HE
–7– ASCTB183E 201606-T
MOUNTING METHOD
SAFETY STANDARDS
*VDE: Approved for products having a different last digit of Part No. Please contact us.
NOTES
Item UL (Recognized) CSA (Certified) VDE (Certified)* TÜV (Certified) TV rating (UL/CSA)
File No. Contact rating Cycles File No. Contact rating File No. Contact rating File No. Rating Cycles File No. Rating
1 Form A E43028 30A 277V AC 105LR26550 30A 277V AC 40006681 30A 250V AC (cos
φ
=1.0) B 11 04
13461 293
30A 250V AC (cos
φ
=1.0) 105UL: E43028 TV-15
30A 30V DC 10530A 30V DC 30A 250V AC (cos
φ
=0.4) 30A 250V AC (cos
φ
=0.4) 105CSA: LR26550 TV-15
1.5HP 125V AC 1051.5HP 125V AC 5A 110V DC (0ms) 8A 110V DC (0ms) 105——
3HP 250V AC 1053HP 250V AC — — — — —
2 Form A E43028 25A 277V AC 105LR26550 25A 277V AC 40006681 25A 250V AC (cos
φ
=1.0) B 11 04
13461 293
25A 250V AC (cos
φ
=1.0) 105UL: E43028 TV-10
25A 30V DC 10525A 30V DC 25A 250V AC (cos
φ
=0.4) 25A 250V AC (cos
φ
=0.4) 105CSA: LR26550 TV-10
1HP 125V AC 1051HP 125V AC 5A 110V DC (0ms) 8A 110V DC (0ms) 105——
2HP 250V AC 1052HP 250V AC — — — — —
1. Plug-in type 2. Screw terminal type 3. Allowable installation wiring size for
screw terminal types and terminal
sockets
Due to the UP terminals, it is possible to
either directly connect the wires or use
crimped terminal.
M4 screw
Washer Faston No. 250
M4 screw
Washer
1. For cautions for use, please read
“GENERAL APPLICATION
GUIDELINES”.
2. The dust cover should not be
removed since doing so may alter the
characteristics.
3. Avoid use under severe
environmental conditions, such as
high humidity, organic gas or in dust,
oily locations and locations subjected
to extremely frequent shock or
vibrations.
4. When mounting, use spring
washers. Optimum fastening torque
ranges from 49 to 68.6 N·m (5 to 7
kgf·cm).
5. Firmly insert the receptacles so that
there is no slack or looseness. To
remove a receptacle, 19.6 to 39.2 N
(2 to 4 kg) of pulling strength is
required. Do not remove more than
one receptacle at one time. Always
remove one receptacle at a time and
pull it straight outwards.
6. When using the AC type, the operate
time due to the in-rush phase is 20 ms
or more. Therefore, it is necessary for
you to verify the characteristics for
your actual circuit.
7. When using the push-on blocks for
the screw terminal type, use crimped
terminals and tighten the screw-down
terminals to the torque below.
M4.5 screw: 147 to 166.6 N⋅cm (15 to 17
kgf·cm)
M4 screw: 117.6 to 137 N·cm (12 to 14
kgf·cm)
M3.5 screw: 78.4 to 98 N·cm (8 to 10
kgf·cm)