HC-D 7-ESTC
Order No.: 1772243
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1772243
HEAVYCON male insert, D7 series, 7-pos., crimp connection
Commercial data
EAN 4017918036911
Pack 10 pcs.
Customs tariff 85366990
Weight/Piece 0.01155 KG
Catalog page information Page 438 (PC-2009)
Product notes
WEEE/RoHS-compliant since:
03/01/2006
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
General data
Note For HC-D7 housing, crimp contacts CK1,6-ED (crimp contacts not
included in scope of supply)
Connection method Crimp connection
Ambient temperature (operation) -40 °C ... 125 °C (including heating up of contacts)
Pollution degree 3
Surge voltage category III
HC-D 7-ESTC Order No.: 1772243
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1772243
PHOENIX CONTACT Inc., USA Page 2 / 4
http://www.phoenixcon.com Feb 25, 2010
Constructional and testing regulations DIN VDE 0627/86
DIN VDE 0110/02.79
DIN VDE 0110-1/04.97
IEC 60664-1, DIN IEC 60512
IEC 60352
Number of positions 7
Insertion/withdrawal cycles ≥ 500
Design D7
Connection in acc. with standard IEC / EN
Conductor cross section 0.14 mm² ... 2.5 mm²
Connection cross section AWG 26 ... 14
Stripping length of the individual wire 8 mm
6 mm (2.5 mm2)
Assembly instructions Connectors may be operated only when there is no load/voltage.
Connection The inserts may only be used in plastic housings at voltages >42
V.
Material data
Inflammability class acc. to UL 94 V0
Contact material Copper alloy
Contact surface material Ag (alternatively Au)
Contact carrier material PA
Electrical characteristics
Rated voltage (III/3) 250 V
Rated surge voltage 4 kV
Rated current 10 A
Certificates / Approvals
Certification CSA, GOST, UL
CSA
Nominal voltage UN300 V
Nominal current IN10 A
HC-D 7-ESTC Order No.: 1772243
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1772243
PHOENIX CONTACT Inc., USA Page 3 / 4
http://www.phoenixcon.com Feb 25, 2010
AWG/kcmil 22-16
UL
Nominal voltage UN600 V
Nominal current IN10 A
AWG/kcmil 22-16
Diagrams/Drawings
Diagram
Derating diagram: HC-D...C series
Dimensioned drawing
Male insert (turned contacts)
Schematic diagram
HC-D 7-ESTC Order No.: 1772243
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1772243
PHOENIX CONTACT Inc., USA Page 4 / 4
http://www.phoenixcon.com Feb 25, 2010
Address
PHOENIX CONTACT Inc., USA
586 Fulling Mill Road
Middletown, PA 17057,USA
Phone (800) 888-7388
Fax (717) 944-1625
http://www.phoenixcon.com
© 2010 Phoenix Contact
Technical modifications reserved;