www.clare.com
2R01
PLA171
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25ºC
Parameter Ratings Units
Blocking Voltage 800 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1150 mW
Total Power Dissipation 2800 mW
ESD, Human Body Model 8 kV
Isolation Voltage, Input to Output (60 Seconds) 5000 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 3.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Electrical Characteristcs @ 25ºC
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
Continuous 1IF=2mA IL- - ±100 mA
Peak IF=2mA , t=10ms ILPK - - ±350
On-Resistance 2IF=2mA, IL= 100mA RON
-4050
Ω
IF=5mA, IL=1mA - 70 85
Off-State Leakage Current IF=0mA, VL=800VPILEAK --1µA
Switching Speeds
Turn-On IF=5mA, VL=10V ton - 0.42 5 ms
Turn-Off toff - 0.15 5
Output Capacitance IF=0mA, VL=50V, f=1MHz COUT -11-pF
Input Characteristics
Input Control Current 3IL=100mA IF- 0.39 2 mA
Input Dropout Current - IF0.1 - - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR- - 10 µA
Common Characteristics
Input to Output Capacitance - CI/O -3-pF
1 Load derates linearly from 100mA @ 25oC to 55mA @85oC.
2 Measurement taken within 1 second of on-time.
3 For applications requiring high temperature operation (greater than 60oC) a LED drive current of 5mA is recommended.