Electrical data
Primary nominal Primary current, Primary conductor Type RoHS since
current rms measuring range 1) diameter x turns date code
IPN (A) IPM (A) (mm)
3± 9 0.6d x 20T HX 03-P/SP2 46128
5± 15 0.8d x 12T HX 05-P/SP2 46019
10 ± 30 1.1d x 6T HX 10-P/SP2 45352
15 ± 45 1.4d x 4T HX 15-P/SP2 46133
20 ± 60 1.6d x 3T HX 20-P/SP2 planned
25 ± 75 1.6d x 2T HX 25-P/SP2 46233
50 ± 150 1.2 x 6.3 x 1T HX 50-P/SP2 46152
VOUT Output voltage (Analog) @ ± IPN, RL = 2 kΩ, TA = 25°C VOE ± 0.625 V
ROUT Output internal resistance < 50 Ω
R LLoad resistance ≥ 2 kΩ
VCSupply voltage (± 5 %) + 12 .. 15 V
I CCurrent consumption < 15 mA
VdRms voltage for AC isolation test, 50 Hz, 1 min > 3 kV
VePartial discharge extinction voltage rms @ 10 pC ≥ 1 kV
VWImpulse withstand voltage, 1.2/50 µs≥ 6 kV
Accuracy-Dynamic performance data
XAccuracy @ IPN, TA = 25°C (excluding offset) < ± 1 % of IPN
εLLinearity error (0 .. ± IPN)< ± 1 % of IPN
VOE Electrical offset voltage @ TA = 25°C + 2.5V ± 50 mV
VOH Hysteresis offset voltage @ IP = 0;
after an excursion of 1 x IPN < ± 10 mV
TCVOE Temperature coefficient of VOE < ± 1.5 mV/K
TCVOUT Temperature coefficient of VOUT (% of reading) ± 0.1 %/K
t rResponse time to 90% of IPN step ≤ 3 µs
BW Frequency bandwidth (- 3 dB) 2) 50 kHz
General data
TAAmbient operating temperature - 25 .. + 85 °C
TSAmbient storage temperature - 25 .. + 85 °C
mMass 8 g
dCp Creepage distance ≥ 5.5 mm
Isolation material group I
Standards EN50178: 1997
Current Transducer HX 03..50-P/SP2
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 3 .. 50 A
Notes : 1) With R L=2kΩ
2) Small signal only to avoid excessive heating of the magnetic core
Features
•Galvanic isolation between primary
and secondary circuit
•Hall effect measuring principle
•Isolation voltage 3000V
•Low power consumption
•Extended measuring range(3x IPN)
•Isolated plastic case recognized
according to UL94-V0.
Special feature
•Single supply from +12V to +15V
Advantages
•Low insertion losses
•Easy to mount with automatic
handling system
•Small size and space saving
•Only one design for wide current
ratings range
•High immunity to external
interference.
Applications
•Switched Mode Power Supplies
(SMPS)
•AC variable speed drives
•Uninterruptible Power Supplies
(UPS)
•Electrical appliances
•Battery supplied applications
•DC motor drives
Application domain
•Industrial
070313/6 www.lem.com
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/2