Home > Product Details NAC Features High attenuation of common mode noise from 150kHz to 1MHz Single Phase 250 VAC Selectable leakage current Quick and easy push-down terminal. Just connect the wires, push down and tighten the screws with a screwdriver. DIN rail installation (option) RoHS Compliant Safety Agency Approvals UL1283 CSA C22.2 No.8 (C-UL) DIN EN133200 VDE0565 Teil 3-1 ENEC Rated Voltage [V] Rated Current [A] NAC-06-472 AC 1- 250 / DC250 6 NAC-10-472 AC 1- 250 / DC250 10 NAC-16-472 AC 1- 250 / DC250 16 NAC-20-472 AC 1- 250 / DC250 20 NAC-30-472 AC 1- 250 / DC250 30 NAC-04-472 AC 1- 250 / DC250 4 Model Ordering information High-attenuation type of common mode noise from 150kHz to 1MHz NAC series NAC -10 -472 1 2 3 -O 4 1Model Name 2Rated Current 3Line to ground capacitor code:See table 1.1. table1.1 Line to ground capacitor code Code 681 102 222 332 472 *1 Line to ground Leakage Current capacitor (Input 125/250V 60Hz) (nominal value) 680pF 75.5 A/ 150 A max 0.13mA/ 0.25mA max 1000pF 0.25mA/ 0.5 mA max 2200pF 0.38mA/ 0.75mA max 3300pF 0.5 mA/ 1.0 mA max 4700pF When the line to ground capacitor code is different, the attenuation characteristic is different. 4Options D :DIN rail installation type The terminal cover is retracted inside the unit DIN rail installation type is option * The dimensions change when the option is set. Refer to External view. Features of NAC series High-attenuation type of common mode noise from 150kHz to 1MHz - Single Phase 250 VAC - Quick and easy push-down terminal Just connect the wires, push down and tighten the screws with a screwdriver Specifications No. Items NAC-04-472 1 Rated Voltage[V] AC 1f 250 / DC250 NAC-06-472 2 Rated Current[A] 4 3 Test Voltage (Terminal-Mounting Plate) 2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity 6 NAC-10-472 NAC-16-472 NAC-20-472 NAC-30-472 10 16 20 30 4 Isolation Resistance (Terminal-Mounting Plate) 500 VDC 100MW minute at room temperature and humidity 5 Leakage current 125/250V 60Hz 0.5mA/1.0mA max 6 Voltage drop 1.0V max 7 Safety agency approval temperatures -25 to +85C (Refer to Derating Curve) 8 Operating temperature -40 to +85C (Refer to Derating Curve) 9 Operating humidity 20 to 95%RH (Non condensing) 10 Storage temperature/humidity -40 to +85C/20 to 95%RH (Non condensing) 11 Vibration 10 to 55Hz, 19.6m/s2 (2G), 3min. Period, 1hour each X, Y and Z axis 12 Impact 196.1m/s2 (20G), 11ms Once each X, Y and Z axis 13 Safety agency approvals UL1283, CSA C22.2 No.8 (C-UL), DIN EN133200 VDE0565 Teil3-1, ENEC (At only AC input) 14 Case size (without projection) /Mass 53X41X92 mm (WXHXD) /300g max (Option : -D refer to external view) Circuit Diagram Derating Curve Case 3 1 CY LINE LOAD CY 4 2 Noise Filter Load Factor [%] 100 80 60 40 20 0 -40 CY : Line to ground capacitor I-2 : Mounting Plate -30 -20 40 50 55 60 Ambient Temperature [C] 70 80 90 NAC,NAM,NAP,NAH series External view This product is shipped in the following condition, because it is equipped with push-down terminals. 1The terminal cover is retracted inside the unit. 2The screws for connecting the terminals are held in the up right position. Standard Type 92 82 0.5 2-f4.8 Mounting Hole (2.5) 77 27 2-Protection Earth 8 12 53 Output Terminal Name Plate 15 45 0.5 Input Terminal Output Terminal Input Terminal 6-M4 Mounting Plate Terminal cover (2) Terminal cover Closed the terminal cover Tolerance : 1 Mass : 300g or less 41 Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 Case : PBT Dimensions in mm Terminal block screw tighting torque M4:1.6N-m (16.9kgf-cm) max DIN rail installation Type 92 77 (2.5) (11) 2-Protection Earth 27 8 Input Terminal 12 Output Terminal 15 Input Terminal 53 Output Terminal Name Plate 6-M4 Terminal cover Mounting Plate (2) Terminal cover Closed the terminal cover 41 Tolerance : 1 Mass : 300g or less Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 Case : PBT (9) Dimensions in mm 7 Terminal block screw tighting torque M4:1.6N-m (16.9kgf-cm) max DIN rail Note when installing the noise filter on a DIN rail. Noise Filter When the noise filter is grounded through the DIN rail, the proper noise attenuation may not be achieved. Be sure to connect the protection earth (PE) of the noise filter body to the earth. I-6 DIN rail Name Plate Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Cosel: NAC-04-102 NAC-04-102-D NAC-04-222 NAC-04-222-D NAC-04-332 NAC-04-332-D NAC-30-681-DXE NAC-30681-DXU NAC-30-472 NAC-30-472-D NAC-30-472-DXE NAC-30-472-DXU NAC-30-681 NAC-30-681-D NAC-30222-DXE NAC-30-222-DXU NAC-30-332 NAC-30-332-D NAC-30-332-DXE NAC-30-332-DXU NAC-30-102 NAC30-102-D NAC-30-102-DXE NAC-30-102-DXU NAC-30-222 NAC-30-222-D NAC-20-472-DXE NAC-20-472-DXU NAC-20-681 NAC-20-681-D NAC-20-681-DXE NAC-20-681-DXU NAC-20-332 NAC-20-332-D NAC-20-332-DXE NAC-20-332-DXU NAC-20-472 NAC-20-472-D NAC-20-102-DXE NAC-20-102-DXU NAC-20-222 NAC-20-222-D NAC-20-222-DXE NAC-20-222-DXU NAC-16-681 NAC-16-681-D NAC-16-681-DXE NAC-16-681-DXU NAC-20-102 NAC-20-102-D NAC-16-332-DXE NAC-16-332-DXU NAC-16-472 NAC-16-472-D NAC-16-472-DXE NAC-16-472DXU NAC-16-222 NAC-16-222-D NAC-16-222-DXE NAC-16-222-DXU NAC-16-332 NAC-16-332-D NAC-10-681DXE NAC-10-681-DXU NAC-16-102 NAC-16-102-D NAC-16-102-DXE NAC-16-102-DXU NAC-10-472 NAC-10472-D NAC-10-472-DXE NAC-10-472-DXU NAC-10-681 NAC-10-681-D NAC-10-222-DXE NAC-10-222-DXU NAC10-332 NAC-10-332-D NAC-10-332-DXE NAC-10-332-DXU NAC-10-102 NAC-10-102-D NAC-10-102-DXE NAC10-102-DXU NAC-10-222 NAC-10-222-D NAC-06-472-DXE NAC-06-472-DXU NAC-06-681 NAC-06-681-D NAC06-681-DXE NAC-06-681-DXU NAC-06-332 NAC-06-332-D NAC-06-332-DXE NAC-06-332-DXU NAC-06-472 NAC-06-472-D NAC-06-102-DXE NAC-06-102-DXU