Electrical data
Primary nominal Primary current, Primary conductor Type RoHS since
current rms measuring range 1) diameter x turns date code
IPN (A) IPM (A) (mm)
3± 9 0.6d x 20T HX 03-P/SP2 46128
5± 15 0.8d x 12T HX 05-P/SP2 46019
10 ± 30 1.1d x 6T HX 10-P/SP2 45352
15 ± 45 1.4d x 4T HX 15-P/SP2 46133
20 ± 60 1.6d x 3T HX 20-P/SP2 planned
25 ± 75 1.6d x 2T HX 25-P/SP2 46233
50 ± 150 1.2 x 6.3 x 1T HX 50-P/SP2 46152
VOUT Output voltage (Analog) @ ± IPN, RL = 2 k, TA = 25°C VOE ± 0.625 V
ROUT Output internal resistance < 50
R LLoad resistance 2 k
VCSupply voltage (± 5 %) + 12 .. 15 V
I CCurrent consumption < 15 mA
VdRms voltage for AC isolation test, 50 Hz, 1 min > 3 kV
VePartial discharge extinction voltage rms @ 10 pC 1 kV
VWImpulse withstand voltage, 1.2/50 µs 6 kV
Accuracy-Dynamic performance data
XAccuracy @ IPN, TA = 25°C (excluding offset) < ± 1 % of IPN
εLLinearity error (0 .. ± IPN)< ± 1 % of IPN
VOE Electrical offset voltage @ TA = 25°C + 2.5V ± 50 mV
VOH Hysteresis offset voltage @ IP = 0;
after an excursion of 1 x IPN < ± 10 mV
TCVOE Temperature coefficient of VOE < ± 1.5 mV/K
TCVOUT Temperature coefficient of VOUT (% of reading) ± 0.1 %/K
t rResponse time to 90% of IPN step 3 µs
BW Frequency bandwidth (- 3 dB) 2) 50 kHz
General data
TAAmbient operating temperature - 25 .. + 85 °C
TSAmbient storage temperature - 25 .. + 85 °C
mMass 8 g
dCp Creepage distance 5.5 mm
Isolation material group I
Standards EN50178: 1997
Current Transducer HX 03..50-P/SP2
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 3 .. 50 A
Notes : 1) With R L=2k
2) Small signal only to avoid excessive heating of the magnetic core
Features
Galvanic isolation between primary
and secondary circuit
Hall effect measuring principle
Isolation voltage 3000V
Low power consumption
Extended measuring range(3x IPN)
Isolated plastic case recognized
according to UL94-V0.
Special feature
Single supply from +12V to +15V
Advantages
Low insertion losses
Easy to mount with automatic
handling system
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
Applications
Switched Mode Power Supplies
(SMPS)
AC variable speed drives
Uninterruptible Power Supplies
(UPS)
Electrical appliances
Battery supplied applications
DC motor drives
Application domain
Industrial
070313/6 www.lem.com
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/2
3
19 Max.
0.5 20Max.
3-P=2.54
1
2
3
4
+V
OUT 6 5
8.8 5.4
1.3 5
-V or 0
0
3.5
3
HX 50-P
38.8 5.4
1.2
3
19 Max.
0.5 20Max.
3-P=2.54
1
2
3
4
+V
OUT
5
-V or 0
0
3.5
3
10.85
3.5
d
10.85
6
6
15.4 Max.
15.4 Max.
Top view
Lot No.
HX 05-P
41123
HX 03...25-P
Dimensions HX 03..50-P/SP2 (in mm. 1 mm = 0.0394 inch)
Terminal Pin Identification
1 ..... 0V
2 ..... 0V
3 ..... +12V to +15V
4 ..... Output
5 ..... Primary input Current (+)
6 ..... Primary input Current (-)
Primary conductor diameter
Secondary pins dimension
0.5 x 0.25
HX 02..25-P HX 50-P
HX 50-P/SP2
HX 03..25-P/SP2
HX 03-P/
SP2
05-P/
SP2
10-P/
SP2
15-P/
SP2
d 0.6 0.8 1.1 1.4
HX 20-P/
SP2
25-P/
SP2
50-P/
SP2
d 1.6 1.6 1.2 x 6.3
Bottom view
Bottom view
070313/6 www.lem.com
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 2/2
Safety
This transducer must be used in electric/electronic equipment
with respect to applicable standards and safety requirements
in accordance with the following manufacturer's operating
instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Mechanical characteristics
General tolerance ± 0.5 mm
HX 05-
P/
SP2