AVAILABLE FAULT CURRENT