Type: ZB32-16 Article No.: 278452 Ordering information Overload release, min. - max. Ir A 10 - 16 Auxiliary contacts M = Make 1M Auxiliary contacts B = Break 1B For use with DILM17, DILM25, DILM32, DIULM17, DIULM25, DIULM32, SDAINLM30, SDAINLM45, SDAINLM55 Short-circuit protection Type "1" coordination gG/gL A 63 Short-circuit protection Type "2" coordination gG/gL A 35 Contact sequence Note concerning the product Overload release: tripping class 10 A Short-circuit protection: Observe the maximum permissible fuse of the contactor with direct device mounting. Suitable for protection of EEx e-motors. EC prototype test certification on request. 1 Notes concerning the product group Fitted directly to the contactor Separate mounting 1 Contactor 051608 2 Bases 278473 General Standards IEC/EN 60947, VDE 0660, UL, CSA Climatic proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open C -25/50 Enclosed C -25/40 Temperature compensation Continuous Weight Mechanical shock resistance half-sinusoidal shock 10 ms to IEC 60068-2-27 g 10 Protection type IP00 Protection against direct contact when actuated from front (IEC 536) Finger- and back-of-hand proof Main conducting paths Rated impulse withstand voltage Uimp V AC Overvoltage category/pollution degree 6000 III/3 Rated insulation voltage AC Ui V AC 690 Rated operational voltage Ue V AC 690 Between auxiliary contacts and main contacts V AC 440 Between main circuits V AC 440 Safe isolation to VDE 0106 Part 101 and Part 101/A1 Overload release setting range Temperature compensation residual error > 20C A %/K 0,1 - 32 f 0.25 Current heat loss (3 conductors) Lower value of the setting range W 2,5 Maximum setting W 6 2 Terminal capacities Solid mm2 2 x (1 - 6) Flexible with ferrule mm2 2 x (1 - 4) 2 x (1 - 6) Solid or stranded AWG 14 - 8 Terminal screw M4 Tightening torque Nm 1.8 Pozidriv screwdriver Size 2 Standard screwdriver mm 1x6 V 6000 Tools Auxiliary and control circuits Rated impulse withstand voltage Uimp Overvoltage category/pollution degree III/3 Terminal capacities Solid mm2 2 x (0.75 - 4) Flexible with ferrule mm2 2 x (0.75 - 2.5) Solid or stranded AWG 2 x (18 - 12) Terminal screw M3.5 Tightening torque Nm 0.8 - 1.2 Size 2 Tools Pozidriv screwdriver Standard screwdriver mm 1x6 Rated insulation voltage Ui V AC 500 Rated operational voltage Ue V AC 500 V AC 240 Safe isolation to VDE 0106 Part 101 and Part 101/A1 between the auxiliary contacts Conventional thermal current Ith A 6 120 V Ie A 1,5 240 V Ie A 1,5 415 V Ie A 0,5 500 V Ie A 0,5 120 V Ie A 1,5 240 V Ie A 1,5 415 V Ie A 0,9 500 V Ie A 0,8 24 V Ie A 0,9 60 V Ie A 0,75 110 V Ie A 0,4 220 V Ie A 0,2 Rated operational current AC-15 Make contact Break contact DC-13 L/R f 15 ms Short-circuit rating without welding 3 max. fuse A gG/gL 6 Notes Ambient temperature: operating range to IEC/EN 60947, PTB: -5C to +50C Rated operational current: Making and breaking conditions to DC-13, L/R constant as stated See overlay: "Fuses" for short-circuit rating time/current characteristic (please enquire) 6 mm flexible with ferrules to DIN 46228 Dimensions With base ZB32-XEZ Dimensions Dimensions 4 Moeller GmbH, Hein-Moeller-Str. 7-11, D-53115 Bonn E-Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net Copyright 2005 by Moeller GmbH. Subject to modifications. HPL-C2005GB-INT V3.0 5