Ordering information AC-DC Power Supplies Enclosed Type PLA15F PL 1 A 2 15 3 F 4 Example recommended EMI/EMC filter NAC-04-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. -O 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *7 C : with Coating J : Connector interface T : Vertical terminal block -NO : with DIN rail See 5.1 in Instruction Manual. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 100V ACIN 115V ACIN 230V ACIN 100V INRUSH CURRENT[A] ACIN 115V ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] ACIN 85-115V WATTAGE[W] ACIN 115V-264V *4 LINE REGULATION[mV] LOAD REGULATION[mV] *4 0 to +50C -10 to 0C *1 RIPPLE[mVp-p] Io=0 to 35% 0 to +50C OUTPUT RIPPLE NOISE[mVp-p] *1 -10 to 0C Io=0 to 35% 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND OPERATING INDICATION OTHERS REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG ISOLATION OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE *5 STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT AGENCY APPROVALS SAFETY AND CONDUCTED NOISE NOISE REGULATIONS HARMONIC ATTENUATOR *8 INPUT PLA-2 EFFICIENCY[%] PLA15F-5 PLA15F-12 PLA15F-15 PLA15F-24 AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) *3 0.4typ (Io=90%) 0.4typ (Io=100%) 0.25typ (Io=100%) 50 / 60 (47 - 63) 72.5typ (Io=90%) 75.5typ (Io=90%) 77.0typ (Io=90%) 78.0typ (Io=90%) 73.5typ (Io=100%) 77.0typ (Io=100%) 78.5typ (Io=100%) 79.0typ (Io=100%) 75.5typ (Io=100%) 78.5typ (Io=100%) 79.5typ (Io=100%) 80.0typ (Io=100%) 16typ (Io=90%) Ta=25C at cold start 16typ (Io=100%) Ta=25C at cold start 32typ (Io=100%) Ta=25C at cold start 0.30max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 5 12 15 24 3 1.3 1 0.7 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 15.0 15.6 15.0 16.8 20max 48max 60max 96max 40max 100max 120max 150max 80max 120max 120max 120max 140max 160max 160max 160max 160max 240max 240max 280max 120max 150max 150max 150max 160max 180max 180max 180max 240max 300max 300max 320max 50max 120max 150max 240max 60max 150max 180max 290max 20max 48max 60max 96max 200typ (ACIN 115V, Io=100%) *Start-up time is 700 ms typ for less than 1 minute of applying input again from turning off the input voltage. 20typ (ACIN 115V, Io=100%) 4.50 to 5.50 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 Works over 105% of rating and recovers automatically 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 LED (Green) Not provided Not provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature) -20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes 196.1m/s2 (20G), 11ms, once each X, Y and Z axes UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 class A PLA15F SPECIFICATIONS OTHERS CASE SIZE/WEIGHT COOLING METHOD WARRANTY WARRANTY *6 38X80X73mm [1.50X3.15X2.87 inches] (Excluding terminal block and screw) (WXHXD) / 250g max Convection 5 years (subject to the operating conditions) *1This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to KeisokuGiken RM103. See 1.6 of Instruction Manual for more details. When the load factor is 0 - 35%, the switching power loss is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications. *2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3As for DC input, consult us for advice. *4Consult us about dynamic load and input response. Measure the output voltage by using the average mode of the tester to deal with the burst operation at 35% load or less. *5Output power derating is required. See 3.2 in Instruction Manual. *6See 3.3 in Instruction Manual for more details. *7Consult us about safety agency approvals for the models with optional functions. *8Consult us about other classes. *Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges. Otherwise the internal components may be damaged. * Parallel operation is not possible with this mode. *Sound noise may be heard from the power supply when used for pulse load. Features - Compact design (Depth: 73mm 2.87inches) - Low power consumption (1.0W typ AC240Vin, no load at standard model) - UL508 approved (Except option -J), and complies with SEMI F47 - Various connection interface options (vertical terminal [-T], AMP connector [-J]) Block diagram FUSE AC250V 2.5A INRUSH CURRENT LIMIT NOISE FILTER AC IN 85 - 264V RECTIFIER AND FILTER FG TRANSFORMER CONTROL RECTIFIER AND FILTER INVERTER OVER CURRENT SENSING DC OUT Photocoupler CONTROL Photocoupler OVER VOLTAGE PROTECTION External view 2-M3 Name plate TB1 8.2 FG( ) [0.32] M3.5 AC(L) AC(N) 80 46.5 [1.83] Output terminal(+) Output voltage adjustable potentiometer [3.15] 9.5 [0.37] Output terminal(-) 6.2 [0.24] Terminal cover 15.3 1.5 (LED) [0.6] [0.67] 17 1.5 [0.5] [0.26] 12.7 1.5 6.5 1.5 V.ADJ LED Point A Mounting hole (Bottom side) 18 [0.71] 12.5max 35.5 0.5 [1.4] 73 [2.87] [0.49] 14 1.5 [0.55] 11.6 1.5 (Potentiometer) 38 20 46 0.5 [1.81] [0.79] 20 [0.79] 18 [0.71] [1.5] [0.46] Tolerance : 1 [0.04] Weight : 250g max PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] Chassis material : Electric galvanizing steel board Case material : Electric galvanizing steel board Dimensions in mm, [ ]=inches Mounting torque : 0.6N-m max Screw tightening torque : 1.0N-m max 2-M3 Mounting hole PLA-3 Ordering information AC-DC Power Supplies Enclosed Type PLA30F PL 1 A 2 30 3 F 4 Example recommended EMI/EMC filter NAC-04-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. -O 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *7 C : with Coating J : Connector interface T : Vertical terminal block -NO : with DIN rail See 5.1 in Instruction Manual. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 100V ACIN 115V ACIN 230V ACIN 100V INRUSH CURRENT[A] ACIN 115V ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] ACIN 85-115V WATTAGE[W] ACIN 115V-264V *4 LINE REGULATION[mV] LOAD REGULATION[mV] *4 0 to +50C *1 RIPPLE[mVp-p] -10 to 0C 0 to +50C OUTPUT RIPPLE NOISE[mVp-p] *1 -10 to 0C 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND OPERATING INDICATION OTHERS REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG ISOLATION OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE *5 STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT AGENCY APPROVALS SAFETY AND CONDUCTED NOISE NOISE REGULATIONS HARMONIC ATTENUATOR *8 INPUT PLA-4 EFFICIENCY[%] PLA30F-5 PLA30F-12 PLA30F-15 PLA30F-24 AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) *3 0.7typ (Io=90%) 0.7typ (Io=100%) 0.4typ (Io=100%) 50 / 60 (47 - 63) 73.0typ (Io=90%) 80.0typ (Io=90%) 81.0typ (Io=90%) 82.5typ (Io=90%) 74.0typ (Io=100%) 80.5typ (Io=100%) 81.5typ (Io=100%) 83.0typ (Io=100%) 77.0typ (Io=100%) 81.0typ (Io=100%) 82.0typ (Io=100%) 83.5typ (Io=100%) 16typ (Io=90%) Ta=25C at cold start 16typ (Io=100%) Ta=25C at cold start 32typ (Io=100%) Ta=25C at cold start 0.65max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 5 12 15 24 6 2.5 2 1.3 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 30.0 30.0 30.0 31.2 20max 48max 60max 96max 40max 100max 120max 150max 80max 120max 120max 120max 140max 160max 160max 160max 120max 150max 150max 150max 160max 180max 180max 180max 50max 120max 150max 240max 60max 150max 180max 290max 20max 48max 60max 96max 150typ (ACIN 115V, Io=100%) 20typ (ACIN 115V, Io=100%) 4.50 to 5.50 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 Works over 105% of rating and recovers automatically 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 LED (Green) Not provided Not provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature) -20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes 196.1m/s2 (20G), 11ms, once each X, Y and Z axes UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 class A PLA30F SPECIFICATIONS OTHERS CASE SIZE/WEIGHT COOLING METHOD WARRANTY WARRANTY *6 38X80X88mm [1.50X3.15X3.46 inches] (Excluding terminal block and screw) (WXHXD) / 330g max Convection 5 years (subject to the operating conditions) *1This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to KeisokuGiken RM103. See 1.6 of Instruction Manual for more details. *2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3As for DC input, consult us for advice. *4Consult us about dynamic load and input response. *5Output power derating is required. See 3.2 in Instruction Manual. *6See 3.3 in Instruction Manual for more details. *7Consult us about safety agency approvals for the models with optional functions. *8Consult us about other classes. *Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges. Otherwise the internal components may be damaged. * Parallel operation is not possible with this mode. *Sound noise may be heard from the power supply when used for pulse load. Features - Compact design (Depth: 88mm 3.46inches) - UL508 approved (Except option -J), and complies with SEMI F47 - Various connection interface options (vertical terminal [-T], AMP connector [-J]) Block diagram FUSE AC250V 3.15A INRUSH CURRENT LIMIT NOISE FILTER AC IN 85 - 264V RECTIFIER AND FILTER FG TRANSFORMER CONTROL RECTIFIER AND FILTER INVERTER OVER CURRENT SENSING DC OUT Photocoupler CONTROL Photocoupler OVER VOLTAGE PROTECTION External view 2-M3 Mounting hole (Bottom side) Name plate TB1 8.2 FG( ) [0.32] M3.5 AC(L) AC(N) 43.5 [1.71] 20 17 1.5 [0.67] [0.5] [0.26] 12.7 1.5 6.5 1.5 V.ADJ 6.2 [0.24] Terminal cover [0.79] Output terminal(+) Output voltage adjustable potentiometer 80 [3.15] 9.5 [0.37] Output terminal(-) LED Point A 15.3 1.5 (LED) [0.6] 62.5 19 0.5 [2.46] [0.75] 12.5max 88 [3.46] [0.49] 14 1.5 [0.55] 11.6 1.5 (Potentiometer) 38 20 [0.79] Tolerance : 1 [0.04] Weight : 330g max PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] Chassis material : Electric galvanizing steel board Case material : Electric galvanizing steel board Dimensions in mm, [ ]=inches Mounting torque : 0.6N-m max Screw tightening torque : 1.0N-m max 38 [1.5] [1.5] [0.46] 41 0.5 [1.61] 2-M3 Mounting hole PLA-5 Ordering information AC-DC Power Supplies Enclosed Type PLA50F PL 1 A 2 50 3 F 4 Example recommended EMI/EMC filter NAC-04-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. -O 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *7 C : with Coating J : Connector interface T : Vertical terminal block -NO : with DIN rail See 5.1 in Instruction Manual. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 100V ACIN 115V ACIN 230V INPUT ACIN 100V POWER FACTOR ACIN 115V ACIN 230V ACIN 100V INRUSH CURRENT[A] ACIN 115V ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] CURRENT[A] ACIN 85-115V WATTAGE[W] ACIN 115V-264V *4 LINE REGULATION[mV] LOAD REGULATION[mV] *4 0 to +45C *1 RIPPLE[mVp-p] -10 to 0C OUTPUT 0 to +45C RIPPLE NOISE[mVp-p] *1 -10 to 0C 0 to +45C TEMPERATURE REGULATION[mV] -10 to +45C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND OPERATING INDICATION OTHERS REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG ISOLATION OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE *5 STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT AGENCY APPROVALS SAFETY AND NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR *8 EFFICIENCY[%] PLA-6 PLA50F-5 PLA50F-12 PLA50F-15 PLA50F-24 AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) *3 0.6typ (Io=90%) 0.7typ (Io=90%) 0.6typ (Io=100%) 0.7typ (Io=100%) 0.3typ (Io=100%) 0.4typ (Io=100%) 50 / 60 (47 - 63) 74.5typ (Io=90%) 80.0typ (Io=90%) 80.0typ (Io=90%) 81.5typ (Io=90%) 75.0typ (Io=100%) 80.5typ (Io=100%) 80.5typ (Io=100%) 82.0typ (Io=100%) 76.5typ (Io=100%) 82.0typ (Io=100%) 82.0typ (Io=100%) 84.0typ (Io=100%) 0.97typ (Io=90%) 0.98typ (Io=90%) 0.97typ (Io=100%) 0.98typ (Io=100%) 0.85typ (Io=100%) 0.87typ (Io=100%) 16typ (Io=90%) Ta=25C at cold start 16typ (Io=100%) Ta=25C at cold start 32typ (Io=100%) Ta=25C at cold start 0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 5 12 15 24 8 4.3 3.5 2.2 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 40.0 51.6 52.5 52.8 20max 48max 60max 96max 40max 100max 120max 150max 80max 120max 120max 120max 140max 160max 160max 160max 120max 150max 150max 150max 160max 180max 180max 180max 50max 120max 150max 240max 60max 150max 180max 290max 20max 48max 60max 96max 350typ (ACIN 115V, Io=100%) 20typ (ACIN 115V, Io=100%) 4.50 to 5.50 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 Works over 105% of rating and recovers automatically 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 LED (Green) Not provided Not provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature) -20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes 196.1m/s2 (20G), 11ms, once each X, Y and Z axes UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 class A PLA50F SPECIFICATIONS CASE SIZE/WEIGHT COOLING METHOD WARRANTY WARRANTY 38X80X99mm [1.50X3.15X3.90 inches] (Excluding terminal block and screw) (WXHXD) / 400g max Convection 5 years (subject to the operating conditions) OTHERS *6 *1This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to KeisokuGiken RM103. See 1.6 of Instruction Manual for more details. *2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3As for DC input, consult us for advice. *4Consult us about dynamic load and input response. *5Output power derating is required. See 3.2 in Instruction Manual. *6See 3.3 in Instruction Manual for more details. *7Consult us about safety agency approvals for the models with optional functions. *8Consult us about other classes. *Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges. Otherwise the internal components may be damaged. * Parallel operation is not possible with this mode. *Sound noise may be heard from the power supply when used for pulse load. Features - Compact design (Depth: 99mm 3.90inches) - UL508 approved (Except option -J), and complies with SEMI F47 - Various connection interface options (vertical terminal [-T], AMP connector [-J]) Block diagram FUSE AC250V 2.5A NOISE FILTER AC IN 85 - 264V RECTIFIER INRUSH CURRENT LIMIT FG BOOSTER INDUCTOR TRANSFORMER CURRENT SENSING CONTROL RECTIFIER AND FILTER RECTIFIER AND FILTER INVERTER Photocoupler OVER CURRENT SENSING INVERTER DC OUT CONTROL Photocoupler OVER VOLTAGE PROTECTION CONTROL External view 2-M3 Mounting hole (Bottom side) Name plate TB1 M3.5 8.2 [0.32] AC(L) AC(N) FG( ) 80 [1.75] 44.5 Output terminal(+) Output voltage adjustable potentiometer [3.15] 9.5 [0.37] Output terminal(-) 6.2 [0.24] Terminal cover 15.3 1.5 (LED) [0.6] [0.67] 17 1.5 [0.5] 12.7 1.5 1.5 6.5 [0.26] V.ADJ LED Point A 19 [0.75] 12.5max 76 0.5 [2.99] 99 [3.9] [0.49] 14 1.5 [0.55] 11.6 1.5 (Potentiometer) 38 [0.79] 20 20 [0.79] Tolerance : 1 [0.04] Weight : 400g max PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] Chassis material : Electric galvanizing steel board Case material : Electric galvanizing steel board Dimensions in mm, [ ]=inches Mounting torque : 0.6N-m max Screw tightening torque : 1.0N-m max [1.5] [0.46] 38 [1.5] 52 0.5 [2.05] 2-M3 Mounting hole PLA-7 Ordering information AC-DC Power Supplies Enclosed Type PLA100F PL 1 A 100 2 3 F 4 Example recommended EMI/EMC filter NAC-04-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. -O 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *7 C : with Coating R : Remote on/off (Required external power source) J : Connector interface T : Vertical terminal block -NO : with DIN rail See 5.1 in Instruction Manual. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. SPECIFICATIONS * Please consider "PBA100F-5-N" about 5V output with case cover. MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 100V ACIN 115V ACIN 230V INPUT ACIN 100V POWER FACTOR ACIN 115V ACIN 230V ACIN 100V INRUSH CURRENT[A] ACIN 115V ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 85-115V CURRENT[A] ACIN 115V-264V ACIN 85-115V WATTAGE[W] ACIN 115V-264V *4 LINE REGULATION[mV] LOAD REGULATION Io=30 to 100% *4 Io=0 to 30% [mV] 0 to +40C RIPPLE[mVp-p] *1 -10 to 0C Io: load factor Io=0 to 30% OUTPUT 0 to +40C RIPPLE NOISE[mVp-p] *1 -10 to 0C Io: load factor Io=0 to 30% 0 to +40C TEMPERATURE REGULATION[mV] -10 to +40C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND OPERATING INDICATION OTHERS REMOTE SENSING REMOTE ON/OFF *9 INPUT-OUTPUT RC INPUT-FG ISOLATION *9 OUTPUT RC-FG *9 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE *5 STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT AGENCY APPROVALS SAFETY AND NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR *8 EFFICIENCY[%] PLA-8 PLA100F-12 PLA100F-15 PLA100F-24 PLA100F-36 PLA100F-48 AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) *3 1.2typ (Io=90%) 1.1typ (Io=100%) 0.6typ (Io=100%) 50 / 60 (47 - 63) 82typ (Io=90%) 83typ (Io=90%) 85typ (Io=90%) 86typ (Io=90%) 86typ (Io=90%) 82typ (Io=100%) 83typ (Io=100%) 85typ (Io=100%) 86typ (Io=100%) 86typ (Io=100%) 85typ (Io=100%) 86typ (Io=100%) 88typ (Io=100%) 89typ (Io=100%) 89typ (Io=100%) 0.98typ (Io=90%) 0.98typ (Io=100%) 0.95typ (Io=100%) * Power factor correction is stopped at AC250V or more. 16typ (Io=90%) Ta=25C at cold start 16typ (Io=100%) Ta=25C at cold start 32typ (Io=100%) Ta=25C at cold start 0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 12 15 24 36 48 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 8.4 6.7 4.3 2.8 2.1 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 100.8 100.5 103.2 100.8 100.8 48max 60max 96max 144max 192max 100max 120max 150max 150max 300max Burst operation (Please contact us about detail) 120max 120max 120max 150max 150max 160max 160max 160max 200max 400max 500max 500max 500max 500max 500max 150max 150max 150max 200max 200max 180max 180max 180max 240max 500max 600max 600max 600max 600max 600max 120max 150max 240max 360max 480max 180max 180max 290max 440max 600max 48max 60max 96max 144max 192max 500typ (ACIN 115V, Io=100%) Ta=25C 20typ (ACIN 115V, Io=100%) 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 Works over 105% of rating and recovers automatically 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 54.00 to 67.20 LED (Green) Not provided Optional (Required external power source. Option -R) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes 196.1m/s2 (20G), 11ms, once each X, Y and Z axes UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 class A PLA100F SPECIFICATIONS CASE SIZE/WEIGHT COOLING METHOD WARRANTY WARRANTY 41X97X109mm [1.61X3.82X4.29 inches] (Excluding terminal block and screw) (WXHXD) / 500g max Convection 5 years (subject to the operating conditions) OTHERS *6 hour warm-up at 25C. As for DC input, consult us for advice. *3 *4Consult us about dynamic load and input response. Measure the output voltage by using the average mode of the tester to deal with the burst operation at 30% load or less. *5Output power derating is required. See 3.2 in Instruction Manual. *6See 3.3 in Instruction Manual for more details. Consult us about safety agency approvals for the models with optional functions. *7 *8Consult us about other classes. *1This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken RM103. See 1.6 of Instruction Manual for more details. When the load factor is 0 - 30%, the switching power loss is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications. *2Drift is the change in DC output for an eight hour period after a half- *9 The RC terminal is added to option -R models. The RC terminal is isolated from input, output, and FG. Do not use the power supply in overcurrent conditions or in unspecified * input voltage ranges. Otherwise the internal components may be damaged. * Parallel operation is not possible with this mode. *Sound noise may be heard from the power supply when used for pulse load. Features - Compact design (Depth: 109mm 4.29inches) - High efficiency (88%typ PLA100F-24, AC230Vin, 100% load) - Low power consumption (1.5W typ AC240Vin, no load at standard model) - UL508 approved (Except option -J), and complies with SEMI F47 (see instruction manual 1.1) - Various connection interface options (vertical terminal [-T], AMP connector [-J]) Block diagram FUSE 250V 3.15A NOISE FILTER AC IN 85 - 264V INRUSH CURRENT LIMIT RECTIFIER FG RC(-R) CURRENT SENSING BOOSTER INDUCTOR RECTIFIER AND FILTER CURRENT SENSING EXTERNAL SOURCE CONTROL OVER VOLTAGE PROTECTION INVERTER RECTIFIER AND FILTER INVERTER CONTROL DC OUT External view The external size of -R option, -J option, -N1 option and -T option models is different from the standard model. See "5. Options and Others" in Instruction Manual for more details. 2-M3 Name plate Mounting hole (Bottom side) M3.5 AC(L) Terminal cover AC(N) Point A 97 [3.82] 51 [0.49] 760.5 [2.99] 109 [4.29] 101 [3.98] 33.5 [1.32] 66.50.5 [2.62] 41 [1.61] [0.71] [0.47] [0.83] 12 180.5 3.5 [0.14] 4 [0.16] [0.83] 28.5 Tolerance : 1 [0.04] Weight : 500g max PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] Chassis material : Aluminum Cover material : Electric galvanizing steel board Dimensions in mm, [ ]=inches Mounting torque : 0.49N-m max Screw tightening torque : M3.5 1.0N-m max Connect the input FG to safety earth ground. 12.5max [1.12] [0.6] 11.61.5 (potentiometer) [0.46] 19.5 [0.77] 21 15.31.5 (LED) [2.01] 2 1 CN4 Connector for Remote ON/OFF (option) 3.5 21 [0.14] 9.5 [0.37] 6.2 [0.24] 221.5 [0.57] 14.61.5 141.5 [0.55] 32.81.5 [1.29] 8.2 Output terminal(+) Output voltage adjustable potentiometer LED [0.86] Output terminal(-) [0.32] FG( ) 3-M3 Mounting hole PLA-9 Ordering information AC-DC Power Supplies Enclosed Type PLA150F PL 1 A 150 2 3 F 4 Example recommended EMI/EMC filter NAC-04-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. -O 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *7 C : with Coating R : Remote on/off (Required external power source) J : Connector interface T : Vertical terminal block -NO : with DIN rail See 5.1 in Instruction Manual. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. SPECIFICATIONS * Please consider "PBA150F-5-N" about 5V output with case cover. MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 100V ACIN 115V ACIN 230V INPUT ACIN 100V POWER FACTOR ACIN 115V ACIN 230V ACIN 100V INRUSH CURRENT[A] ACIN 115V ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 85-115V CURRENT[A] ACIN 115V-264V ACIN 85-115V WATTAGE[W] ACIN 115V-264V *4 LINE REGULATION[mV] LOAD REGULATION Io=30 to 100% *4 Io=0 to 30% [mV] 0 to +40C RIPPLE[mVp-p] *1 -10 to 0C Io: load factor Io=0 to 30% OUTPUT 0 to +40C RIPPLE NOISE[mVp-p] *1 -10 to 0C Io: load factor Io=0 to 30% 0 to +40C TEMPERATURE REGULATION[mV] -10 to +40C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND OPERATING INDICATION OTHERS REMOTE SENSING REMOTE ON/OFF *9 INPUT-OUTPUT RC INPUT-FG ISOLATION *9 OUTPUT RC-FG *9 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE *5 STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT AGENCY APPROVALS SAFETY AND NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR *8 EFFICIENCY[%] PLA-10 PLA150F-12 PLA150F-15 PLA150F-24 PLA150F-36 PLA150F-48 AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) *3 1.7typ (Io=90%) 1.6typ (Io=100%) 0.8typ (Io=100%) 50 / 60 (47 - 63) 84typ (Io=90%) 84typ (Io=90%) 87typ (Io=90%) 87typ (Io=90%) 87typ (Io=90%) 84typ (Io=100%) 84typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 90typ (Io=100%) 90typ (Io=100%) 90typ (Io=100%) 0.98typ (Io=90%) 0.98typ (Io=100%) 0.95typ (Io=100%) * Power factor correction is stopped at AC250V or more. 16typ (Io=90%) Ta=25C at cold start 16typ (Io=100%) Ta=25C at cold start 32typ (Io=100%) Ta=25C at cold start 0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 12 15 24 36 48 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 12.5 10 6.4 4.2 3.2 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 150.0 150.0 153.6 151.2 153.6 48max 60max 96max 144max 192max 100max 120max 150max 150max 300max Burst operation (Please contact us about detail) 120max 120max 120max 150max 150max 160max 160max 160max 200max 400max 500max 500max 500max 500max 500max 150max 150max 150max 200max 200max 180max 180max 180max 240max 500max 600max 600max 600max 600max 600max 120max 150max 240max 360max 480max 180max 180max 290max 440max 600max 48max 60max 96max 144max 192max 500typ (ACIN 115V, Io=100%) Ta=25C 20typ (ACIN 115V, Io=100%) 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 Works over 105% of rating and recovers automatically 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 54.00 to 67.20 LED (Green) Not provided Optional (Required external power source. Option -R) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes 196.1m/s2 (20G), 11ms, once each X, Y and Z axes UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 class A PLA150F SPECIFICATIONS CASE SIZE/WEIGHT COOLING METHOD WARRANTY WARRANTY 41X97X129mm [1.61X3.82X5.08 inches] (Excluding terminal block and screw) (WXHXD) / 600g max Convection 5 years (subject to the operating conditions) OTHERS *6 *1This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken RM103. See 1.6 of Instruction Manual for more details. When the load factor is 0 - 30%, the switching power loss is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications. *2Drift is the change in DC output for an eight hour period after a half- hour warm-up at 25C. *3As for DC input, consult us for advice. *4Consult us about dynamic load and input response. Measure the output voltage by using the average mode of the tester to deal with the burst operation at 30% load or less. *5Output power derating is required. See 3.2 in Instruction Manual. *6See 3.3 in Instruction Manual for more details. Consult us about safety agency approvals for the models with optional functions. *7 *8Consult us about other classes. *9The RC terminal is added to option -R models. The RC terminal is isolated from input, output, and FG. * Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges. Otherwise the internal components may be damaged. * Parallel operation is not possible with this mode. *Sound noise may be heard from the power supply when used for pulse load. Features - Compact design (Depth: 129mm 5.08inches) - High efficiency (90%typ PLA150F-24, AC230Vin, 100% load) - Low power consumption (1.5W typ AC240Vin, no load at standard model) - UL508 approved (Except option -J), and complies with SEMI F47 (see instruction manual 1.1) - Various connection interface options (vertical terminal [-T], AMP connector [-J]) Block diagram FUSE 250V 4A NOISE FILTER AC IN 85 - 264V INRUSH CURRENT LIMIT RECTIFIER FG RC(-R) CURRENT SENSING BOOSTER INDUCTOR CURRENT SENSING EXTERNAL SOURCE CONTROL RECTIFIER AND FILTER OVER VOLTAGE PROTECTION INVERTER RECTIFIER AND FILTER INVERTER CONTROL DC OUT External view The external size of -R option, -J option, -N1 option and -T option models is different from the standard model. See "5. Options and Others" in Instruction Manual for more details. Name plate 2-M3 Mounting hole (Bottom side) Point B M3.5 AC(L) Terminal cover AC(N) Point A 97 [3.82] 49.5 [1.95] 3.5 9.5 [0.37] 21 [0.14] [0.55] [0.57] 141.5 14.61.5 [0.86] 221.5 LED 32.81.5 [1.29] Output voltage adjustable potentiometer B [0.24] Output terminal(+) 6.2 8.2 Output terminal(-) [0.32] FG( ) 2 1 CN4 Connector for Remote ON/OFF (option) 15.31.5(LED) 19 960.5 [3.78] [0.75] 12.5max 129 [0.49] [5.08] [0.6] 4 [0.83] 48 [1.89] 700.5 [2.76] 41 3.5 [0.14] 21 [0.83] 28.5 [1.12] Tolerance : 1 [0.04] Weight : 600g max PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] Chassis material : Aluminum Cover material : Electric galvanizing steel board Dimensions in mm, [ ]=inches Mounting torque : 0.49N-m max Screw tightening torque : M3.5 1.0N-m max Connect the input FG to safety earth ground. 121 [4.76] [0.16] [1.61] [0.46] 12 180.5 [0.47] [0.71] 11.61.5(potentiometer) 3-M3 Mounting hole PLA-11 Ordering information AC-DC Power Supplies Enclosed Type PLA300F PL 1 A 2 300 3 F 4 Example recommended EMI/EMC filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. -O 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *7 C : with Coating G : Low leakage current V : External potentiometer for output voltage adjustment U : Low input voltage stop (Complies with SEMI F-47) R : Remote on/off (Required external power source) F4: Low speed fan T2: Horizontal terminal block (non-screw-hold type) See 5.1 in Instruction Manual. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 100V ACIN 115V ACIN 230V INPUT ACIN 100V POWER FACTOR ACIN 115V ACIN 230V ACIN 100V INRUSH CURRENT[A] ACIN 115V ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 85-115V CURRENT[A] ACIN 115V-264V ACIN 85-115V WATTAGE[W] ACIN 115V-264V *4 LINE REGULATION[mV] LOAD REGULATION[mV] *4 0 to +50C RIPPLE[mVp-p] *1 -10 to 0C OUTPUT 0 to +50C RIPPLE NOISE[mVp-p] *1 -10 to 0C 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND OPERATING INDICATION OTHERS REMOTE SENSING REMOTE ON/OFF *10 INPUT-OUTPUT RC INPUT-FG ISOLATION *10 OUTPUT RC-FG *10 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE *5 STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT AGENCY APPROVALS SAFETY AND NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR *9 EFFICIENCY[%] PLA-12 PLA300F-5 PLA300F-12 PLA300F-15 PLA300F-24 PLA300F-36 PLA300F-48 AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) *3 3.1typ (Io=90%) 3.4typ (Io=90%) 3.0typ (Io=100%) 3.3typ (Io=100%) 1.5typ (Io=100%) 1.7typ (Io=100%) 50 / 60 (47 - 63) 73typ (Io=90%) 78typ (Io=90%) 79typ (Io=90%) 81typ (Io=90%) 81typ (Io=90%) 82typ (Io=90%) 74typ (Io=100%) 78typ (Io=100%) 80typ (Io=100%) 82typ (Io=100%) 82typ (Io=100%) 83typ (Io=100%) 77typ (Io=100%) 81typ (Io=100%) 83typ (Io=100%) 86typ (Io=100%) 86typ (Io=100%) 86typ (Io=100%) 0.98typ (Io=90%) 0.98typ (Io=100%) 0.95typ (Io=100%) 20typ (Io=90%) Ta=25C at cold start 20typ (Io=100%) Ta=25C at cold start 40typ (Io=100%) Ta=25C at cold start 0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 5 12 15 24 36 48 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 50 25 20 12.5 8.4 6.3 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 250 300 300 300 302.4 302.4 20max 48max 60max 96max 144max 192max 40max 100max 120max 150max 150max 300max 80max 120max 120max 120max 150max 150max 140max 160max 160max 160max 160max 400max 120max 150max 150max 150max 200max 200max 160max 180max 180max 180max 240max 500max 50max 120max 150max 240max 360max 480max 75max 180max 180max 290max 440max 600max 20max 48max 60max 96max 144max 192max 300typ (ACIN 115V, Io=100%) 20typ (ACIN 115V, Io=100%) 4.50 to 5.50 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80 5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 Works over 105% of rating and recovers automatically 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20 LED (Green) Not provided Optional (Required external power source. Option -R) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes 196.1m/s2 (20G), 11ms, once each X, Y and Z axes UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 class A PLA300F SPECIFICATIONS CASE SIZE/WEIGHT COOLING METHOD WARRANTY WARRANTY OTHERS 102X41X190mm [4.02X1.61X7.48 inches] (Excluding terminal block and screw) (WXHXD) / 1.0kg max Forced cooling (internal fan) 5 years (subject to the operating conditions) *8 *6 *1This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken RM103. See 1.6 of Instruction Manual for more details. *2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3Output power derating is required. As for DC input, consult us for advice. *4Consult us about dynamic load and input response. *5See 3.2 in Instruction Manual. *6See 3.3 in Instruction Manual for more details. Consult us about safety agency approvals for the models with optional functions. *7 *8The fan speed slows down at no load. *9Consult us about other classes. *10The RC terminal is added to option -R models. The RC terminal is isolated from input, output, and FG. * Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges. Otherwise the internal components may be damaged. * Parallel operation is not possible with this mode. *Sound noise may be heard from the power supply when used for pulse load. Features - Cost-effective - Longer life (see Instruction Manual) - Low profile (meets 1U height = 41 mm or 1.61 inches) - Wide operating temperature range (-20 - Screw hold type terminal block to +70 see instruction manual) - Slow fan speed at no load - Many optional functions - Complies with SEMI F-47 (-U option, see Instruction Manual for details) Block diagram FUSE 250V 10A NOISE FILTER AC IN 85 - 264V INRUSH CURRENT LIMIT RECTIFIER FG CURRENT SENSING BOOSTER INDUCTOR RECTIFIER AND FILTER CURRENT SENSING CONTROL CONTROL OVER VOLTAGE PROTECTION INVERTER CONTROL INVERTER RECTIFIER AND FILTER THERMAL PROTECTION CONTROL DC OUT FAN External view The external size of -V option, -R option, and -T2 option models is different from the standard model. See "5. Options and Others" in Instruction Manual for more details. 13.1 1.5 (potentiometer) [0.52] 102 [2.36] 5max [7.48] [0.2max] [0.98] 25 0.5 190 19.5 150 0.5 [0.77] [5.91] AIR FLOW [1.61] [5.91] [4.02] 60 0.5 150 0.5 [0.49] [0.65] Tolerance : 1 [0.04] Weight : 1.0kg max PCB Material/thickness : CEM-3 / 1.6mm [0.06inches] Chassis material : Aluminum Case material : Electric galvanizing steel board Dimensions in mm, [ ]=inches Mounting torque : 1.2N m max Screw tightening torque : 1.6N m max Connect the input FG to safety earth ground. [0.77] 19.5 12.5 10.5 5.7 [0.22] 1.5 [0.41] 8.6 [0.34] AC AC FG (N) (L) M4 16.6 4-M4 Mounting Hole (Bottom side) 41 [0.78] Name plate [0.79max] 10 [0.49] -V FG( ) AC(N) AC(L) 20max [0.39] Output terminal (-) V.ADJ +V +V -V Output terminal (+) 19.8 1.5 [0.23] Output voltage adjustable potentiometer 12.5 1.5 [0.66] LED 5.75 1.5 16.8 1.5 (LED) 4-M4 Mounting Hole PLA-13 Ordering information AC-DC Power Supplies Enclosed Type PLA600F PL 1 A 2 600 3 F 4 Example recommended EMI/EMC filter NAC-16-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. -O 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *7 C : with Coating G : Low leakage current V : External potentiometer for output voltage adjustment U : Low input voltage stop (Complies with SEMI F-47) W: Parallel operation, LV alarm Remote sensing R : Remote on/off (Required external power source) F4 : Low speed fan T2: Horizontal terminal block (non-screw-hold type) See 5.1 in Instruction Manual. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. *Please consider "PJA600F-5" about 5V output. SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 100V ACIN 115V ACIN 230V INPUT ACIN 100V POWER FACTOR ACIN 115V ACIN 230V ACIN 100V INRUSH CURRENT[A] ACIN 115V ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 85-115V CURRENT[A] ACIN 115V-264V ACIN 85-115V WATTAGE[W] ACIN 115V-264V *8 LINE REGULATION[mV] LOAD REGULATION[mV] *8 0 to +50C RIPPLE[mVp-p] *1 -20 to 0C OUTPUT 0 to +50C RIPPLE NOISE[mVp-p] *1 -20 to 0C 0 to +50C TEMPERATURE REGULATION[mV] -20 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND OPERATING INDICATION OTHERS REMOTE SENSING REMOTE ON/OFF *3 INPUT-OUTPUT RC INPUT-FG ISOLATION *3 OUTPUT RC-FG *3 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE *5 STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT AGENCY APPROVALS SAFETY AND NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR *10 EFFICIENCY[%] PLA-14 PLA600F-12 PLA600F-15 PLA600F-24 PLA600F-36 PLA600F-48 AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) *4 6.7typ (Io=90%) 6.5typ (Io=100%) 3.2typ (Io=100%) 50 / 60 (47 - 63) 81typ (Io=90%) 81typ (Io=90%) 84typ (Io=90%) 85typ (Io=90%) 85typ (Io=90%) 81typ (Io=100%) 81typ (Io=100%) 84typ (Io=100%) 85typ (Io=100%) 85typ (Io=100%) 84typ (Io=100%) 84typ (Io=100%) 88typ (Io=100%) 88typ (Io=100%) 88typ (Io=100%) 0.98typ (Io=90%) 0.98typ (Io=100%) 0.95typ (Io=100%) 20/40typ (Io=90%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start) 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start) 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start) 1.5max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN) 12 15 24 36 48 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 50 40 25 16.7 12.5 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 600 600 600 601.2 600 48max 60max 96max 144max 192max 100max 120max 150max 150max 300max 120max 120max 120max 150max 150max 160max 160max 160max 160max 400max 150max 150max 150max 200max 200max 180max 180max 180max 240max 500max 120max 150max 240max 360max 480max 180max 180max 290max 440max 600max 48max 60max 96max 144max 192max 300typ (ACIN 115V, Io=100%) 20typ (ACIN 115V, Io=100%) 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 Works over 105% of rating and recovers automatically 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20 LED (Green) Optional (Option -W) Optional (Required external power source. Option -R) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes 196.1m/s2 (20G), 11ms, once each X, Y and Z axes UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 class A PLA600F SPECIFICATIONS CASE SIZE/WEIGHT COOLING METHOD WARRANTY WARRANTY OTHERS *9 *6 120X61X215mm [4.72X2.40X8.46 inches] (Excluding terminal block and screw) (WXHXD) / 2.0kg max Forced cooling (internal fan) 5 years (subject to the operating conditions) *1This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken RM103. See 1.6 of Instruction Manual for more details. *2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3The RC terminal is added to option -R models. The RC terminal is isolated from input, output, and FG. As for DC input, consult us for advice. *4 *5Output power derating is required. See 3.2 in Instruction Manual. *6See 3.3 in Instruction Manual for more details. Consult us about safety agency approvals for the models with optional functions. *7 *8Consult us about dynamic load and input response. *9The fan speed slows down at no load. *10 Consult us about other classes. Do not use the power supply in overcurrent conditions or in unspecified * input voltage ranges. Otherwise the internal components may be damaged. * Parallel operation is allowed for PLA600F models with the -W option only. * Sound noise may be heard from the power supply when used for pulse load. Features - Cost-effective - Screw hold type terminal block - Longer life (see Instruction Manual) - Slow fan speed at no load - Low profile (meets 2U height = 61 mm or 2.40 inches) - Wide operating temperature range (-20 instruction manual) to +70 - Many optional functions - Complies with SEMI F-47 (-U option, see Instruction Manual for details) see Block diagram FUSE 250V 16A NOISE FILTER AC IN 85 - 264V BOOSTER INDUCTOR INRUSH CURRENT LIMIT RECTIFIER RECTIFIER AND FILTER CURRENT SENSING INVERTER FG CONTROL CURRENT SENSING RC (-R) External source THERMAL PROTECTION CONTROL PARALLEL-OPERATION CIRCUIT Current balance (-W) OVER VOLTAGE PROTECTION DETECTING OUTPUT VOLTAGE LV alarm (-W) CONTROL RECTIFIER AND FILTER INVERTER DC OUT CONTROL FAN External view The external size of -V option, -W option, -R option, and -T2 option is different from the standard model. See "5. Options and Others" in Instruction Manual for more details. 26.61.5 [1.05] 16.61.5 [0.65] 15.81.5 (LED) [0.62] Output terminal cover 24.81.5 [0.98] 4-M4 Mounting Hole (Bottom sides) Name plate FG [5.91] 215 [0.12max] [1.5] Tolerance : 1 [0.04] Weight : 2.0kg max PCB Material/thickness : FR-4 / 1.6mm [0.06inches] Chassis material : Electric galvanizing steel board Case material : Electric galvanizing steel board Dimensions in mm, [ ]=inches Mounting torque : 1.5N-m max Screw tightening torque : M3.5 0.8N-m max M4 1.6N-m max Connect the input FG to safety earth ground. 3max 380.5 [8.46] 35 [1.38] 1500.5 [5.91] AIR FLOW [2.4] 1500.5 10 35 [1.38] 61 M3.5 (AC,FG) [0.61] [0.61] 15.5 15.51.5 [0.39] 8.1 [0.32] 10 AC AC (N) (L) [0.39] 120 [4.72] [3.94] [0.47] 12 10 -V [0.39] -V 1000.5 [3.12] 79.251.5 7.4 [0.29] [0.73] [0.41] [0.83max] +V Output terminal (-) FG( ) AC(N) AC(L) 21max +V Output terminal (+) M4 (+V,-V) V.ADJ LED Output voltage adjustable potentiometer 10.51.5 [0.48] 18.51.5 12.11.5 (potentiometer) 4-M4 Mounting Hole PLA-15