SPECIFICATION CONTROL DRAWING CHEMINAX 75 OHM, AWG 24, 19 STRANDS OF AWG 36, COAXIAL CABLE 1524A1811 Date: 4-12-00 Revision: C THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200. CONSTRUCTION DETAILS DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE DESIGNATED. CONDUCTOR AWG 24, 19 Strands of AWG 36, Tin-Coated Copper 025 DIELECTRIC Rayfoam L Color - Natural SHIELD AWG 38, Tin-Coated Copper JACKET 152 zerohal fg ee, Outer jacket color will be black (designated by a "0" appended to the part number, e.g., 7524A1811-0) unless otherwise specified. Designate outer jacket color with a dash number in accordance with MIL-STD-681. Raychem CAPACITANCE CHARACTERISTIC IMPEDANCE VELOCITY OF PROPAGATION ELECTRICAL CHARACTERISTICS 75 + 3 ohms, Method B 17.2 pF/t. (nominal) at 1 kHz 79% (nominal) ADDITIONAL REQUIREMENTS ELECTRICAL CONDUCTOR RESISTANCE INSULATION RESISTANCE JACKET FLAWS SPARKTEST IMPULSE TEST VOLTAGE WITHSTAND (DIELECTRIC) ENVIRONMENTAL FLAMMABILITY HEAT SHOCK LOW TEMPERATURE- COLD BEND VOLTAGE WITHSTAND (POST ENVIRONMENTAL) PHYSICAL INSULATION (DIELECTRIC) ELONGATION TENSILE STRENGTH JACKET ELONGATION TENSILE STRENGTH JACKET THICKNESS SHIELD COVERAGE WEIGHT 300 Constitution Drive Menlo Park, California 94625 1-800-2 Raychem FAX: 1-650-361-6297 24.8 ohms/1000 ft. (nominal) 10,000 megohms (minimum) for 1000 ft. 1.0 kV (rms) 6.0 kV (peak) 1000 volts (rms), (minimum) Method B 225C . -30C/4.25 inch mandrel 1000 volts (rms), 1 minute 50% (minimum) 800 Ibf/in? (minimum) 150% (minimum) 1200 Ibf/in? (minimum) .012 inch (nominal) 90% (minimum) 13.3 lbs/1000 ft. (nominal) THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN, REFERENCE DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.