MRWI60C SERIES DC-DC Power Module 60W FEATURES Fully Encapsulated Plastic Case for Chassis and DIN-Rail Mounting Version Ultra-wide 4:1 Input Voltage Range Fully Regulated Output Voltage Excellent Efficiency up to 92% I/O Isolation 2500 VDC Operating Ambient Temp. Range -40 to +85 Under-voltage, Overload/Voltage and Short Circuit Protection No Min. Load Requirement Remote On/Off Control Conducted EMI EN 55032 Class A & FCC Level A Approved EMC Immunity EN 61000-4-2,3,4,5,6,8 Approved UL/cUL/IEC/EN 60950-1 Safety Approval & CE Marking PRODUCT OVERVIEW The MINMAX MRWI60C series is a new range of regulated DC-DC converter modules with ultra-wide 4:1 input voltage ranges. The product comes in a fully encapsulated module with screw terminal block and is suitable for easy chassis mounting or also for DIN-Rail mounting. Featuring an extended operating temperature range from -40to +85C, EMC compliance to EN 61000-6-1 standard these modules have been designed particularly for industrial applications. Model Selection Guide Input Voltage (Range) Output Voltage Max. @ Max. Load @ No Load VDC VDC 5.1 mA 12000 mA(typ.) 2833 mA(typ.) 100 F 20400 % 90 24 (9 ~ 36) 12 5000 2747 100 3540 91 24 2500 2747 110 890 91 MRWI60-24S48C 48 1250 2747 60 220 91 MRWI60-48S051C 5.1 12000 1401 40 20400 91 MRWI60-48S12C 12 5000 1359 60 3540 92 24 2500 1374 60 890 91 48 1250 1374 50 220 91 Model Number MRWI60-24S051C MRWI60-24S12C MRWI60-24S24C 48 (18 ~ 75) MRWI60-48S24C MRWI60-48S48C Output Current Max. capacitive Load Input Current Efficiency (typ.) @Max. Load Input Specifications Parameter Model 24V Input Models 48V Input Models 24V Input Models 48V Input Models 24V Input Models 48V Input Models Input Surge Voltage (100 ms max.) Start-Up Threshold Voltage Under Voltage Shutdown Start Up Time Power Up Remote On/Off Nominal Vin and Constant Resistive Load Input Filter All Models E-mail:sales@minmax.com.tw 2018/05/07 REV:7 Tel:886-6-2923150 Page 1 of 6 Min. -0.7 -0.7 ------------- Typ. Max. 50 --100 ----9 --18 7.5 --16 ----50 --50 lnternal Pi Type Unit VDC ms ms MRWI60C SERIES DC-DC Power Module 60W Remote On/Off Control Parameter Conditions Min. Converter On Typ. Max. Unit 3.5V ~ 12V or Open Circuit Converter Off 0V ~ 1.2V or Short Circuit Control Input Current (On) Vctrl = 5.0V --- --- 0.5 mA Control Input Current (Off) Vctrl = 0V --- --- -0.5 mA 3 --- mA Typ. 1.0 0.2 0.5 Max. 2.0 1.5 1.0 Unit %Vnom. % % ------- 100 150 200 mV P-P mV P-P mV P-P Control Common Referenced to Negative Input Standby Input Current Supply Off & Nominal Vin --- Output Specifications Parameter Output Voltage Setting Accuracy Line Regulation Load Regulation Minimum Load Conditions/Model Min. ----Vin=Min. to Max. @Full Load --Io=0% to 100% No minimum Load Requirement 5.1V Output Models --0-20MHz bandwith 12V & 24V Output Models --48V Output Models --- Ripple & Noise Transient Recovery Time --- 250 --- sec ------- 3 120 0.02 5 ----- % % of Vo %/ --150 Hiccup Mode 0.25 Hz typ., Automatic Recovery --- % 25% Load Step Change(2) Transient Response Deviation Over Voltage Protection Temperature Coefficient Over Load Protection Short Circuit Protection Zener diode clamp Hiccup General Specifications Parameter Conditions Min. Typ. Max. Unit 60 Seconds 2500 --- --- VDC I/O Isolation Resistance 500 VDC 1000 --- --- M I/O Isolation Capacitance 100KHz, 1V --- --- 3000 pF --- 210 --- KHz I/O Isolation Voltage Switching Frequency MTBF (calculated) MIL-HDBK-217F@25, Ground Benign Safety Approvals 242,029 Hours UL/cUL 60950-1 recognition (UL certificate), IEC/EN 60950-1 (CB-report) Environmental Specifications Parameter Conditions/Model Operating Ambient Temperature Range Natural Convection (5) Nominal Vin, 100% Load (for Power Derating see relative Derating Curves) MRWI60-48S12C MRWI60-24S12C, 24S24C, 24S48C MRWI60-48S051C, 48S24C, 48S48C Min. Max. Unit 76 -40 74 Natural Convection 3.5 71 --- /W 100LFM Convection 1.95 --- /W 200LFM Convection 1.61 --- /W 400LFM Convection 1.33 --- /W Case Temperature --- +95 Storage Temperature Range -50 +125 --- 95 % rel. H Thermal Impedance Humidity (non condensing) Cooling Natural Convection E-mail:sales@minmax.com.tw 2018/05/07 MRWI60-24S051C REV:7 Tel:886-6-2923150 Page 2 of 6 MRWI60C SERIES DC-DC Power Module 60W EMC Specifications Parameter Standards & Level Performance EMI Conducted Class A without adding any external components EMI EMI Radiated Class A external components EN 55024 ESD Radiated immunity Fast transient Surge Conducted immunity PFMF EMS EN 55032, FCC part 15 Class A A A A A A A EN 61000-4-2 Air 8kV , Contact 4kV EN 61000-4-3 10V/m EN 61000-4-4 2kV EN 61000-4-5 2kV EN 61000-4-6 10Vrms EN 61000-4-8 30A/M External Filter meets Radiated EMI EN55032 class A; FCC part 15 level A C2 L1 PIN 3 C1 +Vin PIN 5 +Vout MRWI60C Module PIN 2 -Vin -Vout PIN 7 C3 Model MRWI60-24SXXC MRWI60-48SXXC L1 175H/175H 175H/175H C1 4.7F/50V 3.3F/100V C2 220pF/3KV 220pF/3KV C3 220pF/3KV 220pF/3KV Power Derating Curve 100 100 Natural Convection 20LFM 100LFM 60 200LFM 400LFM 40 100LFM 60 200LFM 400LFM 40 20 20 0 0 ~ 40 0 20 40 60 100 110 80 MRWI60-24S051C Natural Convection 20LFM 100LFM 60 200LFM 400LFM 40 20 0 40 ~ 0 20 40 60 80 Ambient Temperature C MRWI60-48S12C E-mail:sales@minmax.com.tw 2018/05/07 REV:7 Tel:886-6-2923150 Page 3 of 6 ~ 0 20 40 60 80 100 110 MRWI60-24S12C,24S24C,24S48C,48S051C,48S24C,48S48C 100 80 40 Ambient Temperature C Ambient Temperature C Output Power (%) Natural Convection 20LFM 80 Output Power (%) Output Power (%) 80 100 110 MRWI60C SERIES DC-DC Power Module 60W Notes 1 2 3 4 5 6 Specifications typical at Ta=+25, resistive load, nominal input voltage and rated output current unless otherwise noted. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. We recommend to protect the converter by a slow blow fuse in the input supply line. Other input and output voltage may be available, please contact factory. That "natural convection" is about 20LFM but is not equal to still air (0 LFM) Specifications are subject to change without notice. Package Specifications Chassis Mounting Mechanical Dimensions Connections 3.5 Function 1 Remote On/Off 2 -Vin 3 +Vin 3 Top View 2 1 5 67.8 [2.67] 8 6 Indication LED Pin 7 50.0 [1.97] 4x 4 DCON POWER "GOOD" INDICATOR 100.0 [3.94] 4 NC 5 +Vout 6 NC 7 -Vout 8 NC 112.0 [4.41] NC: No Connection Physical Characteristics Case Size : 112.0x67.8x38.0mm (4.41x2.67x1.50 inches) Case Material : Plastic resin (flammability to UL 94V-0 rated) Weight : 300g E-mail:sales@minmax.com.tw 2018/05/07 REV:7 Tel:886-6-2923150 Page 4 of 6 38.0 [1.50] 5.0[0.20] 11.0 [0.43] 16.8 [0.66] 90.0 [3.54] All dimensions in mm Tolerance: 0.5 (inches) (0.02) MRWI60C SERIES DC-DC Power Module 60W Package Specifications with DIN Rail Mounting Bracket (order code AC-DIN-02) Mechanical Dimensions DIN-Rail Mounting Kit 4x 3.5 Top View Indication LED 2 1 5 67.8 [2.67] 3 6 50.0 [1.97] 8 7 4 DCON POWER"GOOD"INDICATOR 100.0 [3.94] 112.0 [4.41] 38.0 [1.50] 11.0 [0.43] 3.0 [0.12] 5.0[0.20] 11.0 [0.43] 16.8 [0.66] 90.0 [3.54] Physical Characteristics Case Size : 112.0x67.8x38.0mm (4.41x2.67x1.50 inches) Case Material : Plastic resin (flammability to UL 94V-0 rated) Weight : 353g Order Code Table Standard MRWI60-24S051C DIN Rail Converter with DIN Rail Mounting AC-DIN-02 MRWI60-24S12C AC-DIN-02 MRWI60-24S051C-DIN02 MRWI60-24S12C-DIN02 MRWI60-24S24C AC-DIN-02 MRWI60-24S24C-DIN02 MRWI60-24S48C AC-DIN-02 MRWI60-24S48C-DIN02 MRWI60-48S051C AC-DIN-02 MRWI60-48S051C-DIN02 MRWI60-48S12C AC-DIN-02 MRWI60-48S12C-DIN02 MRWI60-48S24C AC-DIN-02 MRWI60-48S24C-DIN02 MRWI60-48S48C AC-DIN-02 MRWI60-48S48C-DIN02 E-mail:sales@minmax.com.tw 2018/05/07 REV:7 Tel:886-6-2923150 Page 5 of 6 MRWI60C SERIES DC-DC Power Module 60W Test Setup Peak-to-Peak Output Noise Measurement Test Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC-DC Converter. +Vin +Out Copper Strip Single Output DC / DC Converter -Vin Cout -Out Scope Resistive Load Copper Strip Technical Notes Remote On/Off Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn the power module on and off, the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent. A logic low is 0V to 1.2V. A logic high is 3.5V to 12V. The maximum sink current at the on/off terminal (Pin 1) during a logic low is -100A. Overload Protection To provide hiccup mode protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure overload for an unlimited duration. Overvoltage Protection The output overvoltage clamp consists of control circuitry, which is independent of the primary regulation loop, that monitors the voltage on the output terminals. The control loop of the clamp has a higher voltage set point than the primary loop. This provides a redundant voltage control that reduces the risk of output overvoltage. The OVP level can be found in the output data. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0 at 100 KHz) capacitor of a 10F for the 24V and 48V devices. + DC Power Source +Vin + +Out DC / DC Converter Load Cin - -Vin -Out Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 4.7F capacitors at the output. + +Vin DC Power Source - +Out Single Output DC / DC Converter -Vin Cout Load -Out Maximum Capacitive Load The MRWI60C series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet. Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 95. The derating curves are determined from measurements obtained in a test setup. Position of air velocity probe and thermocouple 15mm / 0.6in 50mm / 2in Air Flow DUT Minmax Technology Co., Ltd. 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: sales@minmax.com.tw 2018/05/07 REV:7 Page 6 of 66