(R) Cole Hersee Co. HEAVY DUTY CATALOG O R BS EF O ER LE T EN E C FO E R O N LY D-400 Manufacturers of DC electrical and electronic switches and connectors for the vehicle industry (R) Heavy duty electrical products. On the road, off the road, on the job. Construction & Off-Road *Skidsteer Loaders *Graders *Cement Mixer Trucks *Excavators *Compactors O R BS EF O ER LE T EN E C FO E R O N LY *Backhoes *Pavers *Rollers *Bulldozers Emergency Vehicles *Ambulances *Police *Fire *Emergency Apparatus *Resuce Equipment Factory & Airport Vehicles *Runway Trucks Carriers *Foam Trucks *Baggage Handlers *People *Forklifts *Scissorlifts *Gensets Buses and RVs *Motor Homes *RVs *Motorcoaches *School *Buses *Tourist Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com Buses Trolleys Vehicles Vehicles Street Trucks *Postal *Street *Utility Vehicles Company Trucks *Bucket Trucks *Delivery Trucks *Garbage Sweepers Trucks *Dumpster Trucks *Snowplows Groundskeeping *Golf Carts *Service Carts *Mowers *Ditch Diggers *Edgers *ATVs O R BS EF O ER LE T EN E C FO E R O N LY Cranes of all kinds *Crawler Cranes *Cherrypickers *Aerial Lifts and Platforms *Rigging Vehicles Cranes *Tower Cranes *Truck Cranes *Boom www.colehersee.com Agriculture, Forestry & Mining *Harvesters *Balers *Combines *Tractors *Swathers *Grapple & Windrowers *Feed Conveyors *Screen Skidders Plants Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com table of contents Section Page A1 A2 A3 A4 A5 A6 1 4 6 7 9 10 B1 B2 B3 B4 B5 12 14 15 17 18 C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 19 22 22 24 25 26 27 28 28 29 30 31 32 33 D1 D2 D3 D4 D5 34 36 37 38 39 E1 E2 E3 E4 E5 40 43 44 45 46 A Vehicle connectors Tractor-Trailer Connectors 1-6 Pole Connectors Socket and Plug Interiors Automotive Trailer Connectors Farm Equipment Connectors Accessories B Ignition and key switches (R) O R BS EF O ER LE T EN E C FO E R O N LY 956 Series Ignition and Starter Switches Universal Ignition and Starter Switches Specialized Ignition Switches 95060 Series Sealed Key Switches Accessories Cole Hersee Cole Hersee Co has been manufacturing reliable electrical products since 1924. This Heavy Duty Catalog describes our complete line, but we can adapt many of these products to order by changing terminals, knobs, by adding seals or by PVC-coating (to name but a few variants). Contact us to discuss the possibilities. Our engineers are on hand to design from the ground up the best switching solution to your application. Cole Hersee is trusted world wide for reliable switches. Availability of products: Rapid Ship: Items that are likely to be in stock at Cole Hersee 95% of the time, on average. * Minimum order quantities may apply to these items. Consult Cole Hersee. Copyright (c) Cole Hersee Company Edition 00 Cole Hersee Company has compiled the information in this catalog from company records and other authoritative sources, and believes the information to be accurate as of the date of printing. We offer this catalog as a guide and a convenience to customers. Since the user's specific application is beyond the control of Cole Hersee Company, we make no warranty or representation regarding the results that may be obtained by the user, or the suitability of the part for the user's application. C Rocker & Toggle Switches Weather-Resistant Rocker Switches Standard Rocker, Plastic Bezel Standard Rocker, Metal Bezel Dual Rocker Switches Rocker Accessories 54100 Series Toggle Switches Paddle Handle Toggle Switches Freightliner Toggle Switches Lighted Tip Toggle Switches Heavy Duty Toggle Switches Medium Duty Off-On Switches 551800 Series Toggle Switches Specialized Toggle Switches Accessories D Battery-related products Master Disconnect Switches Battery Selector/Master Disconnect Switches Accessories Battery Isolators Low Voltage Disconnect Switches E Solenoids & Relays Steel & Phenolic Body Solenoids PVC Coated Solenoids Plastic Body Solenoids Electronic Solenoids Relays Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com table of contents Section F Page F1 F2 F3 F4 F5 48 50 50 50 51 G1 G2 G3 54 55 56 G wiper & dimmer switches L1 L2 L3 L4 L5 L6 88 89 90 90 91 91 Additional Information 92 Neutral Safety Switches Back-Up Switches Overdrive Kickdown Switches Foot-Operated Turn Switches Stoplamp Switches Voltage Reducers M Additional Information O R BS EF O ER LE T EN E C FO E R O N LY Electronic Wiper Switches Electronic Two-Speed Wiper Switches Electronic Dimmer Switches Page L Special purpose Switches Momentary switches Heavy Duty Push-Button Switches Two Circuit Push-Button Switches Caps for Push-Button Switches Specialized Momentary Switches Door Momentary Switches Section H Push-pull, rotary & headlamp Switches One Circuit Push-Pull Switches Two Circuit Push-Pull Switches Specialized Switches Push-Pull Headlamp Switches Rotary Headlamp Switches Universal Rotary Switches Rotary Temperature & Rheostat Switches Foot-Operated Switches I J H1 H2 H3 H4 H5 H6 H7 H8 56 57 57 58 60 60 61 62 Specialized Modules 64 Specialized modules circuit protection, blocks & Fasteners Circuit Breakers Breaker Accessories Blocks & Busbars Terminal Blocks Connectors & Terminals Clamps, Cleats, Clips & Ties J1 J2 J3 J4 J5 J6 65 67 68 69 71 75 K1 K2 K3 K4 K5 K6 K7 K8 77 77 78 79 80 81 84 85 K monitoring devices Temperature Switches Oil Pressure Switches Air Pressure & Vacuum Switches Fuel Pump Switch Warning Devices Pilot Lights Hooded Panel Lamps Lamp Sockets & Accessories Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com index Part Number Section Page 3- & 4-Digit Numbers F3 F3 D3 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 A4 A4 A4 A4 A4 A4 A4 A4 A4 A3 A3 A3 A6 A4 A1 A2 A2 A2 A2 A4 A2 A2 A1 A2 A2 A5 A5 A3 50 50 37 13 13 13 13 13 13 12 12 12 12 13 13 12 13 12 12 12 12 12 12 12 12 12 12 13 8 8 8 8 8 9 9 8 9 6 6 6 11 9 3 4 5 4 4 8 5 5 3 4 4 9 9 6 Section Page 1292 . . . . . . . . . . . . . 1295 . . . . . . . . . . . . . 1296 . . . . . . . . . . . . . 1449 . . . . . . . . . . . . 1624 . . . . . . . . . . . . 2106 . . . . . . . . . . . . 2316 . . . . . . . . . . . . 2430 . . . . . . . . . . . . . 2484 . . . . . . . . . . . . 2484-A . . . . . . . . . . . 2484-02 . . . . . . . . . 2484-06 . . . . . . . . . 2484-09 . . . . . . . . . 2484-16 . . . . . . . . . 2505 . . . . . . . . . . . . 2506 . . . . . . . . . . . . 2560 . . . . . . . . . . . . 2561 . . . . . . . . . . . . 2564 . . . . . . . . . . . . 2609 . . . . . . . . . . . . 2610 . . . . . . . . . . . . 2611 . . . . . . . . . . . . 2612 . . . . . . . . . . . . 2670 . . . . . . . . . . . . 3029 . . . . . . . . . . . . . 3031 series . . . . . . . . 3032 . . . . . . . . . . . . . 3051 . . . . . . . . . . . . . 3088 series . . . . . . . . 3118 . . . . . . . . . . . . . 3154 . . . . . . . . . . . . . 3160 . . . . . . . . . . . . . 3161 . . . . . . . . . . . . . 3162 . . . . . . . . . . . . . 3163 . . . . . . . . . . . . . 3164 . . . . . . . . . . . . . 3188 . . . . . . . . . . . . 3575 . . . . . . . . . . . . 4028 . . . . . . . . . . . . . 4075 . . . . . . . . . . . . . 4076 . . . . . . . . . . . . . 4077 . . . . . . . . . . . . . 4099 . . . . . . . . . . . . 4112-RC . . . . . . . . . 4124-RD . . . . . . . . . 4622 . . . . . . . . . . . . . 4623 . . . . . . . . . . . . . 4624 . . . . . . . . . . . . . 4625 . . . . . . . . . . . . . 4626 . . . . . . . . . . . . . 4652 . . . . . . . . . . . . . 4721 series . . . . . . . . 4744 . . . . . . . . . . . . . 4755 . . . . . . . . . . . . . 4758 . . . . . . . . . . . . . 4766 . . . . . . . . . . . . . 5007 . . . . . . . . . . . . 5011 . . . . . . . . . . . . A4 A3 A3 K8 K8 K8 K8 E1 D1 D1 D1 D1 D1 D1 K8 K8 K8 K8 K8 K8 K8 K8 K8 K8 J5 J5 J5 J5 J1 J6 J6 J6 J6 J6 J6 J6 D3 K8 J5 A6 A6 A6 K5 K5 K5 J3 J3 J3 J3 J3 J3 J4 J4 J4 J4 J3 H1 H1 8 6 6 87 87 85 85 43 34 34 34 34 34 34 86 86 87 87 87 86 86 86 86 86 75 72 75 75 66 75 76 76 76 76 76 76 38 86 75 10 10 10 80 80 80 69 69 69 69 69 68 70 70 70 70 68 56 56 Part Number Section Page 5027 . . . . . . . . . . . . H2 5050 . . . . . . . . . . . . H2 5053 . . . . . . . . . . . . H1 5066 . . . . . . . . . . . . . H2 5067 . . . . . . . . . . . . . H1 5507 . . . . . . . . . . . C11 5520 . . . . . . . . . . . C10 5543 . . . . . . . . . . . C13 5543-15 . . . . . . . . C13 5558 . . . . . . . . . . . C11 5568 . . . . . . . . . . . C11 5582 . . . . . . . . . . . C10 5582-10 . . . . . . . . C10 5584 . . . . . . . . . . . C10 5586 . . . . . . . . . . . C10 5590 . . . . . . . . . . . C10 5592 . . . . . . . . . . . C10 7014 . . . . . . . . . . . . . H3 7019 . . . . . . . . . . . . . H3 7112 . . . . . . . . . . . . . H4 7124 . . . . . . . . . . . . . H4 7127 . . . . . . . . . . . . . H4 7152 . . . . . . . . . . . . . H4 7157 . . . . . . . . . . . . . H4 7178 . . . . . . . . . . . . . H4 7493 . . . . . . . . . . . . . H7 7493-07 . . . . . . . . . . H7 7496 . . . . . . . . . . . . . H7 7496-04 . . . . . . . . . . H7 7512-04 . . . . . . . . . H6 7700 . . . . . . . . . . . . . H8 7702 . . . . . . . . . . . . . H8 7762 . . . . . . . . . . . . . H8 7769 . . . . . . . . . . . . . H8 7776 . . . . . . . . . . . . . H8 7785 . . . . . . . . . . . . . H8 7785 . . . . . . . . . . . . . L4 7786 . . . . . . . . . . . . . H8 7787 . . . . . . . . . . . . . H8 7792 . . . . . . . . . . . . . H8 7792 . . . . . . . . . . . . . L4 8250 . . . . . . . . . . . C14 8367 . . . . . . . . . . . . B5 8391-A . . . . . . . . . . B5 8391-C . . . . . . . . . . B5 8466 . . . . . . . . . . . . . L5 8486 . . . . . . . . . . . . . L5 8486-05 . . . . . . . . . . L1 8487 . . . . . . . . . . . . . L5 8604 . . . . . . . . . . . . K3 8606 . . . . . . . . . . . . K1 8609 . . . . . . . . . . . . K1 8610 . . . . . . . . . . . . K1 8626 . . . . . . . . . . . . . L5 8628 . . . . . . . . . . . . . L5 8629 . . . . . . . . . . . . . L5 8640 . . . . . . . . . . . . K3 8641 . . . . . . . . . . . . K3 57 57 56 57 56 30 29 32 32 30 30 29 29 29 29 30 30 57 57 60 58 59 59 59 59 61 61 61 61 61 62 62 62 62 62 63 90 62 62 63 90 33 18 18 18 91 91 89 91 78 77 77 77 91 91 91 79 79 Part Number i Section Page 8645 . . . . . . . . . . . . . 8646 . . . . . . . . . . . . 8647 . . . . . . . . . . . . 8715 . . . . . . . . . . . . . 9001 . . . . . . . . . . . . . 9003 . . . . . . . . . . . . . 9023 . . . . . . . . . . . . . 9023-A . . . . . . . . . . . 9035 . . . . . . . . . . . . . 9044 . . . . . . . . . . . . . 9052 . . . . . . . . . . . . . 9055 . . . . . . . . . . . . . 9059 . . . . . . . . . . . . . 9060 . . . . . . . . . . . . 9060 . . . . . . . . . . . . 9075 . . . . . . . . . . . . . 9087 . . . . . . . . . . . . . 9095 . . . . . . . . . . . . . 9096-02 . . . . . . . . . . 9106-02 . . . . . . . . . . 9109 . . . . . . . . . . . . . 9115 . . . . . . . . . . . . . 9118 . . . . . . . . . . . . . 9134 . . . . . . . . . . . . . 9155 . . . . . . . . . . . . . 9162 . . . . . . . . . . . . . 9162-03 . . . . . . . . . . 9165 . . . . . . . . . . . . . 9183 . . . . . . . . . . . . 9183 . . . . . . . . . . . . 9211 . . . . . . . . . . . . . 9212 . . . . . . . . . . . . . 9224 . . . . . . . . . . . . . 9231 . . . . . . . . . . . . . 9238 . . . . . . . . . . . . . 9242 . . . . . . . . . . . . . 9242-01 . . . . . . . . . . 9242-04 . . . . . . . . . . 9242-07 . . . . . . . . . . 9245 . . . . . . . . . . . . . 9251 . . . . . . . . . . . . . 9253 . . . . . . . . . . . . 9264 . . . . . . . . . . . . . 9264-02 . . . . . . . . . . 9270 . . . . . . . . . . . . . 9270-01 . . . . . . . . . . 9276 . . . . . . . . . . . . . 9283 . . . . . . . . . . . . 9500 . . . . . . . . . . . . 9500 . . . . . . . . . . . . . 9513 . . . . . . . . . . . . 9576 . . . . . . . . . . . . 9577 . . . . . . . . . . . . 9579 . . . . . . . . . . . . 9579-02 . . . . . . . . . 9621-01 . . . . . . . . . O R BS EF O ER LE T EN E C FO E R O N LY 407-01 . . . . . . . . . . . 407-03 . . . . . . . . . . . 563 . . . . . . . . . . . . . . 956-3124 . . . . . . . . 956-3125 . . . . . . . . 956-3126 . . . . . . . . 956-3130 . . . . . . . . 956-3134 . . . . . . . . 956-3137 . . . . . . . . 956-4100 . . . . . . . . 956-4104 . . . . . . . . 956-4107 . . . . . . . . 956-4111 . . . . . . . . 956-4113 . . . . . . . . 956-4116 . . . . . . . . 956-4124 . . . . . . . . 956-4138 . . . . . . . . 956-4148 . . . . . . . . 956-4154 . . . . . . . . 956-4198 . . . . . . . . 956-4304 . . . . . . . . 956-4307 . . . . . . . . 956-4311 . . . . . . . . 956-4704 . . . . . . . . 956-5109 . . . . . . . . 956-5307 . . . . . . . . 956-6104 . . . . . . . . 956-7304 . . . . . . . . 1102 . . . . . . . . . . . . . 1102-F . . . . . . . . . . . 1107 . . . . . . . . . . . . . 1107-F . . . . . . . . . . . 1107-M . . . . . . . . . . 1109 . . . . . . . . . . . . . 1110 . . . . . . . . . . . . . 1134 . . . . . . . . . . . . . 1145 . . . . . . . . . . . . . 1156 . . . . . . . . . . . . . 1158 . . . . . . . . . . . . . 1159 . . . . . . . . . . . . . 1160 . . . . . . . . . . . . . 1214 . . . . . . . . . . . . . 1222 . . . . . . . . . . . . . 1232 . . . . . . . . . . . . . 1233 . . . . . . . . . . . . . 1235 . . . . . . . . . . . . . 1236 . . . . . . . . . . . . . 1238 . . . . . . . . . . . . . 1253 . . . . . . . . . . . . . 1254 . . . . . . . . . . . . . 1255 . . . . . . . . . . . . . 1257 . . . . . . . . . . . . . 1258 . . . . . . . . . . . . . 1282 . . . . . . . . . . . . . 1283-325 . . . . . . . . . 1286 . . . . . . . . . . . . . Part Number L5 K3 K4 L5 F5 F5 F1 F1 F4 F1 L2 F5 F4 B3 H8 F4 F5 F1 L3 L3 F4 F1 F5 L2 F1 L1 L1 F2 B3 H8 F2 F1 L1 F1 F1 L1 L1 L1 L1 F1 F5 K3 F5 F5 F5 F5 F2 H3 B3 H6 B2 B3 B2 B2 B2 B3 91 79 79 91 52 52 49 49 51 49 89 52 51 17 63 51 52 48 90 90 50 49 52 89 48 88 88 50 17 63 50 49 88 48 49 88 88 88 88 48 53 79 52 52 52 52 50 58 16 60 14 17 15 14 14 16 Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com index Part Number Section Page 5-Digit Numbers A6 A6 A2 A2 A2 A2 A1 A1 A1 A1 A1 A4 A4 A2 A2 A6 A6 A6 A4 A4 A6 A6 A1 A1 A1 A1 A1 A6 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A3 A1 A1 A3 A4 A4 A4 A4 E1 E1 E1 E1 E1 E1 E1 10 10 5 5 5 5 3 3 4 4 4 7 7 6 6 11 11 11 7 7 10 11 4 4 4 4 4 11 2 2 2 2 2 2 2 2 3 3 2 2 1 1 6 1 2 6 7 7 7 7 42 42 43 42 42 43 42 Section Page 24052 . . . . . . . . . . . H5 24054 . . . . . . . . . . . . H6 24059 . . . . . . . . . . . . E1 24059-08 . . . . . . . . . E1 24060 . . . . . . . . . . . . E1 24063 . . . . . . . . . . . . E1 24063-08 . . . . . . . . . E2 24071 . . . . . . . . . . . . E2 24080 . . . . . . . . . . . . E1 24080-01 . . . . . . . . . E1 24082 . . . . . . . . . . . . E1 24097 . . . . . . . . . . . . E1 24103 . . . . . . . . . . . . E1 24106 . . . . . . . . . . . . E1 24107 . . . . . . . . . . . . E1 24115 . . . . . . . . . . . . E1 24117 . . . . . . . . . . . . E2 24117-01 . . . . . . . . . E2 24124 . . . . . . . . . . . . E1 24143 . . . . . . . . . . . . E1 24144 . . . . . . . . . . . . E1 24200 . . . . . . . . . . . . E1 24400 . . . . . . . . . . . . E1 24401 . . . . . . . . . . . . E1 24401-01 . . . . . . . . . E1 24401-04 . . . . . . . . . E2 24402 . . . . . . . . . . . . E1 24420 . . . . . . . . . . . . E1 24450 . . . . . . . . . . . . E3 24452 . . . . . . . . . . . . . I 24505 . . . . . . . . . . . . D3 24512-03 . . . . . . . . . E3 24512-10 . . . . . . . . . E3 24612-03 . . . . . . . . . E3 24612-10 . . . . . . . . . E3 24612-G13 . . . . . . . . E3 24624-10 . . . . . . . . . E3 24636 . . . . . . . . . . . . E3 24712-S7 . . . . . . . . . E3 24712-GS7 . . . . . . . . E3 24812 . . . . . . . . . . . . E3 24812-01 . . . . . . . . . E3 24812-04 . . . . . . . . . E3 24824-01 . . . . . . . . . E3 24824-04 . . . . . . . . . E3 24836 . . . . . . . . . . . . E3 24848 . . . . . . . . . . . . E3 25100 . . . . . . . . . . . K8 25101 . . . . . . . . . . . K8 25103 . . . . . . . . . . . K8 25104 . . . . . . . . . . . K8 26100 . . . . . . . . . . . K8 26145 . . . . . . . . . . . K8 26152 . . . . . . . . . . . K8 30055 series . . . . . . . J1 30056 series . . . . . . . J1 30062 series . . . . . . . J1 30063 series . . . . . . . J1 60 61 40 40 42 40 43 43 40 40 41 41 42 41 40 40 43 43 40 41 40 41 41 41 41 43 41 41 44 64 37 45 44 45 44 45 44 44 45 45 44 44 44 44 44 44 44 87 87 85 85 86 85 85 65 66 66 66 Part Number Section Page 30090 series . . . . . . . 30128 series . . . . . . . 30147 . . . . . . . . . . . . 30155 . . . . . . . . . . . 30155 . . . . . . . . . . . . 30156 . . . . . . . . . . . 30156 . . . . . . . . . . . . 30171 series . . . . . . . 30172 series . . . . . . . 30200 . . . . . . . . . . . . 30201 . . . . . . . . . . . . 30202 . . . . . . . . . . . . 30204 . . . . . . . . . . . . 30205 . . . . . . . . . . . . 30206 . . . . . . . . . . . . 30219 . . . . . . . . . . . . 30220 . . . . . . . . . . . . 30223 . . . . . . . . . . . . 30238 . . . . . . . . . . . . 30240 . . . . . . . . . . . . 30242 . . . . . . . . . . . . 30243 . . . . . . . . . . . . 30244 . . . . . . . . . . . . 30245 . . . . . . . . . . . . 30401 series . . . . . . . 30402 series . . . . . . . 30403 series . . . . . . . 30404 series . . . . . . . 30407 series . . . . . . . 30408 series . . . . . . . 30409 series . . . . . . . 30410 series . . . . . . . 30507 series . . . . . . . 31017 . . . . . . . . . . . . 31018 . . . . . . . . . . . . 31019 . . . . . . . . . . . . 31100 . . . . . . . . . . . . 31102 . . . . . . . . . . . . 31103 . . . . . . . . . . . . 31200 . . . . . . . . . . . . 31201 . . . . . . . . . . . . 31202 . . . . . . . . . . . . 31203 . . . . . . . . . . . . 31204 . . . . . . . . . . . . 31205 . . . . . . . . . . . . 31230 . . . . . . . . . . . . 31231 . . . . . . . . . . . . 31232 . . . . . . . . . . . . 31233 . . . . . . . . . . . . 31234 . . . . . . . . . . . . 31235 . . . . . . . . . . . . 31236 . . . . . . . . . . . . 31237 . . . . . . . . . . . . 31240 . . . . . . . . . . . . 31241 . . . . . . . . . . . . 31242 . . . . . . . . . . . . 31243 . . . . . . . . . . . . 31244 . . . . . . . . . . . . J2 J1 J5 H8 J5 H8 J5 J1 J1 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J1 J1 J1 J1 J1 J1 J1 J1 J1 J6 J6 J6 J5 J5 J5 J6 J6 J6 J6 J6 J6 J6 J6 J6 J6 J6 J6 J6 J6 J6 J6 J6 J6 J6 67 66 72 63 75 63 75 65 65 73 73 73 73 73 73 74 74 71 74 74 71 71 71 72 66 66 65 66 66 65 65 67 66 76 76 76 73 73 73 76 76 76 76 76 76 75 75 75 75 75 75 75 75 76 76 76 76 76 Part Number Section Page 31245 . . . . . . . . . . . . J6 31246 . . . . . . . . . . . . J6 31301 . . . . . . . . . . . . J5 31302 . . . . . . . . . . . . J5 31304 . . . . . . . . . . . . J5 31305 . . . . . . . . . . . . J5 31321 . . . . . . . . . . . . J5 31322 . . . . . . . . . . . . J5 31323 . . . . . . . . . . . . J5 31324 . . . . . . . . . . . . J5 31325 . . . . . . . . . . . . J5 31340 . . . . . . . . . . . . J5 31341 . . . . . . . . . . . . J5 31728 . . . . . . . . . . . . J5 31729 . . . . . . . . . . . . J5 31731 . . . . . . . . . . . . J5 31732 . . . . . . . . . . . . J5 31734 . . . . . . . . . . . . J5 31735 . . . . . . . . . . . . J5 31736 . . . . . . . . . . . . J5 31737 . . . . . . . . . . . . J5 31738 . . . . . . . . . . . . J5 31739 . . . . . . . . . . . . J5 31784 . . . . . . . . . . . . A6 40100 . . . . . . . . . . . K5 40102 . . . . . . . . . . . H3 40103 . . . . . . . . . . . H3 40151 . . . . . . . . . . . K5 40212 . . . . . . . . . . . K5 46206-04 . . . . . . . . . J4 46210-02 . . . . . . . . D3 46210-03 . . . . . . . . D3 46211-01 . . . . . . . . D3 46211-R . . . . . . . . . D3 46377 series . . . . . . . J3 48000 . . . . . . . . . . . . . . I 48051 . . . . . . . . . . . D4 48070 . . . . . . . . . . . . D4 48080 . . . . . . . . . . . . D4 48090 . . . . . . . . . . . . D4 48092 . . . . . . . . . . . . D4 48120 . . . . . . . . . . . . D4 48122 . . . . . . . . . . . . D4 48160 . . . . . . . . . . . . D4 48161 . . . . . . . . . . . . D4 48162 . . . . . . . . . . . . D4 48510 . . . . . . . . . . . . D5 48600 . . . . . . . . . . . . . . I 48785 . . . . . . . . . . . . E4 48810-01 . . . . . . . . . . . I 48811-01 . . . . . . . . . . . I 48812-01 . . . . . . . . . . . I 50001 . . . . . . . . . . . H1 50002 . . . . . . . . . . . . H1 50031 . . . . . . . . . . . . H1 50036 . . . . . . . . . . . . H3 50046 . . . . . . . . . . . . H1 50066 . . . . . . . . . . . . H1 76 76 74 74 74 74 74 74 74 74 74 74 74 71 71 72 74 74 74 74 74 74 72 11 80 58 58 80 80 71 37 37 37 38 68 64 39 38 38 39 38 39 38 39 39 38 39 64 45 64 64 64 57 57 56 58 57 57 O R BS EF O ER LE T EN E C FO E R O N LY 11011 . . . . . . . . . . . . 11017 . . . . . . . . . . . . 11041 . . . . . . . . . . . . 11041-06 . . . . . . . . . 11042 . . . . . . . . . . . . 11042-05 . . . . . . . . . 11100-01 . . . . . . . . . 11101-02 . . . . . . . . . 11127 . . . . . . . . . . . . 11127-05 . . . . . . . . . 11128 . . . . . . . . . . . . 11134 . . . . . . . . . . . . 11135 . . . . . . . . . . . . 11156 . . . . . . . . . . . . 11157 . . . . . . . . . . . . 11164 . . . . . . . . . . . . 11165 . . . . . . . . . . . . 11167 . . . . . . . . . . . . 11172 . . . . . . . . . . . . 11173 . . . . . . . . . . . . 11178 . . . . . . . . . . . . 11187 . . . . . . . . . . . . 11216-04 . . . . . . . . . 11216-05 . . . . . . . . . 11217-06 . . . . . . . . . 11247-01 . . . . . . . . . 11247-02 . . . . . . . . . 11750 . . . . . . . . . . . . 12063 . . . . . . . . . . . . 12063-01 . . . . . . . . . 12075 . . . . . . . . . . . . 12075-01 . . . . . . . . . 12077-01 . . . . . . . . . 12080 . . . . . . . . . . . . 12080-01 . . . . . . . . . 12080-11 . . . . . . . . . 12081 . . . . . . . . . . . . 12082 . . . . . . . . . . . . 12091 . . . . . . . . . . . . 12092 . . . . . . . . . . . . 12300 . . . . . . . . . . . . 12301 . . . . . . . . . . . . 12302 . . . . . . . . . . . . 12310 . . . . . . . . . . . . 12311 . . . . . . . . . . . . 12312 . . . . . . . . . . . . 12400 . . . . . . . . . . . . 12401 . . . . . . . . . . . . 12500 . . . . . . . . . . . . 12501 . . . . . . . . . . . . 24021 . . . . . . . . . . . . 24022 . . . . . . . . . . . . 24023 . . . . . . . . . . . . 24037 . . . . . . . . . . . . 24044 . . . . . . . . . . . . 24046 . . . . . . . . . . . . 24047 . . . . . . . . . . . . Part Number Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com ii index Part Number Section Page 56 58 56 57 58 26 26 26 26 26 26 26 26 24 24 24 24 24 24 29 29 29 32 29 30 30 30 29 29 30 30 29 33 30 29 30 29 30 30 29 30 32 32 30 30 32 30 22 23 22 22 23 23 24 24 22 20 23 Section Page 56300-11 . . . . . . . . C3 56327-01 . . . . . . . . C1 56327-06 . . . . . . . . C1 57000-01 . . . . . . . . C3 57000-02 . . . . . . . . C3 57000-04 . . . . . . . . C3 57000-23 . . . . . . . . C2 57000-33 . . . . . . . . C2 57001-01 . . . . . . . . C3 57002-01 . . . . . . . . C3 57003-01 . . . . . . . . C3 57003-02 . . . . . . . . C3 57005-11 . . . . . . . . . C2 57006-01 . . . . . . . . C3 57006-02 . . . . . . . . C3 57007-01 . . . . . . . . C3 57007-07 . . . . . . . . C3 57007-08 . . . . . . . . C3 57007-11 . . . . . . . . C3 57013-08 . . . . . . . . C2 57300-01 . . . . . . . . C3 57300-02 . . . . . . . . C3 57300-03 . . . . . . . . C3 57300-10 . . . . . . . . C3 58007-04 . . . . . . . . C3 58027-01 . . . . . . . . C1 58027-02 . . . . . . . . C1 58027-03 . . . . . . . . C1 58027-04 . . . . . . . . C1 58027-06 . . . . . . . . C1 58027-07 . . . . . . . . C1 58027-11 . . . . . . . . C1 58027-18 . . . . . . . . C1 58326-01 . . . . . . . . C1 58326-11 . . . . . . . . C1 58326-12 . . . . . . . . C1 58326-21 . . . . . . . . C1 58326-24 . . . . . . . . C1 58326-25 . . . . . . . . C1 58326-27 . . . . . . . . C1 58326-29 . . . . . . . . C1 58327-01 . . . . . . . . C1 58327-06 . . . . . . . . C1 58328-01 . . . . . . . . C1 58328-02 . . . . . . . . C1 58328-04 . . . . . . . . C1 58328-05 . . . . . . . . C1 58328-06 . . . . . . . . C1 58328-07 . . . . . . . . C1 58328-08 . . . . . . . . C1 58328-09 . . . . . . . . C1 58328-10 . . . . . . . . C1 58328-11 . . . . . . . . C1 58328-12 . . . . . . . . C1 58328-13 . . . . . . . . C1 58328-14 . . . . . . . . C1 58328-15 . . . . . . . . C1 58328-16 . . . . . . . . C1 23 20 20 22 23 22 22 22 22 23 23 23 22 24 24 23 23 23 23 22 23 23 23 23 24 20 20 20 20 20 21 21 21 21 21 21 21 21 21 21 21 20 20 19 19 19 20 20 20 19 19 19 19 19 19 19 19 19 Part Number Section Page 58328-17 . . . . . . . . C1 58328-18 . . . . . . . . C1 58328-19 . . . . . . . . C1 58328-20 . . . . . . . . . C1 58328-21 . . . . . . . . C1 58328-22 . . . . . . . . C1 58328-25 . . . . . . . . C1 58328-26 . . . . . . . . C1 58328-33 . . . . . . . . C1 58328-34 . . . . . . . . C1 58328-35 . . . . . . . . C1 58328-36 . . . . . . . . C1 58328-39 . . . . . . . . C1 58328-40 . . . . . . . . C1 58328-47 . . . . . . . . C1 58328-48 . . . . . . . . C1 58328-49 . . . . . . . . C1 58328-50 . . . . . . . . C1 58328-51 . . . . . . . . C1 58328-100 . . . . . . . C1 58328-101 . . . . . . . C1 58328-102 . . . . . . . C1 58328-103 . . . . . . . C1 58328-104 . . . . . . . C1 58506-07 . . . . . . . . C4 58506-08 . . . . . . . . C4 58506-09 . . . . . . . . C4 58506-11 . . . . . . . . C4 59024-12 . . . . . . . . C8 59024-13 . . . . . . . . C8 59024-14 . . . . . . . . C8 59024-144 . . . . . . . C7 59024-15 . . . . . . . . C8 59024-16 . . . . . . . . C8 59024-33 . . . . . . . . C8 59024-34 . . . . . . . . C8 59024-35 . . . . . . . . C8 59024-36 . . . . . . . . C8 59024-37 . . . . . . . . C8 59024-38 . . . . . . . . C8 59024-100 . . . . . . . C7 59024-101 . . . . . . . C7 59024-102 . . . . . . . C7 59024-104 . . . . . . . C7 59024-106 . . . . . . . C7 59024-108 . . . . . . . C7 59024-110 . . . . . . . C7 59024-116 . . . . . . . C7 59024-118 . . . . . . . C7 59024-200 . . . . . . . C7 59024-201 . . . . . . . C7 59024-202 . . . . . . . C7 59024-204 . . . . . . . C7 59024-206 . . . . . . . C7 59024-208 . . . . . . . C7 59024-210 . . . . . . . C7 59024-216 . . . . . . . C7 59024-218 . . . . . . . C7 19 19 19 19 19 19 20 20 20 20 20 20 20 20 20 20 20 20 20 19 19 19 20 20 24 24 24 24 28 28 28 27 28 28 28 28 28 28 28 28 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 Part Number iii Section Page 59024-244 . . . . . . . C7 59071 . . . . . . . . . . C13 66028 . . . . . . . . . . . . H3 68003 . . . . . . . . . . . . L6 68362 . . . . . . . . . . . H7 68363 . . . . . . . . . . . . H7 71016 . . . . . . . . . . . . H4 71033-02 . . . . . . . . . H4 71042 . . . . . . . . . . . . H4 71092 . . . . . . . . . . . . H4 71092-02 . . . . . . . . . H4 72023-01 . . . . . . . . . H5 72079-01 . . . . . . . . . H5 72100 . . . . . . . . . . . . H4 72101 . . . . . . . . . . . . H4 74600-02 . . . . . . . . . G3 74600-09 . . . . . . . . . G3 74601-01 . . . . . . . . . G3 74603 . . . . . . . . . . . . G3 75125 . . . . . . . . . . . . L2 75212-04 . . . . . . . . . G2 75217-04 . . . . . . . . . G2 75221-06 . . . . . . . . . G2 75221-09 . . . . . . . . . G2 75226 . . . . . . . . . . . . G2 75228-03 . . . . . . . . . G2 75228-04 . . . . . . . . . G2 75236 . . . . . . . . . . . . G2 75600 . . . . . . . . . . . . G1 75600-01 . . . . . . . . . G1 75600-02 . . . . . . . . . G1 75600-04 . . . . . . . . . G1 75600-05 . . . . . . . . . G1 75600-07 . . . . . . . . . G1 75601-02 . . . . . . . . . G1 75601-08 . . . . . . . . . G1 75602-02 . . . . . . . . . G1 75602-04 . . . . . . . . . G1 75705-01 . . . . . . . . B3 75705-01 . . . . . . . . . H6 75903 . . . . . . . . . . . . D1 75904 . . . . . . . . . . . . D1 75904-01 . . . . . . . . . D1 75904-02 . . . . . . . . . D1 75904-03 . . . . . . . . . D1 75907 . . . . . . . . . . . . D1 75908 . . . . . . . . . . . . D1 75912 . . . . . . . . . . . . D1 80101-B . . . . . . . . . . D3 81192 . . . . . . . . . . . . A6 81255 . . . . . . . . . . C14 81261 . . . . . . . . . . C14 81262 . . . . . . . . . . C14 81263 . . . . . . . . . . C14 81264 . . . . . . . . . . C14 81264-01 . . . . . . . C14 81271 . . . . . . . . . . C14 81272 . . . . . . . . . . C14 O R BS EF O ER LE T EN E C FO E R O N LY 50070 . . . . . . . . . . . . H1 50071 . . . . . . . . . . . . H3 50077 . . . . . . . . . . . . H1 50082 . . . . . . . . . . . . H2 50203 . . . . . . . . . . . . H3 54100 . . . . . . . . . . . C6 54101-01 . . . . . . . . C6 54103 . . . . . . . . . . . C6 54104 . . . . . . . . . . . C6 54105 . . . . . . . . . . . C6 54107 . . . . . . . . . . . C6 54109 . . . . . . . . . . . C6 54110 . . . . . . . . . . . C6 54201-01 . . . . . . . . C4 54203-01 . . . . . . . . C4 54204-01 . . . . . . . . C4 54300-01 . . . . . . . . C4 54401-01 . . . . . . . . C4 54403-01 . . . . . . . . C4 55014 . . . . . . . . . . C10 55014-05 . . . . . . . C10 55015 . . . . . . . . . . C10 55015-03 . . . . . . . C13 55016 . . . . . . . . . . C10 55017 . . . . . . . . . . C10 55018 . . . . . . . . . . C10 55019 . . . . . . . . . . C10 55020 . . . . . . . . . . C10 55020-04 . . . . . . . C10 55021 . . . . . . . . . . C10 55021-07 . . . . . . . C10 55023 . . . . . . . . . . C10 55023-10 . . . . . . . C14 55033-01 . . . . . . . C10 55036 . . . . . . . . . . C10 55046 . . . . . . . . . . C10 55052 . . . . . . . . . . C10 55054 . . . . . . . . . . C10 55054-04 . . . . . . . C10 55055 . . . . . . . . . . C10 55057 . . . . . . . . . . C10 55058-01 . . . . . . . C13 55064 . . . . . . . . . . C13 55065-02 . . . . . . . C10 55065-03 . . . . . . . C10 55071 . . . . . . . . . . C13 55088 . . . . . . . . . . C10 56000-01 . . . . . . . . C3 56000-02 . . . . . . . . C3 56001-01 . . . . . . . . C3 56001-04 . . . . . . . . C2 56002-01 . . . . . . . . C3 56003-01 . . . . . . . . C3 56006-01 . . . . . . . . C3 56006-02 . . . . . . . . C3 56006-04 . . . . . . . . C2 56027-01 . . . . . . . . C1 56300-01 . . . . . . . . C3 Part Number 27 32 58 91 61 61 59 60 60 59 59 60 60 58 59 56 56 56 56 89 55 55 55 55 55 55 55 55 54 55 54 54 54 54 55 55 55 54 16 61 35 35 35 35 35 35 34 35 37 10 33 33 33 33 33 33 33 33 Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com index Part Number Section Page 33 55 55 10 37 37 25 25 25 25 25 33 33 50 50 50 50 18 18 18 18 18 18 18 18 18 37 18 18 90 18 18 77 77 77 68 77 78 78 78 78 78 68 25 61 48 48 48 48 49 51 51 51 51 89 53 53 53 Section Page 91804 . . . . . . . . . . . . 91811 . . . . . . . . . . . . 91812 . . . . . . . . . . . . 91822 . . . . . . . . . . . . 91823 . . . . . . . . . . . . 92007 . . . . . . . . . . . 92102 . . . . . . . . . . . . 92105 . . . . . . . . . . . . 92107-04 . . . . . . . . . 95060 . . . . . . . . . . . 95060-01 . . . . . . . . 95060-02 . . . . . . . . 95060-03 . . . . . . . . 95060-04 . . . . . . . . 95060-05 . . . . . . . . 95060-06 . . . . . . . . 95060-07 . . . . . . . . 95400 . . . . . . . . . . . 95408 . . . . . . . . . . . 95410 . . . . . . . . . . . 95512-A . . . . . . . . . 95514-A . . . . . . . . . 95515-A . . . . . . . . . 95520-B . . . . . . . . . 95521-B . . . . . . . . . 95522-A . . . . . . . . . 95524-A . . . . . . . . . 95525-A . . . . . . . . . 95532 . . . . . . . . . . . 95534 . . . . . . . . . . . 95535 . . . . . . . . . . . 95539 . . . . . . . . . . . 95582 . . . . . . . . . . . 95610 . . . . . . . . . . . 95612 . . . . . . . . . . . 95614 . . . . . . . . . . . 96100 . . . . . . . . . . . . 96101 . . . . . . . . . . . . 96102 . . . . . . . . . . . . 97298 . . . . . . . . . . . 97846-A . . . . . . . . . 97846-B . . . . . . . . . 98628 . . . . . . . . . . . 98635-01 . . . . . . . . 98635-03 . . . . . . . . 98647 . . . . . . . . . . . . 99025 . . . . . . . . . . . . 99026 . . . . . . . . . . . . 90043 . . . . . . . . . . . . 11100-01 . . . . . . . . . 11100-02 . . . . . . . . . 11127-05 . . . . . . . . . 11134-08 . . . . . . . . . 11216-04 . . . . . . . . . 11216-05 . . . . . . . . . 11217-06 . . . . . . . . . 11247-01 . . . . . . . . . 11247-02 . . . . . . . . . F5 F5 F5 F5 F5 K3 L1 L1 L1 B4 B4 B4 B4 B4 B4 B4 B4 B3 B3 B3 B2 B2 B2 B3 B2 B2 B2 B2 B2 B2 B2 B3 B2 B2 B2 B3 F4 F4 F4 B5 D3 D3 C5 B5 B5 A6 E5 E5 F1 A1 A1 A1 A4 A1 A1 A1 A1 A1 53 53 53 54 54 79 88 88 88 17 17 17 17 17 17 17 17 16 16 16 15 14 14 15 14 15 14 14 15 14 14 15 14 14 14 17 51 51 51 18 37 37 25 18 18 10 47 47 49 3 3 4 7 4 4 4 4 4 Part Number Section Page 12063-01 . . . . . . . . . 12075-01 . . . . . . . . . 12077-01 . . . . . . . . . 12080-01 . . . . . . . . . 12080-11 . . . . . . . . . 11041-06 . . . . . . . . . 11042-05 . . . . . . . . . A1 A1 A1 A1 A1 A2 A2 2 2 2 2 1 5 5 C12 C12 C12 C12 C12 C12 C12 C12 C12 C12 C12 C12 C12 C12 C12 C12 C12 C12 C12 C12 C12 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 31 6 Digit Numbers 551000 . . . . . . . . . 551001 . . . . . . . . . 551800 . . . . . . . . . 551801 . . . . . . . . . 551802 . . . . . . . . . 551805 . . . . . . . . . 551806 . . . . . . . . . 551840 . . . . . . . . . 551841 . . . . . . . . . 551842 . . . . . . . . . 551843 . . . . . . . . . 551844 . . . . . . . . . 551845 . . . . . . . . . 551846 . . . . . . . . . 551849 . . . . . . . . . 551850 . . . . . . . . . 551851 . . . . . . . . . 551852 . . . . . . . . . 551855 . . . . . . . . . 551861 . . . . . . . . . 551862 . . . . . . . . . Part Number Section Page M-451 . . . . . . . . . . . K7 M-456 . . . . . . . . . . . J4 M-458 . . . . . . . . . . . K7 M-594 . . . . . . . . . . C12 M-606 . . . . . . . . . . . H1 M-608 . . . . . . . . . . . F1 M-641-01 . . . . . . . . . J3 M-643-01 . . . . . . . . . J3 M-645-01 . . . . . . . . . J3 M-647-01 . . . . . . . . . J3 M-674 . . . . . . . . . . . J3 M-750 . . . . . . . . . . . D2 M-751 . . . . . . . . . . . D2 M-752 . . . . . . . . . . . D2 M-753 . . . . . . . . . . . D2 M-754 . . . . . . . . . . . D2 M-754-01 . . . . . . . . D2 M-755 . . . . . . . . . . . D2 M-755-01 . . . . . . . . D2 M-832 . . . . . . . . . . . B3 M-850 . . . . . . . . . . . B3 M-54111-01 . . . . . . C9 M-54111-02 . . . . . . C9 M-58031-01 . . . . . . C1 M-58031-02 . . . . . . C1 M-58031-04 . . . . . . C1 M-58031-06 . . . . . . C1 M-58031-07 . . . . . . C1 MA-150000 series . . E5 MA-250000 series . . E5 PL-1 series . . . . . . . K6 PL-2 series . . . . . . . K6 PL-5-RC . . . . . . . . . K6 PL-6 series . . . . . . . K6 PL-16 series . . . . . . K6 PL-19 series . . . . . . K6 PL-20 series . . . . . . K6 PL-35 series . . . . . . K6 PL-36 series . . . . . . K6 PL-85 series . . . . . . K6 PL-86 series . . . . . . K6 PL-116 series . . . . . K6 PL-118 series . . . . . K6 PL-612 series . . . . . K6 RA-400000 series . . . E5 RA-700000 series . . . E5 84 70 84 31 57 49 69 69 69 69 68 36 36 36 36 36 36 36 36 15 15 28 28 21 21 21 21 21 47 47 82 81 82 81 83 82 82 83 82 83 83 82 81 81 47 47 O R BS EF O ER LE T EN E C FO E R O N LY 81273 . . . . . . . . . . C14 81298-02 . . . . . . . . . G2 81298-34 . . . . . . . . . G2 81356 . . . . . . . . . . . . A6 82065 . . . . . . . . . . . . D3 82065-02 . . . . . . . . . D3 82159-02 . . . . . . . . C5 82159-03 . . . . . . . . C5 82159-1 . . . . . . . . . C5 82159-2 . . . . . . . . . C5 82159-3 . . . . . . . . . C5 82468 . . . . . . . . . . C14 83252 . . . . . . . . . . C14 83280 . . . . . . . . . . . . F3 83280-02 . . . . . . . . . F3 83280-03 . . . . . . . . . F3 83280-05 . . . . . . . . . F3 83285-01 . . . . . . . . B5 83288 . . . . . . . . . . . B5 83295-A . . . . . . . . . B5 83296 . . . . . . . . . . . B5 83321-A . . . . . . . . . B5 83337 . . . . . . . . . . . B5 83346 . . . . . . . . . . . B5 83348 . . . . . . . . . . . B5 83353 . . . . . . . . . . . B5 83353 . . . . . . . . . . . D3 83357 . . . . . . . . . . . B5 83373 . . . . . . . . . . . B5 83377 . . . . . . . . . . . . L2 83379 . . . . . . . . . . . B5 83406 . . . . . . . . . . . B5 84229 . . . . . . . . . . . K1 84236 . . . . . . . . . . . K1 84248 . . . . . . . . . . . K1 86126 series . . . . . . . J2 86263 . . . . . . . . . . . K1 86272 . . . . . . . . . . . K1 86279 . . . . . . . . . . . K1 86281 . . . . . . . . . . . K1 86283 . . . . . . . . . . . K1 86284 . . . . . . . . . . . K1 87128 series . . . . . . . J2 87167-01 . . . . . . . . C5 90005-03 . . . . . . . . H6 90030 . . . . . . . . . . . . F1 90030-01 . . . . . . . . . F1 90030-04 . . . . . . . . . F1 90036-02 . . . . . . . . . F1 90043 . . . . . . . . . . . . F1 90047 . . . . . . . . . . . . F4 90047-01 . . . . . . . . . F4 90048 . . . . . . . . . . . . F4 90048-01 . . . . . . . . . F4 91113 . . . . . . . . . . . . L2 91800 . . . . . . . . . . . . F5 91801 . . . . . . . . . . . . F5 91801-01 . . . . . . . . . F5 Part Number Alphanumeric Numbers DL-3 . . . . . . . . . . . . DL-13 . . . . . . . . . . . DL-21 . . . . . . . . . . . DL-75-12V . . . . . . . M-114 . . . . . . . . . . . M-115 . . . . . . . . . . . M-118 . . . . . . . . . . . M-121 . . . . . . . . . . . M-284 . . . . . . . . . . . M-284-01 . . . . . . . . M-284-02 . . . . . . . . M-284-A . . . . . . . . . M-290-05 . . . . . . . . M-326 series . . . . . M-412 . . . . . . . . . . . M-413 . . . . . . . . . . . M-414 . . . . . . . . . . . M-414-01 . . . . . . . . . M-415 . . . . . . . . . . . M-415-01 . . . . . . . . . M-426 . . . . . . . . . . . M-427 . . . . . . . . . . . M-428 . . . . . . . . . . . M-429 . . . . . . . . . . . M-448 . . . . . . . . . . . M-449 . . . . . . . . . . . Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com K7 K7 K7 K7 A4 A4 A4 A4 D1 D1 D1 D1 D1 K6 J3 J3 J3 J3 J3 J3 J4 J4 J4 J4 J4 J4 84 84 84 84 8 8 8 9 34 34 34 34 35 83 69 69 69 69 69 69 69 69 70 70 71 71 iv What's New? LED Pilot Lights, PL-612 Series Master Disconnect Switch 75912 Light never needs replacing. Bezel protects LED from damage, and reflects more light! See page 81 Here's the switch for situations where regulations demand that positive and negative are both turned off. It's also useful for switching two high current electrical loads. See page 35 Forward & Reverse Module 24452 Locking Switch 58336 Motor Reversing Solenoid 24450 Sealed Key Switches, 95060 Series O R BS EF O ER LE T EN E C FO E R O N LY Able to handle a hefty current up to 70A, this module is perfect for a multitude of applications. Includes dynamic braking! See page 64 Simple to use, this rocker switch automatically locks in the off position, and needs an extra step to release. See page 22 Two solenoids in one, this compact unit is just one of Cole Hersee's many solutions for control of forward and reverse. See page 44 A complete series of switches that are suitable for many uses, including ignition. See page 22 SureStartTM Low Voltage Disconnect Switch, 48510 Series Two-Pole Power Take-Off 11041-06 Automatically disconnects less important electrical loads when battery voltage falls to a level that won't allow the engine to start. Automatically reconnects when battery level is safe. See section D5, page 39 Provides a high integrity two circuit path. Commonly used in on-road and off-road vehicles. See page 5 Cole Hersee switches. Always lots of choices. Rapid ship item. v BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com vehicle connectors A1 tractor-trailer connectors Heavy duty sockets, plugs and assemblies that withstand the rigors of trucking thousands of miles in dust and dirt, rain and snow, heat and cold, yet maintain the all-important electrical continuity between tractor unit and trailer. With the increased need for more circuits on the trailer comes the need for more poles in the connectors. The 13-pole connector contains added circuits, yet is able to link up with standard 7-pole trailers when necessary. Green connectors clearly indicate dedicated ABS plugs and sockets, yellow identifies a 13-pole connector. Tractortrailer connectors are also employed in agricultural vehicles. 13-Pole Connectors 7-Pole Connectors Sockets and plugs conform to ATA, RCCC (RP-102), SAE (J560b), FMVSS-121, FIEI TTMA (RP 40-73) standards or recommendations, and are compatible with other standard (J560b) connectors. Sockets Ground terminal accepts wires up to 8AWG, other terminals up to 10AWG. Solid brass contacts are aligned to assure proper contact and minimal voltage dr op. Wiring codes are embossed on the insulator. The door is spring-loaded and fits over a mating ridge on the socket face to minimize penetration of dirt and moisture. Housings are constructed from corrosion-resistant diecast metal or rugged glass-filled plastic. Contacts are either self-grounding or insulated. See page 6 for socket interiors. 3 Mounting Holes O R BS EF O ER LE T EN E C FO E R O N LY Provides six additional tractor-trailer circuits within the dimensions of traditional 7-pole connectors. Adaptable to a wide variety of wiring combinations, including multiplexed circuits. Surpasses SAE J560b performance standards. Conforms to this standard for interchangeability between 7-pole and 13-pole connectors. Distinctive bright yellow identifies 13-pole connectors. Robust glass-filled plastic housings cannot rust or corrode. Ground terminals accept up to 8AWG wire, 7 pole terminals up to 10AWG, smaller 6 pole terminals up to 14AWG. A 12300, Socket Gasket-sealed socket door is spring-loaded and locks onto the plug. Solid brass contact pins. Rain hood extends beyond the pins to protect the interior. The 5 downward pitch drain channel inside the socket reduces water retention. Three mounting holes on the flange: .33" (8.4mm) diameter, 2.93" (74.6mm) on centers. Includes six 31784 crimp-on connectors to mate with the six smaller pole terminals. 81356 Rubber Boot gives added protection to the terminals. Not included. See page 10. 12301, Plug Plug locks into the socket, utilizing the spring-loaded socket door. Spring-grip contacts have self-adjusting spring bands to maintain long-term uniform electrical contact with socket pins. O-ring at the plug end prevents water from reaching the contacts. Strain relief and grommet seal isolates the contacts from mechanical strain, and provides extra moisture protection. Cable retainer maintains secure cable connection. Replaceable interior. Includes six 31784 crimp-on connectors to mate with the six smaller pole terminals. 12310, High-Performance Socket Surpasses SAE J560b performance standards. Accepts all seven-pole plugs conforming to SAE J560b or Cole Hersee 13-pole plug 12301. Superior environmental protection gives extended product life. Glass-filled plastic housing cannot rust or corrode. Gasket-sealed socket door is spring-loaded and locks onto the plug. Solid brass contact pins. Rain hood extends beyond the pins to protect the interior: drain channel inside the socket has drain channel at 5 downward pitch to reduce water retention. Three mounting holes on the flange: .33" (8.4mm) diameter, 2.93" (74.6mm) on centers. 81356 Rubber Boot gives added protection to the terminals. Not included. See page 10. 12080-11, ABS Color-fast green glass-filled plastic insures quick identification. Spring-loaded door is marked `Trailer ABS' to further lessen any chance of misconnection. Mounting holes on the flanges are oval, .488" x .328" (12.4 x 8.3mm), 2.93" (74.6mm) on centers. Mounts through 2" (50.8mm) diameter hole. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 1 vehicle connectors A 2 Mounting Holes Plugs 12080, Glass-Filled Plastic, Insulated Mounting holes on the flanges are oval, .488" x .328" (12.4 x 8.3mm), 2.93" (74.6mm) on centers. Mounts through 2" (50.8mm) diameter hole. Black plastic. Ground terminal accepts wires up to 8AWG, other terminals up to 10AWG. Cable protectors are constructed of plated steel, and provide strain relief and protection against abrasion. Plug Interiors. See page 6. 12311, High-Performance Plug Surpasses SAE J560b performance standards. Superior environmental protection gives extended product life. Black glass-filled plastic housing cannot rust or corrode. Plug locks onto opening on spring-loaded socket door. Spring-grip contacts have self-adjusting spring bands to maintain long-term uniform electrical contact with socket pins. O-ring at the plug end prevents water from reaching the contacts. Strain relief and grommet seal isolates the contacts from mechanical strain, and provides extra moisture protection. Cable retainer maintains secure cable connection. Replaceable interior. Connects with all SAE J560b sockets, and Cole Hersee 13-pole sockets. 12080-01, Glass-Filled Plastic, Insulated, Split Pins Same as 12080, but with split-pin contacts. O R BS EF O ER LE T EN E C FO E R O N LY 12063, Diecast, Self-Grounding Mounting holes on the flanges are oval, .488" x .328" (12.4 x 8.3mm), 2.93" (74.6mm) on centers. Mounts through 2" (50.8mm) diameter hole. 12063-01, Diecast, Self-Grounding, Split Pins Same as 12063, but with split-pin contacts. With Quick Release Plug Interiors Interiors can be readily removed by loosening the single set screw in the cable clamp, and then depressing on the spring clip release with a screwdriver. The interior then readily slides out. The interior slides back into the housing and locks securely into place with a high-tension metal clip. After the cable clamp is tightened, the plug is ready for use. 12075, Diecast, Insulated Mounting holes on the flanges : 5/16" (7.9mm) diameter, 4 1/2" (114.3mm) on centers, with additional knockouts 2 15/16" (74.7mm) on centers. Mounts through 2 5/8" (58.7mm) through 3 7/8" (98.4mm) diameter hole. 12091, Diecast 12075-01, Diecast, Insulated, Split Pins Same as 12075, but with split-pin contacts. 12077-01, For ISO Type Diecast housing, polarized ground terminal, insulated. Replacement for ISO 3731-1976 (E) road vehicles, type 24S (supplementary). Contact pins: one spring-grip female, and six solid male. Mounting holes on the flanges are oval, .488" x .328" (12.4 x 8.3mm), 2.93" (74.6mm) on centers. Mounts through 2" (50.8mm) diameter hole. Mates with Cole Hersee 11100-02 and 11100-01 plugs. Rapid ship item. 2 BP Available in retail clamshell pack. 12092, Diecast, with Cable Protector Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com vehicle connectors 12081, Glass-Filled Plastic A 11100-01, ISO Type Diecast housing, polarized ground terminal, insulated. Replacement for ISO 3731-1976 (E) road vehicles, type 24S (supplementary). Contacts: six spring-grip female, and one solid male pin. Mates with Cole Hersee 12077-01 ISO socket. 12082, Glass-Filled Plastic, with Cable Protector O R BS EF O ER LE T EN E C FO E R O N LY 11100-02, ISO Type, with Cable Protector Same as 11100-01, except with cable protector. With Spring Grip Electrical Contacts Cole Hersee spring grip contacts contain a self-adjusting spring band that maintains contact pressure from socket to pin. Greater contact pressure not only gives greater electrical efficiency, but also makes coupling and uncoupling uniform, and minimizes buildup of dirt. In competitive plugs, conventional contacts tend to widen after repeated use: the Cole Hersee plug has individually sprung sockets to insure maximum contact year after year. Diecast metal housing. Replaceable interior. Wiring codes are identified on the insulator. Cable clamp holds all wires securely. 1222 7-pole Brown - Right turn and brake lights Red - Left turn and brake lights Green - Taillights and clearance lights Yellow - Auxiliary White - Ground Blue - Electric trailer brakes Black - Auxiliary Power/Battery Charge SAE coding convention for 7-pole connectors 1255, With Cable Protector Same as 1222, except with cable protector. Wire Color Coductor Number Cole Hersee Terminal Marking White 1 W Black 2 BK Yellow 3 Y Red 4 R Green 5 G Brown 6 BR Blue 7 BL Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Function Ground return to towing vehicle Clearance, side marker, and identification lamps Left turn signal and hazard lamps Stop lamps and antilock device Right turn signal and hazard lamps Tail and license plate lamps Continuous ABS power/Auxiliary Minimum order quantity may apply. 3 vehicle connectors A Assemblies A2 1-6 pole connectors Available with one or two plastic or diecast metal plugs. Conform to ATA, RCCC, SAE and TTMA standards. Superior coil memory minimizes snagging, small diameter coil reduces tangling with other lines. Temperature-resistant coil will not crack or stiffen at -70F (-57C). Cable jacketing is abrasion- and cut-resistant, repels oil, gas and chemicals. 100% electrical copper conductors give maximum conductivity. Six 12AWG and one 10AWG wires. Normally used with a trailer where limited functionality (taillights, brake lights) is needed. Ideal for boat trailers, or RVs towing a car on a flatbed trailer. See also 'In-Line Trailer Connectors' on page 7 for a different kind of connector. Diecast metal housings. Screw terminals accept up to 12AWG wire. Replaceable interiors. Sockets Coiled Cable Brass split-pin contacts are aligned to assure proper contact and minimal voltage drop. Spring-loaded socket doors, plug locks securely into the opening. Wiring codes are identified on the insulator. Two mounting holes on the flange 17/64" (6.7mm) diameter, 2 15/16" (74.6mm) on centers. Mount through 1 3/8" (34.9mm) diameter hole. 12ft working length 1258, 6-Pole Exposed terminal screws. O R BS EF O ER LE T EN E C FO E R O N LY 11216-04, Two Metal Plugs With two 1222 plugs: metal housings, spring grip electrical contacts. 11247-01, Two Metal Plugs With two 12092 plugs: metal housings, quick-release plug interiors and cable protectors. 1235, 6-Pole, Protective Housing Same as 1258, but with special housing that protects terminals from roadsplash. 11216-05, One Metal Plug With one 12091 plug: metal housing, quick-release plug interior. 11217-06, One Metal Plug With one 12092 plug: metal housing, quick-release plug interior and cable protector. 11247-02, Two Plastic Plugs With two 12082 plugs: glass-filled plastic housings, quick-release plug interiors and cable protectors. Straight Cable 1257, 4-Pole Same as 1232, but with exposed terminal screws. 10' 8" long (3.25m) 11127, Two Metal Plugs With two 1255 plugs: metal housings, spring grip electrical contacts and cable protectors. Plugs 11128, Two Metal Plugs With two 1222 plugs: metal housings, spring grip electrical contacts and cable protectors. Contacts float for best alignment and connection. Cable clamps hold all size cables firmly in place. Cable protectors (where present) are constructed from plated steel, and provide strain relief and protection against abrasion. 11127-05, Two Metal Plugs With two 12092 plugs: metal housings, quick-release plug interiors and cable protectors. Rapid ship item. 4 BP Available in retail clamshell pack. 1232, 4-Pole, Protective Housing With special housing that protects terminals from roadsplash. 1236, 6-Pole Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com vehicle connectors 1254, 6-Pole, Cable Protector Same as 1236, but with cable protector. A 11042-05, Plug For use with 2-pole socket 11041-06. Durable, flexible spring coil protects the cable. 1233, 4-Pole Photo: Roll*Rite LLC. tarping apps O R BS EF O ER LE T EN E C FO E R O N LY 1253, 4-Pole, Cable Protector Same as 1233, but with cable protector. The two-pole power take-off is perfect for tarping applications ... but it's also used in liftgate connections and to supply power to a broad range of auxiliary equipment that's part of the truck or utility vehicle. It also finds use in powering on-site equipment. Cable See page 10. Interiors See page 6. 2-Pole Power Take-Off Connector Suitable replacement for connectors in tarping applications. Provides a high-integrity two-circuit path for on- and off-road vehicles and in agricultural applications. Plug latches solidly with the socket cover. Vertically-aligned machined brass contacts, diecast zinc plug and socket housings, engineering-grade plastic. Terminations accept 6AWG wire. Polarized. 11041-06, Socket Gasket-sealed socket keeps out dirt and moisture when plug is not in use. 1-Pole Power Take-Off Connector Provides power to auxiliary equipment. Accepts up to 0AWG cable. Diecast metal housings. Electrical conductors and connections are designed for maximum efficiency and long life. 11041, Socket Self-grounding. Solid brass 3/8" (9.5mm) diameter male contact, with insulated tip to prevent short circuits. Rubber boot protects the terminals and connections from moisture and dirt. Fits 2" (50.8mm) diameter hole. Two mounting holes on the flange 21/64" (8.6mm) diameter, 2 5/16" (74.6mm) on centers. 11042, Plug With ground return terminal. Brass female contact with spring grip tension provides solid engagement with the mating socket. Cable clamp holds cable firmly in place. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 5 vehicle connectors A External Ground/ Universal Line Connector 7-Pole Accept up to 8AWG and 10AWG wire. Spring-grip contacts have selfadjusting spring bands that ensure uniform contact with socket pins. Contacts float for best alignment and connection. Bumper construction protects the end of the plug housing. Provides an external ground where grounding cannot be obtained through the vehicle frame. Can be used in conjunction with 11041 and other primary electrical take-off units. 12312 Plug Interior, Spring-Grip Contacts For 12311 plug. O-ring seal. 1286, Plug Interior For 1222 and 1255 plugs. O R BS EF O ER LE T EN E C FO E R O N LY 11157, Socket Brass contacts and terminals. Accepts up to 6AWG cable. Corrosion-resistant plated steel housing. Stainless steel spring on the cover locks the plug in place, closes securely to protect the contacts. Rubber boot protects terminals and cable connection. Integral mounting bracket has two .218" (5.6mm) diameter mounting holes, 1.25" (31.8mm) on centers. 6-Pole 11156, Plug Plated brass housing. Threaded cable grip prevents loosening of cable. Accept up to 12AWG wire. 1296, Plug Interior For 1236 and 1254 plugs. 1158, Plug Interior Straight Body For 1236 and 1254 plugs, and many other makes of plug. A3 socket and plug interiors Impact-resistant insulators repel oil and water. Permanent molded-in wire codes provide easy identification. Contacts and connections are carefully designed to ensure maximum electrical efficiency. Terminal screws, socket mounting or plug mounting screws are provided. 13-Pole 1159, Socket Interior For 1235 socket. Split contact pins. Accepts up to 8AWG and 10AWG wire. 12302, Plug Interior For 12301 plug. Glass-filled plastic insulator, spring-grip brass contacts. O-ring seal. 4-Pole Accept up to 12AWG wire. 1295*, Plug Interior For 1253 and 1233 plugs. colors of wiring 1156*, Socket Interior For 1232 socket. Split contact pins. See page 98. Rapid ship item. 6 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com vehicle connectors A4 Automotive trailer connectors A 12501, Plug See also on page 4: `1- to 6-pole Connectors'. In-line Trailer Connectors Flat profile design provides a robust 7-pole or 12-pole connection. Housings are molded thermoplastic material, resistant to ultraviolet solar radiation. Nickel-plated brass terminals with split contact pins give a positive connection. Insulators between each terminal provide protection from short circuits. Spring-loaded socket lid protects the terminals when not in use. Insulated cable clamp secures the cable, minimizing vibration and strain. Terminal covers are easily removed for access to terminals. 8. 9. 10. 11. 12. Accessory Accessory Ground Accessory Accessory Weatherproof connectors & wire lead assemblies. Polarized to assure proper mating of circuits. Molded bodies. Color-coded 16AWG wire, 6" long (152.4mm). Conductors are properly aligned and bonded into the insulation, to assure minimal voltage drop, and for ease in connecting. 11135, 5-Pole Pair O R BS EF O ER LE T EN E C FO E R O N LY Circuit Identification: 1. Left turn signal 2. Accessory 3. Ground 4. Right turn signal 5. Accessory 6. Brake lights 7. Rear, clearance and side marker lamps Universal Trailer Connectors 7-pole connectors have circuits 1-7 only. 7-Pole 11134, 4-Pole Pair Connectors accept up to 14AWG wire. 12400, Socket 12401, Plug 11134-08BP, 4-Pole Pair, with Splicers Retail pack with 11134 and eight 30223 Quick-Tap wire splicers. 11173, 3-Pole Pair 12-Pole Pins 1 - 7 accept up to 14AWG wire, pins 8 - 12 accept up to 8AWG wire. 12500, Socket Accepts 12-pole plug or 7-pole plug. 11172, 2-Pole Pair Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 7 vehicle connectors A Connectors with Screw-On Caps Molded insulator bodies. Precision-machined contacts. Knurled caps unscrew for easy connection of wires, and protect against weather and dirt. Terminal ID .110" (2.8mm) accepts up to 12AWG stranded wire. 1238, 2-Pole Polarized Plug and Socket Screw-on cap protects the socket from dirt and moisture when not in use. Polarized for proper mating of circuits. Includes one 1102-F plug. Mount in 45/64" (17.9mm) diameter hole in panels up to 3/8" (9.5mm) thick. Plated steel cap and housing. 1107-F*, 2-Pole Female Plug 1292*, 2-Pole Socket with Variable Spacer Mounting nut, lockwasher and spacer are adjustable for different panel thicknesses. Mounts flush in 11/16" (17.5mm) diameter hole. Polarized for proper mating of circuits. Mates with 1102-F plug (not supplied). O R BS EF O ER LE T EN E C FO E R O N LY 1107-M*, 2-Pole Male Plug 1107*, 2-Pole Pair One 1107-M (male) and one 1107-F (female). Connectors with Rubber Caps Polarized to assure proper mating of circuits. Molded insulator bodies. Precision-machined brass contacts. Rubber caps protect connectors. 1134, 4-Pole Pair BP Circuit identification printed on the insulator. 1102*, 2-Pole Pair, Polarized Same as 1107, except polarized. M-118, 2-Pole Pair, Polarized, Brass Screws BP Same as 1107, except polarized, and with brass terminal screws. M-115, 4-Pole Pair, Brass Screws BP Same as 1134, but with brass terminal screws. 1102-F, 2-Pole Pair, Polarized Female polarized plug. M-114, 3-Pole Pair, Brass Screws Brass terminal screws. Rapid ship item. 8 BP Available in retail clamshell pack. BP Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com vehicle connectors M-121 2-Pole Pair, Brass Screws Brass terminal screws. BP Flush-Mount Flanged Socket Connectors A A5 farm equipment connectors Two-pole breakaway unit: plug automatically releases at approximately 20lbs pull. Mate with all connectors of comparable design. Polarized. 20A maximum capacity. 1282, Socket with Mounting Bracket Plated steel housing. High impact-resistant molded plastic insulator. Brass contacts and brass screw terminals. Stainless steel spring on the cover locks the plug in place. Integral mounting bracket with two .218" (5.6mm) diameter mounting holes, 1.25" (31.8mm) on centers. Corrosion-resistant socket housings. Two .147" (3.73mm) diameter mounting holes, 1/19" (30.23mm) on centers. O R BS EF O ER LE T EN E C FO E R O N LY 1110*, 2-Pole Male Socket Mates with 1107-F plug. 1109*, 2-Pole Female Socket Mates with 1107-M plug. 1283-325*, Plug Plated brass housing. Threaded cable grip. 1145*, 2-Pole Male Socket, with Cover Mates with 1102-F plug. Pivot cover protects against moisture and dust. Polarized. 1214, 2-Pole Male Socket, with Cover and Plug 1102-F plug and 1145 socket. Polarized. ag. app. Several of the `tractor trailer' plugs are also useful in agricultural applications. Two of the most popular are the 7-pole connectors 12080/12081/12082 and 12310/12311 as well as the 13-pole connectors 12300/12301. See page 1. trailer tail light converter Electronic unit permits a towing vehicle with two lighting circuits for each side to operate lights on a trailer with a single circuit each side. Eliminates the need to rewire the trailer or to add additional lights. US laws require stoplights, turn signals and tail lights on trailers. See Page 64. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 9 A vehicle connectors Trailer Connector Adapters A6 accessories Straight cable, available by the foot. Conductor wires are color-coded for easy recognition. Durable insulation resists abrasion. These adapter assemblies are useful to conveniently connect a 6-pole system to a 7-pole system, and eliminate makeshift jumpers. Connect the appropriate adapter to your existing cable assembly to link a vehicle with a 6-pole male socket to a vehicle with a 7-pole male socket. Brass pins, brass female contacts. 98647, 13-Conductor Will not crack or stiffen at -70F (-57C). One 8AWG, one 10AWG, five 12AWG and six 14AWG wires, 100% electrical copper for maximum conductivity. 11011, For Use with a 7-Pole Cable Assembly Consists of a 6-pole female diecast plug connected by a 12" cable to a 7-pole male plug. The 7-pole plug is plastic with a plastic boot. Cable 12AWG BLUE 8AWG WHITE 14AWG WHITE/GREEN 12AWG BROWN 14AWG WHITE/ORANGE 12AWG GREEN 14AWG WHITE/BLACK 11017, For Use with a 6-Pole Cable Assembly Consists of a 6-pole male plastic plug connected by a 12" cable to a 7-pole female diecast plug. 14AWG WHITE/YELLOW 12AWG BLACK 14AWG WHITE/BLUE 12AWG YELLOW 14AWG WHITE/RED 10AWG RED O R BS EF O ER LE T EN E C FO E R O N LY 4077, 7-Conductor Six 12AWG wires and one 10AWG white wire. BLUE 10AWG WHITE BROWN BLACK GREEN YELLOW RED Protective Boots Protect against road splash, dirt and moisture. 4076, 6-Conductor Six 14AWG wires. 81356, Boot for 12300 and 12310 Sockets Fits over the back of the flange, and covers the terminal connectors. Protects against road splash, dirt and moisture. For 12310 7-pole socket and 12300 13-pole socket. RED WHITE BROWN BLACK YELLOW GREEN 4075, 4-Conductor Four 14AWG wires. WHITE RED BLACK BROWN 11178, Boot for 7-Pole Sockets Inner ridge locks over the heads of the terminal screws and to the edge of the casting. Fore Cole Hersee sockets 12063, 12063-01, 12080, 12080-01, 12080-11, 12077-01 and other 7-pole sockets of comparable design. Cable Protector 81192, Cable Protector Protects against strain and kinking. Plated steel. For Cole Hersee plugs: 11042-05, 12081, 12082, 12091, 12092. Rapid ship item. 10 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com vehicle connectors Surface Mounting of Sockets For attachment of 4-, 6-, and 7-pole sockets of standard design (without integral circuit breakers). 11167, Adapter Plate Heavy duty adapter provides secure seating for attachment of sockets, and permits installation of fuse/breaker block or terminal block in the rear. Mounting holes 5/16" (7.9mm) diameter, 4 1/2" (114.3mm) on center. Mounting hardware included. A 11750, Stor-A-Way Plug Holder Cole Hersee patent. Keeps plugs clean when not in use, and extends life, by protecting electrical contacts from dirt and roadsplash. For all SAE J560b 7-pole plugs and 13-pole plugs. Spring-loaded for secure locking. Heavy duty glass-filled plastic housing. Fits 11100-02, 12311, 1222, 1255, 12091, 12092, 12081, 12082, 12301, 11042 and 11042-05. 11751 Plug Holder fits 1236 and 1254 and all similar six pole plugs. O R BS EF O ER LE T EN E C FO E R O N LY 11165, Mounting Bracket Eliminates the need for cutting a hole in the trailer to accept a socket. Mounting hardware included. Center hole is 2" (50.8mm) diameter. Mounting hardware included. 31784, Female Pin Terminal Crimp-on brass connector mates with the 6 smaller pins in the 12301 13-pole plug and 12300 13-pole socket. Pre-tinned brass. 6 required for each 13-pole plug. 11164, Mounting Gasket for Sockets Neoprene gasket for plastic or metal sockets. For Cole Hersee sockets 12063, 12063-01, 12080, 12080-01. 11187, Plug Cleaner Brush For 7-pole plugs. Durable plastic body with snap-on cover. Stainless steel wire will not rust. Brush cleans corroded contacts in seconds, and with regular use extends the life of connectors 1160, License Holder Tube Weatherproof tube protects important papers. 5" x 1 1/8" (127.0 x 28.6mm). Captive brass screw-on cap. Brass flange, aluminum body. Three 3/16" (4.8mm) diameter mounting holes in the flange. assembly of plugs See page 98 for the best way to assemble plugs and sockets. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 11 ignition & key switches B B1 956 series ignition and starter switches Off Acc All ignition switches in this series with blade terminals accept Delphi (Packard) connector 2962912. Ign/Acc Ign/Start Heavy Duty Spring return to IGN/ACC. Key is removable only in the Off position. Dependable switches with an array of options for every application. Electrical ratings at 12V DC: 10A Accessory, 10A Ignition, 5A Start, 1A Ground 3-Position Off - Ignition - Ignition/Start Patented Hencollock and two keys. With short handle Hencol key "Hencol S". Actuation/ Part No. Terminals Lock Seal 956-5307 3 screw Hencol S G O Ground Terminal - O R BS EF O ER LE T EN E C FO E R O N LY Coded tumbler lock and two keys. Bushing 3/4"-24 Off Ign With short handle lever knob "Lever S". Letter Code in tables in this section: Hencol S = Hencol keys 83357 Lever S = Short handle lever knob 81254 S = Shutter lock seal G = Gasket seal O = O-Ring seal in stem Ign/Start Spring return to IGN. Key is removable only in the Off position. Electrical ratings at 12V DC: 10A Ignition, 5A Start, 1A Ground Terminals: Brass blade, 1/4" (6.4mm) wide, which accept Delphi (Packard) connector 2962912 or equivalent, or screw terminals with lock washers. Sealed terminal insulator. Housing: Corrosion-resistant diecast construction. Off - Ignition/Accessory - Ignition/Start Actuation/ Part No. Terminals Lock Seal 956-5109 4 screw Lever G Actuation/ Part No. Terminals Lock Seal 956-4100 4 blade Coded S 956-4104 4 screw Coded S 956-4107 4 screw Hencol S G O 956-4111 4 blade Lever S - 956-4124 4 screw Lever S G O 956-4154 5 screw Coded S 956-4304 4 screw Coded - 956-4307 4 screw Hencol S G O 956-4311 4 blade Coded O 956-4704 4 screw Coded S Ground Terminal - - - - - - - - - 956-4148 With identical key code CH-528 4 blade Coded S Rapid ship item. BP 12 Available in retail clamshell pack. Bushing 1"-24 Off Ign/Acc Mounting: 1"-24 bushings fit panels from .030" (.76mm) through .090" (2.3mm) thick. All other bushing sizes fit panels .060" (1.5mm) up to .110" (2.7mm) thick. 4-Position Ground Terminal - Ign/Start With military lever, Spring contacts, Spring return to IGN/ACC. Key is removable only in the Off position. Electrical ratings at 12V DC: 956-5109: 20A Accessory, 10A Ignition, 10A Start Bushing 1"-24 1"-24 1"-24 1"-24 1"-24 1"-24 3/4"-24 3/4"-24 3/4"-24 7/8"-24 Accessory - Off - Ignition/Accessory Actuation/ Part No. Terminals Lock Seal 956-6104 3 screw Coded S Ground Terminal - Bushing 1"-24 Off Acc Ign/Acc Key is removable only in the Off position. Electrical ratings at 12V DC: 10A Accessory, 10A Ignition 1"-24 Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com ignition & key switches 2-Position Actuation/ Part No. Terminals Lock Seal 956-7304* 2 screw Coded S Ground Terminal - Bushing 3/4"-24 B Extra Heavy Duty Ignition and Starter Switches Specially designed for demanding applications with higher energy circuits, typically 30A or 20A at 12V DC. Off 4-Position On (Ign) Accessory - Off - Ignition/Accessory - Ignition/Start Key is removable only in the Off position. Electrical ratings at 12V DC: 10A Ignition Actuation/ Part No. Terminals Lock Seal 956-4113 4 blade Hencol S S O 956-4116* 4 blade Coded S G Coded - 956-4138 4 blade Anti-Restart Ignition Switches Bushing 1"-24 1"-24 1"-24 Off Acc Ign/Acc O R BS EF O ER LE T EN E C FO E R O N LY When the engine is running, the starter circuit cannot be energized. This prevents accidental damage to the starter motor, and is highly recommended in situations such as package delivery vehicles or in noisy locations where it might not be evident that the motor is running. The switch must be turned to the Off position before the start circuit an be re-energized. Ground Terminal - - - Part No. Terminals 956-3124 5 screw 956-3125 4 screw 956-3126 4 screw 956-3134u 4 screw 956-3137* 4 screw Actuation/ Lock Seal Lever S O Coded G S Hencol S G Coded G S Hencol S G O Ground Terminal 3 - - - - Bushing 1"-24 1"-24 1"-24 1"-24 1"-24 With identical key code CH-535 956-3130* 4 screw Coded G S - 1"-24 u Same as No. 3125 except with accessory terminal rotated 180. Ign/Start Key is removable only in the Off position. Spring return to IGN/ACC. Electrical ratings at 12V DC: 30A Accessory, 10A Ignition, 5A Start: switches 956-4113, 956-4125. 30A Accessory, 10A Ignition, 10A Start: switch 956-4116. 20A Accessory, 20A Ignition, 10A Start: switch 956-4138. Off Ign/Acc Ign/Start Spring return to IGN/ACC. Key is removable only in the Off position. anti-restart Electrical ratings at 12V DC: 10A Accessory, 10A Ignition, 5A Start, 1A Ground: switches 956-3124, 956-3126. 30A Accessory, 10A Ignition, 10A Start: switches 956-3125, 956-3134. No more burned out starter motors! Use Anti-Restart Ignition Switches in situations where equipment is frequently left idling, and there is chance that the operator might `restart' the engine. This occurs in industrial locations where noise levels are high, in delivery trucks, and many other situations. 10A Accessory, 10A Ignition, 5A Start: 956-3137. LVD New electronic Low Voltage Disconnect Switch automatically disconnects accessory circuits to maintain starting power, then reconnects them when battery is recharged. See page 39. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 13 b ignition & key switches B2 Universal ignition and starter switches 4-Position Accessory - Off - Ignition/Accessory - Ignition/Start Case A Actuation/ Part No. Terminals Lock Coded 9579 BP 4 screw 95535 4 screw Coded 95515-A 4 screw Hencol S 95525-A 4 screw Hencol S Zinc diecast, coded tumbler lock. Fits panels up to 3/8" (9.5mm). Case B Off Acc Case A B C C 3/4"-20 Key is removable only in the Off position. Spring return to IGN/ACC. Electrical ratings at 12V DC: 10A Accessory, 10A Ignition, 5A Start. Ign/Acc Ign/Start O R BS EF O ER LE T EN E C FO E R O N LY Case C Plated steel. Non-tumbler Hencol lock: either short handle key (Hencol S), or long handle key (Hencol L). Fits panels up to 1/8" (3.2mm). Bushing 3/4"-20 13/16"-24 5/8"-32 5/8"-32 With identical key code CH-505 4 screw Coded - A 9579-02 Plated steel, coded tumbler lock. Fits panels up to 1/2" (12.7mm). Seal - - - O 3-Position off - Ignition - ignition/start Heavy Duty Ratings at 12V DC: 10A Ignition, 5A Start. In the tables: Actuation/Lock column: Hencol S = Hencol key 83357, Hencol L = long handle Hencol key 83353; Lever S = short lever knob 81254, Lever L = long lever knob 80101 -B. Seal column: S = Shutter lock seal, G = Gasket seal, O = O-ring seal in stem. Actuation/ Part No. Terminals Lock 9513 3 screw Coded 95534 3 screw Coded 95514-A 3 screw Hencol S Hencol S 95524-A 3 screw 95582 3 screw Coded Seal - - - O Case A B C C Bushing 3/4"-20 13/16"-24 5/8"-32 5/8"-32 O A 3/4"-20 Zinc diecast, military lever. Fits panels up to 11/64" (4.4mm). Extra Heavy Duty Ratings at 12V DC: 25A Ignition,20A Start: 95610, 95612 25A Ignition, 70A Start: 95521-B. Case F Actuation/ Part No. Terminals Lock 95610 3 screw Lever S 3 screw Lever S 95612 95521-B 3 screw Hencol L Case D Plated steel. Lever knob: either short (Lever S), or long (Lever L). See page 18. Fits panels up to 1/8" (3.2mm). Seal - O O Case F F G Bushing 5/8"-32 5/8"-32 5/8"-32 Off Ign Ign/Start Key is removable only in the Off position, spring return to IGN. Case G Plated steel. Non-tumbler Hencol lock: either short handle key (Hencol S), or long handle key (Hencol L). Fits panels up to 1/4" (6.4mm). Rapid ship item. 14 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com ignition & key switches b Magneto Ignition and Battery Start Switches 2-Position Off - On (Ignition) Actuation/ Part No. Terminals Lock 2 screw Coded 9577 95532 2 screw Coded 95512-A 2 screw Hencol S 95522-A 2 screw Hencol S Seal - - - O Case A B C C Bushing 3/4"-20 13/16"-24 5/8"-32 5/8"-32 Dependable switches suitable for golf and utility carts, lawn and garden tractors and similar applications. Off - Run - Start (Start Terminal to Battery) Key is removable only in the Off position, except 9518 where the key is removable in both positions. Off - Mag terminal to ground Run - Mag & S terminal open Off Start - Mag terminal open, S terminal to battery On (Ign) 95520-B, 70A Start Electrical ratings at 12V DC: 70A Start, 1A Magneto. Three screw terminals. Plated steel case. 5/8" -32 mounting stem with O-ring seal, fits panels up to 1/4" (6.4mm). Long Hencol key. O R BS EF O ER LE T EN E C FO E R O N LY Electrical ratings at 12V DC: 10A Ignition Key removable in Off position, spring return to RUN. Self-grounding in the Off position in metal panels. b3 specialized ignition switches Marine Design Switches Durable plastic case and stem with PVC boot for added weather protection. Key is removable only in the Off position. Off-Run-Start Spring return to IGN. Electrical ratings at 6-36V DC: 15A ignition, 5A start. M-850 BP Three nickel-silver screw terminals. Mounting stem fits panels up to 7/8" (22.2mm) thick, with 7/8" diameter hole. Off - Run/Accessories - Start Off - Mag terminal to ground Run/Acc - Mag & G terminal open, Acc/Bat terminal closed M-832, Long Stem with Push-To-Choke BP Six nickel-silver screw terminals. Long mounting stem 2.00" (50.8mm) long, fits panels up to 1 3/8" (34.9mm) thick, and with 7/8" diameter hole (22.2mm) Start - Mag & Acc terminal open, Acc/Bat terminal closed Key removable in Off position, spring return to RUN/ACC. Self-grounding in the Off position in metal panels. Electrical ratings at 12V DC: 10A Accessory, 5A Start, 1A Magneto. 95539 Four screw terminals. Diecast case. 3/4"-20 mounting stem, fits panels up to 1/2" (12.7mm). Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 15 ignition & key switches b Reversing Switch Delco Replacement Ignition and Start Switches Off Off On Reverse On Forward Acc Key removable at Off, spring return to IGN/ACC Mom Forward - Off - Mom Reverse Key removable in Off position, spring return to Off. Ign/Acc Ign/Start 95400 Four screw terminals. 75705-01, 10A with Tumbler Lock Electrical Ratings at 12V DC: 10A. Three screw terminals. Plated steel case. 13/16"-24 mounting stem with O-ring seal. Replaces: Delco D-1460, GMC 116508, Motorcraft SW-276. Off Ign/Acc Ign/Start/Ground O R BS EF O ER LE T EN E C FO E R O N LY Key removable at Off, spring return to IGN/ACC Acc 95408, 5-Blade Terminals, for Delphi (Packard) 2984170 Without lock cylinder (order 95874, cylinder, 2 keys). Five blade terminals. 1"-24 UNS-2A thread. Replaces: Delco D-1469, D-1482, D-1482-A, GMC 1116672, 74, 85, 87, 1116704, 10. GMC Trucks '70. reversing switches 95410, 7-Blade Terminals, for Delphi (Packard) 6288702 Without lock cylinder (order 95874, cylinder, 2 keys). Seven blade terminals, includes two ground terminals for checking indicator bulbs. One additional battery terminal provides continuous hot feed for optional equipment. O-ring seal in the mounting stem. 1"-24 UNS-2A thread. Reversing Switches This type of switch has multiple applications: on cranes, hoists, winches, snowplows etc. -- anything that calls for a motor to operate in forward-reverse, translating to motorized motion of updown, left-right, open-close, in-out etc. An alternate mechanism is to use Reversing Solenoids 24400, 24401, 24401-01, 24402, 24450 in conjunction with rocker, toggle, push-pull or rotary switches. These solenoids are also used for forward-reverse in simple automotive vehicles, such as golf carts and garden tractors. Replaces: Delco D-1403-A, D-1406-A, D-1480, D-1498-A, GMC 1116712, 1116683, 95, 1116704, 09, 11, 2234285, Chevrolet Trucks 67-83, 85-89, GMC Trucks 67-83, 85-89. Compact Ignition and Start Switch Off On (Ign) Battery Ignition and Light Switch 9621-01 Provides a light circuit in addition to the ignition function. Electrical Ratings at 12V DC: 5A Ignition, 5A Lights. Three screw terminals. Plated steel case. 5/8"-32 mounting stem, fits panels up to 9/64" (3.6mm). Key removable at Off only 9500, 10A with Lever Electrical Ratings at 12V DC: 10A Two screw terminals. Plated steel case. 1/2"-20 mounting stem fits panels to 13/64" (5.2mm). Rapid ship item. 16 BP Available in retail clamshell pack. Off Ign Ign/Lights Lights Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com ignition & key switches Push-Pull Battery Ignition and Starter Switch 9576 Spring return to IGN/ACC.Electrical Ratings at 12V DC: 10A Accessory, 5A Ignition, 5A Start. Four screw terminals. Plated steel case. 3/8"-24 mounting stem fit panels up to 3/16" (4.8mm). Includes hexnut and washer b 9183, Short Plunger Same as 9060, but with 1" (25.4) long plunger. Replaces: Autolite SW-4012 (15-49), Delco 1996478. B4 95060 series sealed key switches Ign/Acc Ign/Start O R BS EF O ER LE T EN E C FO E R O N LY Off With integral sealed Deutsch connector. Rugged plastic construction, with fully sealed contact area, using O-rings and ultrasonic welding. Contacts sealed front and back to IP67 (with connector installed). Available with or without key boot, with or without anti-restart, with or without spring return to Ignition/Accessory position. Key is removable only at the Off position. Tested to SAE J259 for ignition switches. Supplied with two matching tumbler keys. Contact rating 10A at 12V DC, 5A at 24V DC. Ignition Switch with Wire Lead Assembly Off On (Ign) 95614 Key removable in Off. Electrical Ratings at 12V DC: 5A. Two 12" 14AWG wire leads with attached ring terminals. Heavy duty steel case, plated to resist corrosion. Coded lock cylinder with two keys. Rubber boot seal for added moisture and dust protection. 13/16" (20.6mm) diameter mounting stem, 25/64" (9.9mm) long fits panels up to 7/32" (5.5mm). Part No. 95060 95060-01 95060-02 95060-03 95060-04 95060-05 95060-06 95060-07 Foot-Operated Starter Switches Positions 4: Acc-Off-Ign/Acc-Start 4: Acc-Off-Ign/Acc-Start 4: Acc-Off-Ign/Acc-Start 3: Off-Ign/Acc-Start 3: Off-Ign/Acc-Start 3: Off-Ign/Acc-Start 3: Acc-Off-Ign/Acc 2: Off-Ign/Acc Spring Return 3 3 - 3 3 - - - Key Boot Anti-restart 3 3 3 3 3 3 3 3 3 3 - * Other circuitries are available consult Cole Hersee. Off-On, normally Off. On with plunger depressed, spring return to Off. Copper contacts and terminal studs. 9060, Long Plunger 1.83" (46.5mm) long plunger. Two stud terminals, 5/16"-24 thread with hexnuts and lockwashers. Mounting: two 9/32" (7.2mm) diameter holes, 1 3/4" (44.5mm) on centers. Replaces: Autolite SW-40001 (15-47), 15-50, 4001A, 4002, 4005, 4010, 4015 (15-51), Delco D900 (405C). Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 17 b ignition & key switches Keys for Cole Hersee Ignition Switches b5 accessories Protective Boots Hencol keys Mounting nut containing a durable rubber with a self-closing key slot. Patented Hencol lock and key system gives trouble-free performance. Heavy gauge steel, plated to resist corrosion. 83285-01, Aluminum 3/4"-20 thread, 7/16" (11.1mm) thickness. 83357, Short 95030-A 95512-A 95514-A 95515-A 95516-A 95517-A 83288, Chrome-Plated Brass 13/16"-24 thread, 17/32" (13.5mm) thickness. 95522-A 95523-A 95524-A 95525-A 95526-A 95527-A 95528-A 95561-01 95564-01 95616 95616-01 95617 95663-01 95663-04 956-9100 O R BS EF O ER LE T EN E C FO E R O N LY 83353, Long In tables on page 14, this key is denoted `Hencol L'. Long key is on these switches: Plastic Cap 95511-B 95521-B 95520-B 95597 97298 Captive black protective cap, used with facenut 83295-A Tumbler Lock Key Blanks 83406 For these Ignition Switches: Facenuts Part No. Thread 83296 1"-24 83346* 7/8"-24 83348 3/4"-24 8367 3/4"-20 83337 13/16"-24 83295-A 13/16"-24 8391-A 5/8"-32 83321-A* 1"-32 8391-C 5/8"-32 956-4119 9577 956-4125 M-702 Hole to Clear 21/32" 5/8" 5/8" 5/8" 5/8" 5/8" 1/2" 15/16" 3/4" Type Thickness Aluminum Round Knurl 13/32" Aluminum Round Knurl 3/8" Aluminum Round Knurl 3/8" Aluminum Round Knurl 19/64" Brass-Chrome Plate-Hex 15/64" Brass-Chrome Plate-Hex 15/32" Brass-Zinc Plate-Hex 1/4" Zinc Die Cast Round 5/16" Brass-Chrome Plate 1/4" 9518 83373 For these Ignition Switches: 956-3122 956-3125 956-3131 956-3134 956-4100 956-4104 956-4148 956-4116 956-4154 956-4304 956-4305 956-4311 956-4354 956-4704 956-5108 956-5122 956-5144 956-5304 956-5344 956-6104 956-6304 956-7104 956-7304 95582 95583 83379 For these Ignition Switches: 9513 9578 9579 9622-01 75705-01 95532 95534 9579-02 Color-Coded Key Covers Covers slip over Cole Hersee tumbler lock keys 83406, 83373 and 83379, and make key identification easy. 95535 95537 95539 95593 95608 90005-03 95614 M-489 M-550-04 M-701 M-550-14 M-703 M-550-25 M-711 M-712 M-932 M-712-09 M-95502 M-712-10 M-95602 M-700 M-924 M-550 98635-01, Black 98635-03, Red Rapid ship item. 18 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com rocker & toggle switches c1 weather-resistant rocker switches Switches for universal applications. Contact area sealed against dirt and moisture entry to IP66. Snap-in mounting fits standard hole .830" x 1.45" (21.1 x 36.8mm). Fits panels from .093" to .187" thick (2.4 x 4.7mm). For bezels to hold these switches together side by side, see page 25. Circuit diagrams: see page 91. 58328 Series with Pilot Lights, 25A Single or dual pilot lights, dependent or independent illumination. Faceted lenses are on the actuator. Matte finish black plastic housing, bezel and actuator. Silver contacts, brass blade terminals. 25A at 12V DC. Two Pilot Lights Lens colors are listed top lens/bottom lens. On-On SPDT, two dependent Four blade terminals. Diagram J, page 93. 58328-08, Green/Green 58328-14, Amber/Amber 58328-15, Clear/Clear 58328-16, Red/Red 58328-17, Amber/Clear 58328-18, Amber/Green 58328-19, Amber/Red O R BS EF O ER LE T EN E C FO E R O N LY Each of the five electrical configurations of switch is also available as a BP (bubble pack) retail unit, containing separate lenses of all colors. Lenses snap easily into place. C 58328-20, Clear/Green One Pilot Light 58328-21, Clear/Red Off-On SPST, dependent 58328-22, Green/Red Three blade terminals. Diagram F, page 93. 58328-102BP Kit BP With two lenses of each color. BP only. 58328-04, Red Lens 58328-11, Green Lens 58328-12, Clear Lens 58328-13, Amber Lens 58328-100BP Kit BP With one lens of each color. BP only. dependent or independent? Dependent Illumination When the switch is On, the handle is illuminated. Off-On SPST, independent Four blade terminals. Diagram G, page 93. 58328-01, Red Lens 58328-02, Green Lens Independent Illumination Actuation of the switch does not affect the illumination of the handle. The switch can be On or Off, and illumination is usually controlled by another switch. This mode can be used to light a whole bank of switches, and is especially useful for locating switches in the dark. 58328-09, Clear Lens 58328-10, Amber Lens 58328-101BP Kit BP With one lens of each color. BP only. wiring diagrams See page 93. identify that switch... A quick visual inspection will often tell you. See page 97. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 19 c rocker & toggle switches With Pilot Light(s) On-Off SPST, dependent and independent Four blade terminals. Diagram H, page 93. 58328-05, Red/Clear SPST 58328-39, Green/Green Diagram F, page 93. 58328-40, Red/Red 56327-01, Off-On BP One red pilot light. Three screw terminals. 58328-47, Green/Amber 58328-48, Green/Clear 58327-01, Off-On BP One red pilot light. Three blade terminals. 58328-49, Green/Red 58328-50, Red/Amber 58328-51, Red/Green 58328-104BP Kit BP With one lens of each color and size. BP only. SPDT Diagram J, page 93. O R BS EF O ER LE T EN E C FO E R O N LY 58327-06, On-Off-On BP Two red pilots. Four blade terminals. On-Off-on SPDT, two dependent Four blade terminals. Diagram J, page 93. 58328-06, Red/Clear 58328-07, Green/Clear Without Pilot Lights 58328-25, Green/Green SPST 58328-26, Red/Red Diagram A, page 93. 58328-33, Green/Amber 56027-01, On-Off BP Two screw terminals. 58328-34, Green/Red 58328-35, Red/Amber 58328-36, Red/Green 58027-01, On-Off BP Two blade terminals. 58328-103BP Kit BP With one lens of each color and size. BP only. 58027-02, Off-Mom On Two blade terminals. With and Without Pilot Lights, 25A SPDT BP Diagram B, page 93. Unlit, single or dual dependent pilot lights. Matte black plastic housing, bezel and actuator. Silver contacts. 56 Series has brass screw terminals. 58 Series has brass blade terminals. 25A at 12V DC. Other screw terminal switches in this series are available - contact Cole Hersee. 58027-03, On-Off-On Three blade terminals. BP 58027-04, Mom On-Off-Mom On Three blade terminals. BP DPST 58027-06, Off-On Four blade terminals. Diagram C, page 93. Rapid ship item. 20 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com rocker & toggle switches c 58326 Series with Pilot Lights, 20A DPDT 58027-07, On-Off-On BP Six blade terminals. Diagram E, page 93. 58027-11, Mom On-Off-Mom On BP Six blade terminals. Diagram E, page 93. 58027-18, Mom On-Off- Mom On; Forward-Reverse Four blade terminals. Single or dual pilot lights. Faceted lenses inset into the actuator. Matte black plastic housing, bezel and actuator. Silver contacts, up to eight brass blade terminals, of which terminals 7 & 8 connect the pilot light(s). Internal seal. Many other imprinted switches are available in this series. 20A at 12V DC. All are specified for Thomas Built (R) school buses except 58326-01. L B _ 1 4 2 5 + B Forward-Reverse switch O R BS EF O ER LE T EN E C FO E R O N LY 58326-01, SPST Off-On Red LED Lens Off-On 5&6. Not imprinted. Independent illumination. Consult Cole Hersee for other styles. Diagram L, page 94. M-58031 Series, 20A Certified to IP66 for protection against dust and prolonged spray. Recognized at UL 1500: Ignition Protection for Marine Products. With neoprene gasket/panel seal. 20A at 12V DC. Blade terminals, silver contacts, black nylon bezel, black plastic housing. M-58031-01, SPST Off-On BP Two blade terminals. Diagram Q, page 94. M-58031-02, SPDT On-Off-On BP Three blade terminals. Diagram R, page 94. M-58031-04, DPST Off-On BP Four blade terminals. Diagram T, page 94. M-58031-06, DPDT On-On Six blade terminals. Diagram P, page 94. M-58031-07, SPST Off- Mom On BP Two blade terminals. Diagram Q, page 94. 58326-11, Warning Lights Switch, Off-On-Mom On DP Off-On 2&3-Mom On 2&3 and 5&6. Imprinted `Amber. Warning (On). Off' with SAE warning lamp symbol imprinted on the white lens. Independent illumination. Diagram M, page 94. 58326-12, Left Heater Fan Switch, On-Off-On DPDT On 1&2, 4&5 - Off-On 2&3, 5&6. Imprinted `High. Left Heater. Low' with SAE fan symbol imprinted on the white lens. Independent illumination. Diagram O, page 94. 58326-21, Windshield Washer Switch, Off-Mom On SPST Off-Mom On 2&3. Imprinted `On. W/S Washer' with SAE washer symbol imprinted on the white lens. Independent illumination. Diagram N, page 94. 58326-24, Windshield Defrost Switch, On-On-On DPDT On 1&2, 4&5 - On 2&3, 5&4 - On 2&3, 5&6. Imprinted `Lo/Hi. Def. Off' with SAE defroster symbol imprinted on the white lens. Independent illumination. Diagram O, page 94. 58326-25, Left Heater Switch, On-On-On DPDT On 1&2, 4&5 - On 2&3, 5&4 - On 2&3, 5&6. Imprinted `Lo/ Hi. Left Heater. Off' with SAE fan symbol imprinted on the white lens. Independent illumination. Diagram O, page 94. wiring See page 94 for wiring of M-58031 Series & 58326 Series. 58326-27, Passenger Heater Fan Switch, On-On-On DPDT On 1&2, 4&5 - On 2&3, 5&4 - On 2&3, 5&6. Imprinted `Lo/ Hi. Pass Heater. Off' with SAE fan symbol imprinted on the white lens. Independent illumination. Diagram O, page 94. 58326-29, Fan Switch, On-On-On DPDT On 1&2, 4&5 - On 2&3, 5&4 - On 2&3, 5&6. Imprinted `Lo/Hi. Fan. Off' with SAE fan symbol imprinted on the white lens. Independent illumination. Diagram O, page 94. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 21 rocker & toggle switches c c2 standard Rocker, plastic bezel c3 standard rocker, metal bezel 25A at 12V DC. Moisture-resistant plastic housings, bezels and actuators. Glossy finish actuators and bezels except where noted. Snap-in mounting to fit panels .060" through .250" (1.5mm to 6.4mm). Silver contacts, brass blade or screw terminals. White actuators except where otherwise indicated. Fits standard panel hole .83" x 1.45" (21.1 x 36.8mm). Single and Double Pole. Universal application. Bright nickel plate or black bezel, narrow or wide. Plastic housing and actuator. Snap-in to fit panels 040" through .100: (1.0 to 2.5mm). Screw or blade terminals. 25A at 12V DC. Circuit diagrams, see page 93. SPST 57000-23, On-Off Two blade terminals. 56001-04*, Mom On-Off Two screw terminals. Pilot light, bright bezel Black actuator, black bezel .12" (3.1mm) .23" (5.8mm) O R BS EF O ER LE T EN E C FO E R O N LY 57000-33, On-Off, Red Actuator Typically used for a safety switch. Two blade terminals. 1.57" (39.9mm) DPDT 1.75" (44.5mm) Narrow Bezel Wide Bezel .16" (4.1mm) 56006-04*, On-Off-On Six screw terminals. .90" (22.9mm) 57005-11, On-On Six blade terminals. .26" (6.6mm) 1.12" (28.4mm) SPST 57013-08, Mom On-Off-Mom On Six blade terminals. Narrow Bezel 56000-01, On-Off White actuator, bright bezel. Up: On, Down: Off, two screw terminals. locking switch 56001-01, Mom On -Off White actuator, bright bezel. Up: Mom On, Down: Off, two screw terminals. 58336 57000-01, On-Off White actuator, bright bezel. Up: On, Down: Off, two blade terminals. SPST On-Off. Bright orange lock automatically locks the actuator when in the Off position, and must be slid to allow the actuator to be moved to the On position. Matte black finish housing, bezel and actuator. Two blade terminals. 20A at 12V DC. 57000-04, On-Off Black actuator, black bezel, Up: On, Down: Off, two blade terminals. 57001-01, Mom On -Off White actuator, bright bezel. Up: Mom On, Down: Off, two blade terminals. SPST, DPDT...? See page 92 for an explanation. Rapid ship item. 22 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com rocker & toggle switches Wide Bezel 56000-02, On-Off White actuator, bright bezel. Up: On, Down: Off, two screw terminals. 57000-02, On-Off White actuator, bright bezel. Up: On, Down: Off, two blade terminals. SPST with Pilot Light c SPDT Narrow Bezel 56002-01, On-On White actuator, bright bezel. Up: On, Down: On, three screw terminals. 56003-01, On-Off-On White actuator, bright bezel. Up: On, Center: Off, Down: On, three screw terminals. 57002-01*, On-On White actuator, bright bezel. Up: On, Down: On, three blade terminals. O R BS EF O ER LE T EN E C FO E R O N LY 57003-01, On-Off-On White actuator, bright bezel. Up: On, Center: Off, Down: On, three blade terminals. Narrow Bezel 57007-01, On-On-Off White actuator, bright bezel. Up: On, Center: On, Down: Off, three blade terminals. 56300-01, On-Off White actuator, bright bezel. Red dependent pilot light. Up: On, Down: Off, three screw terminals. Diagram F, page 93. 57007-08, On-On-Off Black actuator, black bezel. Up: On, Center: On, Down: Off, three blade terminals. 56300-11, On-Off White actuator, bright bezel. Amber dependent pilot light. Up: On, Down: Off, three screw terminals. Diagram F, page 93. 57007-11, On-On-Off, Imprinted Black actuator, black bezel. Up: On, Center: On, Down: Off, three blade terminals. Imprinted "Off, Lo, High." 57300-01, On-Off White actuator, bright bezel. Red dependent pilot light. Up: On, Down: Off, three blade terminals. Diagram F, page 93. Wide Bezel 57300-03, On-Off Black actuator, bright bezel. Red dependent pilot light. Up: On, Down: Off, three blade terminals. Diagram F, page 93. 57003-02, On-Off-On White actuator, bright bezel. Up: On, Center: Off, Down: On, three blade terminals. Wide Bezel SPDT with Pilot Light 57300-02, On-Off White actuator, bright bezel. Red dependent pilot light. Up: On, Down: Off, three blade terminals. Diagram F, page 93. 57007-07, On-On-Off Black actuator, bright nickel narrow bezel. Red dependent pilot light. Up: On, Center: On, Down: Off, four screw terminals. 57300-10, On-Off Black actuator, bright bezel. Red dependent pilot light. Up: On, Down: Off, three blade terminals. Diagram F, page 93. B + L1 L2 identify that switch... A quick visual inspection will often tell you. See page 97. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 23 c rocker & toggle switches DPDT 58506-11, On-Off/On-Off Left switch: On-Off, imprinted "On, Off" Right switch: On-Off, imprinted "On, Off" Black actuators with white imprints. Four terminals. Narrow Bezel 56006-01, On-Off-On White actuator, bright bezel. Up: On, Center: Off, Down: On, six screw terminals. SPDT 58506-07, Hi-Off-Lo/Hi-Off-Lo 57006-01, On-Off-On White actuator, bright bezel. Up: On, Center: Off, Down: On, six blade terminals. Left switch: On-Off-On, imprinted "Hi, Off, Lo" Right switch: On-Off-On, imprinted "Hi, Off, Lo" Black actuators with white imprints. Six terminals. 58007-04, On-On-On Black actuator, black bezel. Up: B-F, Center: B-F, Down: B-A, four blade terminals. Wide-Body, 10A 10A at 12V DC. Pair of switches snaps into panel hole 1.0"W (25.4mm) 1.125"H (28.6mm), and fits panels .030" through .250" thick (.76 to 6.35mm). Actuators are black, white, red or ivory rockers or paddles, with imprint in contrasting black or white. Black plastic bezel. Copper blade terminals. O R BS EF O ER LE T EN E C FO E R O N LY Wide Bezel 56006-02, On-Off-On White actuator, bright bezel. Up: On, Center: Off, Down: On, six screw terminals. 57006-02, On-Off-On White actuator, bright bezel. Up: On, Center: Off, Down: On, six blade terminals. c4 dual Rocker switches Two SP switches in one body. Universal application switches. Snap-in mounting. Phenolic housing and plastic actuator. Narrow Body, 25A 25A at 12V DC. Switch snaps into panel hole 1.45" x .83" (36.8 x 21.1mm), and fits panels .040" through .100" thick (1.0mm to 2.5mm). Silver contacts, brass blade terminals. Black or white actuators, imprinted in contrasting black or white. Black narrow steel bezel 1.57" x .90" (39.0mm x 22.9mm) except where noted. SPST 54201-01, Two Black Rockers, On-Off/On-Off Left switch: On-Off, imprinted "On, Off" Right switch: On-Off, imprinted "On, Off" Four blade terminals. 54203-01, On-Off/Mom On-Off Left black paddle switch: On-Off, imprinted "On, Off" Right ivory paddle switch: Mom On-Off, imprinted "On" Four blade terminals. 54204-01, Hi-Off-Lo/Hi-Off-Lo Left black rocker switch: On1-Off-On2, imprinted "Hi, Lo" Right black rocker switch: On1-Off-On2, imprinted "Hi, Lo" Six blade terminals. 58506-08, On-Off/Mom On-Off Left switch, black: On-Off, imprinted "On, Off" Right switch, white : Mom On-Off, imprinted "On, Off". Four terminals. 54300-01, Red Pilot & Paddle, Mom On-Off Left: Red independent pilot light Right ivory paddle switch: Mom On-Off, imprinted "On, Off" Four blade terminals. 58506-09*, Hi-Lo/On-Off Left switch: white actuator imprinted "Hi, Lo". Right switch: black actuator imprinted "On, Off". Three terminals. The On-Off switch controls power to the Hi-Lo switch. 54401-01, One Rocker, Mom On-Off Left: Black panel Right black rocker switch: Mom On-Off, imprinted "On" Two blade terminals. 54403-01, One Rocker, On-Off-On Left: Black panel Right black rocker switch: On1-Off-On2, imprinted "Hi, Lo" Three blade terminals. Rapid ship item. 24 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com rocker & toggle switches c5 rocker accessories c Bracket Mounting Kit 87167-01BP Bezels for Mounting Switches Side by Side For snap-in mounting of any regular size switch such as 56027 or 58328 series. Bezels can be arranged in a parallel array of any length. Bezels themselves can snap into a panel, or be mounted with the Bracket Mounting Kit. Height 1.90" (48.3mm). Two units are 2.37"W x 2.30"H (60.2 x 58.4mm). Mounting hole in panel should be 2.02"W x 1.90"H (51.3 x 48.3mm) for two bezels. Add 1.03"W (26.2mm) for each additional unit. O R BS EF O ER LE T EN E C FO E R O N LY 87167-01BP For installing an array of switches onto a panel, when throughmounting isn't possible. Use in conjunction with 82159 bezels. Holds from 2 to 6 bezels (not included). Snap-together assembly: no special tools needed. Available only as a retail BP unit, which contains two bracket sections and brass stabilizing rods. Kit brackets engage with bezels. Brass rods snap into brackets to stabilize the unit. Assembled kit mounts on top of or under the panel. Mounting holes .710" x .265" (18.0 x 6.7mm). 82159-1, End Bezel BP Panel Plug Black snap-in panel plug fits standard panel hole .83" x 1.45" (21.1 x 36.8mm). 82159-2, Center Bezel Can be ganged, and used with end bezels. 82159-3, Independent Bezel Fits panel opening 1.900" x 0.984" (48.3 x 25.0mm) BP Retail Kits 82159-02BP BP Contains 2 end bezels, one center bezel, one plug. 82159-03BP BP Contains 2 center bezels. 98628, Plug Face dimensions: 1.91" x 0.96" (24.4 x 48.8mm), designed for use with 82159 series. build any of the 58328 switches Five handy kits cover all the electrical types and pilot light combinations. Each kit comes with a set of snap-in pilot light lenses, so it's easy to make up a switch with the lens color you need. See pages 19 & 20. The five kits are individually retail-packed in clamshell BP units. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 25 rocker & toggle switches c SPDT c6 54100 Series Toggle switches 54103, On-Off-On BP Up: On, Center: Off, Down: On. Three screw terminals. 54100 Series, 25A Standard or lighted handle - black nylon or clear plastic, 11/16" (17.5mm) long. Silver contacts. Mounting stem 15/32"-32 thread, 15/32" (11.9mm) long, fits panels up to 1/8" (31.8mm) thick. Includes mounting hardware: black metal facenut and nickel-plated hexnut. 25A at 12V DC. Terminals: .250" blade or 6-32 screw. 54104, Mom On-Off-Mom On BP Up: Mom On, Center: Off, Down: Mom On. Three screw terminals. 54110, On-Off-On, Illuminated BP Up: On/red, Center: Off/White, Down: On/White. Five screw terminals. Weather-resistant: O-ring seal in bushing. Independent illumination. DPST SPST 54105, On-Off Up: On, Down: Off. Four screw terminals. Illuminated Switch O R BS EF O ER LE T EN E C FO E R O N LY Standard Switch DPDT 54100, On-Off BP Up: On, Down: Off. Two screw terminals. 54107, On-Off-On Up: On, Center: Off, Down: On. Six screw terminals. 54101-01, Mom On-Off BP Up: Mom On, Down: Off. Two blade terminals. 54109, On-Off, Illuminated BP Up: On/Red, Down: Off/White. Four screw terminals. O-ring seal in bushing. 1 B + 2 L1 3 3 1 4 B 6 sealed + Neoprene O-ring seal within the mounting stem protects against moisture and dirt entering around the base of the actuator handle. Some switches are coated in polyvinyl chloride (PVC), providing additional sealing. PVC-coated switches normally have wire leads, which provide complete covering and insulation of the terminals. 4 2 3 3 L1 6 J 54109 independent wiring 1 L1 + B 4 2 3 3 L2 54109 dependent wiring + B 6 1 L1 L2 4 Dependent Illumination When the switch is On, the handle is illuminated. 2 3 3 6 Independent Illumination Actuation of the switch does not affect the illumination of the handle. The switch can be On or Off, and illumination is usually controlled by another switch. This mode can be used to light a whole bank of switches, and is especially useful for locating switches in the dark. J 54110 independent wiring 54110 dependent wiring For wiring of other switches in this series see page 93. Rapid ship item. 26 BP Available in retail clamshell pack. dependent or independent? Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com rocker & toggle switches c7 paddle handle toggle switches 59024-000 Series 1" Paddle Handle Switches 25A Silver contacts, 15/32"-32 thread mounting stem. Fits panels up to 1/4" (6.4mm) thick. Includes mounting hardware: black knurled facenut, hexnut. Keyway is in the down position. 1" (25.4mm) handle, black plastic, matte finish. 25A at 12V DC. Terminals: Brass 8-32 screw or .250 quick connect blade. c SPDT 59024-104, On-On Up: On, Down: On. Three blade terminals. 59024-106, On-Off-On Up: On, Center: Off, Down: On. Three blade terminals. 59024-108, Mom On-Off-Mom On Up: Mom On, Center: Off, Down: Mom On. Three blade terminals. 59024-204, On-On Up: On, Down: On. Three screw terminals. 59024-206, On-Off-On Up: On, Center: Off, Down: On. Three screw terminals. O R BS EF O ER LE T EN E C FO E R O N LY 59024-208, Mom On-Off-Mom On Up: Mom On, Center: Off, Down: Mom On. Three screw terminals. SPST DPST 59024-100, On-Off Up: On, Down: Off. Two blade terminals. 59024-110, On-Off Up: On, Down: Off. Four blade terminals. 59024-101, On-Off Up: On, Down: Off. O-ring seal in the stem. Two blade terminals. 59024-210, On-Off Up: On, Down: Off. Four screw terminals. 59024-102, Mom On-Off Up: Mom On, Down: Off. Two blade terminals. 59024-144, Mom On-Off Up: Off, Down: Mom On. Two blade terminals. 59024-200, On-Off Up: On, Down: Off. Two screw terminals. 59024-201, On-Off Up: On, Down: Off. O-ring seal in the stem. Two screw terminals. 59024-202, Mom On-Off Up: Mom On, Down: Off. Two screw terminals. 59024-244, Mom On-Off Up: Off, Down: Mom On. Two screw terminals. DPDT 59024-116, On-On Up: On, Down: On. Six blade terminals. 59024-118, On-Off-On Up: On, Center: Off, Down: On. Six blade terminals. 59024-216, On-On Up: On, Down: On. Six screw terminals. 59024-218, On-Off-On Up: On, Center: Off, Down: On. Six screw terminals. wiring diagrams See page 93. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 27 c rocker & toggle switches Without Mounting Bracket c8 freightliner toggle switches 59024-12, SPST On-Off Up: On, Down: Off. Two blade terminals. Dual contacts for extra durability. 59024-00 Freightliner Replacement Switches 25A 59024-13, SPDT On-Off-0n Up: On, Center: Off, Down: On. Three blade terminals. Dual contacts for extra durability. Terminals are arranged to match OEM wiring connectors. With or without brackets. Silver contacts. Black phenolic switch housing with metal cap. 15/32"-32 thread mounting stem. Fits panels to .093" (2.4mm) with spacer provided, or to .25" (6.4mm) without spacer. Includes mounting hardware: black metal facenut. Keyway is in the down position. Black plastic 1" (25.4mm) handle, matte finish. Tin-plated blade terminals. 25A at 12V DC. 59024-14, DPST On-Off Up: On, Center: Off. Four blade terminals. 59024-15, DPDT On-Off-On Up: On, Center: Off, Down: On. Six blade terminals. O R BS EF O ER LE T EN E C FO E R O N LY 59024-16, DPST On-Mom Off Center: On, Down: Mom Off. Four blade terminals. c9 lighted tip toggle switches M-54111 Lighted Tip Switches 25A Tip of handle is illuminated Red in the On position, illuminated Clear in the Off position. Silver contacts. 15/32"-32 thread mounting stem. Nickel-plated brass hexnut. Black plastic handle, housing and facenut. Keyway in the down position. Blade terminals. Independent illumination. 25A at 12V DC. With Mounting Bracket 59024-33, SPST On-Off Up: On, Center: Off. Two blade terminals. Dual contacts for extra durability. Plastic facenut can be replaced with black metal facenut 83252 (page 91). 59024-34, SPDT On-Off-0n Up: On, Center: Off, Down: On. Three blade terminals. Dual contacts for extra durability. 59024-35, DPST On-Off Up: On, Center: Off. Four blade terminals. 59024-36, DPDT On-Off-On Up: On, Center: Off, Down: On. Six blade terminals. M-54111-01, SPST On-Off BP Up: On, Down: Off. Four blade terminals. 59024-37, DPST On-Mom Off Center: On, Down: Mom Off. Four blade terminals. M-54111-02, SPDT On-Off-On BP Up: On, Center: Off, Down: On. Five blade terminals. 59024-38, DPDT Mom On-On-Mom On Up: Mom On, center: On, Down: On. Six blade terminals. B + B 2 L 3 6 B20 M-54111-01 Diagram Rapid ship item. 28 BP Available in retail clamshell pack. L1 4 + 1 4 2 L2 3 6 B20 M-54111-02 Diagram Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com rocker & toggle switches c10 heavy duty toggle switches Standard or long handle. Universal application. Silver contacts. Mounting stem is nickel-plated brass 15/32"-32 thread, 15/32" (11.9mm) long, and fits panels up to 9/32" (7.1mm) except where stated otherwise. phenolic housing, with plated steel cap. Nickel-plated brass mounting hardware. Blade terminals: .250 quick connect. Screw terminals: 6-32 screws. 25A at 12V DC, 15A at 24V DC. c 55023, On-Off Up: On, Down: Off. Two screw terminals with 2 blades attached. 55055, On-Off, Long Handle BP Up: On, Down: Off. Two blade terminals. Silver contact surfaces. SPST Momentary Standard handle, 11/16" (17.5mm) long. 55020-04, Off-Mom On, PVC coated Moisture- and dirt-resistant. PVC coated and sealed with an O-ring seal in the stem. Up: Off, Down: Mom On. Two 8" (203.2mm) leads. Silver contact surfaces. O R BS EF O ER LE T EN E C FO E R O N LY Long handle, 1 1/2" (38.1mm) long. 55020, Off-Mom On BP Up: Off, Center: Mom On. Two screw terminals. Silver contact surfaces. PVC coated housing with wire leads. 55052-01, On-Mom Off, long handle Up: On, Center: Mom Off. Two blade terminals. Silver contact surfaces. SPDT SPST 5520, On-Off BP Up: On, Down: Off. Two screw terminals. O-ring seal. 5582, On-Off BP Up: On, Down: Off. Two screw terminals. Silver contact surfaces. 5582-10, On-Off, PVC Coated Up: On, Down: Off. Two 8" (203.2mm) leads. O-ring seal. Mounting stem is 11/32" (8.7mm) long, and fits panels up to 3/16" (4.8mm) thick. Silver contact surfaces. 55014, On-Off BP Up: On, Down: Off. Two blade terminals. Silver contact surfaces. 55014-05, On-Off Up: On, Down: Off. Two blade terminals. O-ring seal in the stem. Silver contact surfaces. 5584, On-On Up: On, Down: On. Three screw terminals. Silver contact surfaces. 5586, On-Off-On BP Up: On, Center: Off, Down: On. Three screw terminals. Silver contact surfaces. 55015, On-On Up: On, Down: On. Three blade terminals. Silver contact surfaces. 55016, On-Off-On Up: On, Center: Off, Down: On. Three blade terminals. Silver contact surfaces. 55036, On-Off-On, PVC Coated BP Up: On, Center: Off, Down: On. PVC coated housing, with three 9.5" (241.3mm) leads. Leads have tinned brass terminals. O-ring seal in the stem. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 29 c rocker & toggle switches SPDT Momentary 55065-02, Mom On-Off-Mom On, Long Handle Up: Mom On, Center: Off, Down: Mom On. Six blade terminals. Silver contact surfaces. 55021, Mom On-Off-Mom On BP Up: Mom On, Center: Off, Down: Mom On. Three screw terminals. Silver contact surfaces. 55021-07, Mom On-Off-Mom On, PVC Coated Up: Mom On, Center: Off, Down: Mom On. PVC coated housing with three 8" (203.2mm) leads. O-ring seal in the stem. Mounting stem is 11/32" (8.7mm) long, and fits panels up to 3/16" (4.8mm) thick. BP 55065-03, Mom On-Off-Mom On BP Up: Mom On, Center: Off, Down: Mom On. Six blade terminals. Silver contact surfaces. DPDT Reversing Polarity 55033-01, Mom On-Off-Mom On Up: Mom On, Center: Off, Down: Mom On. Three blade terminals. Silver contact surfaces. Forward/reverse switch for use with permanent magnet motors. 55046, Mom On-Off-Mom On Up: Mom On, Center: Off, Down: Mom On. Four blade terminals. 55088, On-Off-Mom On Up: On, Center: Off, Down: Mom On. Three screw terminals. Silver contact surfaces. O R BS EF O ER LE T EN E C FO E R O N LY c11 medium duty off-on switches DPST SPST Down: Off, Up: On. Standard or ball handle. Nickel-plated brass handle, facenut and mounting stem. Silver contacts. Mounting stem has 15/32"-32 thread, 15/32" (11.9mm) long, and fits panels up to 9/32" (7.2mm) thick. Screw or blade terminals, or wire leads. Phenolic housing with plated steel frame. Keyway is in the down position. 10A at 12V DC. 55017, On-Off BP Up: On, Down: Off. Four blade terminals. Silver contact surfaces. DPDT 5590, On-On Up: On, Down: On. Six screw terminals. Silver contact surfaces. 5592, On-Off-On BP Up: On, Center: Off, Down: On. Six screw terminals. Silver contact surfaces. Ball handle: 3/8" (9.52mm) long. Standard handle: 11/16" (17.46mm) long. 55018, On-On BP Up: On, Down: On. Six blade terminals. Silver contact surfaces. 5507, Ball Handle, Two Screw Terminals 55019, On-Off-On BP Up: On, Center: Off, Down: On. Six blade terminals. Silver contact surfaces. 5568, Ball Handle, to 6" Leads 5558, Standard Handle, Two Screw Terminals 55057, On-Off-On, Long Handle Up: On, Center: Off, Down: On. Six blade terminals. DPDT Momentary 55054, Mom On-Off-Mom On BP Up: Mom On, Center: Off, Down: Mom On. Six screw terminals. Silver contact surfaces. SPST or SPDT? 55054-04, Mom On-Off-Mom On, Long Handle Up: Mom On, Center: Off, Down: Mom On. Six screw terminals. Rapid ship item. 30 BP Available in retail clamshell pack. Check out page 92 for a graphic explanation of SPST SPDT DPST and DPDT. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com rocker & toggle switches c12 551800 series toggle switches 551800 Series Heavy Duty & Extra Heavy Duty Switches 20A and 30A Universal application. Diecast housing. For stem- or bracket-mounting. 15/32"-32 thread mounting stem, with keyway. Extra Heavy Duty 30A at 6-12V DC, 15A at 24-36V DC. Silver-plated contacts. 551840, SPST On-Off BP Up: On, Center: Off. Two screw terminals. 551841, SPST Mom On-Off Up: Mom On, Center: Off. Two screw terminals. This universal switch can also be used to control day signaling lamps. 551842, SPDT On-Off-On BP Up: On, Center: Off, Down: On. Three screw terminals. 551843, SPDT On-Off-Mom On Up: On, Center: Off, Down: Mom On. Three screw terminals. 551844, SPDT Mom On-Off-Mom On Up: Mom On, Center: Off, Down: Mom On. Three screw terminals. O R BS EF O ER LE T EN E C FO E R O N LY Brackets: .170" (4.3mm) diameter holes, 1.72" (43.7mm) on centers. Fits panels up to 3/16" (4.8mm) thick. Chrome plated brass handle, 1 1/16" long (27.0mm). Steel screw or blade terminals. Plated steel hexnut. c Heavy Duty 20A at 6-12V DC. 551000*, SPST On-Off Up: On, Center: Off. Two blade terminals. 551001, SPST Mom On-Off Up: Mom On, Center: Off. Two blade terminals. 551845, DPST On-Off Up: B-2, Center: Off. Four screw terminals. 551846, DPDT On-Off-On Up: On, Center: Off, Down: On. Six screw terminals. 551800, SPST On-Off Up: On, Center: Off. Two screw terminals. 551849, SP3C On-On-Off Up: B-T-H, Center: B-P-T, Down: Off. Four screw terminals. This universal switch can also be used to control headlamps and Park & Tail lamps. 551801, SPST Mom On-Off Up: Mom On, Center: Off. Two screw terminals. 551850, SPDT On-On Up: On, Center: On. Three screw terminals. 551802, SPDT On-Off-On Up: On, Center: Off, Down: On. Three screw terminals. 551851, SPST On-Mom Off Up: Mom Off, Center: On. Two screw terminals. This universal switch can also be used to control night signaling lamps. 551805, SPDT On-Off Up: On, Center: Off. Four screw terminals. 551806, DPDT On-Off-On Up: On, Center: Off, Down On. Six screw terminals. M-594, SPST On-Off BP Up: On, Center: Off. Two screw terminals. Golden dichromate dip housing, brass terminals. 551852, SP2C On-On-Off Up: B-H, Center: B-L, Down: Off. Three screw terminals. This universal switch can also be used to control heaters/defrosters. Supplied without resistors. 551855, SP1C Mom Off-On-Off Up: Mom Off, Center: On, Down: Mom Off. Two screw terminals. This universal switch can also be used to control signaling and marker lamps. interactive catalog 551861*, SP2C On-Off Up: On B-1&2, Center: Off. Three screw terminals. Check the Cole Hersee website at www.colehersee.com You can do an interactive search for the exact item you need by going to `Product Catalog'. And there's an abundance of other product information, such as technical drawings and specs. 551862, DP2C Mom On-Run-Off Up: Mom S-S, Center: Open, Down: Off M-M. Four screw terminals. This universal switch is primarily used to control magneto ignition. For battery ignition see 59071 and 55094. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 31 c rocker & toggle switches DP Ignition/Start c13 specialized toggle switches Silver contacts. 15/32"-32 thread mounting stem, .46" (11.9mm) long, mounts in panels up to 9/32" (7.1mm) thick. Nickel-plated brass handle: standard .687" (17.5mm) or long 1.5" (38.1mm). Brass blade terminals. Black phenolic housing with metal frame. Nickel-plated brass hardware. Keyway is in the down position. 25A at 12V DC, except as noted. 55058-01, 4-Pole, 4-Circuit Headlamp Switch Allows splitting of a heavy load into four separate circuits. Eight blade terminals. Long handle. Up: Park, Tail & Headlamps- Center: Off - Down: Park, Tail & Auxiliary Lamps. A B Recessed Switch P B B T 59071, Off-On-Mom On 25A at 12V DC Down: Off, Center: On 4&5, Up: Mom On 1, 4&5. White plastic handle. Three blade terminals. 5543, SPST Off-On Switch In Recessed Plate Silver contacts. 15/32"-32 thread mounting stem, .46" (11.9mm) long, mounts in panels up to 9.32" (7.1mm) thick. Brass blade terminals. Black phenolic housing with metal frame. Keyway is in the down position. B H O R BS EF O ER LE T EN E C FO E R O N LY A Auxiliary lamps B Battery+ H Headlamps P Parking lights T Tail lights 55064, DPDT 4-Circuit Headlamp Switch B24 55058-01 Diagram Up: Park, Tail & Headlamps - Center: Off - Down: Park, Tail & Auxiliary Lamps. Six blade terminals. Long handle. P 1 B 2 T 3 A 4 5558 switch mounted in 5543-15 recessed plate to prevent damage or accidental actuation inside a trailer or other location. Plate fits into a 2" dia (50.8mm) panel hole. Depth is 1.75" minimum (44.5mm).Two screw terminals. Also available: 5543-09 recessed plate with 55015-03 SPDT On-On switch (suitable for 3-way lighting applications). Recessed plate is available in different colors, by special order- contact Cole Hersee. B 5 6 H A Auxiliary lamps B Battery+ H Headlamps P Parking lights T Tail lights 55071, DP 2-Circuit Marker Lamp Switch B24 55064 Diagram Up: Mom On B, 1&2 (day signaling) - Center: On 1&2 - Down: Mom Off (night signaling). Three blade terminals. Standard handle. M S 2 1 6 B B Battery+ M Marker lamps S To Marker lamps switch 5543-15, Recessed Faceplate Switch Guard Faceplate only: does not include switch. Needs to be countersunk in a 2" (50.8mm) hole. 3 3/16" (81.0mm) diameter with three 7/32" (5.6mm) holes on a 2 3/4" (69.9mm) diameter circle. Requires a clearance depth of .890" (22.6mm), not including clearance for a switch. Other colors, metals and finishes are available on special order. Contact Cole Hersee. 55015-03*, 3-Way Lighting Switch SPDT On-On. Three blade terminals. B24 55071 Diagram Rapid ship item. 32 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com rocker & toggle switches c 83252 Black Facenut c14 accessories Switch Guard Brass facenut, black finish. For 54100 series switches, to replace plastic facenut. Terminal Blade Adapter 55023-10 Attaches to a No. 6 screw terminal, converting to a standard 1/4" wide blade terminal. Brass. 100 pieces per package. O R BS EF O ER LE T EN E C FO E R O N LY 82468, Flip Cover Switch Guard BP Provides the maximum protection, and can be easily added to an already installed switch by unscrewing and replacing the facenut. Spring-loaded snap action cover returns the switch to the `safe' position when closed, and secures it there. Rugged red melamine cover is colorfast at temperature extremes and is resistant to most contaminants, like fuel oil. Other colors are available by special order. Recommended for use with standard 11/16" toggle handle Off-On or On-On switches with a keyway in the bushing. Steel faceplate with black glossy finish. Height closed 1.08" (27.4mm); height open 1.71" (43.5mm). 1.80" (45.8mm) long x .67" (17.0mm) wide. Mounting hole diameter .47" (11.9mm). Accepts switches with standard 15/32" diameter mounting stems. Toggle Boot Seals With cover up. With cover closed. Handle Extensions Rigid plastic extension snaps over standard or ball handled toggle switches, extending a standard handle to 1 7/8" (47.6mm) long. Enables switches to be easily color-coded. Packed 10 of each color per package. Durable silicone rubber bonded to a standard 15/32"-32 thread nickel plated brass hexnut. When the nut is tightened to the stem of a toggle switch, the rubber forms an O-ring seal with the panel. Full boots completely cover a standard 11/16" (17.5mm) handle. Boot seals protect switches from moisture and dirt. 81264, Gray BP 81264-01, Black BP 81271, Red 81272, Yellow 81273, Black O-Ring Seal 81261*, Fluorescent Green 81262, Fluorescent Blue 81263, Fluorescent White Faceplate 8250, Nickel-Plated Fit all toggle switches with standard 15/32" diameter mounting stem and keyway. Nickel-plated steel. 1" x 5/8" (25.40 x 15.87mm). Stamped On, Off. Half-Boot Seal 81255 BP Allows any length of handle to protrude, yet seals tightly to handle. Suitable for all toggle switches in this catalog excepting squared handle switches as on page 26. O-Ring Seal Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 33 battery-related products D M-284 BP Same as M-284-01, but with copper contacts, and UL label. D1 Master Disconnect switches Single Pole M-284-A BP Same as M-284-01, but without UL label. Two positions: Off-On. For 6-36V DC systems. Will disconnect the battery circuit only. Electrical Ratings (unless noted): 1000A intermittent, 175A continuous. UL Listed 707B: 800A intermittent, 175A continuous. UL Listed 375M: 250A at 6V, 125A at 12V intermittent; 40A at 6V, 20A at 12V continuous. Electrical ratings on UL labels are conservative. M-284-02, Weather-Resistant BP Same as M-284-01, but with O-ring seal in operating shaft, gasket-sealed terminal insulator and diecast lever with protective dichromate finish, and without UL label. Also available with faceplate (M-284-09BP) 2484-16 Mounting stem: Brass, 3/4" -16 thread, 23/32" (18.3mm) long. Fits panels up to 3/16" (4.8mm) thick. Terminals: Two 3/8" -24 studs. Case: Plated steel. Contacts: Silver. UL labeled. 75908, 2000A, High Current, Weather-Resistant Disconnects battery circuit only. Electrical rating: 2000A intermittent. 30 seconds On, 3 minutes Off, 300A continuous. Mounting stem: 3/4" -16 thread. Fits panels up to 1/4" (6.4mm) thick. Terminals: Two 1/2" -20 copper studs. Case: Plated steel. Sealing: sealed between shaft and mounting stem; case and terminal insulator. O R BS EF O ER LE T EN E C FO E R O N LY With Diecast Lever Also available as double pole (75907) 2484-A Same as 2484-16, but without UL label. 2484-09 Same as 2484-16, but with copper contacts, and without UL label. 2484-06 Same as 2484-16, but weather-resistant with O-ring seal in operating shaft, gasket-sealed terminal insulation and sealant in mounting stem and case, and without UL label. With Hencol Lock 2484-02 Mounting stem: Brass, 3/4" -16 thread 17/32" (13.5mm) long. Fits panels up to 1/4" (6.4mm) thick. Terminals: Two 3/8" -24 studs. Plated steel case, silver-laminated contacts. Hencol lock and 2 keys. Indexing pin. 2484 Same dimensions as 2484-16, but with copper contacts and ratings: UL labeled. M-284-01, Long Stem, Brass Case BP Mounting stem: Brass 3/4" -16 thread (19.1mm), 1 13/32" (46.1mm) long. Fits panels up to 15/16" (23.8mm) thick. Terminals: Two 3/8" (9.5mm) diameter studs. Actuator: Chrome-plated lever. Silver-laminated contacts. UL labeled. MARINE LISTED wiring See page 96. Rapid ship item. 34 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com battery-related products Double Pole Two positions: Off-On. For 6-36V DC systems. Will disconnect the battery and the alternator or generator field circuit. Electrical ratings: Large studs: 1000A intermittent. 15 seconds On, 5 minutes Off. 125A continuous (unless noted). Small studs: 20A continuous. With Diecast Lever 75903, Steel Case Chrome-plated diecast lever. Plated steel case. Brass mounting stem 3/4" -16 thread 23/32" (18.3mm) long. Fits panels through 3/16" (4.8mm) thick. Two 3/8" -24 and two 10-32 studs. D 75907, 2000A, High Current, Weather-Resistant Electrical ratings: Large studs: 2000A intermittent, 30 seconds On, 3 minutes Off. 300A continuous. Small studs: 20A continuous. Plated steel case. Chrome-plated diecast lever. Mounting stem 3/4" -16 thread, fits panels through 1/4" (6.4mm) thick. Two 1/2" -20 copper and two 10-32 studs. Sealed between shaft and mounting stem, and case and terminal insulator. With indexing pin. Also available as single pole (75908). With Hencol Lock O R BS EF O ER LE T EN E C FO E R O N LY 75904-02 75904, Steel Case, Silver Contacts Same as 75903, but with laminated silver contacts. M-290-05, UL-Listed Brass case. Silver laminated contacts. Chrome-plated diecast lever. Brass mounting stem 3/4" -16 thread 1 13/32" (46.1mm) long. Fits panels through 15/16" (23.8mm) thick. Two 3/8" -24 and two 10-32 studs. Labeled UL 707B. MARINE LISTED Two Hencol keys. Plated steel case. Silver-laminated contacts. Brass mounting stem 3/4" -16 thread 17/32" (13.5mm) long. Fits panels through 1/4" (6.4mm) thick. Two 3/8" -24 and two 10-32 studs. With indexing pin. 75904-03 Same as 75904-02, except with O-ring seal in the operating shaft. For Two High Current Loads 75912 75904-01, Weather-Resistant, with Indexing Pin and O-Ring Diecast lever. Plated steel case. Silver-laminated contacts. Brass mounting stem 3/4" -16 thread 17/32" (13.5mm) long. Fits panels through 1/4" (6.4mm) thick. Two 3/8" -24 and two 10-32 studs. O-ring seal in the operating shaft, and gasket-sealed terminal insulator. Electrical ratings: 125A continuous, 750A intermittent; 15 secs On, 5min Off. Up to 36V DC max, carry only. Silver contact surfaces. Both poles are separately insulated. Four 3/8" -24 studs. Lockwasher and two brass hexnuts per stud are provided. 3/4" -16 brass mounting stem. Operating temperature range: -40 to 85F (-40 to 29C) O-ring seal in mounting stem; gasket seal at terminal insulator. Epoxy seal at case, mounting stem and locating pin. Heavy duty plated steel case. With indexing pin. Mounting torque 20ft lbs (27 Nm); stud torque 4.4 to 7.4 ft lbs (6-10Nm). Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 35 battery-related products D A selector switch allows use of the first battery, the second battery, or both batteries simultaneously. This provides back-up starting power in an emergency. Either or both batteries can be selected for energizing. battery selector/ D2 master disconnect switches For any vehicle that needs to use two batteries where one battery is used for starting the engine, while the other is used to power auxiliary loads. This is a common situation in trucks, boats, RVs, police and rescue vehicles, and in ambulances and fire equipment. These switches combine the functions of Battery Selector and Master Disconnect Switches to give four battery power options: M-750, Basic Switch MARINE MARINE LISTED LISTED * Power cut off at the source. * Power On, Battery 1. * Power On, Battery 2. * Power On, both Batteries. Battery selector switches provide a positive battery disconnect, which has many advantages: * It gives a reliable shutdown of power during maintenance. * The version with the key protects against theft of the vehicle, when unattended. * It helps protect against electrical fires, when the vehicle is not in use, and minimizes battery drain. O R BS EF O ER LE T EN E C FO E R O N LY M-751, With Keys See chart on next page for additional models. Back of Switch MARINE LISTED MARINE LISTED Electrical Ratings MARINE MARINE LISTED LISTED Labeled UL 707B. Rating: 500A intermittent, 310A continuous, 6-36V DC Electrical ratings on UL labels are conservative. Use with either alternators or generators. Make before break design permits operation through the three On positions with the engines running. Engines should always be shut down before turning to Off. Wiring instructions are included. Heavy-Duty Construction Vaporproof, weather-, dust- and corrosion-resistant. Durable, fracture-resistant high temperature plastic case, knob and insulator. Switches conform to USCG section 183.410 for ignition protection. Resistant to impact, and temperature extremes. Heavy duty copper stud terminals, with brass hexnuts. Can be surface mounted, or installed through a 3 5/16" diameter hole in the panel (use label No. 563. See Section F4.) Dimensions: Flange: 6" (152.4mm) diameter, overall height 2 5/8" (66.7mm). Terminals: 3 copper studs, 3/8" (9.5mm) diameter. Eight Models For Every Application: Model M-754 is shown. The three small terminals in the middle are for connection to the pilot light circuit. M-754-01, M-755 and M-755-01 are similar. Models M-752 and M-753 have two small terminals in the middle marked F1 and F2 for connection to the Alternator Field Disconnect circuit. M-750 and M-751 have no small terminals in the middle. Full wiring instructions are included. Rapid ship item. 36 BP Available in retail clamshell pack. MODEL M-750 M-751 M-752 M-753 M-754 M-754-01 M-755 M-755-01 Lock AFD Pilots Pilot Circuit Lock: With key lock and two keys. AFD: Alternator field disconnect circuit switch. Prevents possible alternator diode failure if the switch is accidentally turned to Off with the engines running. Pilots: Supplied with two separate green pilot lights PL-118GC001. Pilot Circuit: With pilot indicator light circuit. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com battery-related products D3 Accessories Face Plates 82065, Without Indexing Hole For Master Disconnect Switches. Polished aluminum with enamel finish. Fits Cole Hersee Master Disconnect Switches without indexing pin. 2 1/2" (63.5mm) diameter. 82065-02, With Indexing Hole 563 Switch Position Label for M-750 Series Pressure-sensitive label for Dual Battery Selector & Master Disconnect Switches. Useful when the switch is mounted through a panel. Battery Jumper Terminals and Studs O R BS EF O ER LE T EN E C FO E R O N LY 24505, Lockout Lever Kit Special lever and flange plate accept a padlock to securely lock a Disconnect Switch in the Off position, which is required by many lock-out/tag-out safety regulations. For use with Cole Hersee lever actuated master disconnect switches with a 3/4" diameter (19.1mm) mounting stem: 2484, 2484-A, 2484-06, 2484-09, 2484-16, 75903, 75904, 75904-01, M-284, M-284-A, M-284-01, M-284-02, M-289, M-290, M-290-01, M-290-05. (We recommend the use of a padlock with a 5/16" (7.9mm) diameter shackle.) D lockouts/tagouts Lockouts and tagouts prevent operators, technicians and maintenance personnel from unanticipated power-ups that might cause injury or death. According to OSHA, "A lockout device utilizes a positive means such as a lock to hold an energy isolating device in a safe position and prevent the energization of a machine." A tagout is a tag or seal that states `Do not operate or remove this tag' and is signed by the person who places the tagout. Procedures specify that nobody but that person may remove the tag. Use them to make easily-accessible battery connections, inside or outside the vehicle. Can be used individually or in pairs. Easy to install. Solid brass posts. Includes brass hexnut and lockwasher. Jumper terminals have contact post 13/16" (20.6mm) diameter, 1 1/8" (28.8mm) long, which is grooved to accept standard jumper cables 6-48V DC. 46210-02, Post with Red Cap for Positive Terminals 97846-A, Replacement Red Cap A lockout on a battery switch not only keeps a vehicle safe, but also immobilizes it. A locked out vehicle is less vulnerable to battery drain or theft. 80101-B, Replacement Lever Chrome-plated diecast lever. Fits all Cole Hersee lever-actuated Master Disconnect Switches. 46210-03, Post with Black Cap for Negative Terminals 97846-B, Replacement Black Cap 83353, Hencol Key For Hencol trouble-free locks. Heavy gauge plated steel resists corrosion. 46211-01, Black Battery Feeder Stud Same as 46211-R, only black plastic. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 37 D battery-related products 46211-R, Red Battery Feeder Stud Brings 6-36V DC power through bulkheads or firewalls. Impactresistant plastic insulator/mounting bushing, 1 17/64" (32.1mm) diameter, 5/8" (15.9mm) long. Two 3/8" -16 thread brass stud terminals, 5/8" (15.9mm) long. 48122, 140 Amp Terminations: three 5/16" (7.9mm) studs and one No.10 stud. Four 9/32" (7.2mm) diameter mounting holes. Size: 6"L x 4 13/16"W x 3 11/32"H (152.4 x122.2 x 84.9mm). 3188, Copper Cable Terminal 0.46" (11.7mm) diameter for 0AWG or 00AWG cable. 150A. 13/32" (10.3mm) diameter hole for 3/8" (9.5mm) stud. O R BS EF O ER LE T EN E C FO E R O N LY 48162, 200 Amp Terminations: three 5/16" (7.9mm) studs and one No.10 stud. Four 9/32" (7.2mm) diameter mounting holes. Size: 8 1/2"L x 4 3/16"W x 3 13/32"H (215.0 x 122.2 x 86.5mm). D4 Battery Isolators For vehicles with two batteries, these devices electrically isolate the batteries to prevent the battery with the higher charge from draining into that with the lower charge. In addition, both batteries can be charged simultaneously from one source. For 12-36V DC negative ground systems (48051 is for 12V DC only). The electronic components are embedded to give excellent protection from adverse conditions, such as contamination and vibration. The integral heat sink provides efficient heat dissipation. The amp rating of each item is the maximum alternator rating. Most alternators on new vehicles have an integral electronic voltage regulator that requires the use of the 4-stud battery isolator. The small 4th stud is for connection to a circuit switched by the ignition switch. The newer alternators were first introduced by Delco and are therefore sometimes called `Delcotron-type alternators'. Battery Isolators have a `per leg' rating which indicates the maximum current that it can deliver to each battery. All Cole Hersee Battery Isolators have a per leg rating equal to half the alternator rating. Thus a 48092 battery isolator with an alternator rating of 90A has a per leg rating of 45A per leg. 3-Stud Battery Isolators For use with alternators that do not have an integral electronic voltage regulator. 48080, 42 Amp Terminations: one 10AWG 6" (152.4mm) wire lead, two 12AWG wire leads. Two 13/64" (5.2mm) diameter mounting holes. Size: 5"L x 3 1/4"W x 2 3/16"H (127.0 x 82.6 x 71.0mm). 4-Stud General Purpose Isolators For use with Delcotron-type alternators. Four studs. 48092, 90 Amp Terminations: three 1/4" (6.4mm) studs and one No. 10 stud. Two 9/32" (7.2mm) diameter mounting holes. Size: 6 1/2"L x 3 1/4"W x 2 13/16"H (165.0 x 82.6 x 71.0mm). Rapid ship item. 38 BP Available in retail clamshell pack. 48070, 70 Amp Terminations: three 1/4" (6.4mm) studs. Two 9/32" (7.2mm) diameter mounting holes. Size: 5"L x 3 1/4"W x 2 3/16"H (127.0 x 82.6 x 71.0mm). Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com battery-related products 48090, 90 Amp Terminations: three 1/4" (6.4mm) studs. Two 9/32" (7.2mm) diameter mounting holes. Size: 6 1/4"L x 3 1/4"W x 2 3/16"H (165.0 x 82.6 x 71.0mm). D 48161, 250 Amp Same as 48160, but with Schottky diodes. Terminations: three 5/16" (7.9mm) studs. Four 9/32" (7.2mm) diameter mounting holes. Size: 8 1/2"L x 4 3/16"W x 3 13/32"H (215.0 x 122.2 x 86.5mm). 48120, 140 Amp Terminations: three 5/16" (7.9mm) studs. Four 9/32" (7.2mm) diameter mounting holes. Size: 6 1/4"L x 4 3/16"W x 3 11/32"H (152.4 x 122.2 x 84.9mm). O R BS EF O ER LE T EN E C FO E R O N LY D5 low voltage disconnect switches SureStartTM Automatic Low Voltage Disconnect Switch 48510 48160, 200 Amp Terminations: three 5/16" (7.9mm) studs. Four 9/32" (7.2mm) diameter mounting holes. Size: 8 1/2" L x 4 3/16" W x 3 13/32" H (215.0 x 122.2 x 86.5mm). Ensures ample starting capacity and prolongs battery life. Automatically disconnects non-critical loads from a battery when the battery voltage falls below a predefined threshold. Automatically reconnects the loads to the battery when it is being charged. Manual override permits a user to make or break the connection, regardless of battery voltage. Overcurrent, Short-circuit and over-temperature protection. 200A 12V DC Optional output for a visual or audible alarm.Optional Run/Ign override. For Ambulances Used to isolate medical equipment batteries from vehicle batteries. With Schottky diode, to comply with Federal Specification KKK-A-1822B for ambulances. 48051, 75 Amp at 12V DC Two studs, two mounting holes. Size: 5" L x 3 1/2" W x 3 1/3" H (125.4 x 88.9 x 84.9mm). No more stranded vehicles and jumpstarts! SureStartTM LVD helps reduce fleet downtime and battery warranty issues. SureStartTM LVD saves batteries on vehicles that are idle for extended periods, such as rental fleets, agricultural vehicles and construction equipment. See page 99 for wiring schematic. Check out the Cole Hersee website for related items. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 39 solenoids & relays E 24144, 200A Electrical Rating: 200A carry only. Not to break 200A at 24V DC. Silver contacts. E1 Steel & Phenolic Body Solenoids Continuous Duty 85A except where noted. Normally Open contacts, SPST, One circuit: Off - On. Housings: Plated steel (Phenolic where noted). Contacts: Copper 5/16" -24 thread, hexnuts and lockwashers included. 200A solenoids have silver contacts. Coil, ignition and ground terminals: Steel 10-32 thread, hexnuts and lockwashers included. Bracket mounting holes 5/16" x 19/32" (7.9 x 15.1) on 2 13/64" centers (56.0mm). 2 3 1 4 36V Insulated 24080 PVC coated model: see 24135 24V Grounded 24124 3 O R BS EF O ER LE T EN E C FO E R O N LY 2 2 1 4 1 24080-01, UL-Listed Same as 24080, but UL and CE rated. Continuous Rating: 65A at 36V DC. Intermittent rating: 120A make, 65A break. 10 sec On, 30 min Off. MARINE MARINE LISTED LISTED 3 12V Insulated 24115 2 24V Insulated 24063 PVC coated and UL-rated model: see 24063-08 2 1 3 BAT + 3 1 24059 BP PVC-coated models: see 24117 & 24117-01 4 2 3 24107 2 1 1 Rapid ship item. 40 BP Available in retail clamshell pack. 3 BAT + 24059-08, UL Listed BP Same as 24059, but UL and CE rated. Continuous Rating: 65A at 12V DC. Intermittent rating: 750A make, 100A break. 10 sec On, 30 min Off. 4 MARINE MARINE LISTED LISTED Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com solenoids & relays E 6V 24143, 200A Electrical Rating: 200A carry only. Not to break 200A at 24V DC. Silver contacts. 24097, Insulated 2 2 3 3 1 1 4 4 Two Circuits, DPST 24420, Normally On Continuous Duty 35A. Normally Off and Normally On. Special application: for forward and reverse systems in electric golf carts, garden tractors, fork lift trucks, winches, etc. Housing: Steel. Continuous Duty, Normally Closed contacts 35A, Normally Open contacts 85A. 1 2 O R BS EF O ER LE T EN E C FO E R O N LY 24400, 36V Insulated 2 3 1 3 5 6 24402, 24V Insulated Schematic and picture same as 24400. 12V Grounded 24106 4 4 BP 24401, 12V Insulated Schematic and picture same as 24400. PVC coated model: see 24401-04. 2 24401-01, 12V Grounded 1 2 3 1 3 24082, Curved Bracket 5 Latching Solenoid 2 1 4 3 12V Continuous Duty, 110A (carry only). Insulated. Plated steel housing. Requires only a momentary application of coil power to operate. Very little heat is generated, because the coil is de-energized when the solenoid is On. Momentary Switch 24200 + BAT 2 3 LOAD 1 Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. 4 Minimum order quantity may apply. 41 E solenoids & relays Intermittent Duty 12V grounded, Normally Off, SPST, One Circuit: Off - On Resistor Shorting Circuit In this application, 3 is Normally Open. It becomes common with 1 and 4 when the solendoid is energized. Commonly used in engine starting applications. 750A make, 100A break, 10sec On, 20min Off, except where noted. Contacts: Copper. Terminals: Copper. Small ignition and ground terminals are 10-32 thread. Large contact terminals are 5/16" -24 thread. Hexnuts and lockwashers are included. Bracket mounting holes 5/16 x 19/32," 2 13/64" on centers (7.9 x 15.1, 56.0mm) and plated steel housing, except where noted. 2 3 RESISTOR SHORTING CIRCUIT 1 4 12V grounded 24103 2 3 O R BS EF O ER LE T EN E C FO E R O N LY 1 24037 PVC coated model: see 24071, page 43. 24021, Phenolic Housing Bracket mounting holes 9/32 x 1/2," 2 13/64" on centers (7.2 x 12.7, 56.0mm). Contact terminal 5/16" -24 thread. 24044, Curved Bracket 12V insulated 24047 2 24022, Phenolic Housing Bracket mounting holes 9/32" x 25/64," 2 7/64" on centers (7.1 x 9.9, 53.6mm). 1 3 4 24060 2 1 Rapid ship item. 42 BP Available in retail clamshell pack. 3 BAT + Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com solenoids & relays 24046 E 24117, 12V SPST Continuous Duty: 85A. 2 24117-01, 12V SPST UL Listed 1 BP Continuous Duty: 65A at 12V DC Intermittent Duty: 750A make, 100A break. 10 sec On, 30 min Off. 3 BAT + MARINE MARINE LISTED LISTED 24401-04, 12V SPDT Normally Closed contacts 35A, Normally Open contacts 85A. Without PVC coating: see 24401Intermittent Duty SPST, normally Off, 750A make, 100A break 750A make, 100A break. 10 sec On, 20 min Off. Bracket mounting holes 5/16 x 11," 2 13/64" on centers (7.9 x 15.1, 56.2mm). Contact terminals 5/16" -24 thread. 24023, Phenolic Housing Bracket mounting holes 5/16" x 9/32," 2 9/16" on centers (8.1 x 7.2, 65.1mm). 3 2 O R BS EF O ER LE T EN E C FO E R O N LY 2 1 4 3 1 4 5 6 2430, Phenolic Housing 2 Intermittent Duty 24071, Grounded 12V SPST 1 3 BAT + 2 E2 PVC Coated Solenoids Weatherproof: Housing is completely PVC coated. Steel housings. 1 3 Continuous Duty Insulated SPST, Normally Off (except 24401-04). One circuit: Off - On. Bracket mounting holes 5/16" x 19/32" (7.9 x 15.1) on 2 13/64" centers (56.0mm). 2 3 1 4 power on, power off 24063-08, UL Listed 24V SPST Continuous Duty: 65A at 24V DC Intermittent Duty: 120A make, 65A break. 10 sec On, 30 min Off. MARINE MARINE LISTED LISTED Color-coded buttons make it easy to select On and Off functions. See page 51. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 43 E solenoids & relays Motor Reversing Solenoid 12V E3 Plastic body solenoids Glass-filled nylon construction - lightweight, durable and resistant to corrosion. DPDT intermittent duty. 12V DC. Common ground coil. Two blade coil terminals, 5/16" -24 large studs. Copper contacts. F bracket. 75A make and break, maximum On time 5 mins. 125A make and break, maximum On time 30 secs. 150A make and break, maximum On time 0.5 secs. Allow 5 mins Off after max On time. Maximum operating voltage 14.5V DC. Cycle life 10,000 cycles at 5 secs On, 25 secs Off. Shipped with mounting hardware. Heavy Service, 225A For use with heavy vehicles, materials handling, hydraulic systems, large DC machinery, and electric vehicles. SPST normally open contacts. Insulated. 12-48V DC. Use in conjunction with one of many types of Cole Hersee SPDT momentary switches: rocker (such as 58027-04), rotary (such as 72154-01/02) or ignition-type keyed switch (such as 75705-01). L bracket. Large studs: 5/16"-24, two 10-32 stud coil terminals. 12V silver contact, 50k cycles. Copper contact. Maximum operating voltage 14V DC, cycle life 25,000 minimum. 36V type: maximum operating voltage 36V DC, cycle life 50,000 minimum. 48V type: maximum operating voltage 48V DC. Cycle life: 50,000 minimum. Bracket mounting holes 5/16" x 19/32" (7.9 x 15.1) on 2 13/64" centers (56.0mm). Other types available by special order. Also available as 24V: 24450-02 with same rating as 24450. Contact Cole Hersee. 24450 + BP T1 T2 O R BS EF O ER LE T EN E C FO E R O N LY 2 BAT 3 + Forward 1 Continuous Duty, 100A For starting small engines, including lawn tractors, golf carts and sweepers. SPST normally open contacts. 100A make and break, 400A inrush. Silver contacts. Maximum operating voltages: 14V for 12V type; 27V for 24V type; 36V for 36V type. Large studs: 5/16" -24. Continuous Duty 225A make and break, 600A inrush. Silver contacts. Reverse MOTOR 4 L bracket 24848, 48V BAT 2 3 Insulated. Shown: F bracket, stud terminals. 24836, 36V Silver contacts. 24824-01, 24V Silver contacts. 24812, 12V 1 4 2 Copper contacts. 24812-01, 12V Silver contacts. Grounded. Shown: F bracket, stud terminal. Intermittent Duty 1 3 24636, 36V Insulated L bracket, two 10-32 stud coil terminals. 600A inrush. 24824-04, 24V Copper contacts. 24624-10, 24V Insulated F bracket, two 10-32 stud coil terminals. 24812-04, 12V Copper contacts. 24512-10, 12V Insulated BP F bracket, two blade coil terminals. 24612-10, 12V Grounded BP F bracket, one 10-32 stud coil terminal. Rapid ship item. 44 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com solenoids & relays Intermittent Duty, 200A E4 Electronic solenoids 12V DC SPST normally open contacts. 200A make and break, 5 secs On, 5 secs Off. 300A inrush (Sealed solenoids: 200A make and break, 5 secs On, 5 secs Off. 500A inrush, maximum On time 20 secs). Allow at least 40 secs Off after maximum On time. Copper contacts. 2 Insulated. Shown: L bracket, blade terminals. 3 Electronic Solenoid 48785, Electronic Solenoid 85A 9-31V DC Fully solid-state, with no moving parts to wear out. The Electronic Solenoid stands up to over 20 million On-Off cycles. It is completely sealed, ignition protected, and withstands vibration and adverse environments. Perfect for vehicles that are always on the move. Use the Electronic Solenoid in both 12V or 24V applications... or any voltage between 9 and 31V. 4 1 * Solenoid can be used in both High Side and Low Side switching applications. * Needs only a very low control current. * Suitable for high inrush demand circuits. 2 O R BS EF O ER LE T EN E C FO E R O N LY Grounded. Shown: L bracket, blade terminal. E 1 3 24512-03, 12V Insulated BP L bracket, two 5/16" -24 studs, two blade coil terminals. 24612-03, 12V Insulated BP L bracket, two 5/16" -24 studs, two 10-32 stud coil terminals. 24712-S7, 12V Insulated, Sealed F bracket, two 1/4" -20 studs, two 8-32 stud coil terminals. Specifications: 9 - 31V DC, 85A continuous or 175A intermittent. 24612-G13, 12V Grounded BP L bracket, two 5/16" -24 studs, one 8-32 stud coil terminal. Low On resistance of .005 24712-GS7, 12V Grounded, Sealed BP F bracket, two 1/4" -20 studs, one 8-32 stud coil terminal. On/Off control voltage must be identical to the system voltage. Low control current of .02A (max) means lighter wires, smaller harnesses. Wide temperature operating range -40C to + 85C without derating. BAT + Red Black + - LOAD High side switching application BAT + LOAD Red Black + - Low side switching application Protected from transient voltage spikes or surges. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 45 E solenoids & relays MicroRelays 25A at 12V DC E5 Relays Heavy Duty & High Power Relays General purpose relays fit many vehicles. Typical applications include: lighting, starting, horn, heating and cooling. Ignition protected to SAE J1171, Section 5. Standard ISO terminal footprint for Form A (SPST), Form C changeover (SPDT) and Form 2A (SPST, 2 terminals). Relays are available sealed and unsealed (unsealed are supplied with snap-in brackets.) MicroRelays fit many vehicles and applications. They have a reduced size, but can accept a 25A load. Typical applications include: lamp control, horns, power windows, fuel pumps, fans and lifts gates. Standard terminal footprint for Form A (SPST), Form C changeover (SPDT) MicroRelays are available sealed and unsealed. Specifications: O R BS EF O ER LE T EN E C FO E R O N LY Relay Schematics are on page 100. Pull-in voltage: 7.8V maximum at 12V DC, 15.6V at 24V DC. Release voltage: 1.2V minimum at 12V DC, 2.4V at 24V DC. Temperature range: -40C to 85C. Operational life: Electrical to 100,000 cycles; Mechanical to 10 million cycles. Contact Material: Silver alloy. Dielectric strength: 500V rms between coil and contact. Insulation resistance: 100M minimum (500V DC). Vibration resistance: 10-40Hz double amplitude 1.5mm. Cole Hersee Relays are rated based on a steady state resistive load. De-rate according to the type of load: Motor load: Inrush can be 5 to 10 x steady state current. Solenoid load: Inrush can be 10 to 20 x steady state current. Incandescent lamp load: Inrush can be 10 to 15 x steady state current. Relays are also available with PCB terminals. Contact Cole Hersee. Heavy Duty Relays 40A at 12V DC Specifications: Contact rating (Resistive load) at 20C: 12V DC: Normally Open 40A, Normally Closed 30A. Specifications: MicroRelay Schematics are on page 100. Contact rating (Resistive load) at 20C: 12V DC: Normally Open 25A, Normally Closed 20A. 24V DC: Normally Open 15A, Normally Closed 10A. Contact arrangement: Available as Form A (SPST), and Form C (SPDT). Vibration resistance: 10-40Hz double amplitude 1.27mm. Pull-in voltage: 7.8V maximum at 12V DC, 15.6V at 24V DC. Release voltage: 1.2V minimum at 12V DC, 2.4V at 24V DC. Temperature range: -40C to 85C. Operational life: Electrical to 100,000 cycles. Mechanical to 10 million cycles. Contact Material: Silver alloy. Dielectric strength: 500V rms between coil and contact. Insulation resistance: 100M minimum (500V DC). 24V DC: Normally Open 20A, Normally Closed 15A. Cole Hersee Relays are rated based on a steady state resistive load. De-rate according to the type of load: Contact arrangement: Available as Form A (SPST), Form C (SPDT) and Form 2A (SPST, 2 terminals). Motor load: Inrush can be 5 to 10 x steady state current. Solenoid load: Inrush can be 10 to 20 x steady state current. Incandescent lamp load: Inrush can be 10 to 15 x steady state current. High Power Relays 70A at 12V DC MicroRelays are also available with PCB terminals: contact Cole Hersee. Specifications: Contact rating (Resistive load) at 20C: 12V DC: Normally Open 70A, Normally Closed 60A. 24V DC: Normally Open 35A, Normally Closed 30A. Contact arrangement: Available as Form A (SPST) and Form C (SPDT). Rapid ship item. 46 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com solenoids & relays Relay Part Number Structure E MicroRelay S Sealed Part Number Form. Bracket Amp. N Nothing (no sealing) MA-250012-RN A:SPST 00:None 25 12 R MA-250012-RS A:SPST 00:None 25 12 R S MA-250012-NN A:SPST 00:None 25 12 N N Volt. Suppressor Seal N R Relay 00 Without bracket* MA-150024-RS A:SPST 00:None 15 24 R S M MicroRelay 01 With snap-in bracket MA-150024-DN A:SPST 00:None 15 24 D N R A 40 01 12 R S R Resistor 15 15A at 24V DC 20 20A at 24V DC 25 25A at 12V DC 35 35A at 24V DC 40 40A at 12V DC 70 70A at 12V DC MA-150024-NN A:SPST 00:None 15 24 N N MC-250012-NN C:SPDT 00:None 25 12 N N MC-150024-RS C:SPDT 00:None 15 12 R S MC-150024-NN C:SPDT 00:None 15 24 N N D Diode N Nothing (no suppressor) Relay Sockets 12 12V DC O R BS EF O ER LE T EN E C FO E R O N LY Accepts Cole Hersee relays and standard ISO relays. Modular - sockets dovetail together. Accepts standard quick-connect terminals. Easy mount bracket. Constructed of rugged glass-filled polyamide. Temperature range -40F to 85C. 24 24V DC A Form A (SPST) C Form C (SPDT) 2 Form 2A (SPST two terminals) 99025, High Power Socket For use with Cole Hersee High Power Relays. Form A (SPST) Relay Stock Items Use with Tyco (AMP) terminals 280756 or 280755 (consult terminal manufacturers for full specs). Other configurations, and PC terminals are available. Contact Cole Hersee. Key: N: none D: diode Relay Part Number Form. Bracket RA-400112-NN BP A:SPST 01: Snap-in 40 12 N N RA-400112-RN BP A:SPST 01: Snap-in 40 12 R N A:SPST 01: Snap-in 40 12 D N S RA-400112-DN RA-400012-DS BP RA-200024-DS RC-400112-NN BP Amp. Volt. Suppressor Seal A:SPST 00:None 40 12 D A:SPST 00:None 20 24 D S C:SPDT 01: Snap-in 40 12 N N RC-400112-DN BP C:SPDT 01: Snap-in 40 12 D N RC-200124-RN BP C:SPDT 01: Snap-in 20 24 R N RC-400012-DS BP C:SPDT 00:None 40 12 D S 2:SPST 01: Snap-in 20 24 R N R2-200124-RN RA-700112-NN BP A:SPST 01: Snap-in 70 12 N N RA-700112-DN BP A:SPST 01: Snap-in 70 12 D N RC-700112-NN BP C:SPDT 01: Snap-in 70 12 N N RC-700112-RN BP C:SPDT 01: Snap-in 70 12 R N 99026, Heavy Duty Socket For use with Cole Hersee Heavy Duty Relays. Form A (SPST) or Form C (SPDT). Use with Tyco (AMP) terminals 42281 or Ark-Les 3000H112A series (consult terminal manufacturers for full specs). forward and reverse Our 24452 Forward & Reverse Relay Module combines dynamic braking with forward and reverse control, and is fully sealed. See page 64. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 47 momentary switches F 9155*, With Large Button 15/16" diameter button. 2 screw terminals with lockwashers. Mounting stem: 5/8"-32 thread, 21/32" (16.7mm) long. F1 Heavy Duty Push-Button Switches For applications to 36V DC. Off - On, Normally Off. On with button depressed, spring return to Off. Silver contacts. Chrome plated button and face nut (except where noted). Cylindrical Housing 35A at 12V, 20A at 24V DC. 9095 BP Two screw terminals. Mounting stem: 5/8"-32 thread, 21/32" (16.7mm) long. O R BS EF O ER LE T EN E C FO E R O N LY 9231, With Protected Button With recessed facenut designed to prevent accidental actuation. 2 screw terminals. Mounting stem: 5/8"-32 thread, 21/32" (16.7mm) long. 9245, With Seal and Snap-on Cap BP Same as 9095, except with O-ring seal in the mounting stem, snap-on black rubber protective cap (407-03), and black plastic button. 90030, With Plastic Button, and Screw-On Cap Two screw terminals. Mounting stem: 5/8"-32 thread, 21/32" (16.7mm) long. With screw-on black rubber protective cap 83280-03. 90036-02, With Blade Terminals Same as 9095, except with 2 blade terminals to fit Delphi (Packard) 2973407 two-way connectors, or similar. 90030-01, With Plastic Button, and Oil-Resistant Cap Same as 90030, except with brown oil-resistant cap 83280-05. 90030-04, With Plastic Button, and Red Screw-On Cap Same as 90030, except with Red screw-on protective cap 83280-02. more moms You'll find more moms (or momentary switches) in the following catalog sections: Rocker & Toggle Switches - Ignition Switches - Foot-Operated Switches - Rapid ship item. 48 BP Available in retail clamshell pack. Section C Section B Section H8 Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com momentary switches Rectangular Housing 10A at 12V DC, except where noted. 9044 Normally Off. 2 screw terminals. Mounting stem: 5/8"-32 thread, 1.06" (26.9mm) long. Gasket seal in the case. 90043, Sealed, with Rubber Cap Normally On. 10A at 24V DC, 20A at 12V DC. Two blade terminals accept 2-pole Delphi (Packard) connector 2977647 or equivalent. Mounting stem: 5/8"-32 thread, .625" (15.9mm) long. Gasket seal in the case. Steel plunger protrudes through the cap. Black rubber cap snaps into a special groove on the nut, which is deep-threaded and gives a positive seal. M-608, PVC-Coated BP Normally Off. Corrosion-resistant brass case. PVC-coated body sealed against moisture and dirt, with black rubber snap-on cap 407-03. Two 12" (304.8mm) 18AWG leads. Brass mounting stem 5/8"-32, 15/16" (23.8mm), fits panels up to 1/2" (12.7mm) thick. O R BS EF O ER LE T EN E C FO E R O N LY 9023 Normally Off. 15A resistive, 10A inductive at 12V DC, 8A resistive, 5A inductive at 24V DC. Two screw terminals. Mounting stem: 5/8"-32 thread, .87" (22.1mm) long. F 9238, With Blade Terminals Same as 9023, but with blade terminals. 9023-A*, With Silver Contacts Same as 9023, but with silver contacts, giving greater voltage range - 6-36V DC. 15A at 12V, 8A at 24V, 4A at 36V DC. 9212 Normally On. 2 blade terminals. Mounting stem: 7/16"-20 thread, 1/2" (12.7mm) long. 1/2" (12.7mm) plunger with nylon cap. Brass contacts. 9115 Normally On.Two screw terminals with lockwashers. Mounting stem: 5/8"-32, 7/8" thread (22.2mm) long. Copper contacts. online catalog Check out the Cole Hersee interactive catalog at www.colehersee.com Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 49 F momentary switches F2 Two Circuit Push-Button Switches F3 Caps for push button switches Two circuits are simultaneously energized. Flexible caps give added resistance to weather and dust. Normally Off Threaded Caps Off-On, normally Off. On with plunger depressed, spring return to Off. Rubber cap is permanently fastened to the integral mounting nut by a rolled brass bezel. The deep threaded 5/8"-32 aluminum mounting nut assures a positive seal. Durable, resilient rubber, embossed `PUSH'. Fits Cole Hersee and all other push button switches with a 5/8"-32 thread mounting stem. 9165, With Screw Terminals 10A per circuit at 12V DC. Three screw terminals with lockwashers. Mounting stem: 5/8"-32 thread, 21/32" (16.7mm) long with two steel hexnuts and facenut. 83280-03, Black BP 83280, Gray O R BS EF O ER LE T EN E C FO E R O N LY 83280-02, Red 9276*, With Blade Terminals, Silver Contacts 35A at 12V, 20A at 24V, 10A at 36V DC. Three blade terminals. Mounting stem: 5/8"-32 thread, 21/32" (16.7mm) long. Silver contacts for extra-heavy applications to 36V DC. 83280-05, Oil-Resistant For use on fuel delivery trucks. Cap is molded from resilient Hydrin which provides excellent resistance to fuel oils. Brown color. Snap-On Caps Ribs on the inside of the rubber cap engage with the switch facenut. 407-03, Black 407-01, Gray Normally On BP BP On-Off, normally On. Off with plunger depressed, spring return to On. 9211 Commonly used in school bus stepwell and door control. Four blade terminals. Mounting stem: 7/16"-20 thread. .33" (8.4mm) diameter button. 10A per circuit at 12V DC. Rapid ship item. 50 BP Available in retail clamshell pack. F4 Specialized momentary switches 9109, Normally Off. Use with Cable or Lever 10A at 12V DC. Normally Off. Pull On, spring return to Off. Brass case and mounting hardware. Two screw terminals with lockwashers. Mounting stem 1/2"-20 thread, 5/8"(15.9mm) long. No knob: shaft has 3/32" (2.4mm) hole for the attachment of a cable or lever. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com momentary switches F Horn Buttons Momentary Grounding Switch 96101, Surface Mount BP 5A at 12V DC. Two screw terminals. Black plastic button, 13/16" (20.6mm) diameter. 9059, Snap Mount 5A at 12V DC. Chrome-plated brass button with chrome-plated faceplate. One bullet terminal. Snaps into 15/16" (23.8mm) diameter hole. Self-grounding in metal panels. Contacts normally open. Contacts close (terminal to ground) with plunger depressed, spring return to open. Compact Design 5A at 12V DC, except where stated. Normally Off is Push to Mom On, spring return to Off. Normally On is Push to Mom Off, spring return to On. Toggled type is Push to On, Push to Off. 9075, Normally On Snaps into .80 - .85" (20.3 - 21.6mm) diameter hole. Fits panels .03 - .07" thick (.76 - 1.8mm). Moisture-resistant molded plastic case. Two female bullet terminals, plastic plunger 9/16" (14.3mm) long. O R BS EF O ER LE T EN E C FO E R O N LY 96100, Clamp Mount 5A at 12V DC. Same as 96101, but with clamp that allows attachment on a steering column up to 1 1/2" (38.1mm) diameter. 96102, Large Button, Clamp Mount 5A at 12V DC. Two screw terminals. Ivory plastic button 1 3/4" (44.5mm) diameter. Clamp allows attachment on a steering column up to 1 1/2" (38.1mm) diameter. Replaces: Delco 1972534, Ford B0A, B9a, B9MF, C3AZ, C5AZ, C607, FEW, OA-13713-A, Jeep 805699, Motorcraft SW-265, 395, Peterbilt 16-03030. Engine Start/Engine Stop 35A at 12V, 20A at 24V DC. Two screw terminals with lockwashers. Mounting stem 7.8"-24 thread, keyed to prevent switch from turning, fits panels .04" - .10" thick (1.0 - 2.5mm). Silver contacts. Impact-resistant molded plastic button with imprint, white on color, repels oil, water and other liquids. Diecast housing, with knurled aluminum facenut. 2 7/32"L x 1 1/8"D (50.8 x 28.6 x 3.18mm). 90047, With Black `Start' Button 90048, With Red `Stop' Button F5 Door Momentary Switches SPST Normally On Off with plunger depressed, spring return to On. Without Faceplate 9055, With 1/2" Plunger 7/16" -20 thread mounting stem, 7/16" long (11.1mm), two flats on stem for mounting in double-D hole. Two screw terminals, plated steel case. 10A at 12V DC. 90047-01, Weatherproof with `Start' Imprint Same as 90047, but with special facenut with built-in lip seal for added weather-resistance. 90048-01, Weatherproof with `Stop' Imprint Same as 90048, but with special facenut with built-in lip seal for added weather-resistance. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 51 F momentary switches 9264, with 1/2" Button End Plunger 7/16" -20 thread mounting stem, 7/16" long (11.1mm), two flats on stem for mounting in double-D hole. Two screw terminals, plated steel case. 10A at 12V DC. 9270-01, with Sealed Plunger, and Wire Leads Two .144" (3.7mm) diameter mounting holes, 1 1/2" (38.1mm) on centers. 0.70" diameter (17.8mm) plated steel case. Plunger: 0.436" long (11.1mm). Black rubber cap on plunger, and PVC coating on 8" (203.0mm) wire leads protect against moisture and dirt. 5A at 12V DC. 9264-02 Same as 9264 except with 7/8" (22.2mm) mounting stem. 10A at 12V DC. DPST Normally On Off with plunger depressed, spring return to On.For energizing two circuits simultaneously. Popular for use in school bus stepwell and door control. 10A at 12V DC O R BS EF O ER LE T EN E C FO E R O N LY 9003 1/2" -20 thread mounting stem, 1/4" long (6.4mm), two screw terminals, 13/32" plunger (7.9mm). 5A at 12V DC 9118, with Screw Terminals 7/16" -20 thread mounting stem, 7/16" (11.1mm) long, two flats on stem for mounting in double-D hole. Four screw terminals. Plunger 19/64" (7.54mm) long. 10A at 12V DC. With Faceplate 9001, with Screw Terminals Two screw terminals. Two 9/64" diameter (3.6mm) mounting holes, 1 3/8" (34.9mm) on centers. 45/64" diameter (17.9mm) plated steel case. Plunger: 7/16" long (11.1mm). 5A at 12V DC 91801, with Blade Terminals Same as 9118, except with four blade terminals. 10A at 12V DC. 9270, with Blade Terminals Similar to 9001, but with two blade terminals. 91801-01 Same as 91801, except with one insulated, one grounded circuit and three blade terminals. 10A at 12V DC. 9087, with Screw Terminals, Four Mounting Holes BP Four 3/16" diameter mounting holes, 1 3/8" and 2 1/16" on center (34.9, 51.0mm). 45/64" diameter (4.8mm) plated steel case. Plunger: 7/16" long (11.1mm). 5A at 12V DC. Rapid ship item. 52 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com momentary switches F School Bus Switches Normally Grounded Switches Designed for use in 8 light warning systems in school buses. 10A at 12V DC Self-grounding in metal panels. Contacts Open with plunger depressed, spring return to Ground. 91811, Two-Circuit Normally On - Mom Off - Mom On. Two circuits. 7/16" -28 thread mounting stem, 3/4" (19.0mm) long, flat on stem for mounting in D hole. Four screw terminals, Plunger 23/64" (9.2mm) long. Extraheavy duty. 10A at 12V DC. 91812 7/16" -20 thread mounting stem, 7/16" (11.1mm) long, two flats on stem for mounting in double-D hole. One blade terminal, plunger 33/64" (13.1mm) long. 5A at 12V DC. 9251 5/16" -18 self-tapping thread, mounting stem 1/2" (12.7mm) long. One female bullet terminal, plunger 7/16" (11.1mm) long, operates with 35oz (.99 kg) minimum pressure. 5A at 12V DC. O R BS EF O ER LE T EN E C FO E R O N LY 91804, Four-Circuit DPDT Normally On. Momentary Off. 7/16" -28 thread mounting stem, 3/4" (19.0mm) long, flat on stem for mounting in D hole. Six screw terminals, Plunger 23/64" (9.2mm) long. Extra-heavy duty. 10A at 12V DC. Single-Circuit 91800, with Stationary Off and Momentary Off Positions. 3 Positions. Normally On. Pull-out feature permits circuit to be shut off manually when the door must remain open and operation is not required. 7/16" -20 thread mounting stem, 7/16" (11.1mm) long. Two flats on stem for mounting in double-D hole. Two screw terminals. Plunger is 7/32" (5.6mm) long at On, 3/4" (19.0mm) at Off. 10A at 12V DC. Mom Off On Replaces: Chrysler 1571542, 1594751, 1688514, 1838957, GMC 4882978, 6276718, Motorcraft SW-690 (one terminal application). 91822 3/8" -24 self-tapping thread, mounting stem 7/32" (5.6mm) long. One blade terminal, plunger 5/16" long, self-adjusting to 1/4" long. Operates with 6lbs (2.7 kg) minimum pressure. 3A at 12V DC. Replaces: GMC 9665205, 9839085, 20057138. Two-Circuit Two circuits grounded simultaneously. 5A at 12V DC Off 91823 3/8" -24 thread, mounting stem 7/32" (5.6mm) long. Two blade terminals, plunger 3/16" (4.8mm) long, self-adjusting to 1/4" (6.4mm) long. Operates with 7lbs (3.2 kg) minimum pressure. 5A at 12V DC. Replaces: AMC 3631896, 3662814, Chrysler 2497590, 2889084, GMC 9852254, 20603498, Motorcraft SWG-1115. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 53 wiper & dimmer switches G With or Without Dynamic Parking G1 Electronic wiper Switches With intermittent delay feature for permanent magnet electric wiper motors. Ensures dependable control of windshield wipers on heavyduty vehicles. For 12V DC or 24V DC vehicles as noted, with or without dynamic parking, negative ground only. 4 positions: Off/ParkIntermittent Range - Low - High. Push-to-wash (two to three wipes after the knob is released). Black plastic knob with metal insert and set screw, white imprint. Diecast case 2 7/32" (56.4mm) square, 1 13/16" (46.0mm) long. 7/16 -28 thread mounting stem, .45" (11.3mm) long. Hexnut and lockwasher included. Switches conform to SAE J1455, SAE J112a and J234. Switches control most two-speed wiper motors. OFF/ PARK Microprocessor accomodates motors with or without dynamic parking. Sychronized motor motion - motors run at same speeds, and in phase. Overcurrent and short-circuit protected. 75600-01, Two Motors, 12V DC Controls two motors. One Delphi (Packard) 4-way male connector 6294544 (mates with 2977048) and one Delphi (Packard) 6-way male connector 2977042 (mates with 2977044). With round knob imprinted with SAE washer-wiper symbol. Lead and connector assembly: 5.625" (142.9mm) long. 75602-02, Two Motors, 24V DC Same as 75600-01, but 24V. ON, Long Delay 15 sec O R BS EF O ER LE T EN E C FO E R O N LY Intermittent Delay ON, Short Delay 2 sec LOW SPEED HIGH SPEED For Two Motors. Microprocessor Control Microprocessor accomodates motors with or without dynamic parking. Sychronized motor motion - motors run at same speeds, and in phase. Overcurrent and short-circuit protected. With Dynamic Parking Controls one or two motors. 75600-04, One Motor Leads, 12V DC Microprocessor design. Six color-coded wire leads, 5" (127.0mm) long. With round knob imprinted with SAE washer-wiper symbol. 75602-04, One Motor, Leads, 24V DC Microprocessor design. Same as 75600-04, except 24V. 75600*, One Motor, Delphi (Packard), 12V DC Microprocessor design. Same as 75600-04, but with Delphi (Packard) 8-way female connector 2965977 (mates with 2965972.) With round knob imprinted with SAE washer-wiper symbol. 75600-01, 12V Controls two motors. One Delphi (Packard) 4-way male connector 6294544 (mates with 2977048) and one Delphi (Packard) 6-way male connector 2977042 (mates with 2977044). With round knob imprinted with SAE washer-wiper symbol. Lead and connector assembly: 5.625" (142.9mm) long. 75602-02, 24V Same as 75600-01, but 24V. For Two Motors 75600-02, One Motor, Delphi (Packard), 12V DC Controls one motor. One Delphi (Packard) 6-way male connector 2977042 (mates with 2977044). Lead and connector assembly: 5.625" (142.9mm) long. With round knob imprinted with SAE washer-wiper symbol. Without dynamic parking. Controls one or two motors, such as Johnson electric motors (formerly United Technologies) and Sprague Devices. Lead and connector assembly 5.625" long (142.9mm). Delphi (Packard) 8-way male connector 2965972 (mates with 2965977). 75600-05, One Motor, Delphi (Packard), 12V DC Controls one motor. One Delphi (Packard) 4-way male connector 6294544 (mates with 2977048) and one Delphi (Packard) 4-way female connector 2977048 (mates with 6294544). With round knob imprinted with SAE washer-wiper symbol. Lead and connector assembly: 5.625" (142.9mm) long. 75601-02, 12V, With Knob Same as 75601-08, but with round knob imprinted with SAE washer-wiper symbol. 75601-08, 12V, Without Knob 75600-07*, One Motor, 12V DC Controls one motor. One 7-pole connector. Supplied with hexnut and lockwasher for mounting, no knob. Lead and connector assembly: 5.625" (142.9mm) long. Rapid ship item. 54 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com wiper & dimmer switches For Single Motor Controls one motor. With dynamic parking. 75600-04, 12V, With Leads Microprocessor design. Six color-coded wire leads, 5" (127.0mm) long. With round knob imprinted with SAE washer-wiper symbol. 75600*, 12V, Delphi 8-Way Connector Microprocessor design. Same as 75600-04, but with Delphi (Packard) 8-way female connector 2965977 (mates with 2965972.) With round knob imprinted with SAE washer-wiper symbol. 75600-02, 12V, Delphi 6-Way Connector One Delphi (Packard) 6-way male connector 2977042 (mates with 2977044). Lead and connector assembly: 5.625" (142.9mm) long. With round knob imprinted with SAE washer-wiper symbol. Without Dynamic Parking For use with Johnson Electric (formerly United Technologies) motors. Black plastic knob with metal insert and set screw, white imprint. Plated steel case 1 3/8" (34.9mm) diameter, 3/8" (9.5mm) long. Mounting stem 7/16" -28 thread, .38" (9.6mm) long. 75212-04, Single Motor, without Push-To-Wash 4 blade terminals. 75221-06, Single Motor, without Push-To-Wash 4 blade terminals. Internal 6A circuit breaker at 12V DC. 75221-09, Single Motor, with Push-To-Wash 5 blade terminals. Internal 6A circuit breaker at 12V DC. 75217-04, Dual Motor, without Push-To-Wash 6 blade terminals. O R BS EF O ER LE T EN E C FO E R O N LY 75600-05, 12V, Two Delphi Connectors One Delphi (Packard) 4-way male connector 6294544 (mates with 2977048) and one Delphi (Packard) 4-way female connector 2977048 (mates with 6294544). With round knob imprinted with SAE washer-wiper symbol. Lead and connector assembly: 5.625" (142.9mm) long. G 75600-07, 12V, 7-Way Connector One 7-pole connector. Supplied with hexnut and lockwasherfor mounting, no knob. Lead and connector assembly: 5.625" (142.9mm) long. 75602-04, 24V DC, With Leads Microprocessor design. Same as 75600-04, except 24V. 75226, Dual Motor, with Push-To-Wash 7 blade terminals. With Dynamic Parking For use with motors with dynamic parking, including Robert Bosch and Sprague Devices motors. Sealed construction, including O-ring on the shaft. Black plastic knob with metal insert and set screw, white imprint. Mounting stem 7/16" -28 thread, .45" (11.4mm) long. Diecast case 1 5/8" (41.3mm) diameter. 75228-03, Single Motor, Push-To-Wash 6 blade terminals. Without Dynamic Parking Controls one or two motors. 12V DC. Includes motors by Johnson Electric (formerly United Technologies) and Sprague Devices. Lead and connector assembly: 5.625" (142.9mm) long. Delphi (Packard) 8-way male connector 2965972 (mates with 2965977). 75601-02, With Knob Same as 75601-08, except with round knob imprinted with SAE washer-wiper symbol. 75601-08, Without Knob Includes hexnut and lockwasher for mounting. 75228-04, Single Motor, without Push-To-Wash 5 blade terminals. 75236, Dual Motor, with Push-To-Wash 8 blade terminals. Knobs 81298-02, Wiper Symbol Accepts 3/16" (4.9mm) diameter shaft. Imprinted with windshield wiper symbol. G2 Electric two-speed wiper switches For Permanent Magnet Electric Wiper Motors 81298-34, Wiper-Washer Symbol Accepts 1/4" (6.4mm) diameter shaft. Imprinted with windshield wiper symbol. For 12V and 24V DC, except where noted. For use with heavy-duty permanent magnet electric wiper motors. 3 positions: Off/Park - Low - High. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 55 G wiper & dimmer switches 74603 6, Amps, AMP Connectors Two wires (load, battery) 2" (50.8mm) long, with two AMP connectors (load 480054-3, battery 480053-3). Duty cycle: 1 - 99%. G3 Electronic Dimmer Switches 74600-02, 4 Amps, Delphi (Packard) Connector Three wires (load, battery, ground) with Delphi (Packard) connector 2984378 on 3" (76.2mm) leads. Duty cycle: 0 - 100%. 74601-01, 7 Amps BP Two wires (load and battery) 1 25/32" (45.2mm) long. Duty cycle: 1 - 99%. H O R BS EF O ER LE T EN E C FO E R O N LY 74600-09, 4 Amps, Leads Same as 74600-02, except with two wires, no connector. Two wires (load, battery) 1 25/32" (45.3mm) long. Duty cycle:1 - 99%. push-pull, rotary & headlamp 50070, Silver Contacts, Blade Terminals Same as 5011, except with two blade terminals. H1 one circuit push-pull switches SPST, Off-On. Universal application. Mounting hardware included. 5053, Glass Fuse, Chrome Knob Steel mounting stem 1/2"-20 thread, 5/8" (15.9mm) long. Chrome-plated knob. Two screw terminals, plated steel case. 20A SFE fuse. Normally Off, 10A Heavy duty, 10A at 12V DC, 6-36V. 5007, Screw Terminals BP Aluminum mounting stem 3/8"-32 thread, 5/8" (15.9mm) long. Tan plastic knob with 10-32 threaded metal insert. Two screw terminals, plated steel case. 5067, Glass Fuse, Plastic Knob Same as 5053, except with ivory plastic knob. 50031*, Blade Terminals Same as 5007, except with two blade terminals and ivory plastic knob. 50077, Sealed Case O-ring in stem, and gasketsealed terminal insulator. Brass mounting stem 7/16"-28 thread, 5/16" (7.9mm) long. Black plastic knob with 10-32 threaded metal insert. Two screw terminals, zinc case. 5011, Screw Terminals BP Steel mounting stem 1/2"-20 thread, 5/8" (15.9mm) long. Chrome-plated knob. Two screw terminals, plated steel case. Rapid ship item. 56 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com push-pull, rotary & headlamp switches M-606, PVC-Coated BP SPST Off-On, normally Off. Brass housing, plasticized. Two insulated copper wire leads, 12" (304.8mm) long. Chrome-plated brass knob, 10-32 thread. H 5050, Extra Heavy Duty with Circuit Breaker 20A total, 6-36V. With 30A circuit breaker (available with other values). Silver contacts. Plated steel mounting stem 1/2"-20 thread, 5/8" (15.9mm) long. Black plastic knob 10-32 thread with set screw, imprinted 'Lights'. Two screw and one stud terminals, plated steel case Normally Off, 20A Extra heavy duty, 20A at 12V DC, 6-36V. Common Circuits 50001, Black Knob Silver-laminated contacts. Brass mounting stem 1/2"-20 thread, 5/8" (15.9mm) long. Black plastic knob with 10-32 threaded metal insert. Two screw terminals, plated steel case. Switches energize two independent circuits alternately from a common feed. SPDT, Off-On-On Off - On circuit 1 - On circuit 2. 6-36V. O R BS EF O ER LE T EN E C FO E R O N LY 5066, Screw Terminals 10A at 12V DC. Three screw terminals. Steel mounting stem 1/2"-20 thread, 5/8" (15.9mm) long, and integral chrome-plated knob. Plated steel case. 50002, Metal Knob Same as 50001, except with chrome-plated brass integral knob. 50066, Sealed Same as 50001, except with O-ring seal in stem, and gasketsealed terminal insulator. 50082, Blade Terminals 8A at 12V DC. Three blade terminals. Steel mounting stem 1/2"-20 thread, 5/8" (15.9mm) long, and integral chrome-plated knob. Plated steel case. Normally On 50046 Heavy Duty: 10A at 12V DC, 6-36V. Aluminum mounting stem 3/8"-32 thread, 5/8" (15.9mm) long. Black plastic knob with 10-32 threaded metal insert. Two screw terminals, plated steel case. H2 two circuit push-pull switches H3 specialized switches 7014, Heater Switch, Four Positions Off-Low-Med-Hi. 12V DC. Coil resistance 3 Ohms. Two screw terminals. Ivory plastic knob, imprinted "Heater" in gold lettering, with 10-32 threaded metal insert. Plated steel case 3 5/64"L x 1 5/64"W x 3/4"H (78.2 x 27.4 x 19.1mm). 7/16" -28 thread mounting stem, .26" (6.7mm) long. Independent Circuits Switches energize two independent circuits simultaneously. 5027, SPST Extra Heavy Duty, Off-On, Normally Off 18A at 12V DC, 6-36V. Three screw terminals and ivory plastic knob, imprinted 'Lights', with 10-32 thread and set screw. 7019, Heater-Defroster Switch Three positions: Off - Low - High. 10A at 12V DC. Two screw terminals. Without knob, shaft is 10-32. Three female bullet terminals. Case 1.625" x .85" x .635" (41.3 x 21.6 x 15.9mm). 7/16" -28 thread mounting stem, .34" (8.6mm) long. Replaces: Ford FAA-18578-A. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 57 H push-pull, rotary & headlamp switches 50071, Heater Switch Two-circuit, SP Off - On (low speed) - On (high speed). Energizes two circuits alternately from a common feed. Heavy-duty: 10A at 12V DC, 6-36V DC. Plated steel housing and mounting stem, 1/2" -20 thread, 1/4" (6.4mm) long. Integral chrome-plated brass knob. Three female bullet terminals. Mounting hardware included. 40103, Drive Screw Assembly Screw assembly operates 9283 (Terminal block limit switch). 68028, Heater Switch, Three Positions Off-Hi-Lo. 12V DC. Coil resistance 3 Ohms. Two screw terminals. Ivory plastic knob, imprinted "Heater" in gold lettering, with 10-32 threaded metal insert. Plated steel case 1 13/16"W x 1 19/32" x 1/2"H (46.0 x 40.5 x 12.7mm). 7/16" -28 thread mounting stem, 5/16" (15.8mm) long. 50203, Magneto Switch, Out-Run In-Off (magneto terminal grounded) out-Run (magneto terminal open). 10A at 12V DC, 6-36V DC. Integral nickel-plated knob. One screw terminal. Plated steel housing. Aluminum mounting stem 3/8" -32 thread, 5/8" long (15.9mm). O R BS EF O ER LE T EN E C FO E R O N LY Replaces: Chevrolet & GMC 2279003, Diamond T/Reo 9920-H, 3563-D5, Eaton 32364, Ford 8QH-4086-A, International 79037-R11, White 716925. H4 Push-pull headlamp switches 50036, Two-Speed Axle Switch Two-circuit, On-On.12V DC. For mounting on gear shift lever with a clamp (not supplied). Red plastic knob, 1 1/4" (31.8mm) diameter. Three female bullet terminals. Zinc case with protective rubber boot. For use with 9283 and 40102. 3-Position Three knob pull positions: In - Mid - Out. In = Headlamps Off; Mid = Parking Lights and Tail Lights On; Out = Headlights and Tail Lights On Replaces: Diamond T/Reo 9935-H, 319305, Dodge 1390517, Eaton 32861, Ford 8QH-4078, SW-1535, GMC 2274282, International 79348-R91, Mack IMR-201, White 716913. 9283, Terminal Block Limit Switch Controls Eaton two-speed axle shift. Use with 50036. Mounts in axle shift motor housing. Heavy plastic insulator base, two 8-32 studs, 3/4"(19.1mm) long and two 8-32 studs 7/32" (5.6mm) long. 7124, With Black Knob `Lights' Four screw terminals, plated steel case, mounting stem with 7/16"-28 thread. 15A per circuit at 12V DC. Replaces: Chevrolet 2279014, 3854312, Diamond T/Reo 9913-H, 356005, Dodge 1390517, 1508375, 1508404, Eaton 32382, 32414, 62252, Ford B2Q-4107-A, SW-1356, GMC 2279002, International 79050-R91, White 716920. 72100, With Black Knob `Lights' O-ring seal in mounting stem, gasket seal at terminal insulator. Four screw terminals, diecast case, silver contacts, mounting stem with 7/16"-28 thread. 20A per circuit at 12V DC. 40102, Connector & Cable Assembly Wire harness connects 9283 and 50036. Replaces: Eaton 38810, Ford FAB-14668-B. Rapid ship item. 58 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com push-pull, rotary & headlamp switches 7152, With Ivory Knob `Lights' Four screw terminals, plated steel case, silver contacts, mounting stem with 3/8"-24 thread. 15A per circuit at 12V DC. 72101, With Breaker With 30A at 12V circuit breaker, black knob imprinted `Lights'. O-ring seal in mounting stem and gasket seal at terminal insulator. Three screw terminals, diecast case, silver contacts, mounting stem with 7/16"-28 thread. 7127, With Fuse With 20A at 12V glass fuse, black knob imprinted `Lights'. Four screw terminals, plated steel case, mounting stem with 7/16"-28 thread. With Dimmer These switches have Headlamp/Parking Lights/Tail Lights functions as noted above, plus rotary dimmer functions for panel/dome lamps. 71092-02, 4.5 Ohm, With Internal 15A Breaker In = All lights Off, except dome light on rotary dimmer. Mid = Parking lights & rear lights On; panel lights & dome light on rotary dimmer. Out = Headlights & rear lights On; panel lights & dome light on rotary dimmer. 4.5 Ohm Dimmer, 15A at 12V internal Circuit Breaker. With black knob imprinted with SAE headlamp symbol. Eight blade terminals accept Delphi (Packard) connector 2977645 or 2984169. Plated steel case. Mounting stem 7/16"-28 thread. Terminal connections: 1 to battery +; 2 to panel lights; 3 to rear lights; 4 to rear lights; 5 to battery +; 6 to headlights; 7 to parking lights; A to dome light. Connect frame ground terminal to ground. O R BS EF O ER LE T EN E C FO E R O N LY 7157, With Breaker With 30A at 12V circuit breaker, ivory knob imprinted `Lights'. Three screw terminals, plated steel case, silver contacts, mounting stem with 7/16"-28 thread. H 71092 Same as 71092-02, but without knob and shaft. 7178, 3.75 Ohm, With 30A Breaker Rotation of knob dims panel lights in Mid and Out knob positions. 3.75 Ohm Dimmer, 30A at 12V Circuit Breaker. With black knob imprinted `Lights'. Four screw terminals. Plated steel case. Mounting stem 3/8"-24 thread. 71016, 11 Ohm, With 20A Breaker Rotation of knob dims panel lights in Mid and Out knob positions. 11 Ohm Dimmer, 20A at 12V Circuit Breaker. With tan knob imprinted `Lights'. Four screw terminals. Plated steel case. Mounting stem 3/8"-24 thread. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 59 H push-pull, rotary & headlamp switches 71042, 7 Ohm Rotation of knob dims panel lights in Mid and Out knob positions. 7.0 Ohm Dimmer. With ivory knob imprinted `Lights'. Three single and three double blade terminals. Plated steel case. Mounting stem 3/8"-24 thread. H5 rotary headlamp switches 72079-01, With Knob With black knob imprinted with SAE headlamp symbol. Silver contacts. Five screw terminals. Plated steel case. Mounting stem 5/8"-32 thread. With O-ring seal in the mounting stem. 20A per circuit at 12V DC. Off Hazard Hazard, Headlamps & Dash Lamps, Tail Lights Headlamps & Dash Lamps, Working Lights 4-Position Headlamp and Worklight Switches 72023-01, With Short Lever With lever. Four screw terminals. Plated steel case. C1short Lightdiecast Switch Diagram Mounting stem 5/8"-32 thread. With O-ring seal in the mounting stem. 20A per circuit at 12V DC. O R BS EF O ER LE T EN E C FO E R O N LY Four knob pull positions: In - Mid1 - Mid2 - Out. 7112, Headlamp Switch Five screw terminals. Plated steel case. Mounting stem 3/8"-24 thread. With tan knob imprinted `Lights'. 10A at 12V DC. Off Headlamps Headlamps, Auxiliary Lights Headlamps, Auxiliary Lights, Tail Lights 24052*, Illuminated with 'Fog Light' Imprint Illuminated tan knob with 'Fog Light' imprint. Three screw C2 Light Switch Diagram terminals. Plated steel case. Mounting stem 5/8"-32 thread. 20A fuse and No. 53 bulb supplied. 71033-02*, Work Light Switch Three blade terminals. Plated steel case. Mounting stem 7/16"-28 thread. With O-ring seal at the mounting stem. With black knob imprinted with SAE work light symbol. Off On C5 Light Switch Diagram H6 Universal rotary switches In a full range of styles and circuitries for lighting, ignition and similar applications. 2-Position Lever actuator. Two screw terminals. Plated steel case. 9500, 10A with Compact Case 10A at 12V DC. Mounting stem 1/2"-20 thread. Off On C5 Light Switch Diagram Rapid ship item. 60 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com push-pull, rotary & headlamp switches 3-Position H H7 rotary temperature & rheostat switches On1 - Off - On2. Three screw terminals. Plated steel case. 24054, 10A 10A at 12V DC. Lever actuator. Mounting stem 1/2"-20 thread. Rheostat Switches For 12V DC systems. Ceramic insulator with embedded coil for effective heat dissipation. 7/16" -28 thread mounting stem, 15/32" (11.9mm) long. Plated steel case, 1.32" (33.5mm) diameter, .88" (22.4mm) long. Black plastic knob with metal insert and set screw. Off On On Battery & Left Battery & Right Dim/Low Bright, High Off Various Switch Diagram 2I3Screw Terminals 7493, 8 Ohm With black knob O R BS EF O ER LE T EN E C FO E R O N LY C7 Light Switch Diagram 75705-01, 10A Momentary 10A at 12V DC. Mom On1 - Off - Mom On2, spring return to Off from both positions. Key actuator with coded tumbler lock. Mounting stem 13/16"-24 thread. Internal O-ring seal. 7493-07, 8 Ohm, Imprinted With black knob imprinted "Panel Lamps" Off Mom. On Mom. On 2 Blade Terminals 7496, 8 Ohm With black knob D13 Ignition Switch Diagram 90005-03, Reversing Switch For forward-reverse operation of a motor, to give a motion such as Up/Down, Left/Right, In/Out, Rotate/Counter-rotate. Suitable for control of tailgates, winches, windlasses, snowplows and other applications. DPDT. Spring return to Off from both On positions. Four screw terminals. Plated steel case. 15A at 12V DC. Key actuator with coded tumbler lock. O-ring seal in stem. Mounting stem 13/16"-24 thread. Off On On Reverse A&D B&C Forward A&C B&D Both positions spring return to OFF position 7496-04, 8 Ohm, Imprinted With black knob imprinted "Panel Lamps" Heater-Defroster Switches Four positions: Off-High-Medium-Low. 12V DC 3 Ohms or 24V DC 6 Ohms. Two screw terminals. Coil embedded in ceramic insulator for effective heat dissipation. Connections are welded to the resistance coil. Plastic round/bar knob with metal insert and set screw. Mount through a 5/8" hole (15.9mm) or with an optional bracket. 68362, 12V 68363, 24V 75712-04 Reversing Switch Four screw terminals. Silver-laminated contacts. Off Off On Reverse A1 & B1 A2 & B2 Forward A1 & B2 A2 & B1 Both positions spring return to OFF position Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 61 H push-pull, rotary & headlamp switches H8 foot-operated switches Headlamp Dimmer Switches SPDT On - On. Depress-release for low beam, depress-release for high beam. Corrosion-resistant diecast metal housings, moisture-repellent insulators. Also available: 7794* Column-mounted Dimmer Switch. SPDT On-On. Three blade terminals. Replaces: Delco 1997045, 7838234, D-812. 7769, With Three Screw Terminals 27/32" (21.4mm) diameter stem. Three 1/4" -20 tapped mounting holes, 3/4" and 1 3/4" (19.0 and 44.4mm) on centers. Replaces: Delco 465A-Z, 471P-Z, 1997002, 1997008, 1997009, 199870014, D-805, U-802, Ford 81A, 11A13532, Mack 1MR-234. On-Floorboard Mounting Through-Floorboard Mounting 7702 Two 7/32" (5.6mm) diameter mounting holes,1 5/8" (41.3mm) on centers. Three blade terminals. 7700, With Three Wire Terminals PVC-coated case and leads gives added protection.Three 16AWG leads 5.75" (146.1mm) long. 27/32" (21.4mm) diameter stem. Three 1/4" -20 tapped mounting holes, 1 3/4" and 1 3/4" on centers (19.1 and 44.5mm). O R BS EF O ER LE T EN E C FO E R O N LY Replaces: Delco U803, Ford C0TF, C0TZ-13A024A, Motorcraft SW-263. 7776 Two 7/32" (5.6mm) diameter mounting holes,1 5/8" (41.3mm) on centers. Three blade terminals. Replaces: AMC 3156124, 3160926, Chrysler 1841895, 1881938, 2097628, 2291202, 3488882, CH-247, Delco U-801, Ford B9A-13532-A. 7786, With Three Screw Terminals 1 1/16" (27.0mm) diameter stem. Three 1/4" -20 tapped mounting holes, 3/4" and 1 3/4" (19.0 and 44.4mm) on centers. Replaces: Delco 1997014, D-805. 7762 Two 9/32" (7.1mm) diameter mounting holes,1 3/4" (44.4mm) on centers. Three blade terminals. Replaces: AMC 5457282, Delco 1997028, 1997031, 1997035, 1997037, 1997040, 1997043, D-803, D-804, D-808, D-809, D-810, GMC 5834446, 578005, 1539288. 7787, With Three Screw Terminals 7/8" (22.2mm) diameter stem. Two 1/4" -20 tapped mounting holes, 1 3/4" (44.4mm) on centers. Replaces: AMC 803870, 811681, Chrysler 1689512, Delco A-800, Ford A8AZ-13A024A, 7RA, 8A-13532, Motorcraft SW-256, 260. rotary dimmers See page 56. Rapid ship item. 62 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com push-pull, rotary & headlamp switches 30156, Connector Fits Cole Hersee switches 7702 and 7776. Ford trucks 60-87, Dodge trucks 59-86. Starter Switches Off-On, normally Off. Depress to On, spring return to Off. 9060, Through-Floorboard Mounting Two stud terminals, 5/16" -24 thread with hexnuts and lockwashers. 30155, Connector Fits Cole Hersee switch 7762. Plunger is 1.83" (46.5mm) long. Two 9/32" (7.2mm) diameter mounting holes, 1 3/4" (44.5mm) on centers. Trucks: Autocar 68-80, Chevrolet 61-86, GMC 69-86, International 61-80, Freightliner 63-67, 72-80, Kenworth 65-67, 72-74, 77-80. Replaces: Autolite SW-40001 (15-47), 15-50, 401A, 4002, 4005, 4010, 4015 (15-51), Delco D900 (405C). 9183, Through-Floorboard Mounting, Short Stem Two stud terminals, 5/16" -24 thread with hexnuts and lockwashers. O R BS EF O ER LE T EN E C FO E R O N LY Turn Switches H Through-floorboard mounting. Depress to On, spring return to Off. Two switches are needed for left and right turn signals. 7785, Sealed, With Wire Leads 7/8" (22.2mm) diameter stem. Three 1/4" -20 tapped mounting holes, 3/4" and 1 3/4" (19.0 and 44.4mm) on centers. Plastic-coated, providing protection against moisture, dust and roadsplash. 7792, Sealed, With Screw Terminals 7/8" diameter stem. Three 1/4" -20 tapped mounting holes, 3/4" and 1 3/4" (19.0 and 44.4mm) on centers. Plastic-coated, providing protection against moisture, dust and roadsplash. Plunger is 1" (25.4mm) long. Two 9/32" (7.2mm) diameter mounting holes, 1 3/4" (44.5mm) on centers. Replaces: Autolite SW-4012 (15-49), Delco 1996478. brackets & busbars Find these accessories for circuit breakers on pages 67 & 68. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 63 specialized modules I 24452 Forward & Reverse Module Series 48800 Timer/Dimmer Modules Ideal for vehicle lift or tarp operations, but has many other applications such as hoists, cherrypickers, tailgates, winches, snowplows, intake/exhaust fans, vehicle outriggers... anywhere an up/down, in/out, clockwise/counterclockwise control is needed. Dynamic braking stops the motor when the switch returns to Off. Automatically reverses the direction of the motor when the appropriate control circuit is energized. Three general purpose modules have many applications for controlling motors or lighting. Modules consist of a microprocessor-based timer, driving a solid-state solenoid type output. Users can select from a range of settings by selectively cutting the jumper wires. The actuator of the module can be a manual or automatic switch. See wiring diagram on page 99. 48810-01, Delay Timer BP Suitable for control of exhaust fans or lighting. User-selectable options: 2,4,6 or 8 minutes delay. O R BS EF O ER LE T EN E C FO E R O N LY Carries a heavy load current: 70A at 12V DC intermittent, max On time 5 mins, Off time 3 mins; 50A at 12V DC continuous. Fully sealed to IP-67 - can withstand harsh environments. Low-profile module: 2.91" x 3.51" x 1.86"H (73.9 x 91.7 x 47.2mm). Protective cover 97297 is also available. 48811-01, Stepping Dimmer BP Suitable for control of cab or cabin lights. Repeated actuation of the control switch cycles the lights through the selected lighting intensities. Holding of the momentary switch for 3 seconds turns lights off, without dimming stages. Four user-selectable dimmer stepping options. 48600 Daytime Running Light Module 48812-01, Intermittent Timer BP Suitable for many applications where timed On-Off cycles are needed. Four user-selectable On-Off cycles. Automatically turns on low-beam headlights when the ignition is turned on (after a 10 second delay, thus reducing the initial starting load. Activated when the parking brake is released; deactivated when the parking brake is set (with ignition On).Deactivates when high beams are flashed for signaling. Completely solid-state construction. Supplied with 15A mini-fuse ATM98107-15. 48000 Trailer Tail Light Converter Extends the life of the headlights, because (for daytime running) they are powered at 75% of the high-beam intensity. For two or four headlamp systems. For use with 12V DC negative ground systems only. Using the Converter, towing vehicles with four lighting circuits (left stop, left turn, right stop, right turn) can properly operate trailers with two lighting circuits (left stop and turn, right stop and turn). Solid state circuitry provides high reliability and is embedded, giving complete protection against moisture and vibration. Color-coded18AWG wire leads are 24" (607.6mm) long for towing vehicle connections, 36" (914.4mm) long for attachment to trailer connector. Complies with FMVSS 108 for headlamp intensity. CMVSS-108 and CAN/CSA D-603-88, type 2. Six 28" (711mm) long wire leads, six 30223 Quick Tap wire splicers (see pages 70 & 71), and two self-tapping mounting screws. Also available without splicers and screws: order part number 48600-01. Rapid ship item. 64 BP Available in retail clamshell pack. Permits a towing vehicle with two lighting circuits for each side to operate lights on a trailer with a single circuit each side. Eliminates the need to rewire the trailer, or to add additional lights. US laws require stoplights, turn signals and taillights on trailers. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com circuit protection & wiring accessories J1 circuit breakers Circuit breakers and fuses are a cost-effective solution to protecting wiring, equipment and subsystems. While fuses are a one-time, disposable solution, circuit breakers can be re-used after overload. Part number suffixes indicate the amperage. eg: 30409-15 is a 15 ampere Type I ATC/ATO breaker. J 30408, Navistar Truck Type II, fits Navistar breaker blocks. Available in: 10, 15, 20, 25, 30, 35A and 20, 30A. Order Nos. 30408-30 or 30408-30BP etc. 1.08" (27.4mm) 0.92" (23.3mm) Plug-In Style, 12V 1.25" (31.8mm) ATC/ATO Breakers Conform to SAE J553. Replacement for ATC or ATO fuses. Color-coded housings with rating marked on the top: 10A red, 15A blue, 20A yellow, 25A silver, 30A green Stud or Blade Style Conform to SAE J553. Plated steel or rugged plastic cases with or without bracket. Metal breakers without brackets snap 0.66" securely into steel brackets (16.7mm) (Series 30090) or attach with 0.78" (19.8mm) the stud to nylon brackets (Series 87128), see page 66. Studs are 10-32, two blade types are .250" (6.4mm) wide. Breaker and bracket dimensions shown are similar on all breakers in this section. 0.68" (17.3mm) O R BS EF O ER LE T EN E C FO E R O N LY 30409, Type I Terminals are grooved so that they can be easily snapped off with pliers to fit the electrical blocks of different vehicles. Available in: 10, 15, 20, 25, 30A and 10, 15, 20, 25, 30A BP . All items are . Order Nos. 30409-30 or 30409-30BP etc. 0.50" (12.7mm) Use as is (long terminals) for Kenworth trucks. Use with one segment snapped off each terminal for: Dodge trucks, Ford heavy trucks, Navistar trucks. Use with two segments snapped off (short terminals) for Ford pickup trucks. 0.625" (15.9mm) 1.25" (31.8mm) 1.56" (39.6mm) 2.00" (50.8mm) 24V with Studs, Steel Case 30171, Type I Available in: 10, 15, 20, 30A. Order Nos. 30171-30 etc. Long terminals, as supplied One segment snapped off Two segments snapped off Special Applications 30403, Mack Truck Type II, fits Mack Truck breaker blocks. Available in: 15, 20, 25, 30A. Order Nos. 30403-30 etc. 1.00" (25.4mm) 12V with Studs, Steel Case 0.92" (23.3mm) 1.25" (31.8mm) 30172, Type I, with Bracket Available in: 10,* 15, 20, 30A. Order Nos. 30172-30 etc. 0.50" (12.7mm) 30055, Type I, with bracket Available in: 6, 8, 10, 15, 20, 25, 30, 40, 50A and 10, 15, 20, 30, 40, 50A BP . Items 10, 15, 20, 25, 30, 40, 50A are . Order Nos. 30055-50 or 30055-50BP etc. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 65 J circuit protection & wiring accessories PVC Coated, Type I 30056, Type I Available in: 6, 8, 10, 15, 20, 25, 30, 40, 50A and 15, 20, 30, 40A BP . Items 10, 15, 20, 25, 30A are . Order Nos. 30056-40 or 30056-40BP etc. With PVC coated leads and body for added weather protection. Steel case. 10" (254.0mm) wire loop is readily cut to form two leads for splicing into the circuit. Wire is color-coded: 10A green 16AWG, 15A yellow 16AWG, 20A black 14AWG, 25A white 14AWG, 30A red 12AWG, 40A brown 12AWG. 12V DC. 30128, Type I, With Cross-Bracket Available in: 6*, 8*, 10, 15, 20, 25, 30, 40A. Order Nos. 30128-40 etc. 0.68" 30063 Available in: 10, 15*, 20, 25*, 30, 40A*. Order Nos. 30063-40 etc. (17.3mm) 0.84" (21.3mm) 0.625" (15.9mm) 1.56" (39.6mm) 1.31" (33.3mm) O R BS EF O ER LE T EN E C FO E R O N LY 2.00" (50.8mm) 24V with Studs, Plastic Case 30062, With Bracket. 2.0" (50.8mm) bracket has two mounting holes 1.56" (39.6mm) on centers. Available in: 15*, 20, 30A. Order Nos. 30062-30 etc. 30407, Type III, With Cross-Bracket Available in: 15, 20, 25*, 30, 40, 50A. Order Nos. 30407-50 etc . 12V with Blades Steel case 30401, Type I Available in: 4*, 6, 8*, 10, 15, 20A. Order Nos. 30401-20 etc. Double Breaker Assemblies 12V, Type I. For high amp applications. 3088 2.0" (50.8mm) bracket has two mounting holes 1.56" (39.6mm) on centers. 30402, With Bracket Available in: 4, 6, 15, 20A. Order Nos. 30402-20 etc. Available in: 50, 60, 80A. Order Nos. 3088-50, 30088-60, 3088-80. 30507, Sealed Same as 3088, but stud insulator is sealed. Available in: 60 and 80A. Order Nos. 30507-60 or 30507-80. 30404, Blade & Stud Available in: 20 and 30A. Order Nos. 30404-30 etc. Rapid ship item. 66 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com circuit protection & wiring accessories Glass Fuse Style, 12V DC 30410, Type II Breaker replaces 3AG (AGC) and SFE glass fuses: snaps into standard clips on Cole Hersee fuse blocks. See pages 67 & 68. Available in 10, 15, 20, 25, 30, 40A. Order Nos. 30410-40 etc. 10A replaces Ford DOHB-14526-A, 15A DOVB-14526-A, 20A DOVB-14526-B, 25A DOHB-14526-B, 30A DOVB-14526-C. J Breaker Mounting Brackets - Nylon For use with Cole Hersee 30056 series and 30137 series breakers. Durable, lightweight molded nylon. Breakers mount securely using stud and hexnut. Mounting holes .280" x .440" (7.1 x 11.2mm). Slots are .910" (23.1mm) on centers, and .210" (5.3mm) wide. 87128-4, 4-Gang 5.69" long (114.5mm), mounting holes 4.89" (124.2mm) on centers. 87128-5*, 5-Gang 6.60" long (167.6mm), mounting holes 5.80" (147.3mm) on centers. 87128-6, 6-Gang 7.51" long (190.8mm), mounting holes 6.71" (170.4mm) on centers. O R BS EF O ER LE T EN E C FO E R O N LY J2 Breaker accessories 87128-7*, 7-Gang 8.42" long (213.9mm), mounting holes 7.62" (193.5mm) on centers. Breaker Mounting Brackets - Steel For all steel case breakers without a bracket. Breakers snap into position, engaging with dimples in the case of the breaker. Heavy gauge steel. Brackets up to 12-gang are available. Contact Cole Hersee. 30090-2, 2-Gang .81" x 1.29" (122.2 x 32.8mm). Mounting hole 4.00" (101.6mm) on centers. 87128-8, 8-Gang 9.33" long (237.0mm), mounting holes 8.53" (216.7mm) on centers. 87128-9*, 9-Gang 10.24" long (260.1mm), mounting holes 9.44" (239.8mm) on centers. 30090-3, 3-Gang 5.71" x 1.29" (145.0 x 32.8mm). Mounting hole 4.90" (124.5mm) on centers. 87128-10, 10-Gang 11.15" long (233.2mm), mounting holes 10.35" (262.9mm) on centers. 30090-4, 4-Gang 6.62" x 1.29" (160.1 x 32.8mm). Mounting hole 5.81" (147.6mm) on centers. 87128-12*, 12-Gang 12.97" long (329.4mm), mounting holes 11.26" (268.0mm) on centers. 30090-6, 6-Gang 8.43" x 1.29" (214.1 x 32.8mm). Mounting hole 7.62" (193.5mm) on centers. 87128-13*, 13-Gang 13.88" long (352.6mm), mounting holes 13.08" (332.2mm) on centers. 30090-7*, 7-Gang 9.34" x 1.29" (237.2 x 32.8mm). Mounting hole 8.53" (216.7mm) on centers. 30090-8, 8-Gang 10.25" x 1.29" (260.4 x 32.8mm). Mounting hole 9.43" (239.5mm) on centers. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 67 J circuit protection & wiring accessories Copper Busbars 46377-8, 8-Gang Length: 3.09" (78.5mm). Mounting holes 1.25" (31.8mm) on centers. For connecting circuit breakers to provide higher amperage ratings. Recommended for use with nylon mounting brackets 87128. Slots are .910" on centers. Slot width: .210" (5.3mm). Width of bar: .560" (14.2mm). 46377-10, 10-Gang BP Length: 3.72" (94.5mm). Mounting holes 1.875" (47.6mm) on centers. 86126-2, 2-Gang 1.41" L (35.81mm). 86126-3*, 3-Gang 2.32" L (58.4mm). 46377-12, 12-Gang Length: 4.34" (110.0mm). Mounting holes 2.5" (63.5mm) on centers. 86126-4, 4-Gang 3.23" L (82.1mm). 46377-14, 14-Gang Length: 4.97" (126.2mm). Mounting holes 3.125" (79.4mm) on centers. 86126-5*, 5-Gang 4.14" L (105.2mm). 46377-18, 18-Gang Length: 6.22" (158.0mm). Mounting holes 4.375" (111.1mm) on centers. O R BS EF O ER LE T EN E C FO E R O N LY 86126-6, 6-Gang 5.05" L (128.3mm). 86126-8, 8-Gang 6.87" L (174.5mm). Blocks for Glass Fuses and 30410 Breakers 86126-9, 9-Gang 7.78" L (197.6mm). For SFE 20A or 3AG (AGC) fuses, and 30410 circuit breakers (see page 66). 86126-10*, 10-Gang 8.69" L (220.7mm). 86126-12, 12-Gang 10.51" L (267.0mm). J3 blocks & Busbars For Plug-In Breakers & Fuses For ATC and ATO fuses and circuit breakers. Fuse/breaker contacts are recessed for safety. Recessed area in the center of the block accepts a label. Electrical ratings: 25A maximum per circuit at 12V to 24V DC. 150A maximum total for the block at 12V DC. For 24V DC applications use only ATC or ATO fuses. Common Hot Feed. Black thermoplastic block. Blade terminals are .25" wide (6.4mm). Stud terminal is 10-32 with hexnut, flat washer and lockwasher. Four .218" (5.5mm) diameter mounting holes take #10 screws. Size: 3.375" wide x .812" high (85.7 x 20.6mm). Mounting holes 1.06" (27.0mm) on centers, widthwise. 46377-6, 6-Gang BP Length: 2.47" (62.7mm). Mounting holes .625" (15.9mm) on centers. 68 BP Available in retail clamshell pack. 4652*, Extra Heavy Duty Fuse Block for SAG (AGU) Fuses For SAG (AGU) fuses 13/32" diameter x 1 1/2" long (10.3 x 38.1mm), rated up to 60A. Screw terminals, phosphor-bronze fuse clips. Molded plastic base with two 3/16" (4.8mm) mounting holes, .812" (20.6mm) on centers. M-674, Combination Fuse Block & Terminal Block For SFE 20A or 3AG (AGC) fuses. Common hot feed to four independently-fused circuits, and common ground strip for four circuits. Solid brass busbars, terminals and terminal screws. Nickel-plated phosphor-bronze fuse clips. Two eyelet holes for mounting with 3/16" (4.8mm) screws, 2.25" (57.2mm) on centers. 3 1/2"L x 2 3/4"W x 25/32"H (88.2 x 69.8 x 19.8mm). For more information, request sheet D-601. Rapid ship item. 4766, Common Hot Feed with Blade Terminals 6-gang. Blade terminals on one side of the fuse clip. 5 3/4"L x 1 7/8"W x 23/32"H (146.6 x 47.6 x 18.3mm). Brass terminal screws with lockwashers. Solid brass busbar. Two mounting holes 11/16" (4.3mm) diameter, 3.75" (95.3mm) on centers. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com circuit protection & wiring accessories Individual Hot Feed Fuse Block Common Hot Feed Block Nickel-plated phosphor-bronze plated fuse clips. Hard fiber insulator base with 11/64" (4.4mm) diameter mounting holes. Width: 2 1/4" (57.2mm), height 5/8" (15.9mm). Plated steel terminals and screws or (with M- prefix numbers) with brass terminals and screws. Mounting holes .75" (19.0mm) on centers. M-414-01, Brass 4-Gang Length: 2 3/4" (98.5mm). J Fiber base, 2.24" (56.9mm) wide, with 11/64" (4.4mm) diameter mounting holes. Solid brass busbar, phosphor-bronze fuse clips. Height: 5/8" (15.9mm). Brass terminals and screws. BP O R BS EF O ER LE T EN E C FO E R O N LY M-415-01, Brass 5-Gang Length: 3 1/2" (88.9mm). Also available with steel terminals and screws: 4625-01. 4622*, Steel 2-Gang Length: 1 1/4" (31.8mm). 4623*, Steel 3-Gang Length: 2" (50.8mm). 4624, Steel 4-Gang Length: 2 3/4" (69.9mm). 4625, Steel 5-Gang Length: 3 1/2" (88.9mm). 4626, Steel 6-Gang Length: 4 1/4" (108.0mm). M-412, Brass 2-Gang BP Length: 1 1/4" (31.8mm). M-641-01, Brass 6-Gang BP Length: 4 1/4" (108.0mm). Also available with steel terminals and screws: 4626-01. M-643-01, Brass 8-Gang Length: 5 3/4" (146.1mm). BP M-645-01, Brass 10-Gang Length: 7 1/4" (184.2mm). M-647-01, Brass 12-Gang Length: 8 3/4" (222.3mm). J4 terminal blocks M-413, Brass 3-Gang Length: 2" (50.8mm). Terminal Blocks, Individual Feed M-414, Brass 4-Gang Length: 2 3/4" (69.9mm). Moisture-repellent molded Bakelite insulator base with barrier strips. Nickel-plated brass terminal links and 8-32 binding head screws. Width: 1.31" (33.3mm), height: .67" (17.0mm). M-415, Brass 5-Gang Length: 3 1/2" (88.9mm). M-426, 4-Gang BP Length: 3.22" (81.8mm). Paired mounting holes 2.81" (71.4mm) on centers. M-427, 6-Gang BP Length: 4.33" (110.1mm). Paired mounting holes 3.93" (99.9mm) on centers. fuse-style breakers See page 67. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 69 J circuit protection & wiring accessories 4721-P8, 8-Gang Length: 6.37" (161.8mm). Eyelets are 5.62" (142.7mm) on centers. M-428, 8-Gang BP Length: 5.46" (138.7mm). Paired mounting holes 5.06" (128.5mm) on centers. 4721-P10, 10-Gang Length: 7.62" (193.5mm). Eyelets are 6.87" (174.5mm) on centers. M-429, 10-Gang BP Length: 6.59" (167.4mm). Paired mounting holes 6.19" (157.2mm) on centers. 4721-P12, 12-Gang Length: 8.87" (225.3mm). Eyelets are 8.12" (206.2mm) on centers. M-456, 14-Gang Length: 8.84" (224.5mm). Paired mounting holes 8.44" (214.4mm) on centers. O R BS EF O ER LE T EN E C FO E R O N LY 4721-P14, 14-Gang Length: 10.12" (257.0mm). Eyelets are 9.37" (238.0mm) on centers. With Stud Terminals Round end pattern Square end pattern 10-32 thread stud terminals with hexnuts, flat washers and lockwashers. Two eyelet mounting holes for 3/16" (4.8mm) screws (screws not included). Moisture-repellent phenolic insulator base. 5/8" (15.9mm) wide x 27/32" (21.4mm) high. 10-24 thread stud terminals, hardware not included. Two mounting holes for 1/4" (6.3mm) screws (screws not included). Moisture-repellent molded insulator base with barrier strips. 5/8" (15.9mm) wide x 27/32" (21.4mm) high. 4721-P2, 2-Gang Length: 2.62" (66.5mm). Eyelets are 1.87" (47.5mm) on centers. 4758, 4-Gang Length: 4.5" (114.4mm). Two mounting holes 3.75" (95.3mm) on centers. 4721-P3, 3-Gang Length: 3.25" (82.6mm). Eyelets are 2.50" (63.5mm) on centers. 4755, 5-Gang Length: 5.25" (133.3mm). Two mounting holes 4.50" (114.3mm) on centers. 4721-P4, 4-Gang Length: 3.87" (98.3mm). Eyelets are 3.12" (79.2mm) on centers. Truck-trailer lighting pattern 4721-P5, 5-Gang Length: 4.5" (114.3mm). Eyelets are 3.75" (95.3mm) on centers. 4744 Six-gang, with circuit identification printed in white lettering. Two mounting holes 5.25" (133.4mm) on centers. 10-24 thread stud terminals, with hexnuts. 4 7/8"L x 1 3/16"W x 3/4"H (149.2 x 38.1 x 19.1mm). 4721-P6, 6-Gang Length: 5.12" (130.0mm). Eyelets are 4.38" (111.3mm) on centers. Rapid ship item. 70 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com circuit protection & wiring accessories Terminal Blocks, Common Busbar M-449, 10-Gang BP Solid brass busbar safely carries up to 150A. Two 1/4-20 brass studs with hexnuts. 8-32 round head screws for attachment of wires. Two mounting holes accept No.10 countersink flathead screws. Moisture-resistant molded thermoplastic insulator base. 5 3/4"L x 1 1/4"W x 1 1/32"H (146.0 x 31.7 x 26.1mm). Two mounting holes 5.19" (131.8mm) on centers. J J5 connectors and terminals Quick-Connect Taps Female molded plastic tap connector provides a fully insulated connection. Tap leg (see below) is disconnectable for added flexibility. 30244*, For 12AWG Wire Coded yellow. 25 per pack. O R BS EF O ER LE T EN E C FO E R O N LY 30243*, For 18-14AWG Wires Coded blue. 25 per pack. M-448, 20-Gang Same as M-449, but with 20 outlets. Length: 8 7/8" (225.4mm). Two mounting holes 8.31" (211.1mm) on centers. 46206-04 BP 4-gang, with solid brass busbar. 10-32 stud terminals with hexnuts and lockwashers. Two eyelets for mounting with 3/16" (4.76mm) screws (not included). Eyelets are 3.125" (79.4mm) on centers. Moisture-repellent thermoset plastic insulator base. 3 7/8"L x 5/8"W x 27/32"H (44.4 x 15.9 x 21.4mm). 30242*, For 22-18AWG Wires Coded red. 25 per pack. 31729, Tap Leg for 16-14AWG Male blade tap leg. Use with 30243 tap. Coded blue. 50 per pack. 31728, Tap Leg for 22-18AWG Male blade tap leg. Use with 30242 tap. Coded red. 50 per pack. 30223, Quick-Tap Splicer and Tap BP Use Quick-Tap to connect two wires or create a tap without stripping the wires. Two wires can be connected in-line or as a pigtail. Consists of a small molded plastic hinge unit. Insert the wires, close and snap shut with pliers. Fully insulated to prevent short circuits. Splicing instructions are included. 10 per pack. buzzers & alarms See page 80. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 71 circuit protection & wiring accessories J 30245 Quick-Connect Bullet Socket quick-tap wire splicer Mates with bullet terminals (31731 and 31739). Self-stripping connector provides fast and easy connect and disconnect for many vehicle applications, including vehicle to trailer connections. For 18AWG to 14AWG wires. 20 per pack. Part No. 30223 does it all! To make a Tap Splice With the splicer open: Press the existing circuit wire (red wire in the picture) into the outer channel. Press the tap wire (yellow) into the inner channel. Snap the splicer cover into place. Squeeze with pliers. 31731*, 16-14AWG. Blue Bullet Terminal For use with 30245. 50 per pack. 31739*, 22-18AWG. Red Bullet Terminal For use with 30245. 50 per pack. O R BS EF O ER LE T EN E C FO E R O N LY Inline Fuse/Breaker Holders 30147, For ATC/ATO Type BP Accepts ATO and ATC fuses and circuit breakers from 3A to 20A. Easy to install and easy to change the fuse. 16AWG insulated copper wire leads, 4" (101.6mm) long. Brass contacts. Supplied without a fuse. To make an Inline Splice With the splicer open: Press one wire (yellow) into the outer channel. Press the other wire (red) into the inner channel. Snap the splicer cover into place. Squeeze with pliers. To make a Pigtail Splice With the splicer open: Press one wire (red) into the outer channel. Press the other wire (yellow) into the inner channel. Snap the splicer cover into place. Squeeze with pliers. 3031, For Glass Fuses Accepts SFE fuses through 20A and 3AG (AGC) fuses through 30A. Positive twist-lock seal will not open accidentally; large brass contacts maintain solid contact with the fuse for maximum efficiency. 14AWG wire leads, 8" (203.2mm) long. Brass contacts. To install, cut wire loop. 3031-0, Without Fuse BP 3031-4*, With 4A Fuse 3031-9*, With 9A Fuse 3031-14, With 14A Fuse 3031-20, With 20A Fuse BP 3031-30, With 30A Fuse Rapid ship item. 72 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com circuit protection & wiring accessories Connectors with Quick-Connect Terminals J 31100, Female Terminal for 14-16AWG Wire For fast wiring installation on vehicles and equipment. Molded insulators are made of durable, flexible polypropylene, which provides excellent resistance to moisture, chemicals and abrasion. Brass quick-connect terminals. Packaged 100 pieces per box. One Pole, Single Body Connector Two Pole, Two-Piece 30204, Female Insulator O R BS EF O ER LE T EN E C FO E R O N LY 30200*, Insulator 31102*, Male Terminal for 14-16AWG wire Receives two male terminals 31595-A. Three Pole, Two-Piece 30205*, Male Insulator Receives three female terminals 31100. 31103, Female Terminal for 14-16AWG Wire 30206*, Female Insulator One Pole, Two-Piece Connector 30201*, Male Insulator Receives one female terminal. 30202*, Female Insulator ignition See Section B. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 73 J circuit protection & wiring accessories Insulated Terminals and Connectors Female Blade Terminals For use with crimping tool. Tin-plated copper for resistance to corrosion and maximum conductivity. Vinyl insulator has ridge for positioning of crimping tool, and is flared for easy insertion of wire. 31340*, For 22-18AWG Wire. Red Terminals are packed 100 per box. Blade width .250" (6.4mm). Color-coded by wire size: 22-18AWG wire: red 16-14AWG wire: blue 12-10AWG wire: yellow 31341*, For 22-18AWG Wire. Red 31738*, For 12-10AWG Wire. Yellow Ring Terminals Butt Connectors Terminals are packed 100 per box. For efficient two-wire connections. Blade width: 1.00" (25.4mm). Packed 50 per box. O R BS EF O ER LE T EN E C FO E R O N LY 30238, For 12-10AWG Wire. Yellow 31302*, For 22-18AWG Wire, Stud Size 8. Red 31304*, For 22-18AWG Wire, Stud Size 10. Red 31301*, For 16-14AWG Wire, Stud Size 6. Blue 30220*, For 16-14AWG Wire. Blue 31305*, For 16-14AWG Wire, Stud Size 10. Blue 30219*, For 22-18AWG Wire. Red 31732*, For 12-10AWG Wire, Stud Size 6. Yellow 30240 Moisture-Resistant Butt Connectors. Blue Weather-resistant connections can be made easily without a heat source or additional protective material. For 16-14AWG. 31734*, For 12-10AWG Wire, Stud Size 10. Yellow Snap-On Spade Terminals Terminals are packed 100 per box. 31322*, For 22-18AWG Wire, Stud Size 8. Red 31324*, For 22-18AWG Wire, Stud Size 10. Red 31321*, For 16-14AWG Wire, Stud Size 6. Blue 31323*, For 16-14AWG Wire, Stud Size 8. Blue emergency cutoff 31325*, For 16-14AWG Wire, Stud Size 10. Blue 31735*, For 12-10AWG Wire, Stud Size 6. Yellow Emergency cutoff switches are commonly mounted on many types of vehicles such as buses, and those used in construction and agriculture. Fire departments routinely familiarize themselves with the location of cutoffs, so that power can be quickly turned off in case of emergency. Additionally, OSHA requires cutoffs on certain vehicles, particularly those with ancillary motorized equipment, such as garbage trucks. See Section D1. 31736*, For 12-10AWG Wire, Stud Size 8. Yellow 31737*, For 12-10AWG Wire, Stud Size 10. Yellow Rapid ship item. 74 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com circuit protection & wiring accessories Special Purpose Connectors 3032, Flasher Connector Accepts standard 3-prong flasher units (not included). Molded plastic connector has 14AWG wire leads, with phosphor-bronze contacts. Comes with plated steel bracket that has two .203" (5.2mm) diameter mounting holes. J 30156 Fits Cole Hersee switches 7702 and 7776 Trucks: Autocar 68-80, Chevrolet 61-86, GMC 69-86, International 61-80, Freightliner 63-67, 72-80, Kenworth 65-67, 72-74, 77-80. J6 clamps, cleats, clips & ties Spring Clip 3118 BP Teeth hold the clip in place after it is snapped over material up to 3/16" thick (4.8mm). Plated for corrosion resistance. 1/2" wide, 1 1/2" long (12.7 x 38.1mm). O R BS EF O ER LE T EN E C FO E R O N LY 4028, Headlight Harness For Chevrolet and GMC RVs. Accepts one 3-prong headlamp and one 2-prong headlamp. This harness attaches to a 3-pole Packard connector that is supplied with the vehicle chassis. Leads are 16AWG wire that connects into silvered bronze contacts in molded plastic connectors. Steel Clamps Plastic-Coated Clamps Plastic-coated for corrosion protection. Mounting hole diameter .281" (7.13mm) unless noted. Sealed Beam Connectors & Parts Accepts sealed-beam headlamp terminals. 8" (203.0mm) 14AWG thermoplastic wire leads with plated bronze contacts. 3029, Connector with 3 Leads BP 3051, Connector with 2 Leads 31230, .187" ID, .281" Hole .187" inside diameter (4.74mm). 31231, .281" ID, .281" Hole .281" inside diameter (7.13mm). 31232, .312" ID, .281" Hole .312" inside diameter (7.92mm). 31233, .437" ID, .281" Hole .437" inside diameter (11.09mm). 31234, .562" ID, .281" Hole .562" inside diameter (14.27mm). Dimmer Switch Connectors 30155 Fits Cole Hersee foot switch 7762 Ford trucks 60-87, Dodge trucks 59-86. 31235, .750" ID, .250" Hole .750" inside diameter (19.05mm), mounting hole diameter .250" (6.35mm). 31236, .875" ID, .281" Hole .875" inside diameter (22.22mm). 31237, 1.187" ID, .343 Hole 1.187" inside diameter (30.14mm), mounting hole diameter .343" (8.71mm). Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 75 J circuit protection & wiring accessories Steel Clamps Steel Cleats 31017*, 7/16" ID 7/16" inside diameter (11.1mm), mounting hole diameter 13/32" (10.2mm). PVC Coated Plated for corrosion resistance. Plastic coated for corrosion resistance. 31200*, 1/4" ID 1/4" inside diameter (6.4mm), mounting hole diameter 13/64" (5.2mm). 31018*, 9/16" ID 9/16" inside diameter (14.3mm), mounting hole diameter 9/32" (7.1mm). 31019*, 9/16" ID 9/16" inside diameter (14.3mm), mounting hole diameter 1/4" (6.4mm). 31201*, 3/8" ID 3/8" inside diameter (9.5mm), mounting hole diameter 13/64" (5.2mm). 31202*, 1/2" ID 1/4" inside diameter (12.7mm), mounting hole diameter 13/64" (5.2mm). O R BS EF O ER LE T EN E C FO E R O N LY Nylon Clamps Inside edges are beveled to protect harnesses from chafing. Mounting hole diameter .167" (4.3mm) unless stated. 31203*, 5/8" ID 5/8" inside diameter (15.9mm), mounting hole diameter 17/64" (6.7mm). 31240, 3/16" ID BP 3/16" inside diameter (4.8mm). 31204*, 3/4" ID 3/4" inside diameter (19.1mm), mounting hole diameter 17/64" (6.7mm). 31205, 1" ID 1" inside diameter (25.40mm), mounting hole diameter 17/64" (6.7mm). 31241, 1/4" ID BP 1/4" inside diameter (6.4mm). Plated Steel 3160*, 1/4" ID 1/4" inside diameter (6.4mm), mounting hole diameter 13/64" (5.2mm). 31242, 5/16" ID BP 5/16" inside diameter (8.0mm). 31243, 3/8" ID 3/8" inside diameter (9.52mm). 31244, 1/2" ID BP 1/2" inside diameter (12.7mm). 3161, 3/8" ID 3/8" inside diameter (9.5mm), mounting hole diameter 13/64" (5.2mm). 31245, 5/8" ID BP 5/8" inside diameter (15.9mm). Mounting hole diameter .203" (5.2mm). 3162*, 1/2" ID 1/2" inside diameter (12.7mm), mounting hole diameter 13/64" (5.2mm). 31246, 3/4" ID BP 3/4" inside diameter (19.1mm). Mounting hole diameter .203" (5.2mm). 3163*, 5/8" ID 5/8" inside diameter (15.9mm), mounting hole diameter 17/64" (6.7mm). 3164*, 3/4" ID 3/4" inside diameter (19.1mm), mounting hole diameter 17/64" (6.7mm). Rapid ship item. 76 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com monitoring devices k1 temperature switches K k2 oil pressure switches All items are self-grounding, normally Off. Heavy duty, corrosion-resistant. Switches utilize PTF or NPTF dryseal thread which requires no sealant. Switches close a ground circuit to indicator lights or other warning devices that warn of a 'hot' or 'cold' condition. Cannot be used with gages. .250" blade (6.4mm) terminal except where noted. SPST, Grounded, Normally On 84229 On at 246to 266F. 3/8" -18 Thread. 3/8" -18 dryseal thread mounting stem (NPTF). Mounting hex flat 13/16". Stud terminal. (118.9 - 130.0C). 8606 Off at: 2 - 6 psi. 1/8" -27 Thread. Normally On, Off at: 2 - 6 psi (13.8 - 41.4 kPa). .250" blade terminal. 1/8" -27 mounting stem. Replaces: Delco F1853, Ford C8GY, D1FZ, D6AZ, E43Z10884A, Motorcraft SW-663, SW-983, SW-1344, SW-1344. Replaces: AMC 1539889, 3142826, Chrysler 4169629, Delco 499581, 534598, 1359289, 1408319, 1508319, 668, 1598319, 1994214, 1998713, 3200422, 3818783, 5653196, 397, 462, D-2471, Ford D0RY-9278-A, International 280891-C91, 356079C, 425491-R91, 31428266, Motorcraft Sw-334, SWG-334, SWE-1030, Trucks: Chevrolet 85-89, Dodge 85-86, GMC 85-89, International 59-67, 78-80. O R BS EF O ER LE T EN E C FO E R O N LY Self-grounding SPST Normally On (except 86302-02). Contacts open at rising pressure, close at falling pressure. Heavy duty construction. Weather-resistant. Plated steel case. Molded moisture-repellent insulators. Conservative burst pressure: 750 psi (5171.1 kPa). 84236 On at 251 to 283F. 1/2" -14 Thread. 1/2" -14 dryseal thread mounting stem (PTF-SAE short). Mounting hex flat 15/16". (122.0 - 139.4C). .250" blade terminal. Replaces: Delco 1993445, 1993496, 1994061, D1867, D1879, GMC 6489179, 6489395, 6489766, 6490694, 6490970, 25036512, Motorcraft SWG-1187, SWG-1340. 84248 On at 253 to 273F. 3/8" -18 Thread. 3/8" -18 dryseal thread mounting stem (NPTF). Mounting hex flat 13/16". (122.8 - 133.9C). .250" blade terminal. Replaces: Delco D-1896, GMC 8992347, 8993427, 25036035, 042, 139, 300, 371, 452, 468, 535, Motorcraft SWG-2051. 8609 Off at: 4.5 - 7.5 psi. 1/8" -27 Thread. Normally On, Off at: 4.5 - 7.5 psi (31.0 - 51.7 kPa). 8-32 stud terminal. 1/8" -27 mounting stem. 8610 Off at: 4.5 - 7.5 psi. 1/8" -27 Thread. Same as 8609, but with combination blade and stud terminal. 86263* Off at: 2.5 - 5 psi. 1/4" -18 Thread. Normally On, Off at: 2.5 - 5 psi (17.2 - 34.5 kPa). .250" blade terminal. 1/4" -18 mounting stem. Replaces: Chrysler 4379037, Delco 1370748, 1508648, D-1805, Motorcraft SW-611, SWG-611. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 77 K monitoring devices SPST, Insulated, Normally Off 86281 1/8" -27 Thread. Mounting stem: 1/8"-27 dryseal thread. Operation: circuit 1 - terminal 2 normally closed to ground, opens at 2 - 8 psi (13.8 - 55.2 kPa); circuit 2 - terminals 1 & 3 normally open, close at <11 psi (75.9 kPa). 86272 On at: 2 - 6 psi. 1/8" -27 Thread. On at 2 - 6 psi (13.8 - 41.4 kPa). Mounting stem: 1/8"-27 dryseal thread. Replaces: Delco 45784, 10012967, 10018158, 10002798, 25036001, Motorcraft SWG-1702. Replaces: AMC 331347, Chrysler 3747431, Delco 14057554, Jeep 4186352, Motorcraft SWG-1708. 86284 On at: 2 - 6 psi. 1/8" -27 Thread. On at 2 - 6 psi (13.8 - 41.4 kPa). Mounting stem: 1/8"-27 dryseal thread. O R BS EF O ER LE T EN E C FO E R O N LY 86283* 3/8" -18 Thread. Mounting stem: 3/8"-18 dryseal thread. Operation: circuit 1 - terminal 2 normally closed to ground, opens at 4 - 7 psi (27.6 - 48.3 kPa); circuit 2 - terminals 1 & 3 normally open, close at 6 - 9 psi (41.4 - 62.0 kPa). Replaces: AMC 5758695, Delco 10001858, 14004902, 25036279, 533, D-1818, International 1324244-R91, Motorcraft SWG-1709. Replaces: Chrysler 3747430, 3747722, 4205921, CH-2490, Motorcraft SWC-1710. DPST, One Grounded, One Insulated Circuit k3 Air pressure & vacuum switches For dependable operation of low air pressure warning systems. Sealed contact design to prevent short circuits caused by moisture and contaminants. SPST Normally On. Contacts open at rising pressure. 86279* 10 x 1mm Thread. Mounting stem: 10x1mm taper pipe thread. Operation: circuit 1 - terminal 2 normally closed to ground, opens at 4 - 6 psi (27.6 - 41.4 kPa); circuit 2 - terminals 1 & 3 normally open, close at 5 - 7 psi (34.5 - 48.3 kPa). Replaces: AMC 3250466, Chrysler 4186353, 4267021, 5209953, CH-2489, Motorcraft SWX-1707. 8604 Off at: 55 - 65 psi. 1/4" -18 Thread. Mounting stem: 1/4" -18 dryseal thread 15/32" long. Insulated. Normally closed, open at 55 - 65 psi (379.2 - 448.2 kPa). 8-32 screw terminal. 2 1 Rapid ship item. 78 BP Available in retail clamshell pack. 3 Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com monitoring devices K 8640 Off at: 60 - 70 psi. 1/4" -18 Thread. Mounting stem: 1/4" -18 dryseal thread. Normally closed, open at 60 - 70 psi (413.7 - 482.6 kPa). 8-32 stud terminal. Normally Off, SPST Replaces: Chrysler 1787025, 1788700, Delco 3750911, 3929518, Ford B6Q, B8Q-18737A, C5TZ-2A574A, International 194702-R91, Motorcraft SW-377. Operation: Make at 7 - 13 inches of mercury, (23.7 - 44.0 kPa). Mounting stem: 1/8" -27 dryseal thread. 92007, On at 7 - 13" Hg Insulated. Contacts close at rising vacuum, contacts open at falling vacuum. k4 fuel pump switch 8647, Normally Off, Electric Fuel Pump Switch Operation: Contacts close at 3.5 - 6.5 psi ( 44.9 - 24.2 kPa) Mounting stem: 1/8" -27 dryseal thread 11/32" long. .250" blade terminals. Insulated contacts. O R BS EF O ER LE T EN E C FO E R O N LY 8646 Off at: 60 - 70 psi. 1/4" -18 Thread. Mounting stem: 1/4" -18 dryseal thread. Normally closed, open at 60 - 70 psi (413.7 - 482.6 kPa). 8-32 screw terminal. Replaces: Chrysler 1787025, Mack 1MR-1169AP1, White 495537. Replaces: Chrysler 1841416, 2510026, International 217552-R-91. Normally On, SPST Contacts open at rising vacuum, contacts close at falling vacuum. Mounting stem: 1/8" -27 dryseal thread. Operating range: 9 - 12 inches of mercury, break (30.5 - 40.6 kPa). 8641, Self-Grounding Replaces: AMC 3157693, 3202448, International 196198-R91. types of thread Information on most threads can be found in the ANSI standards, the SAE Handbook, and the National Institute of Standards and Technology Handbook H-28. UNC is the most commonly used thread on general-purpose fasteners. UNC threads are deeper than UNF threads and are easier to assemble without cross threading. Manufacturing tolerances can be larger than for finer threads, allowing for higher plating tolerances. Because of their looser fit, UNC threads are usually easier to remove when corroded. 9253, Insulated Replaces: AMC 3156149, Chrysler 1770093, CH-2569, Ford C2TA-11516-A. UNF thread has a larger minor diameter than UNC thread, which gives UNF fasteners slightly higher load-carrying and better torque-locking capabilities than UNC fasteners of the same material and OD. UNF threads have a smaller lead angle that allows for finer tension adjustment. They also have more stringent manufacturing tolerances than UNC threads. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 79 monitoring devices K k5 warning devices Buzzers & Alarms 4099, Universal Buzzer 12V DC BP Hundreds of uses. For `door ajar' warning, bus driver alert, low air pressure, temperature, etc. Works with any temperature, pressure, door or momentary switch. Electrical contacts are designed for instant response and uninterrupted signal. 4112-RC, Buzzer/LED "Dual Alarm" BP Rugged combination warning light and buzzer give audible and visible alert. Universal application: use with any electrical switch. Red lens, long-life LED. 11/16" (17.46mm) diameter mounting stem, 17/32" (13.88mm) long. Body size: 1 7/8"L x 1"W x 1 11/32"H ( 47.6 x 25.4 x 34.1mm). Wiring instructions provided. 12V DC. BP O R BS EF O ER LE T EN E C FO E R O N LY 4124-RD, Buzzer/LED "Dual Alarm" 24V 40151, 24V Buzzer Same as 4099, but for 24V DC systems. 40100, Buzzer Pull Switch Attaches to a cord. For use by passengers in buses and rapid transit vehicles. Extra heavy duty construction. Use with Cole Hersee buzzers or buzzer/flashers: 4099, 4112 RC, 4124-RD. SPST Off-Mom. On. Normally Off, pull to On, spring return to Off. For use with systems up to 36V DC. Two screw terminals. Neutral gray enamel finish cover. Operates with a pull cord. Replaces: Delco 1998723, 18998802, 1998020. 40212, Dual Rate Electronic Alarm 12V DC Utilizes advanced integrated circuit surface mount technology. Negative ground. Use with two input sources to warn of two different hazardous conditions. Sounds at two different rates: one sensor triggers a fast-rate alarm, the second actuates a slower rate alarm tone. Minimum sound level: 90dB. Lightweight molded plastic housing. Solid-state circuitry. Size: 2.005"L x 1.185"W x .930"H (50.4 x 30.3 x 23.6mm). Plugs into Cole Hersee Sealed Beam Connector 3032 or 3029, Delphi (Packard) 12033871, or accepts individual connectors for 1/4" (6.4mm) blades. SENSOR OR SWITCH FAST LVD SLOW B B+ + SENSOR OR SWITCH New electronic Low Voltage Disconnect Switch automatically disconnects accessory circuits to maintain starting power, then reconnects them when battery is recharged. See page 39. Rapid ship item. 80 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com monitoring devices k6 Pilot Lights LED Pilot Lights With rugged light-emitting diode light source that ensures long hours of service. Never needs bulb replacement. Mounting hole: 0.546" diameter (13.9mm). Quick connect .250" (6.4mm) terminals are polarized for ease of wiring. Body length 1.248" (31.7mm), maximum bezel diameter 0.630" (16.0mm). Fits into panels .020" through .300" thick (0.5 to 7.6mm). Nickel-plated washer and hexnut. Also available in 24V- Contact Cole Hersee. K PL-2, Series with Small 3/16" Lens 12V #53 bulb supplied. 3/16" (4.76mm) diameter lens. 5/16" (7.9mm) diameter mounting stem, 3/8" (9.5mm) long. Plated brass bezel, satin finish, 1/2" (12.7mm) diameter. PL-2-AC*, Amber Lens PL-2-BC, Blue Lens PL-2-GC, Green Lens PL-2-RC, Red Lens PL-612-B, Blue Lens, 12V PL-118 Series, rear mounting Mount through rear of the panel. Satin finish or black aluminum bezel, 15/16" (23.8mm) diameter. 12V #1893 bulb supplied. 5/8" (15.9mm) diameter lens. 11/16" (7.5mm) diameter mounting stem, 1/4" (6.4mm) long. Available with custom imprinting: contact Cole Hersee. PL-612-A, Amber Lens, 12V PL-118-AC, Satin Bezel, Amber Lens PL-612-R, Red Lens, 12V O R BS EF O ER LE T EN E C FO E R O N LY PL-612-G, Green Lens, 12V PL-118-GC, Satin Bezel, Green Lens PL-118-RC, Satin Bezel, Red Lens PL-118-AC001, Black Bezel, Amber Lens PL-118-GC001, Black Bezel, Green Lens PL-118-RC001, Black Bezel, Red Lens Incandescent Pilot Lights Corrosion-resistant construction. Spring-actuated brass contacts assure proper contact with the bulb. 16AWG (1.0mm2) insulated stranded copper leads, 8" (203mm) long. Many items are available with custom imprinting: contact Cole Hersee Single Contact, Insulated Smooth Lens Plastic socket. PL-6-RC, With Small 5/16" Lens, Chrome Bezel Red lens. Chrome-plated brass bezel, 7/8" (22.2mm) diameter. 3/4" (19.1mm) diameter mounting stem, 11/16" (17.5mm) long, 3/4-32 UN-2A. 5/16" (7.9mm) diameter lens. 12V #56 bulb supplied. PL-116 Series, Front Mounting Mount from the front of the panel, fasten from the back. Satin finish or black aluminum bezel, 15/16." (23.8mm) diameter. 12V #1893 bulb supplied. 5/8" (15.9mm) diameter lens. 3/4" (19.1mm) diameter mounting stem, 3/8" (9.5mm) long. Available with custom imprinting: contact Cole Hersee. PL-116-AC*, Satin Bezel, Amber Lens PL-116-GC, Satin Bezel, Green Lens PL-116-RC, Satin Bezel, Red Lens PL-116-GC001*, Black Bezel, Green Lens PL-116-RC001, Black Bezel, Red Lens Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 81 K monitoring devices Single Contact, Grounding PL-20, Series with Extra Wire for Ground 12V #53 bulb supplied. 17/32" (13.5mm) diameter lens. 3/4" (19.1mm) diameter mounting stem, 11/16" (17.5mm) long. Chrome-plated brass bezel, 7/8" (22.2) diameter. Available with custom imprinting: contact Cole Hersee. Self-grounding to metal panels. Smooth Lens PL-1, Series with Wmall 3/16" Lens, Chrome Bezel 12V #53 bulb supplied. 3/16" (4.8mm) diameter lens. 5/16" (7.9mm) diameter mounting stem, 3/8" (9.5mm) long. Chromeplated brass bezel, satin finish, 1/2" (12.7mm) diameter. PL-20-AC, Amber Lens PL-20-BC*, Blue Lens PL-20-GC, Green Lens PL-1-BC, Blue Lens PL-20-RC, Red Lens PL-1-GC, Green Lens O R BS EF O ER LE T EN E C FO E R O N LY PL-1-RC, Red Lens PL-5-RC, with Small 5/16" Lens, Chrome Bezel Red lens. Chrome-plated brass bezel, 7/8" (22.2mm) diameter. 3/4" (19.1mm) diameter mounting stem, 11/16" (17.5mm) long. 5/16" (7.9mm) diameter lens. 12V #53 bulb supplied. Faceted Lens PL-36, Series with Honeycomb Lens, Stainless Bezel Lenses have honeycomb pattern on the internal side, smooth on the outside. Satin finish stainless steel bezel, 3/4" (19.1mm) diameter. 1/2" (12.7mm) diameter mounting stem, 3/8" (9.5mm) long. 5/16" (8.0mm) diameter lenses. 12V #53 bulb supplied. PL-36-AC, Amber Lens PL-19, Series with Chrome Bezel 12V #53 bulb supplied. 17/32" (14.5mm) diameter lens. 3/4" (19.1mm) diameter mounting stem, 11/16" (17.5mm) long. Chrome-plated brass bezel, 7/8" (22.2mm) diameter. Available with custom imprinting: contact Cole Hersee. PL-36-BC, Blue Lens PL-36-GC, Green Lens PL-36-RC, Red Lens PL-19-AC, Amber Lens PL-19-BC, Blue Lens PL-19-GC, Green Lens PL-19-RC, Red Lens solenoids Solid state and electromechanical solenoids - See Section E. Rapid ship item. 82 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com monitoring devices Faceted Lens PL-85 Series 12V #67 bulb supplied. 15/16" (23.8mm) diameter lens, gasketsealed. 7/8" (22.2mm) diameter mounting stem, 3/4" (19.1mm) long. Plated brass bezel, 1 1/4" (31.8mm) diameter. Faceted outer lens surface. PL-85-AC, Amber Lens PL-85-GC, Green Lens PL-85-RC, Red Lens K PL-16 Series with Smooth Lens Marine construction. 16AWG (1.0mm2) insulated stranded copper leads, 8" (203mm) long. Many items are available with custom imprinting: contact Cole Hersee Double Contact. Metal socket. 17/32" (13.5mm) diameter lens. Chrome-plated brass bezel, 1 1/8" (28.6mm) diameter. 7/8" (22.2mm) diameter mounting stem, 1 1/8" (28.6mm) long. 12V #68 bulb supplied. Moisturerepellent insulator. Available with custom imprinting: contact Cole Hersee. PL-16-AC, Amber Lens PL-16-GC, Green Lens PL-16-RC, Red Lens O R BS EF O ER LE T EN E C FO E R O N LY PL-35-RC, With Honeycomb Lens, Stainless Bezel Red lens with honeycomb pattern on the internal side, smooth outer surface. Satin finish stainless steel bezel, 3/4" (19.1mm) diameter. 1/2" (12.7mm) diameter mounting stem, 3/8" (9.5mm) long. 12V #53 bulb supplied. 5/16" (8.0mm) diameter lenses. M-326 Series with Faceted Lens Marine construction. 16AWG (1.0mm2) insulated stranded copper leads, 8" (203mm) long. Many items are available with custom imprinting: contact Cole Hersee Double Contact. Metal socket. 15/16" (23.8mm) diameter lens, gasket-sealed. Plated brass bezel, 1 1/4" (31.8mm) diameter. 7/8" (22.2mm) diameter mounting stem, 1 1/4" (31.8mm) long. 12V #68 bulb supplied. Moisture-repellent insulator. M-326-AC, Amber Lens M-326-GC*, Green Lens Double Contact M-326-RC, Red Lens BP PL-86 Series Large 15/16" Lens Insulated. 12V #68 bulb supplied. 15/16" (23.8mm) diameter faceted lens, gasket-sealed. 7/8" (22.2mm) diameter mounting stem, 3/4" (19.1mm) long. Plated brass bezel, 1 1/4" (31.8mm) diameter. PL-86-AC, Amber lens PL-86-GC, Green lens PL-86-RC, Red lens economical Illuminated tip toggle switches M-54111-01 and M-54111-02 combine the properties of a switch and a pilot light. Switch tips are illuminated White when Off - which makes it easier to locate in the dark. When the switch is On, the tip is illuminated Red. More economical than a switch and pilot light combination, the illuminated switches are simpler to wire. See page 28. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 83 K monitoring devices Double Contact, Insulated k7 hooded panel lamps Chrome-plated brass construction for exposed applications. For illumination of maps or other items, with minimal interference of driving visibility. Hood can be rotated to direct the light beam (except DL-75-12V, which has a fixed hood). 16AWG (1.0mm2) insulated stranded copper leads, 8" (203mm) long, except where noted. M-458, Through-Panel Mount Bright chrome-plated brass hood. 11/16" (17.46mm) diameter mounting stem, 3/8" (9.5mm) long. Bulb not included: suggested lamps: #64 (6V), #68 (12V), #1252 (24V). Single Contact, Self-Grounding Self-grounding in metal panels. DL-13, Wide-Aperture, Chrome Hood Bright chrome-plated brass hood with wide aperture. Mount through the panel. 11/16" (17.5mm) diameter mounting stem, 3/8" (9.5mm) long. Accommodates single-contact bayonet bulb. Suggested lamps (not included): #63 (6V), #67 (12V), #623 (24V). O R BS EF O ER LE T EN E C FO E R O N LY M-451, Flange Mount, with Switch BP Bright chrome-plated brass hood. Flange mounting, with two 9/64" (3.6mm) diameter mounting holes, 1 3/16" (30.16mm) on centers. Two screw terminals. Integral On-Off switch in the stem. Bulb not included: suggested lamps: #64 (6V), #68 (12V), #1252 (24V). DL-21, Wide-Aperture, Black Hood Same as DL-13, but with black finish steel hood. DL-3, Small Aperture Bright chrome-plated brass hood with low illumination aperture. 3/8" (9.5mm) diameter mounting stem, 23/32" (18.3mm) long. Bulb not included. Suggested lamps: #51 (6V), #53 (12V), #356 (24V). Rapid ship item. 84 BP Available in retail clamshell pack. Multi-Purpose Utility Light with Fixed Hood DL-75-12V Snap-in mounting. Brass socket. One 18AWG (0.8mm) wire lead, 30" long (793mm), with blade terminal. Snaps into 1 1/4" (31.8mm) holes in panels .150" to .250" (3.8 to 6.4mm) thick. One spring prong is eliminated for indexing in keyed holes. Gasket-sealed lens and weatherproof sleeve. Frosted non-glare lens. Chrome-plated brass bezel/hood 1.52" (38.7mm) diameter. Supplied with 12V #67 bulb. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com monitoring devices k8 Lamp sockets & accessories Bayonet Base Sockets Sockets accept incandescent or LED bulbs with corresponding bases.16AWG (1.0mm2) insulated stranded copper leads, 8" (203mm) long, except where noted. Single contact sockets accept BA15s base lamps. Suggested lamp numbers: 63, 67, 81, 87, 93, 97,103, 209,1073, 1129, 1133, 1141, 1156. K Wedge Base Accept lamp socket BA9 base lamps, lamp numbers 158, 161, 168, 194, 194A, 194NA (amber bulb). 25104 For side marker, tail, cornering and license plate. Replaces: AMC 4489535, Ford D0DZ-15A434B, D4)Z-13410E, D5VY-15A442A, D7AZ, DD7FZ-13412A, E1FZ-13410A, GMC 6294015, 6298886, 6298892, 6298935, 8918527, International 4189977C91, Motorcraft LS-18. Double contact sockets accept BA15d base lamps. Suggested lamp numbers: 64, 68, 82, 88, 90, 210,1004, 1076, 1130, 1142, 1158, 1176, 1178. 25103* For side marker, tail, turn signal and license plate. Replaces: Chrysler 3513686, 4055028. O R BS EF O ER LE T EN E C FO E R O N LY Double contact indexed sockets accept BA15z base lamps. Suggested lamp numbers: 1154, 1157, 1157A, 1157NA, 1534, 2057, 2057NA, 2357, 2357NA. Standard Base Single Contact 26145 For back-up, tail, stop, turn signal and cornering. Ground wire. Replaces: GMC 8909518, International 57121C91, Motorcraft LS-22. Nut & Lockwasher Mounting Screw terminals. 11/16" -32 mounting stem. Nut and lockwasher are included. 2106*, Double Contact Socket accepts BA15d base bulb. Double Contact, indexed Indexed with J-slots. 26152 For back-up, marker, park, turn signal and cornering. Replaces: GMC 8919916, 12013813. 2316, Double Contact 11/16" (17.5mm) outside diameter. Screw terminals. Can be used with 2911 brass sleeve for quicker socket assembly or replacement. Socket accepts BA15d base bulb. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 85 K monitoring devices 2610, Double Contact, Side Bracket Plated steel side bracket, with one 3/16" (4.8mm) hole. Socket accepts BA15d base bulb. 26100, Double Contact, Brass Socket BP 11/16" (17.5mm) outside diameter. Molded plastic insulator. Socket accepts BA15d base bulb. 3575, Single Contact, Bottom Bracket Plated steel bottom bracket, with two 13/64" (5.2mm) holes, 1/2" (12.7mm) on centers. Socket accepts BA15s base bulb. Snap-In Mounting Plated steel, snap-in mounting sockets. Miniature Base Sockets 2611*, Single Contact Mounting fits 3/4" (19.0mm) diameter hole. Socket accepts BA15s base bulb. O R BS EF O ER LE T EN E C FO E R O N LY Plated steel sockets Accept BA9 base lamps. Suggested lamp numbers: 51 (6V), 53 (12V), 356 (24V). Snap-In Mounting Single contact, snaps in to 5/8" (15.9mm) diameter hole. 8" (203.0mm) wire lead. Sockets accept BA9 base bulb. 2612, Double Contact Mounting fits 3/4" (19.0mm) diameter hole. Socket accepts BA15d base bulb. 2505 Also available: socket with spacer rings to fit other panel thicknesses. Consult Cole Hersee. 2670*, Double Contact Mounting fits 7/8" (22.2mm) diameter hole. Socket accepts BA15d base bulb. Bracket Mounting Plated steel. 2506 Ground lead is attached to the shell. 2609, Single Contact, Side Bracket Plated steel side bracket, with one 3/16" (4.8mm) hole. Socket accepts BA15s base bulb. interactive catalog Check the Cole Hersee website at www.colehersee.com You can do an interactive search for the exact item you need by going to `Product Catalog'. And there's an abundance of other product information, such as technical drawings and specs. Rapid ship item. 86 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com monitoring devices K Wedge Base Sockets Pigtail Assemblies Molded plastic shell, brass contacts. Twist lock into slotted hole. Accept lamp numbers 158, 161, 168, 192, 193, 193E, 194, 194A, 194NA (amber bulb). Cole Hersee supplies pigtail assemblies for replacement and OEM applications. For different lead lengths, colors and materials, please contact Cole Hersee. Leads are made from high quality 16AWG (1.0mm2) thermoplastic jacketed wire. Phenolic washers insulate the assemblies. 25100, Fits 1/2" Hole Fits 1/2" (12.7mm) diameter slotted hole. 2564, Double Contact, Standard Ears in line with contacts. Fits the following sockets: 2602, 2608, 2610, 2612, 26041. O R BS EF O ER LE T EN E C FO E R O N LY 25101*, Fits 5/8" Hole Fits 5/8" (15.9mm) diameter slotted hole. 2560, Single Contact Fits the following sockets: 2601, 2609, 2611, 2645, 2670, 3575, 26003, 26041. Lamp Socket Accessories 1624, Accessory Plug Single contact. Permits the use of a 12V double wire circuit from a standardautomotive accessory plug. .822" (20.9mm) diameter. 2561*, Single Contact Miniature Fits the following sockets: 2504, 2505, 2506, 2526, 2520. 1449*, GMC Lamp Socket Plug For GMC vehicle tail lamps. Single contact. .800" (15.2mm) diameter. relays & microrelays See pages 45-47 Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 87 special purpose switches L 9162 35A at 12V DC. Two female bullet terminals. Mounting stem 3/4" -16 UNF-2A thread, 31/64" (12.3mm) long. l1 neutral safety switches Heavy-duty switches for applications to 36V DC. Normally Off Ball Switches SPST. On with ball depressed, spring return to Off. Silver contacts. 35A at 12V DC, 20A at 24V DC, except where noted. Moisture-resistant insulators, corrosion-resistant metal housings. 9242 Two screw terminals. Mounting stem 9/16" -18 UNF-2A thread, 5/16" (7.9mm) long. Replaces: Chrysler 1527835, Clark 73631. 9162-03 Same as 9162, except with gasket on the mounting stem. Replaces: Massey 181140M94. Normally On Ball Switches Replaces: International 863187-R91. SPST. Off with ball depressed. Spring return to On. Silver contacts. 5A at 12V DC, 3A at 24V DC, except where noted. Moisture-resistant insulators, corrosion-resistant metal housings. 9242-07*, Self-Grounding Same as 9242 except one terminal is grounded to the switch housing and terminal insulator is sealed against moisture and dirt. 9224 Two screw terminals. Mounting stem 3/4" -16 UNF-2A thread, 31/64" (12.3mm) long, with aluminum gasket/washer. O R BS EF O ER LE T EN E C FO E R O N LY 9242-01 Same as 9242, but with brass gasket/washer. Replaces: Clark 224620 Replaces: John Deere AT71501. 9242-04, With Delphi (Packard) Connector 22" (559mm) harness includes 2-pole Delphi (Packard) connector 2984855, with two female blade terminals 6288106. Mounting stem 9/16" -18 UNF-2A thread, 5/16" (7.9mm) long. Plasticized housing provides protection against moisture and dirt. Internal gasket seal. Replaces: GMC 702733. 92105 Two female bullet terminals. Mounting stem 3/4" -16 UNF-2A thread, 31/64" (12.3mm) long, with aluminum gasket/washer. 92102 15A at 12V DC. Two-button head accepts standard female blade terminals, and will mate with Delphi (Packard) 2-pole connector 2962679, or equivalent. Mounting stem 9/16" -18 UNF-2A thread, 21/32" (16.7mm) long. 92107-04 20A at 12V DC. Two-screw terminals. Mounting stem 3/4" -16 UNF-2A thread, 31/64" (12.3mm) long. give warning Looking for a pilot light or audible warning? See page 80. Rapid ship item. 88 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com special purpose switches l2 back-up switches L Lever-Actuated Switch SPST, normally Off. On with plunger depressed, spring return to Off. 8486-05 9134 35A at 12V DC. Silver contacts. Transmission-mounted, extra heavy-duty. Compact design for mounting in areas where space is limited. Two female bullet terminals. 9/16" -18 thread mounting stem, 5/16" (7.9mm) long. 10A at 12V DC. SPST, Normally Off, contacts Open. Lever-actuated to On, spring return to Off. Two bullet terminals. Two 10-32 tapped mounting holes, 5/8" (15.9mm) on centers. 2 7/8" (73.0mm) long lever. Replaces: John Deere AM38713 Replaces: Chrysler 1343998, 2198779, Motorcraft SW-410 On O R BS EF O ER LE T EN E C FO E R O N LY 91113 20A at 12V DC. Silver contacts. Transmission-mounted, extra heavy-duty. Compact design for mounting in areas where space is limited. Two screw terminals. 9/16" -18 thread mounting stem, 5/16" (7.9mm) long. Off Replaces: Autocar 8E-01360, Brockway 128537, Diamond Reo 560-65, Kenworth AT-91-69 Mack 1MR-1320, Oshkosh 13320-F1, White 1743529. 75125, Back-up Alarm Switch SPST. Normally Off. Spring lever actuated to On, spring return to Off. Two screw terminals. Two 13/64" (5.2mm) diameter mounting holes, 1/2" (12.7mm) on centers. 5" (127mm) lever. 83377, Protective Boot For Neutral Safety and Back-up Lamp Switches. Molded of durable PVC to resist moisture and dirt. Internal ring forms a seal with the groove around the switch housing. Fits Cole Hersee switches with a 1 1/8" (28.6mm) hex housing: 9134, 9162, 9224, 9242, 9242-07, 92102, 92103, 92105, 92107-04. 9052 10A at 12V DC. Two screw terminals. 7/16" (7.9mm) diameter mounting stem, 7/16" -20 (7.9mm) long, with two flats for mounting in double-D hole. 1/2" (12.7mm) long button-head plunger. Replaces: Ford B9AF, C0AF, 51-A15520A, Jeep 710412, 721028, Motorcraft SW-410. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 89 L special purpose switches l3 overdrive Kickdown switches l4 foot-operated turn switches Through-floorboard mounting. Depress to On, spring return to Off. Two switches are needed for left and right turn signals. Sealed switches are plastic coated, providing protection against moisture dust and roadsplash. 7/8" (9.5mm) diameter stem. Three 1/4" -20 tapped mounting holes, 3/4" (19.0mm) and 1 3/4" (44.4mm) on centers. 12A at 12V DC. SPST, Normally On Off with plunger depressed, spring return to On. 9096-02 15A at 12V DC. With special diaphragm/mounting bracket, sealed to protect the mounting shaft. Plasticized body protects against moisture and dirt. Two 16AWG wire leads, 3" (76.2mm) long with female bullet terminals. Insulator sleeves protect the connections. 13/64" (5.2mm) diameter mounting holes, 1 1/2" (38.1mm) on centers. 1/4" (6.4mm) long plunger. O R BS EF O ER LE T EN E C FO E R O N LY 7792, Sealed, with Screw Terminals SPST, On - Momentary On 9106-02* 10A at 12V DC per circuit. Two circuits: No.1 normally On, No.2 On with plunger depressed, spring return to No.1. Four screw terminals. 7/16" -20 (7.9mm) diameter mounting stem, 7/8" (22.2mm) long with flat on stem for mounting in D-shaped hole. Gasketsealed terminal insulator. Plunger: 7/32" (5.6mm) long. 7785, Sealed, with Wire Leads Replaces: Chrysler 1479527, Jeep 717589. rotary dimmers See page 56 for rotary electronic dimmer switches. Rapid ship item. 90 BP Available in retail clamshell pack. Minimum order quantity may apply. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com special purpose switches l5 stoplamp switches SPST, Normally Off. Contacts close at rising pressure. Operate at 60 to 120 psi (414 to 827 kPa). Thread is NPTF dryseal thread for use without a sealant. Hydraulic 8626 Two 6-32 screw terminals. 1/8" -27 thread mounting stem, 11/32" (8.73mm) long. Replaces: Delco 476S, 4760, FWD 4760, 4765, GMC 403936, 476592, 1316600, Ford 100810B, 510C, Mack 5CG-114, 11MR-1152, Motorcraft SW-311, Wagner FC-1201, FC5106, White 58012-F, 443106, 1319522. 8486, Lever Actuated (R) SPST Normally On. Spring return to On. When viewed from the terminals, the lever projects to the right (see also 8487). Lever is 2 7/8" overall length. Two tapped 10-32 mounting holes, 5/8" on centers. Replaces: AMC 99469, Chrysler 1450341, Delco 4765, Ford 91A-13480, Jeep 647801, Motorcraft SWC-312, Wagner FC-5550, FC-6370. 8629 Two male bullet terminals. 1/8" -27 thread mounting stem, 11/32" (8.73mm) long. Replaces: AMC 300356, 3145198, 3192194, 4488306, Delco 4766, 4733, D850, Ford B8A, B9SF, C1AZ-13480A, GMC 1320938, 1328118, 1997725, Jeep 70034, 201466, 647801, Motorcraft SW-24, Wagner FC-6780, FC-7715, 179-318, AC5812W. Mechanical 8645 SPST Normally On. Spring return to On. 1/2" -20 thread mounting stem, 3/8" long. Plunger 11/32" long. On Replaces: Delco D851, D853, D855, GMC 1997901, 1997915, 1997922, Motorcraft SWG-317, Wagner FC-21630. 8487, Lever Actuated (L) SPST Normally On. Spring return to On. When viewed from the terminals, the lever projects to the left. Otherwise, the switch is identical to 8486. O R BS EF O ER LE T EN E C FO E R O N LY 8628 Two female bullet terminals. 1/8" -27 thread mounting stem, 11/32" (8.73mm) long. L Off On Off J1 Various Switch Diagram Replaces: Delco D852, D854, DR-2401, GMC 1997913, 1997921, Motorcraft SWG-318, 319, Wagner FC-21632. 8466, For Push or Pull Operation Normally Off. Push or pull to On, spring return to Off. 11/32" long plunger with 9/64" diameter hole for attachment of cable or actuating device. Four 13/64" diameter mounting holes. 1 1/2"L x 2"W center to center. J2 Various Switch Diagram l6 voltage reducers 68003, For 4A Maximum Load 1.5 Ohm resistance, 25W. Allows the use of 6V accessories in 12V electrical systems. The resistor coil is embedded into the ceramic insulator for effective heat dissipation. Voltage reducers can be wired singly in series or in parallel. For use with low amperage load accessories. Two screw terminals with lockwashers. 7/16" -28 thread mounting stem. Size: 2" x 2 9/16" x 1 1/2." 8715 SPST Normally On. Spring return to On. Moisture-resistant plastic body and plunger. 1/2" diameter mounting stem, 1 5/32" long. Replaces: AMC 3189147, 3194569, 4488295, 5352620, 9770419, Chrysler 2809033, Delco D864, D866, D868, D873, U850, U851,U852, D885, Ford C8ZZ-13480A, C7TZ, D2TZ-13480B, GMC 536289, 1261219, 1362835, 959, 1993509, 1998192, 196, 667, 3631535, 3889606, 3889607, 3952426, 9772188, 9776994, 14074323, 25524844, International 312739C91, 358560C91, Motorcraft SWG-535, SW-691A, SW-1512, VW 175957656A, Wagner FC-32200, FC-32085, FC-66780. Rapid ship item. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com BP Available in retail clamshell pack. Minimum order quantity may apply. 91 m additional information SPST, SPDT, DPST, DPDT Switches DPST On-Off Both load terminals can be energized at the same time. They are independent of each other and could be of different voltages. SP and DP refer to single pole and double pole, ST and DT refer to single throw and double throw. Pole refers to the number of circuits controlled by the switch: SP switches control only one electrical circuit. DP switches control two independent circuits (and act like two identical switches that are mechanically linked). Do not confuse `pole' with `terminal'. The DPST switch, for example, has four terminals, but it is a DP, not a 4P switch. Throw refers to the extreme position of the actuator: ST switches close a circuit at only one position. The other position of the handle is Off. DT switches close a circuit in the Up position, as well as the Down position (On-On). A DT switch can also have a center position (frequently On-Off-On). SPST On-Off O R BS EF O ER LE T EN E C FO E R O N LY The following switch diagrams illustrate the most common types of toggle and rocker switch. DPDT On-On Functions like two separate SPDT switches operated by the same actuator. Only two loads can be On at a time. SPDT On-On Only one of the loads can be energized at a time. DPDT On-Off-On Functions like two separate SPDT switches operated by the same actuator. Only two loads can be On at a time. SPDT On-Off-On Only one of the loads can be energized at a time. 92 Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com additional information SP & DP Switches Switches with One Pilot Light Diagrams represent both momentary contact or maintained contact switches. SPST Off-On, dependent 4 Dependent illumination. Three terminals. + B Switches without Pilot Lights 2 3 L SPST Off-On Two terminals. 4 B + L B + Diagram F 1 2 SPST Off-On, independent 3 3 L Diagram A Diagram A1 Independent illumination. Four terminals.To convert an independent switch into dependent, connect a jumper wire from terminal 3 to terminal 6, and connect terminal 4 to ground. SPDT On-Off-On 4 4 Three terminals. 1 + 2 L 3 + O R BS EF O ER LE T EN E C FO E R O N LY L1 + B B 2 DPST Off-On B L1 3 5 6 + + 1 + 4 B 3 L 6 Jumper Diagram G2 Independent illumination switch converted to dependent SPST Off-On, dependent & independent 4 Four terminals. B L2 L 3 Diagram C B + 2 L 6 3 L Diagram C1 DPDT On-On Six terminals. 2 Switches with Two Pilot Lights Four terminals. 2 6 Diagram G1 Independent illumination Diagram B + B 3 L2 B M 1 L1 B + L2 4 2 5 3 6 L3 + SPDT On-Off-On, or On-On, dependent Four terminals. 6 Diagram H 1 L1 B + B 4 2 3 L2 L4 Diagram J Diagram D SPDT On-Off-On, or On-On, independent DPDT On-Off-On Six terminals. L1 B L2 + 1 4 2 5 3 6 L3 + Four terminals. B L4 L1 B L2 + 1 4 2 5 3 6 Diagram K Diagram E Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com 93 M additional information SP & DP Switches with 8 Terminal Locations Some switches have a maximum of eight possible locations for terminals. Switches of this type include M-58031 Series and 58326 Series Rocker Switches. Diagrams represent both momentary contact or maintained contact switches. B + 8 L B 1 + L L 4 2 5 3 6 + B L Diagram P 7 5 + B L 6 B Diagram L + 2 3 L Diagram Q + O R BS EF O ER LE T EN E C FO E R O N LY B B + L 8 7 2 5 3 6 + B L L B Diagram M 1 + 2 3 L Diagram R B B + + 8 7 2 3 L L 4 5 + L 6 Diagram N B Diagram S B + L B L + 8 7 1 4 2 5 3 6 L + B L B L Diagram O 94 + 2 5 3 6 + B L Diagram T Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com additional information Battery Selector & Master Disconnect Switches M-752 & M-753 Key to diagrams: L = starter & load, SW = Battery Selector & Master Disconnect Switch, BAT = battery, ISO = Battery Isolator, COM = common, ALT = alternator REG = Regulator One engine and two batteries M Download instruction form IF-130 from our website. F B A + BAT 1 REG SW M-750 & M-751 + BAT 2 1 2 Download instruction form IF-63 from our website. F1 F2 COM L CUT One engine and two batteries ALT SW 2 BAT 2 + 1 + BAT 1 Two engines and two batteries, with battery isolator F L B + A REG O R BS EF O ER LE T EN E C FO E R O N LY BAT 1 ALT COM BAT 2 + 2 1 2 ISO 1 + BAT 1 L2 CUT ALT L1 SW 2 F1 F2 COM Two engines and two batteries BAT 2 + 1 L2 M-754 & M-754-01, M-755 & M-755-01 L1 Download instruction form IF-121-1 from our website. COM ALT One engine and two batteries IGN or ACC One engine, two batteries, with battery isolator BAT 1 BAT 2 SW BAT 2 + ALT + BAT 1 1 2 + + PL 2 PL 1 ISO L ALT L COM ALT Two engines and two batteries IGN or ACC Two engines, two batteries, two switches BAT 1 BAT 2 BAT 2 + SW 2 + SW 1 2 BAT 1 + + PL 2 PL 1 1 L2 L2 ALT 2 COM L1 ALT 1 L1 ALT COM Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com 95 additional information M Two engines, two batteries, two switches 3-Stud Type 48070, 48080, 48090, 48120, 48160, and 48161. 1. IGN or ACC BAT 1 BAT 2 2. IGN or ACC ALT + BAT + + IGN BATTERY ISOLATOR CIRCUIT BREAKER L PL 2 PL 1 PL 2 PL 1 ALT 2 L2 MAIN LOAD L SECONDARY LOAD ALT 1 L1 One engine and two batteries, with battery isolator + BAT O R BS EF O ER LE T EN E C FO E R O N LY Master Disconnect Switches IGN or ACC BAT 1 + + BAT 2 SPST Switches Download instruction form IF-126 from our website. ALT 2 PL 2 1 BAT + ISO SWITCH PL 1 STARTER SOLENOID STARTER MOTOR L ALT DPST Switches Download instruction form IF-109 from our website. Battery Isolators REGULATOR B F A 4-Stud Type SWITCH 48092, 48122 and 48162. BAT + STARTER SOLENOID ALT BAT A or B + IGN BATTERY ISOLATOR L MAIN LOAD + BAT STARTER MOTOR F GENERATOR OR ALTERNATOR CIRCUIT BREAKER L SECONDARY LOAD 75912 Switch For two high current loads. BAT + A B A B STARTER SOLENOID 96 STARTER MOTOR Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com additional information M How to Identify a Switch Solenoids You can find out the type of rocker or toggle switch by a quick visual inspection. Look at the back of the switch, where the terminals are. Notice that there are six possible terminal positions. Solenoids are relays which are commonly used to remotely switch a heavier current. By using a solenoid, the amount of heavy wiring needed to power the load is reduced, since the control circuit mounted inside the cab typically utilizes a smaller wire gauge. Toggle and rocker switches are designed so that each vertical set of terminals makes up one pole. Solenoids are commonly used to control starter and winch motors, and they have many other uses on vehicles of all kinds Pole 1 Pole 2 CONTROL CIRCUIT STUDS CONTROL CIRCUIT STUDS 1 4 3 2 2 2 5 3 3 HOUSING 4 COIL PLUNGER 6 1 O R BS EF O ER LE T EN E C FO E R O N LY You can see immediately that a switch with three vertically-organized terminals must be a SPDT. Now check the actuator (rocker or toggle handle) to see if the switch is 2-position or 3-position. 1 If it only has two terminals, it must be a SPST, the simplest of all switch configurations. Notice that the two terminals are organized vertically (never side-by-side). Terminals can be located at 1 and 2, 1 and 3, or 2 and 36. If it has terminals at 1, 3, 4 and 6, it must be a DPST. You can see that it utilizes the left side (pole 1) and right side (pole 2) of the switch -- two poles (DP). If it has six terminals, it's a DPDT. Check the actuator to see if the switch is 2-position or 3-position. 4 LOAD CIRCUIT STUDS LOAD CIRCUIT STUDS A typical 4-stud solenoid 4-stud solenoid diagram The diagram shows a magnetic coil surrounding a contact plunger. Before energization, the plunger is not electrically connected to the control circuit. When the control circuit is energized, the electromagnetic force induced in the coil attracts the plunger, which moves to close the load circuit. When the control circuit is de-energized, the spring-loaded plunger returns to its normal state and the load circuit is broken. In continuous duty applications, energization of the coil causes heating, therefore the solenoid housing will become warm even in normal operation. 3 2 B 1 4 3 2 1 4 B B SPST SPDT DPST DPDT L Solenoid in its normal state Control circut and load circuit open B L Energized solenoid Control circut and load circuit closed For more information on solenoids, visit the interactive training section of the Cole Hersee website: www.colehersee.com > Resource Center > Training. Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com 97 additional information M Trailer Connector Wiring Colors Trailer Connector Wiring Colors are not universal, so it's wise to check proprietary instructions, and to make an electrical test.The following colors are very commonly used. Properly installed tractor-trailer connectors are critical to the safe performance of a rig, which are routinely subjected to vibration, extreme weather conditions, as well as mechanical forces. We highly recommend that a trained technician performs the installation. It is the responsibility of the end-user to take into account the mounting location and environment, conductor type, size, flexibility and other installation parameters. 4-pole Green - Right turn and brake lights Yellow - Left turn and brake lights Brown - Taillights and clearance lights White - Ground Review the assembly procedure before assembly. A common error is to not slide a clamp, boot or housing onto the cable before connecting the wires. Recommended tools: screwdriver (preferably with torque limiter); soldering iron (preferably a solder pot), solder and flux; wire stripper and cutter; and ruler. 5-pole In addition to the above. Red - Backup lights Cut the cable, and strip the jacket to the recommended length. 6-pole Wire Color Coductor Number Cole Hersee Terminal Marking White 1 GD 2 TM 3 LT 4 S Ground return to towing vehicle Clearance, side marker, and identification lamps Left turn signal and hazard lamps Stop lamps and antilock device 5 RT Right turn signal and hazard lamps 6 A Continuous ABS power/Auxiliary Brown Yellow Red Green Black or Blue Function Tail lamp load goes with marker circuit 2. 7-pole Brown - Right turn and brake lights Red - Left turn and brake lights Green - Taillights and clearance lights Yellow - Auxiliary White - Ground Blue - Electric trailer brakes Black - Auxiliary Power/Battery Charge Wire Color Coductor Number Cole Hersee Terminal Marking White 1 W Black 2 BK Yellow 3 Y Red 4 R Green 5 G Brown 6 BR Blue 7 BL Slide the housing, spring coil or boot over the cable. Properly insert and position the tinned conductor into each terminal. Locate the tinned portion under the terminal screw before tightening the screw. Tighten the termination screws to the appropriate torques. Inspect the terminated connection for cut or loose strands, fragments of wire insulation between the terminal/conductor connection, bent terminals, loose or stripped terminal screws and other visible problems. Check that the correct connections have been made, by re-checking that the conductor jacket color matches the insulator coding. SAE coding convention for 7-pole connectors 98 Strip the wires to the recommended length, and tin them. Maintain a tight strand bundle before tinning, so that there are no loose strands. Re-tin if necessary. This makes it easier to insert the wires into the terminal, and helps to properly position the tinned strands at the right depth. O R BS EF O ER LE T EN E C FO E R O N LY Typical coding convention for 6-pole circuits Function Carefully slide the insulator into the connector housing, making sure that the insulator is fully seated. Don't twist or lever the terminated conductor after it has been inserted and locked into the insulator. This may damage the terminal and put stress on the terminated connection. Finally tighten the housing screw or cable clamp. Ground return to towing vehicle Clearance, side marker, and identification lamps Left turn signal and hazard lamps Stop lamps and antilock device Right turn signal and hazard lamps Tail and license plate lamps Continuous ABS power/Auxiliary Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com additional information Wiring for SureStartTM Automatic Low Voltage Disconnect Switch 48510 M AWG conversion See page 39. American Wire Gauge (AWG) is a US standard set of non-ferrous wire conductor sizes. Non-ferrous' usually implies copper, but it includes aluminum and other metals and alloys. - + Battery Momentary Switch 12V 50mA LED and/or Buzzer VIOLET Low Voltage Disconnect Switch WHITE ORANGE BLACK Ignition Switch The "gauge" refers to the diameter. Typical household wiring is AWG number 12 or 14. Telephone wire is much thinner at 22, 24, or 26. The higher the gauge number, the smaller the diameter and the thinner the wire and the less current it will safely carry. Thicker wire carries more current because it has less electrical resistance over a given length. Thus larger wire is used with high currents and when the voltage drop along its length must be minimized. For example: High output alternator wiring might be 2 AWG and the starter cable for a mid-sized engine 1 or 0 AWG. O R BS EF O ER LE T EN E C FO E R O N LY The metric equivalent is simply the diameter expressed in millimeters, and thus can be easily measured with calipers. Load Wiring for Series 48800 Timers/Dimmers Microprocessor unit handles up to 20A peak load. Power wires are 16AWG, control wires 18AWG, loops 22AWG. System voltage 12V DC (9 - 16V). Case size: 1.36" H (not including flange) x 1.97" W x 1.03" D (34.4 x 49.9 x 26.2mm). Flange is 0.32" H x 1.97" W (7.94 x 49.9mm). Mounting holes are 0.28" diameter (7.2mm), 0.56" on centers (14.3mm). + AWG mm 26 0.128 25 0.162 24 0.205 23 0.255 22 0.322 21 0.411 20 0.516 19 0.653 18 0.823 17 1.039 AWG mm 16 1.308 15 1.652 14 2.088 13 2.629 12 3.302 11 4.156 10 6.271 9 6.626 8 8.350 7 10.544 AWG mm 6 13.292 5 16.755 4 21.137 3 26.653 2 33.606 1 42.384 0 53.454 00 67.399 000 84.004 0000 104.091 BAT High side mom switch BAT + Red wire with black stripe L Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com 99 0 Relay Schematics & Terminal Layouts Other configurations are available by special order. See page 46. MicroRelay Schematics & Terminal Layouts Other configurations are available by special order. See page 46. 0.662 [16.81] Form A (SPST) FORM A TERMINALS Form A (SPST) 87 0.662 [16.81] 0.551 0.331 [8.40] 86 87 85 85 86 87 0.906 86 86 0.610 FORM A TERMINALS 30 85 0.705 [17.91] 0.354 30 30 DETAIL A 0.315 0.705 [17.91] 0.331 [8.40] 87 85 30 30 30 85 86 87 85 86 87 0.453 FORM A TERMINALS MA-250012-NN 40A Type has .250" terminals. 70A Type has .375" terminals. 1.024 0305 30 Form A (SPST) with suppression 86,87,87a 85 Cole Hersee Co. Form A (SPST) with suppression www.colehersee.com 0.662 [16.81] 0.705 [17.91] 86 (-) 0.030 TYP 0.906 87 (+) 0.354 86 85 0.248 2 PLCS 0.610 0.188 3 PLCS RESISTOR MA-250012-NN OR DIODE 30 Form C (SPDT) 85 30 85 Form C (SPDT) 0.662 [16.81] 86 87 87a RESISTOR OR DIODE Form C (SPDT) with suppression 87 0.315 [8.00] TYP 87 0.331 [8.40] 0.030 86 85 30 86 30 3085 85 87 87a (-) 87 87 86 (-) 87 87a (+) 30 87 87a 85 30 85 (-) (-) 86 868787 87a 87a (+) (+) 87 85 87 87a 86 30 87 85 0.315 0.331 [8.40] 0.705 [17.91] 0.177 30 SEE NOTE 11 RESISTOR DIODE RESISTOR ORORDIODE FORM C TERMINALS RESISTOR OR DIODE 86 FORM C TERMINALS 0.551 86 30 85 0.453 0.662 [16.81] 0.354 FORM C (SPDT) 0.177 [17.91] 0.705 85 FORM C TERMINALS 0.315 [8.00] 0.705 [17.91] 30 30 0.331 [8.40] 30 SEE NOTE 11 85 0.315 87 DETAIL D 0.331 [8.40] 87a 85 11 (+) 30SEE NOTE (+) Form C (SPDT) with suppression 0.315 [8.00] 87 86 87a 87a 8686 8787 87a RESISTOR OR DIODE FORM C TERMINALS 86 86 85 8785 86 DETAIL C RESISTOR OR DIODE FORM C TERMINALS 0.551 0.354 0.248 2 PLCS 30 0.188 3 PLCS RELAY CIRCUITRY 85 0.453 0.662 [16.81] 0.315 [8.00] FORM C (SPDT) 0.705 [17.91] 87a 0.662 [16.81] DETAIL B (-) 30 FORM A TERMINALS DETAIL D DETAIL C 30SEE NOTE 85 11 30 1.024 0.453 86 30 85 87 86,87,87a RELAY CIRCUITRY (+) 0.331 [8.40] Cole Hersee Co. DETAIL B 85 86 87 (+) RESISTOR OR DIODE www.colehersee.com (-) 86 (-) FORM A TERMINALS 0305 30 85 86 DETAIL A 0.315 87 0.331 [8.40] 0.705 [17.91] 85 0.551 0.453 87 30 FORM A TERMINALS 0.662 [16.81] O R BS EF O ER LE T EN E C FO E R O N LY 0 additional information M 0.453 FORM C TERMINALS Form 2 (SPST) with suppression 30 85 86 30 87 87 85 (-) 86 87 87 (+) RESISTOR OR DIODE 0.662 [16.81] 87 0.315 [8.00] 87 86 0.331 [8.40] 85 1.043 [26.5] Sq. Ref. 30 FORM 2 TERMINALS 100 Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com 85 86 87 O R BS EF O ER LE T EN E C FO E R O N LY notes Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com 101 O R BS EF O ER LE T EN E C FO E R O N LY notes 102 Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com O R BS EF O ER LE T EN E C FO E R O N LY notes Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com 103 (R) Heavy duty electrical products. On the road, off the road, on the job. Construction & Off-Road *Skidsteer Loaders *Graders *Cement Mixer Trucks *Excavators *Compactors O R BS EF O ER LE T EN E C FO E R O N LY *Backhoes *Pavers *Rollers *Bulldozers Emergency Vehicles *Ambulances *Police *Fire *Emergency Apparatus *Resuce Equipment Factory & Airport Vehicles *Runway Trucks Carriers *Foam Trucks *Baggage Handlers *People *Forklifts *Scissorlifts *Gensets Buses and RVs *Motor Homes *RVs *Motorcoaches *School *Buses *Tourist Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com buses Trolleys Vehicles Vehicles Street Trucks *Postal *Street *Utility Vehicles Company Trucks *Bucket Trucks *Delivery Trucks *Garbage Sweepers Trucks *Dumpster Trucks *Snowplows Groundskeeping *Golf Carts *Service Carts *Mowers *Ditch Diggers *Edgers *ATVs O R BS EF O ER LE T EN E C FO E R O N LY Cranes of all kinds *Crawler Cranes *Cherrypickers *Aerial Lifts and Platforms *Rigging Vehicles Cranes *Tower Cranes *Truck Cranes *Boom www.colehersee.com Agriculture, Forestry & Mining *Harvesters *Balers *Combines *Tractors *Swathers *Grapple & Windrowers *Feed Conveyors *Screen Skidders Plants Cole Hersee Co. 20 Old Colony Ave, Boston, MA 02127-2467 colehersee.com O R BS EF O ER LE T EN E C FO E R O N LY colehersee.com Manufacturers of DC electrical and electronic switches and connectors for the vehicle industry