Specifications
No. Items TAC-04-683 TAC-06-683 TAC-10-683 TAC-20-683 TAC-30-683
1Rated Voltage[V] AC Three Phase 500 (voltage range:528 max) 50/60Hz
2 Rated Current[A] 4 6 10 20 30
3 Test Voltage (Terminal-Mounting Plate) 2,000 VAC (Cutoff Current = 100mA), 1minute at room temperature and humidity
4 Isolation Resistance (Terminal-Mounting Plate) 500 VDC 100MW min at room temperature and humidity
5 Leakage current 250/500V 60Hz 2.5mA/5.0mA max
6 Voltage drop 1.5V max 1.0V max
7 Safety agency approval temperatures -25 to +85C (Refer to Derating Curve)
8 Operating temperature -40 to +85C (Refer to Derating Curve)
9 Operating humidity 20 to 95%RH (Non condensing)
10 Storage temperature/humidity -40 to +85C/20 to 95%RH (Non condensing)
11 Vibration 10 to 55Hz, 19.6m/s2(2G), 3min. Period, 1hour each X, Y and Z axis
12 Impact 196.1m/s2(20G), 11ms Once each X, Y and Z axis
13 Safety agency approvals UL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565 Teil3-1, ENEC
14 Case size (without projection) /Weight
63X64X128 mm [2.48X2.52X5.04 inches] (WXHXD) /620g max (Option : -D refer to external view)
TAC series(4-30A)
Three phase input type(1-stage filter)
TAC -10 -683 -O
Ordering information
1 Model Name
2 Rated Current
3 Line to ground capacitor code:See table 1.1.
table1.1 Line to ground capacitor code
Code Leakage Current
(Input 250/500V 60Hz)
Line to ground
capacitor
(nominal value)
103 0.5mA/1.0mA max 10000pF
223 1.0mA/2.0mA max 22000pF
683 2.5mA/5.0mA max 68000pF
4 Options
D
:DIN rail installation type
1 2 3 4
Features of TAC series
Circuit Diagram Derating Curve
Ambient Temperature [C]
Load Factor [%]
70 80 90-20 40 50 60
20
0
-40 -30
100
80
60
40
High-attenuation type of common mode noise from 150kHz to 1MHz (1-stage filter)
- Three phase rated voltage 500 VAC (voltage range:528V max)
- Selectable leakage current value
- Push down type terminal block
R
*
The dimensions change when the option is set.
Refer to External view.
LOAD
Case
LINE
4
5
6
1
2
3
CY : Line to ground capacitor
CY
CY
: Mounting Plate
DIN rail installation type is optionThe terminal cover is retracted inside the unit
TA-1
TAC,TAH series(4-30A)
External view
4-f5.5Terminal cover
7-M4
Mounting Hole
Protection Earth
64
12
19
[0.75]
[0.47]
[1.97]
[2.48]
[2.52]
[0.08]
20
63
50 ±0.5
83.5
[3.29]
[0.22]
[0.1][1.97]
[0.79]
[5.04]
[4.65]
128
118 ±0.5
(2)
Terminal cover
Input
Terminal
Input
Terminal
Output
Terminal
Output
Terminal
Output
Terminal
Mounting Plate
Name Plate
Tolerance : ±1 [±0.04]
Weight : 620g max
Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 [0.04]
Case : PBT
Dimensions in mm, [ ]=inches
Terminal block screw tighting torque M4:1.6N-m (16.9kgf-cm) max
Closed the terminal cover
50
(2.5)
As this product is adopted push-down type terminal block, this appearance is as follows.
1The terminal cover is retracted inside the unit.
2The screws for connecting the terminals are held in the up right position.
¡Note when installing the EMI/EMC
Filter on a DIN rail.
When the EMI/EMC Filter is grounded through
the DIN rail, the proper noise attenuation may not
be achieved.
Be sure to connect the protection earth (PE) of
the EMI/EMC Filter body to the earth.
DIN rail
7-M4
Mounting Plate
Protection Earth
(11)
108
7
(9)
12
19
20
83.5
(2)
64
63
Terminal cover
Terminal cover
Input
Terminal
Input
Terminal
Output
Terminal
Output
Terminal
Output
Terminal
Tolerance : ±1 [±0.04]
Weight : 620g max
Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 [0.04]
Case : PBT
Dimensions in mm, [ ]=inches
Terminal block screw tighting torque M4:1.6N-m (16.9kgf-cm) max
Name Plate
Closed the terminal cover
50
(2.5)
10
[0.75]
[0.47]
[2.48]
[2.52]
[0.08][0.28]
[0.35]
[3.29]
[0.1][1.97]
[0.79]
[4.25]
[0.39] [0.43]
Standard Type
DIN rail installation Type
Name Plate
DIN rail
TA-3