CPF SERIES Back to back dual SCR output for heavy industrial loads Ratings up to 25 amps at 660Vac Zero-crossing (resistive loads) or random-fire (inductive loads) output Pinout compatible with standard 0.6" I/O Modules UL/cUL Recognized, & VDE approved, CE Compliant Part Numbers Output Specifications 48-660Vac 1200 0.1 25 10 60 250 25 10 60 250 260 1.6 260 1.6 500 500 Input Specifications Input voltage Drop out voltage Typical input current (@5Vdc) Nominal Input Resistance (Ohms) Max. turn-on time* Max. turn-off time * Random SSR's turn on in less than 100s General Characteristics 0.5 0.5 3-15Vdc 1Vdc 15 mAdc 300 4-15Vdc 1Vdc 15 mAdc 240 1/2 AC Cycle 1/2 AC Cycle -30 to + 80 -30 to + 125 4000Vrms 10pF (typical) 47 to 63 Hz Thermally Conductive Epoxy bs Operating Temperature (C) Storage Temperature (C) Input to output isolation Input to output capacitance Operating Frequency Encapsulation Weight (typical) Zero-Crossing Output (resistive loads) Rating Output Input Part Number 25 Amp 12-280Vac 3-15VDC CPF240D25 25 Amp 48-660Vac 4-15VDC CPF480D25 Random Fire Output (inductive loads) Rating Output Input Part Number 25 Amp 12-280Vac 3-15VDC CPF240D25R 25 Amp 48-660Vac 4-15VDC CPF480D25R te 12-280Vac 600 0.1 ol e Voltage range (Vrms) Peak voltage (Vpk , t = I min.) Off-state leakage mArms (@ max. line voltage & Ta = 25C) Output current (Arms) Forced Air Convection Minimum current (mArms) Max. 1 cycle surge current (Apk, Ta = 25C) I2T (60Hz, 1/2 cycle) Max. forward voltage drop (Vpk @ Imax, Ta = 25C) Static off-state dv/dt (V/s, Ta = 25C) Power factor (min.) with max load 0.85 oz. (25g) Standards of Compliance O CE Compliant with the LVD 73/23/EEC UL Recognized VDE Approved Products and specifications subject to change without notice www.crouzet-usa.com