MIL-PRF-39012/26H
w/AMENDMENT 2
`
Center contact retention: 6 pounds (26.69 N) minimum axial force. Applicable to captivated-center-
contact connectors only.
Corrosion (salt spray): MIL-STD-202-101, test condition B.
Voltage standing wave ratio (VSWR): From .5 to 11 GHz, or approximately 80 percent of upper cutoff
frequency of the cable, whichever is lower; 1.30, maximum.
Swept frequency VSWR test setup:
Item 6: VSWR shall be less than 1.02 + .003 F (F in GHz).
Item 16: VSVR shall be less than 1.02 + .003 F (F in GHz).
Second step of VSWR checkout procedure: VSWR shall be less then 1.06 + .007 F (F in GHz).
Group B inspection; VSWR shall be less than 1.05 +.005 F (F in GHz}.
Qualification and group C inspection: VSWR shall not exceed 1.10.
Connector durability: 500 cycles minimum, at 12 cycles per minute, maximum. The connector shall
meet the mating characteristics and force to engage and disengage requirements.
Contact resistance: In milliohms, maximum:
Initial After environment
Center contact 1.5 2.0
Outer contact (silver) .2 Not appl icabl e
Outer contact (nickel) .4 Not appl icabl e
Braid to body .1 Not appl icabl e
Dielectric withs ta ndi ng volt age: MIL-STD-202-301, 1,500 volts rms, minimum at sea level.
Vibration, high frequency: MlL-STD-202-204, test condition B.
Shock: MIL-STD-202-213, test condition I.
Thermal shock: MIL-STD-202-107, test condition B, except test high temperature shall be
+85°C. High temperature shall be at +200°C for connectors using +200’C cables (see tables I and III).
Moisture resistance: MIL-STD-202-106. No measurements at high humidity. Insulation
resistance shall be at least 200 megohms within 5 minutes after removal from humidity.
Corona Leve l:
Voltage: 375 vo lts rms, mi n imu m.
Altitude: 70,000 feet (4.437 kPa).