58
Relay Coupler
59
Digital signal
processing
Relay Coupler
The universal foot of the Weidmüller relay
modules allow them to be assembled on
TS 32, TS 35 x 7.5 and TS 35 x 15
mounting rails in accordance with
European standards EN 50 035 and
EN 50 022.
An LED status indicator in the coil of the
relay coupler indicates the relay switching
status.
Types of contact
The standard range comprises numerous
types and combinations of contacts.
1 NC (EGR EG2, EGR EG7, RS 30)
1 NO (EGR EG2, EGR EG7, DKR,
RS 30)
1 NC and 1 NO
(EGR EG2, WRS)
2 NO (WRS)
3 NO (WRS)
1 Changeover
(EGR EG2, EGR/RST EG7,
WRS DKR PRS/PRZ MCZ R,
RS 30, RS 31)
2 Changeover
(EGR EG2, WRS, RS 32,
PRS/PRZ)
4/8/16 Changeover
(RSM)
Contact material
The all-round capability of Weidmüller relay
modules is achieved by the choice of the
contact material.
The contact is responsible for both the
reliable transmission of the control signals
and for switching power contactors.
Weidmüller uses gold-plated or gold-
flashed AgNi contacts for most applica-
tions. Gold-plated contacts permit
the switching of the low-power applica-
tions up to 40 µW with a gold-plating
thicker than 2 µm. For switching higher
ratings we use AgSnO2 or AgCdO con-
tacts (RS 31).
Contact material Properties Application U/I
Fine silver - inexpensive universal use 1 V…250 V
AG 99 % - average tendency to weld and average up to medium-size loads 1 mA…5 A
resistance to burn-off
- subject to corrosion in sulphurous atmosphere
Silver nickel - high mechanical stability universal use 12 V
AgNi 0.15 - low tendency to weld at medium-size loads 5 mA…10 A
- low contact resistance
- high resistance to burn-off
Hard silver - mechanical stability > AgNi for use with medium-size 12 V
AgCu3 - tendency to weld < AgNi loads 10 mA…10 A
- resistance to burn-off > AgNi
- contact resistance > AgNi
Silver cadmium - very low tendency to weld suitable for switching 12 V
oxide - resistance to burn-off > AgCu3/Ni inductive loads 100 mA
AgCdO
Silver-tin- - high thermal decomposition temperature suitable for swiching 12 V
oxide - more arc-resistant with low material transfer inductive loads 100 mA
AgSnO2
Tungsten - very high resistance to burn-off circuits with extremely 60 V
W- high switching rate with short closed times high on/off loads 1 A
Hard gold - < lowest contact resistance dry circuits in µV…60 V
AuNi - best resistance to corrosion damp atmospheres µA…0.2 V
= preferred materials
60
Relay Coupler
Switching of small and large power
ratings
For automation technology, Weidmüller
offers the EGR EGR 7 relay coupler to
switch ratings up to 40 µW under resistive
loads. This allows signals to be reliably
relayed to control devices.
The switching of higher power ratings in
power supply technology is achieved by
the RS 31 relay coupler, which guarantees
switching capacity up to 3.5 kVA under
resistive loads.
Switching times of the relay modules
pick-up delay typ. < 10 ms
drop-out delay typ. < 12 ms
Switching behaviour/load limit curve
(dependimg on type)
Contact life
with resistive load
DC-limit
with resistive load
Reduction factor
with inductive load cos j < 1
Switching no. eff.
= switching no (at cos j = 1) x red. Factor F
Relay couplers with plugged relays
Relay couplers with plugged relays are
only conditionally suitable for use in appli-
cations subject to heavy vibrations. Relay
couplers with soldered relays are to be
preferred.
Derating curves
The contact resistance is largely responsi-
ble for heat development within the relay.
This link is demonstrated by a derating
curve as a function of the permissible cur-
rent subject to the ambient temperature.
We determine the current (curve a) for the
following operating conditions:
- continuous operation
- rated input voltage + 10 %
- several relay modules operating under
load, mounted horizontally in a row
without spacing on mounting rail
A higher load is applicable when modules
are mounted with a gap of 20 mm as
shown in curve "b". In addition, the func-
tion of curve "b" shows the max. values
for a switching or short-time operation
when assembled horizontally on the
mounting rail.
Notes for usage
The characteristic data of the actuation
are to be meticulously observed when
using UC variants in DC circuitry. UC vari-
ants have a higher current input at the
moment of switching due to their series
circuitry. The internal current limiter of
commercially available initiators can result
in the operated relay coupler not being
switched through.
RC combination
Long supply cables are particularly open
to electrical and electro-mechanical influ-
ences. These can lead to disturbances of
the function or even failure of the relay
module. A remedy for this problem is an
RC combination in series that filters out
unwanted disturbances. RC combinations
are available for all customary relay cou-
plers: pluggable (PLUGSERIES) or as ter-
minal block (WDU 12C and DKU 12C).
Protective circuits of the contacts
Switching sparks may occur when switch-
ing inductive or capacitive loads that affect
the operational life of the relay.
The following protective circuits offer the
possibility of reducing contact wear:
Diode:
Advantage: can be used for all ratings, low
overvoltage, minimum space require-
ments, economic
Disadvantage: very long drop-out delay
Diode and Z-diode:
Advantage: low overvoltage (determined by Z-
diode), low drop-out delay
Disadvantage: not usable for high power ratings
RC combination:
Advantage: low overvoltage, low drop-out delay
Disadvantage: higher current loading on contacts at
switch-on, complex and expensive for
increased power rating
Varistor:
Advantage: low drop-out delay, economic
Disadvantage: not for all operating voltages and
power ratings
USVoltage curve
1Close
2Open
UVDR
Last
+
(~)
(~)
VDR
US
12 t
URC
Last
+
(~)
(~) R
C
US
12 t
UZD
Last
+
US
12 t
UD
Last
+
US
12 t
Single contact
Number of operations
Switching capacity (kVA)
Direct current (A)
Direct Voltage (V)
Reduction factor F
Load
Load
Load
Load
Power factor
61
Digital signal
processing
Definition of Technical Data
Protective separation
All equipment required to guarantee "pro-
tective separation" must be constructed in
such a way that, for example, a mechani-
cal defect cannot reduce the level of insu-
lation. In the case of a relay, this means
that if a mechanical defect occurs (bent
solder pin, break in winding conductor or
broken spring), "protective separation"
must be guaranteed.
Relays are specified and tested according
to IEC 255 and VDE 0435. Neither stan-
dard contains any reference to
EN 50 178 (Equipping power installations
with electronic equipment) nor is "protec-
tive separation" defined. To compound
matters the test voltages quoted for the
relays are based on different measurement
conditions. The test voltages cannot be
applied to EN 50 178 or DIN VDE 0106
Part 101. As more and more users employ
only equipment that guarantees "protec-
tive separation", a lot of manufacturers of
relays refer to DIN VDE 0106 and test their
products accordingly. Consequently, the
quoted values correspond to the require-
ments for "protective separation".
Standards
The following standards are fulfilled:
EN 50 178
Equipping power installations with elec-
tronic equipment
DIN VDE 0106 Part 101
Protection against flow of dangerous cur-
rents through the human body; basic
requirements for protective separation
within electrical equipment.
DIN VDE 0109
Insulation co-ordination within low-voltage
system including clearance and creepage
distances for assembled PCBs.
DIN VDE 0435
Electrical relays, all-or-nothing relays
Input circuit
Input voltage [V] Reference voltage at which the relay coupler operates.
Typical reference voltages:
=> 5 V DC, 12, 24, 48, 60, 115, 230 V AC/DC
Input current [mA] Quotient resulting from input voltage and input resistance.
Input resistance
=> coil resistance + resistance of drive (R, LED, rect. …)
Rated power consumption [W/VA] Input voltage x input current AC/DC
with tolerance of +/- 10% or +5/-15%
Typical range for relay coupler:
250 mW > Pv > 1 W 0.4 VA > Pv > 1.2 VA
Pull-in voltage [V] Smallest input voltage that relay coupler requires
in order to respond
(Tamb = 293 K)
Pick-up current [mA] Smallest input current required to switch relay
from inoperative to operating position
(Tamb = 293 K)
Pull-in power [W/VA] Product of pull-in voltage and pick-up current
Drop-out voltage [V] Voltage level at which relay has definitely released
Self reset current [mA] Input current level at which relay has definitely released
Output circuit
Output voltage [V] Max. voltage that can be applied to relay contact
Switching current [A] Current that can flow for max. of 4 sec.
after relay contact has closed
Continuous current [A] Current that flows continuously after contact has closed
Switching power [W/VA] Product of output voltage and switching current
with resistive, inductive and capacitive load
Min. switching power [mW] Smallest amount of power that can be
switched via contact
Service life Number of switching operations before contact fails
- mechanical => with no electric load
- electrical => with resistive or inductive AC/DC load
Pick-up lag [ms] Length of time from application of energizing voltage
until contact closes/opens
Drop-out lag [ms] Length of time from breaking the energizing circuit
until contact closes/opens
Contact bounce time [ms] Length of time between first and last closing/opening
of contact when relay picks up or drops out
Switching frequency [Hz] Switching operations per sec.
with a duty factor of 1 : 2 (ton = toff)
Withstand voltage [kV] Max. test voltage between input and output circuits
which does not cause any discharge
Reliable separation Feature of relay coupler that conform
to VDE 0160 and VDE 0106 Part 101
Electric arc Current flow between contact surfaces
as they open, caused by ionization
Contact wear Switching inductive loads leads to considerable
changes in the composition of the materials used.
The results are:
=> formation of pits or peaks on the surface of contacts
=> failure due to interlocking of contacts
Spark absorption Limitation of transient overvoltages by connecting
supplementary circuit across inductive loads
=> RC combinations
=> Z-diodes/suppressor diodes
=> varistors
Reduction factor Factor by which service life is reduced
when switching inductive loads
62
Types of Housings for Relay Coupler
Component housing EG
Weidmüller coupling modules are enclosed
in housings appropriate for industrial appli-
cations. The housings are suitable for fit-
ting onto mounting rails TS 32, TS 35 x
7.5 or TS 35 x 15 in accordance with
European standards EN 50 035 and EN
50 022.
Weidmüller component housings EG 1
and EG 2 are 18 mm wide.
The fully enclosed EG housings are
equipped with clamping yoke screw con-
nections or push-on connections to con-
nect conductors. Conductors with the fol-
lowing cross-sections can be connected:
solid core: 0.5...4 mm2or
flexible: 0.5...2.5 mm2.
The component housing EG 7 has a spe-
cial status. It has been specifically
designed to accommodate 10-mm slim
relays and optocouplers.
EG 7 relay couplers can be optionally
mounted onto TS 32 or TS 35 rails.
The RST EG 7 locking socket is also avail-
able for use with the pluggable relays cou-
plers.
The enclosed EG 7 housing are equipped
with clamping yoke screw connections.
The following conductor cross-sections
can be connected:
NO/NC: 0.5...1.5 mm2
Changeover (RST): 0.5...2.5 mm2.
Component housing WAVEBOX
It is important to provide modern electron-
ics components with housings suitable for
the function. Setting and operating func-
tions must be guaranteed; technical
requirements with respect to heat dissipa-
tion and EMC properties are to be sup-
ported.
An ideal design saves space and wiring
costs in the switchgear cabinet. In addi-
tion, ergonomics and design are becoming
increasingly important for high-quality relay
coupler interfaces.
The WAVEBOX fulfils these criteria and is
further distinguished by the following:
Optimal width for any application
(12.5 mm, 17.5 mm, 22.5 mm)
Large component assembly surface;
SMDs mountable on solder side
No tools required for assembly
Pluggable PCBs
Pluggable cross-connection
via ZQV 2.5 N
Hinged, transparent cover
Screw/plug and socket connector
BLZ 5.08
Optional tension clamp/plug and socket
connector BLFZ 5.08
Marking option with WS tags
Mount onto TS 35
Connection systems
BLZ screw/plug-in connectors and BLZF
tension clamp/plug-in systems for flexible
conductors up to 2.5 mm2, to guarantee
maximum wiring flexibility.
Removing printed circuit boards
Accomplished by depressing the locking
clips at the side of the headpiece, and
withdrawing the terminal level and PCB
from the housing. This is not permitted
when the supply is connected.
Cross-connection
The ZQV 2.5 N/2 cross-connector can
connect housings of the same family at
the base of the housing. The cross-con-
nection can be loaded with a current of up
to 8 A. This allows the supply voltage to
be cross-connected from one electronics
module to another.
The voltage at the cross-connection must
not exceed 50 V.
Ventilation vents
Ventilation vents, arranged at an angle,
temper and ventilate the lower side of the
housings.
Modular system
PLUGSERIES/PLUGRELAY
is a new generation of pluggable relay
couplers. The core of this system is an
innovative relay socket PXS or PXZ.
Weidmüller has combined the functionality
and experience from its relay and terminal
block business in this product.
The PLUGRELAY is the ideal connection
technology between the relay and the
application.
Modular system principle
The PLUGSERIES is particularly service
friendly.
Commercially available relays are plugged;
retainer and release clips ensure stability,
LED indicators with free-wheeling diodes
can be easily plugged.
Relays can be easily plugged
-suitable for small electric circuits
standard design and BGD
Independent connection technology:
screw or tension clamp rated
cross-section 0.5...2.5 mm2
Robust design of retainer / release clip
One or two changeover contacts Max.
current switched 16 A
Low wiring costs thanks to ZQV 25N
cross-connectors (pluggable)
Service-friendly modular system
-relay socket, LED indicators,
retainer clips and relays
-mount onto TS 35
-marking options with WS markers
on retainer clips
Pluggable LED indicator with
free-wheeling diode
63
Digital signal
processing
Types of Housings for Relay Coupler
Weidmüller RS locking socket
Locking sockets with relays RS 30, 31,
32 are either 11.2 mm or 25 mm wide
depending on version. The open profile
makes the use of pluggable relays
possible.
Modules mounted onto the locking sock-
ets are provided with clamping yoke screw
connections or push-on connectors for
wiring conductors.
Conductors with the following cross-sec-
tions can be connected:
solid core: 0.5...4 mm2
flexible: 0.5...2.5 mm2.
Locking sockets with multiple
interfaces
RSM multiple interfaces can be optionally
assembled with 4, 8 or 16 relays.
To save wiring costs on the input side,
variants are offered with joint positive and
negative potentials.
The PCB connectors are provided with
clamping yoke screw connections for con-
ductors with the following cross-sections:
solid core: 0.5...4 mm2or
flexible: 0.5...2.5 mm2.
Some versions of the RSM coupler have
a male connector block available for
connecting pre-assembled cables on
the input side in accordance with
IEC 603-1/DIN 41 651.
Minicoupler DK
All DKR mini coupler components fulfil
demands for slimmest possible design.
The sensational width of only 6 mm is
achieved by using state-of-the-art surface
mountable components SMDs. 4 and 5
screw-connections are offered for 0.5...4
mm2conductor cross-sections. The mini
couplers offer a wide spectrum for cou-
pling digital sensor/actuator signals
between automation devices and the field
process. DKR relay couplers can receive
and standardise signals with varying volt-
ages from the field.
Miniconditioner MCZ
The 6-mm MCZ housing is one of the
slimmest of its kind. It has the following
distinguishing features:
-Z-spring reduces mounting costs
-integrated cross-connection options in
the input and outputs minimise wiring
costs
MCZR miniconditioner (relay coupler) are
available with 4 or 5 Z-spring connections.
The clampable conductor cross-section is
0.5...1.5 mm2.
MICROSERIES
The relay coupler and optocoupler variants
from the MICROSERIES are used in
applications in industrial automation to
isolate and couple digital input and output
signals. Their compact design means that
they are particularly suitable for use on
sub-distribution boards as well as in
switchgear cabinets where they help the
user to make optimum use of valuable
switching space. With its compact design,
the MICROSERIES elegantly combines
the functionality of the classic coupling
level and the terminal level.
6.1-mm mounting width
Pluggable cross-connections of four
potentials in the inputs and outputs
Proven cross-connection
system ZQV 4 N
Wide input voltage
spectrum from 5 ... 230 V
LED-indicator reverse-connect
protection free-wheeling diode
Housing material: WEMID
Flammability class: V0 in accordance
with UL 94
Innovative retaining and release system
Marking surfaces for fitting standard WS
12/6 markers
CE-marking
Weidmüller relay couplers are marked with
the CE symbol and comply with the
requirements of EN 50 081 Part 1 and EN
50 082 Part 2. They can therefore be used
for both industrial as well as for applica-
tions in residential, commercial and light
industry.
Appropriate ESD measures should be
taken during installation. If supply cables
are particularly long, overvoltage protec-
tion should be provided to prevent interfer-
ence from electrical disturbance in the
atmosphere.
24 V
Housing
EG 0133660000 0133560000 0160260000
Page 72 Page 72 Page 73
0536260000 0542660000 0123060000
Page 72 Page 72 Page 73
WAVESERIES 8275350000 8418240000 8418270000 8418330000 8418300000
WRS 8286280000 8418250000 8418280000 Page 79 8418310000
8416210000 Page 76 Page 77 8418320000
8418220000 Page 78
8418230000
Page 74
EG 7* 8216520000 8216530000 8216570000
8147120000 8147140000 8216560000
8092340000 8092350000 8216580000
Page 80 Page 80 Page 80
PLUGSERIES 8530621001 8530631001
PRS / PRZ 8530691001 8530701001
8536530000 8536560000
8536650000 8536680000
Page 82 Page 82
RS 30 1101661001 1100961001 1181511001
1101611001 1100911001 1181521001
1101621001 1100921001 1100260000
1101761001 1101061001 1100210000
1101711001 1101011001 1100220000
1101721001 1101021001 1100360000
Page 91 Page 91 Page 91
RS 31 1128361001
1128331001
1128311001
Page 92
RS 32 9406121001
9406221001
Page 94
RSM 1173461001 1113161001 1113261001
1113361001 1100061001 1100161001
1113461001 1113561001 1113761001
1112361001 1113661001 8018221001
1112761001 1107761001 1107861001
Page 97 1112661001 1113861001
1173561001 1113061001
Page 97 1173661001
Page 97
DKR 32 8016620000
8008110000
Page 70
DKR 35 8016610000 8181980000
8008170000 8181970000
Page 70 Page 71
8215620000
Page 71
DKR 35/32 9454910000
Page 71
MCZ R 8365980000
8442960000
8390590000
Page 68
MICROSERIES 8533640000
MRS / MRZ 8533660000
8556050000
8556120000
Page 87
* Approval by Germanischer Lloyd
64
Relay Coupler
Output
2 x 2 x 4 x 8 x 16 x3 x
Electromechanical switching
Reliable
separation
24 V dc
24 Vuc/ac
48 V
Housing
EG 0662660000 0662460000 0160360000
Page 72 Page 72 0123260000
Page 73
WAVESERIES 8286280000 8418250000 8418280000 8418310000
WRS Page 74 Page 76 Page 77 Page 78
EG 7* 8092370000 8092380000 8216590000
Page 81 Page 81 Page 81
RS 30 1101861001 1101161001 1100460000
1101811001 1101111001 1100410000
1101821001 1101121001 1100420000
1101961001 1101261001 1100560000
1101911001 1101211001 Page 91
1101921001 1101221001
Page 91 Page 91
RS 31 1150761001
Page 92
RS 32 9406321001
Page 94
9406421001
1122661001
Page 95
RSM 1114061001 1114161001 1114361001
1113961001 1114261001 1114461001
1112461001 Page 97 Page 97
1173761001
Page 97
MICROSERIES 8556040000
MRS / MRZ 8556110000
Page 87
115 V
EG 0141360000
0160460000
Page 73
WAVESERIES 8418220000 8418260000 8418290000
WRS Page 75 Page 76 Page 77
EG 7* 8092430000 8092440000 8216610000
Page 81 Page 81 Page 81
PLUGSERIES 8536510000 8536520000
PRS / PRZ 8536610000 8536630000
8530640000 8530660000
8530790000 8530720000
Page 82 Page 82
RS 30 1155161001 1155211001
1155111001 1155261001
1155121001 1155221001
1102161001 1101461001
1102111001 1101411001
1102121001 1101421001
Page 91 Page 91
RS 31 1150361001
1150461001
Page 92
RS 32 1122761001
9406621001
Page 95
RSM 1114561001 1114661001 1114761001
Page 97 Page 97 Page 97
MCZ R 8420880000
8467470000
Page 61
MICROSERIES 8556030000
MRS / MRZ 8556100000
Page 87
* Approval by Germanischer Lloyd
65
Digital signal
processing
Relay Coupler
Output
Reliable
separation
Vdc
Vuc/ac
Electromechanical switching
2 x 2 x 4 x8 x16 x3 x
66
Relay Coupler
Output
Electromechanical switching
2 x 2 x 4 x 8 x 16 x3 x
Reliable
separation
230 Vuc/ac
230V
Housing
EG 0543860000 0543660000 0142460000
Page 72 Page 72 Page 73
WAVESERIES 8418230000 8418260000 8418290000 8418340000 8418320000
WRS Page 75 Page 76 Page 77 Page 79 Page 78
EG 7* 8092460000 8092470000 8216620000
8178200000 Page 81 8216630000
Page 81 Page 81
PLUGSERIES 8530671001 8530681001
PRS / PRZ 8530731001 8530741001
Page 82 Page 82
RS 30 1102261001 1101561001 1100860000
1102211001 1101511001 Page 91
1102221001 1101521001
Page 91 Page 91
RS 31 1128461001
1128431001
1128411001
Page 93
RS 32 9406721001
1122761001
Page 95
RSM 1114861001 1114961001 1115061001
1123461001 1108061001 1108261001
Page 97 Page 97 Page 97
MCZ R 8237710000
Page 69
MICROSERIES 8556020000
MRS / MRZ 8556090000
Page 87
240 V
RS 30 1128561001 1128661001
1128511001 1128611001
1128521001 1128621001
Page 91 Page 91
* Approval by Germanischer Lloyd
4…60 V
Housing
WAVESERIES 8275320000
WRS 2, 4…24 V Page 74
WAVESERIES 8418210000
WRS 60 V Page 74
EG 7*, 60 V 8092400000 8092410000 8216600000
Page 81 Page 81 Page 81
RS 30, 60 V 1102061001 1100660000 9406521001
1102011001 1100610000 Page 94
1102021001 1100620000
Page 91 Page 91
DKR 32, 5 V 8019600000
Page 70
DKR 35, 5 V 8019610000
Page 70
MCZ R, 60 V 8470380000
Page 68
MICROSERIES 8556080000
MRS / MRZ, 5 V 8556150000
Page 86
MICROSERIES 8556060000
MRS / MRZ, 60 V 8556130000
Page 87
* Approval by Germanischer Lloyd
67
Digital signal
processing
12 V
Housing
EG 0160160000
Page 73
WAVESERIES 8418240000 8418270000 8418300000
WRS Page 76 Page 77 Page 78
EG 7* 8092310000 8092320000 8216550000
Page 80 Page 80 Page 80
PLUGSERIES 8536471001 8536501001
PRS / PRZ 8536571001 8536591001
Page 82 Page 82
RS 30 1129421001 1129521001 1129660000
Page 91 Page 91 Page 91
RS 32 9406021001
Page 94
DKR 35 8171100000
Page 70
MICROSERIES 8556070000
MRS / MRZ 8556140000
Page 86
Relay Coupler
Output
Electromechanical switching
2 x 2 x 4 x8 x16 x3 x
Output
2 x 2 x 4 x8 x16 x3 x
Reliable
separation
Vdc
Vuc/ac
68
Ordering data
for TS 35
Technical data
Input
Input voltage
Input current at UN
Max. input power
Making threshold
Cut-out threshold
Reaction time at UN(typ.)
Release at UN(typ.)
Capacity working resistance to reduction at dissipated energy
Functionality
Cross-connection on pin
Output
Switching voltage
ac: continuous current/switching power (see derating diagram)
Min. switching current
Switch-on current
dc: Continuous current/switching power
Mechanical service life
Max. switching frequency at nominal load
Insulation coordination acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
Insulation coord.- and voltage proof, input/output mounting rail
Ambient temperature
Storage temperature
Conductor
Conductor cross-section
Approvals
Overall width
Accessories
End plate
Further accessories, dimensions and connection data see
Type Cat. No.
MCZ R 24 Vdc 8365980000
24 Vdc ±20 % (19.2...28.8 V)
6.3 mA ±10 % (5.7...6.9 mA)
156 mW ±10%
12 V...19 V
4 V...5.5 V
4.5 ms
10 ms
no
operating indication
reverse polarity protect. diode
free wheel diode
2, 3, 4
1 changeo. cont. (AgSnO2)
max. 300 Vdc / 400 Vac
max. 6 A / max. 1500 VA
100 mA (at U = 10 V)
max. 6 A
see limit diagram
20 x 106switching operations
0.1 Hz
300 V
4 kV
III
2
5.5 mm
4 kVeff / 1 min
-25 °C…+50 °C
-40 °C...+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA, GL
6 mm
Type Cat. No.
AP MCZ 1.5 8389030000
Page 305
Relay Couplers in Component Housings
This module can be used as a universal inter-
face between the controller and actuator for
switching medium-sized loads.
Reduces installation and commissioning
times by use of the proven Z-spring connec-
tion technology
Pluggable cross-connections in input and
output minimise wiring costs
6-mm width
MCZ R 24 Vdc MCZ R 24 Vdc/Au MCZ R 60 VdcMCZ R 24 Vac/dc
Type Cat. No.
MCZ R 24 Vac/dc 8390590000
24 Vac/dc ±10% (21.6...26.4 V)
ac:10.8 mA±15% (9.2…12.4 mA)
dc: 6.1 mA ±15% (5.2...7.1 mA)
ac: 160 mVA ±10 %
dc: 151 mW ±10 %
ac: ca. 17 V / dc: ca. 19 V
ac: ca. 7 V / dc: ca. 4 V
5 ms
30 ms
no
operating indication
bridge rectifier
2, 3, 4
1 changeo. cont. (AgSnO2)
max. 300 Vdc / 400 Vac
max. 6 A / max. 1500 VA
100 mA (at U = 10 V)
max. 6 A
see limit diagram
20 x 106switching operations
0.1 Hz
300 V
4 kV
III
2
5.5 mm
4 kVeff / 1 min
-25 °C…+50 °C
-40 °C...+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA, GL
6 mm
Type Cat. No.
AP MCZ 1.5 8389030000
Page 305
Schematic circuit diagram
300
200
100
25
6
5
4
3
2
1
20 25 30 35 40 45 50 °C
U/Vdc IL/A
prohibited area
1 2 3 4 5 6 IL/Adc
Derating curve
rowed without clearances on the mounting rail
rowed with 20 mm spacing on the mounting rail
Limit diagram
Type Cat. No.
MCZR24Vdc/Au8442960000
24 Vdc ±20 % (19.2...28.8 V)
6.3 mA ±10 % (5.7...6.9 mA)
156 mW ±10%
12 V...19 V
4 V...5.5 V
4.5 ms
10 ms
no
operating indication
reverse polarity protect. diode
free wheel diode
2, 3, 4
1 changeo. cont. (5 µ Au)
max. 300 Vdc / 400 Vac
max. 6 A* / max. 1500 VA
1) 0.1 mA
max. 6 A*
see limit diagram
20 x 106switching operations
0.1 Hz
300 V
4 kV
III
2
5.5 mm
4 kVeff / 1 min
-25 °C…+50 °C
-40 °C...+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA, GL
6 mm
Type Cat. No.
AP MCZ 1.5 8389030000
Page 305
Type Cat. No.
MCZ R 60 Vdc 8470380000
60 Vdc ±20% (48...72 V)
3 mA ±20 % (12.4...3.6 mA)
180 mW ±45 %
ca. 38 V
ca. 14 V
4.5 ms
10 ms
no
operating indication
reverse polarity protect. diode
free wheel diode
2, 3, 4
1 changeo. cont. (AgSnO2)
max. 300 Vdc / 400 Vac
max. 6 A / max. 1500 VA
100 mA (at U = 10 V)
max. 6 A
see limit diagram
20 x 106switching operations
0.1 Hz
300 V
4 kV
III
2
5.5 mm
4 kVeff / 1 min
-25 °C…+50 °C
-40 °C...+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type Cat. No.
AP MCZ 1.5 8389030000
Page 305
1) depends on load conditions
*the hard-gold plating is resistant for parameters 36 Vdc,
50 mA with 106cycles
Miniconditioners MCZ R
69
Digital signal
processing
MCZ R 110 Vdc MCZ R 120 Vac MCZ R 230 Vac
Type Cat. No.
MCZ R 230 Vac 8237710000
230 Vac ±10%
9.5 mA ±15 % (8...11mA)
2.1 VA ±15 %
ca. 115 V / 5 mA
ca. 60 V / 2.5 mA
8 ms
30 ms
no
operating indication
bridge rectifier
2.3, 4
1 changeo. cont. (AgSnO2)
max. 300 Vdc / 400 Vac
max. 6 A / max. 1500 VA
100 mA (at U = 10 V)
max. 6 A
see limit diagram
20 x 106switching operations
0.1 Hz
300 V
4 kV
III
2
5.5 mm
4 kVeff / 1 min
-25 °C…+50 °C
-40 °C...+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type Cat. No.
AP MCZ 1.5 8389030000
Page 305
Type Cat. No.
MCZ R 120 Vac 8420880000
120 Vac -15 %/+10 %
7 mA ±15 %
0.85 VA ±15 %
( 380 mW ± 15 %)
ca. 70 V / 4 mA
ca. 22 V / 1.3 mA
8 ms
30 ms
yes
operating indication
bridge rectifier
2.3, 4
1 changeo. cont. (AgSnO2)
max. 300 Vdc / 400 Vac
max. 6 mA / max. 1500 VA
100 mA (at U = 10 V)
max. 6 A
see limit diagram
20 x 106switching operations
0.1 Hz
300 V
4 kV
III
2
5.5 mm
4 kVeff / 1 min
-25 °C…+50 °C
-40 °C...+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type Cat. No.
AP MCZ 1.5 8389030000
Page 305
Type Cat. No.
MCZ R 110 Vdc 8467470000
110 Vdc ±10%
2.85 mA ±25%
340 mW ±25%
ca. 68 V / 1.6 mA
ca. 19 V / 0.4 mA
4.5 ms
10 ms
no
operating indication
bridge rectifier
2, 3, 4
1 changeo. cont. (AgSnO2)
max. 300 Vdc / 400 Vac
max. 6 A / max. 1500 VA
100 mA (at U = 10 V)
max. 6 A
see limit diagram
20 x 106switching operations
0.1 Hz
300 V
4 kV
III
2
5.5 mm
4 kVeff / 1 min
-25 °C…+50 °C
-40 °C...+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type Cat. No.
AP MCZ 1.5 8389030000
Page 305
300
200
100
25
6
5
4
3
2
1
20 25 30 35 40 45 50 °C
U/Vdc IL/A
prohibited area
1 2 3 4 5 6 IL/Adc
Derating curve
rowed without clearances on the mounting rail
rowed with 20 mm spacing
Limit diagram
Relay Couplers in Component Housings
Schematic circuit diagram
70
Type Cat. No.
DKR 5 Vdc 8019600000
DKR 5 Vdc 8019610000
Input: bottom
5 Vdc ±5 %
12.5 mA
65 mW
typ. 0.7…2.5 ms
typ. 0.2…2.0 ms
500 mA
10 W/10 VA
100 V
500 mA
200 Hz
RH/RU
1 normally-open contact
109switching operations
5x10
8switching operations
150 V
1.5 kV
III
2
3 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
Type Cat. No.
DKR 24 Vdc 8016620000
DKR 24 Vdc 8008170000
Input: bottom
24 Vdc ±20 %
9.3 mA
225 mW
typ. 0.7…2.5 ms
typ. 0.2…2.0 ms
500 mA
10 W/10 VA
100 V
500 mA
20 Hz
RH/RU
1 normally-open contact
109switching operations
5x10
8switching operations
150 V
1.5 kV
III
2
3 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
Relay Couplers in Component Housings Mini coupler DKR
DKR 12 Vdc DKR 24 Vac/dc DKR 24 Vdc
Type Cat. No.
DKR 12 Vdc 8171100000
Input: bottom
12 Vdc ±10 %
12 mA
144 mW
typ. 0.7…2.5 ms
typ. 0.2…2.0 ms
500 mA
10 W/10 VA
175 V
500 mA
25 Hz
RH/RU
1 normally-open contact
109switching operations
5x10
8switching operations
150 V
1.5 kV
III
2
3 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
Type Cat. No.
DKR 24 Vac/dc 8008110000
DKR 24 Vac/dc 8016610000
Input: bottom
24 Vac/dc ±20 %
11.5 mAac/9 mAdc
300 mVA/220 mW
0.6…4.5 ms ac/0.9…1.3 ms dc
12.7…25 ms ac/14.4…16.4 ms dc
500 mA
10 W/10 VA
170 V
500 mA
5 Hz
RH/RU
1 normally-open contact
109switching operations
5x10
8switching operations
150 V
1.5 kV
III
2
3 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
DKR 5 Vdc
Ordering data
for TS 32 Y
for TS 35 W
With combination foot TS 32/TS 35
Technical data
Input voltage
Input current
Input current, limited = SPS able
Input power
Pick-up lag
Turn off delay
Max. switch-on current
Max. switching capacity
Max. output voltage
Max. output current
Min. output current
Max. switching frequency
Contact material
Contacts
Service life mechanical
at lL= 10 mA
Insulation coordination acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
Operating temperature without clearance
with clearance
Storage temperature
Conductor
Conductor cross-section
Overall width
Accessories
End plate
Further accessories, dimensions and connection data see
These modules are used for
protective separation of input
signals and adjustment of sig-
nal levels
Cost-effective solution for
adjustment of power and
potential
Low input power
Screw connection technology
6-mm width
71
Digital signal
processing
Relay Couplers in Component Housings Mini coupler DKR
DKR 24 Vac/dc DKR 24 Vdc DKR 24 Vac/dcDK5R-1U
Type Cat. No.
DKR 24 Vdc 8181980000
Input: bottom
24 Vdc ±20 %
11.5 mA
384 mW
5 A
2 kVA/192 W
250 Vac/dc
8 A
100 mA
25 Hz
AgCdO
1 changeover contact
107 switching operations
3x10
6switching operations
300 V
6 kV
IV
2
8 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
18 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
Type Cat. No.
DKR 24 Vac/dc 8181970000
Input: bottom
24 Vac/dc ±20 %
20 mAac/16 mAdc
max. 100 mA
480 mWac/400 mWdc
5 A
2 kVA/192 W
250 Vac/dc
8 A
100 mA
ac: 5 Hz dc: 25 Hz
AgCdO
1 changeover contact
107switching operations
3x10
6switching operations
300 V
6 kV
IV
2
8 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
18 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
Type Cat. No.
DKR 24 Vdc 8215620000
Input: top
24 Vdc ±20 %
9.3 mA
225 mW
typ. 0.7…2.5 ms
typ. 0.2…2.0 ms
500 mA
10 W/10 VA
175 Vac/dc
500 mA
25 Hz
RH/RU
1 normally-open contact
109switching operations
5x10
8switching operations
150 V
1.5 kV
III
2
3 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
Type Cat. No.
DK5R-1U 9454910000
Input: bottom
24 Vac/dc ±20 %
9 mAac/7 mAdc
max. 240 mA
6 ms
15 ms ac/dc
4 A
1.5 kVA/140 W
250 Vac/dc
6 A
20 Hz
Ag Ni
1 changeover contact
2x107switching operations
300 V
4 kV
III
2
8 mm
-40 °C...+60 °C
-40 °C...+60 °C
-40 °C...+60 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DK5 8268870000
Page 305
72
Relay Coupler in Component Housings EG 2
EGR EG 2 24 V
AC/DC voltage
EGR EG 2 24 V
Direct and alternating voltage
EGR EG 2 48 V EGR EG 2 230 V
AC voltage
Ordering data
Rated data
Input voltage
Rated consumption – (W)
Rated consumption ~ (VA)
Drop-out current of the relay** (at 20 °C)
Max. output voltage
Continuous current
Derating curve
a = mounted horizontally on rail without clearance
b = mounted horizontally on rail with clearance x 20 mm
Continuous
current
Ambient temperature
Switch-on current
Max. switching capacity with resistor load
Min. switching capacity/switching current
Bounce times
Switching times, typical
–, pick-up lag
–, turn off delay
Max. switching frequency
Contact material
Service life, mechanical
–, 24 V–, 1 A, resistive load
–, 230 V~, 3 A, resistive load
Status indicator
Storage temperature
Ambient temperature
–, mounted on rail without clearance
–, mounted on rail with clearance 20 mm
Approvals
Insulation coordination acc. to EN 50178
Overvoltage category
Pollution severity
Accessories, dimensions and connection data see
** Larger values on request
Schematic circuit diagram
Type Cat. No.
NC 01335600001)
NO 01336600001)
24 V–, ±10 %
0.36 W
1.5 mA
240 V~/100 V–
3 A
5 A
600 VA/120 W
40 µW
< 2 ms
< 5.3 ms
< 8.3 ms
50 Hz
AgNi, gold-plated
> 107switching operations
> 6 x 105
switching operations
> 105 switching operations
Green LED
–40 °C…+60 °C
–25 °C…+40 °C
–25 °C…+50 °C
CSA (013366)
III
3
Page 306, Fig. II
Type Cat. No.
NC 0542660000
NO 0536260000
24 V0, ±10 %
0.35 W
0.6 VA
1.5 mA–/4 mA~
240 V~/100 V–
3 A
5 A
600 VA/120 W
40 µW
< 2 ms
< 8 ms
< 22 ms
30 Hz
AgNi, gold-plated
> 107switching operations
> 6 x 105
switching operations
> 105 switching operations
Green LED
–40 °C…+60 °C
–25 °C…+40 °C
–25 °C…+50 °C
III
3
Page 306, Fig. II
Type Cat. No.
NC 0662460000
NO 0662660000
48 V0, ±10 %
0.8 W
0.9 VA
1.5 mA–/3.5 mA~
240 V~/100 V–
1 A
5 A
600 VA/120 W
40 µW
< 2 ms
< 9 ms
< 12 ms
37 Hz
AgNi, gold-plated
> 107switching operations
> 6 x 105
switching operations
> 105switching operations
Green LED
–40 °C…+60 °C
–25 °C…+40 °C
–25 °C…+50 °C
III
2
Page 306, Fig. II
Type Cat. No.
NC 0543660000
NO 0543860000
230 V~, +5 % –15 %
3.2 VA
4 mA
240 V~/100 V–
1 A
5 A
600 VA/120 W
40 µW
< 2 ms
< 5 ms
< 7 ms
40 Hz
AgNi, gold-plated
> 107switching operations
> 6 x 105
switching operations
> 105switching operations
Green LED
–40 °C…+60 °C
–25 °C…+40 °C
–25 °C…+50 °C
III
2
Page 306, Fig. II
1) no output varistor
with 1 NO or 1 NC
Type Cat. No.
EGR 2 RT (24 V0)0123060000
EGR 2 RT (48 V0)0123260000
24 V048 V0
0.7 W 0.7 W
1 VA 0.9 VA
3.5 mA–/8 mA~
2 mA–/3.5 mA~
250 V
5 A
15 A/200 ms
1100 VA/144 W
5 A
4 ms
23 ms 18 ms
25 ms 19 ms
19 Hz 21 Hz
Ag, gold-flashed
30 x 106
105 (1100 VA, cos := 1)
Red LED
–40 °C…+85 °C
–25 °C…+40 °C
III
2
Page 306, Fig. III
73
Digital signal
processing
Ordering data
Rated data
Input voltage
Rated consumption – (W)
Rated consumption ~ (VA)
Drop-out current of the relay** (at 20 °C)
Max. output voltage
Continuous current
Derating curve
a = mounted horizontally on rail without clearance
b = mounted horizontally on rail with clearance x 20 mm
Continuous
current
Ambient temperature
Switch-on current
Max. switching capacity with resistor load
Min. braking capacity/switching current
Bounce times
Switching times, typical
–, pick-up lag
–, turn off delay
Max. switching frequency
Contact material
Service life, mechanical
–, 24 V–, 1 A, resistive load
–, 230 V~, 3 A, resistive load
Status indicator
Storage temperature
Ambient temperature
–, mounted on rail without clearance
–, mounted on rail with clearance 20 mm
Insulation coordination acc. to EN 50178
Overvoltage category
Pollution severity
Accessories, dimensions and connection data see
** Larger values on request
Schematic circuit diagram
Relay Coupler in Component Housings EG 2
EGR EG 2
DC voltage
2 changeover contacts
Type Cat. No.
EGR 2 RT (12 V–) 0160160000
EGR 2 RT (24 V–) 0160260000
12 V– 24 V–
0.61 W 0.54 W
––
12 mA 5.5 mA
250 V
5 A
15 A/200 ms
1100 VA/144 W
5 A
4 ms
16 ms 22 ms
20 ms 15 ms
20 Hz 20 Hz
Ag, gold-flashed
30 x 106
105(1100 VA, cos : = 1)
Red LED
–40 °C…+85 °C
–25 °C…+40 °C
III
2
Page 306, Fig. III
Type Cat. No.
EGR 2 RT (48 V–) 0160360000
EGR 2 RT (115 V–) 0160460000
48 V– 115 V–
0.65 W 0.6 W
––
2.5 mA 1 mA
250 V
5 A
15 A/200 ms
1100 VA/144 W
5 A
4 ms
18 ms 14 ms
16 ms 23 ms
27 Hz 24 Hz
Ag, gold-flashed
30 x 106
105 (1100 VA, cos := 1)
Red LED
–40 °C…+85 °C
–25 °C…+40 °C
III
2
Page 306, Fig. III
LED is parallel
to coil in 12 V DC
and 24 V DC
versions
Type Cat. No.
EGR 2 RT (115 V0)0141360000
EGR 2 RT (230 V0)0142460000
115 V0230 V0
0.6 W 1.2 W
0.6 VA 1.2 VA
1 mA–/1 mA~ 1 mA
250 V
5 A
014246
15 A/200 ms
1100 VA/144 W
5 A
4 ms
17 ms 13 ms
17 ms 18 ms
24 Hz 22 Hz
Ag, gold-flashed
30 x 106
105(1100 VA, cos := 1)
Red LED
–40 °C…+85 °C
–25 °C…+40 °C
III
2
Page 306, Fig. III
with 2.8-mm tab connection EGR EG 2
AC/DC voltage
2 changeover contacts
74
WRS 1 24/60 VUC
Type Cat. No.
WRS 1 24/60 Vuc
8418210000
WRZ 1
8430200000
24 Vuc±10% / 60 Vuc±10%
11 mAac±15% at Ue=60 V
10 mAdc±15% at Ue=60 V
10.2 mAac±15% at Ue=24 V
9 mAdc±15% at Ue=24 V
0.7 VA ±15% at Ue=60 V
0.34 VA±15% at Ue=24 V
0.6 W ±15% at Ue=60 V
0.22 W±15% at Ue=24 V
max. 150 Vdc/250 Vac
max. 5 A/max. 1250 VA*
max. 10 A
100 mA/5 Vdc
Ag-alloy
max. 30 m/max. 100 m
at 1 A / 6 Vdc
typ. 5.4 ms (NO) /
4.2 ms (NC)
typ. 4.4 ms (NO) /
5.4 ms (NC)
20 x 106 switching operations
150 x 103
switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
300 V
4 kV (1.2/50 µ)
III
2
5.5 mm
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
Type Cat. No.
WRS 1 2.4-24 Vdc
8275320000
WRZ 1
8430170000
2.4…24 Vdc +10 %
4.6 mAdc ±15% at Ue 12 V
6 mW ±15% at Ue 2.4 V
max. 150 Vdc /250 Vac
max. 5 A /max. 1250 VA*
max. 10 A
100 mA/5 Vdc
Ag-alloy
max. 30 m/max. 100 m
at 1 A/6 Vdc
typ. 7 ms (NO) /
4.5 ms (NC)
typ. 6.3 ms (NO) /
5.5 ms (NC)
20 x 106 switching operations
150 x 103
switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
300 V
4 kV (1.2/50 µ)
III
2
5.5 mm
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
WAVESERIES Relay Coupler in Component Housings
WRS 1 2.4-24 VDC WRS 1 24 VDC WRS 1 24/48 VUC
Schematic circuit diagram
Ordering data
Screw connection
Tension clamp connection
Input
Input voltage
Input current
Input power
Output
Switching voltage
Continuous current AC / Switching power AC
Switch-on current
Min. switching
Contact material
Contact resistance (when new)
Pick-up delay at nominal voltage
Turn off delay
Mechanical service life
Electrical service life
Max. switching frequency at nominal voltage
Ambient temperature
Storage temperature
Approvals
Insulation coordination acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Implemented clearance and creepage path
Insulation and voltage strength
Insulation and voltage strength of entire circuit to mounting rail
Testing
Input/output high voltage test
Accessories, dimensions and connection data see
* at ambient temperature 20°C
Type Cat. No.
WRS 1 24 Vdc
8275350000
WRZ 1
8430180000
24 Vdc±10 %
9 mAdc±15%
220 mW±15%
max. 150 Vdc /250 Vac
max. 5 A /max. 1250 VA*
max. 10 A
100 mA/5 Vdc
Ag-alloy
max. 30 m/max. 100 m
at 1 A/6 Vdc
typ. 7 ms (NO) /
4.5 ms (NC)
typ. 6.3 ms (NO) /
5.5 ms (NC)
20 x 106 switching operations
150 x 103
switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
300 V
4 kV (1.2/50 µ)
III
2
5.5 mm
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
Type Cat. No.
WRS 1 24/48 Vuc
8286280000
WRZ 1
8430190000
24 Vuc±10 % /48 Vuc±10%
14 mAuc±15% at Ue 24 V
14 mAuc±15% at Ue 48V
0.5 VA (W)±15% at Ue=48V
0.35 VA (W)±15% at Ue=24V
max. 150 Vdc /250 Vac
max. 5A /max. 1250 VA*
max. 10 A
100 mA/5Vdc
Ag-alloy
max. 30 m/max. 100 m
at 1 A/6 Vdc
typ. 7 ms (NO) /
4.5 ms (NC)
typ. 6.3 ms (NO) /
5.5 ms (NC)
20 x 106 switching operations
1.5 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
300 V
4 kV (1.2/50 µ)
III
2
5.5 mm
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
With 1 changeover contact
Relay couplers in the WAVEBOX
Independent connection technology
- pluggable connection unit
screw or tension clamp technology
Fast commissioning and after-sales-
service service
- pluggable PCBs
Save wiring tasks
- cross-connections possible at input
and output
75
Digital signal
processing
WRS 1 24/115 VUC WRS 1 24 VUC
230 VAC
Type Cat. No.
WRS 1 24/115 Vuc
8418220000
WRZ 1
8430210000
24 Vuc±10% / 115 Vuc±10%
11 mAac±15% at Ue=115 V
10.5mAdc±15% at Ue=115 V
10.2 mAac±15% at Ue=24 V
9 mAdc±15% at Ue=24 V
1.3 VA ±15% at Ue=115 V
0.34 VA±15% at Ue=24 V
1.2 W ±15% at Ue=115 V
0.22 W±15% at Ue=24 V
max. 150 Vdc/250 Vac
max. 5 A/max. 1250 VA*
max. 10 A
100 mA/5 Vdc
Ag-alloy
max. 30 m/max. 100 m
at 1 A / 6 Vdc
typ. 5.4 ms (NO) /
4.2 ms (NC)
typ. 4.4 ms (NO) /
5.4 ms (NC)
20 x 106 switching operations
150 x 103
switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
300 V
4 kV (1.2/50 µ)
III
2
5.5 mm
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
Type Cat. No.
WRS 1 24 Vuc/230 Vac
8418230000
WRZ 1
8430220000
24 Vuc±10% / 230 Vac±10%
15 mAac±15% at Ue=230 V
14 mAac±15% at Ue=24 V
13 mAdc±15% at Ue=24 V
3.5 VA ±15% at Ue=230 V
0.34 VA±15% at Ue=24 V
0.32 W±15% at Ue=24 V
max. 150 Vdc/250 Vac
max. 5 A/max. 1250 VA*
max. 10 A
100 mA/5 Vdc
Ag-alloy
max. 30 m/max. 100 m
at 1 A / 6 Vdc
typ. 5.4 ms (NO) /
4.2 ms (NC)
typ. 4.4 ms (NO) /
5.4 ms (NC)
20 x 106 switching operations
150 x 103
switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
300 V
4 kV (1.2/50 µ)
III
2
5.5 mm
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
WAVESERIES Relay Coupler in Component Housings
waagerecht montiert
Ansteuerung 26,4Vdc
0
1
2
3
4
5
6
7
8
020406080100
Umgebungstemperatur [°C]
A
bstand>=10mm
waagerecht montiert
Ansteuerung 52,8Vdc
0
1
2
3
4
5
6
7
8
020406080100
Umgebungstemperatur [°C]
A
bstand>=10mm
waagerecht montiert
Ansteuerung 66Vdc
0
1
2
3
4
5
6
7
8
020406080100
Umgebungstemperatur [°C]
A
bstand>=10mm
waagerecht montiert
Ansteuerung 26,4V ac / dc
0
1
2
3
4
5
6
7
8
020406080100
Umgebungstemperatur [°C]
A
bstand>=10mm
waagerecht montiert
Ansteuerung 253Vac
0
1
2
3
4
5
6
7
8
020406080100
Umgebungstemperatur [°C]
A
bstand>=10mm
WRS 1 24/60 VUC • 8418210000
WRS 1 24/115 VUC • 8418220000
WRS 1 24 VUC/230 VAC • 8418230000
WRS 1 2.4-24 VDC • 8275320000
WRS 1 24/48 VUC • 8286280000
Mounted horizontally
Control 26.4Vdc
mounted
clearance >= 10 mm
Ambient temperature [°C]
Output current [A]
Mounted horizontally
Control 52.8Vdc
mounted clearance >= 10 mm
Ambient temperature [°C]
Output current [A]
Mounted horizontally
Control 66Vdc
mounted clearance >= 10 mm
Ambient temperature [°C]
Output current [A]
Mounted horizontally
Control 26.4V ac/dc
mounted
clearance >= 10 mm
Ambient temperature [°C]
Output current [A]
Mounted horizontally
Control 253Vac
mounted
clearance >= 10 mm
Ambient temperature [°C]
Output current [A]
76
WAVESERIES Relay Coupler in Component Housings
WRS 2 12/24 VDC WRS 2 24/48 VUC
Ordering data
Screw connection
Tension clamp connection
Input
Input voltage
Input current
Input power
Output
Switching voltage
Continuous current AC / Switching power AC
Switch-on current
Min. switching
Contact material
Contact resistance (when new)
Pick-up delay at nominal voltage
Turn off delay
Mechanical service life
Electrical service life
Max. switching frequency at nominal voltage
Ambient temperature
Storage temperature
Approvals
Insulation coordination acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Implemented clearance and creepage path
Insulation and voltage strength
Insulation and voltage strength of entire circuit to mounting rail
Testing
Input/output high voltage test
Accessories, dimensions and connection data see
* at ambient temperature 20°C
Schematic circuit diagram
Type Cat. No.
WRS 2 12/24 Vdc
8418240000
WRZ 2 8430230000
12 Vdc±10 % / 24 Vdc±10 %
21 mAdc±15% at Ue=24 V
20 mAdc±15%bei Ue=12 V
0.5 W±15% at Ue=24 V
0.24 W±15% at Ue=12 V
max. 250 Vdc / 250 Vac
(UL –> 13300/12300)
max. 5 A / max. 1250 VA*
max. 8 A
100 mA / 5 Vdc
AgSnO2
max. 30 m/max. 100 m
at 1 A/6 Vdc
typ. 5 ms
typ. 6.3 ms (NO) /
5.5 ms (NC)
50 x 106 switching operations
1 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
300 V
4 kV (1.2/50 µ)
III
2
8 mm
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
Type Cat. No.
WRS 2 24/48 Vuc
8418250000
WRZ 2 8430240000
24 Vuc±10 % / 48 Vuc±10 %
10 mAac±15% at Ue=48 V
11.5 mAac±15% at Ue=24 V
8.5 mAdc±15% at Ue=48 V
7.2 mAdc±15% at Ue=24 V
0.48 VA±15% at Ue=48 V
0.21 VA±15% at Ue=24 V
0.4 W±15% at Ue=48 V
0.17 W±15% at Ue=24 V
max. 250 Vdc / 250 Vac
(UL –> 13300/12300)
max. 5 A / max. 1250 VA*
max. 8 A
100 mA / 5 Vdc
AgSnO2
max. 30 m/max. 100 m
at 1 A/6 Vdc
typ. 5 ms
---
50 x 106 switching operations
1 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
300 V
4 kV (1.2/50 µ)
III
2
8 mm
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
Type Cat. No.
WRS 2 115 Vuc/230 Vac
8418260000
WRZ 2 8430250000
115 Vuc±10%/ 230 Vac±10 %
11 mAac±15% at Ue=230 V
8.5 mAuc±15% at Ue=115 V
8 mAdc±15% at Ue=115 V
2.5 VA±15% at Ue=230 V
1 VA±15% at Ue=115 V
0.9 W±15% at Ue=115 V
max. 250 Vdc / 250 Vac
(UL –> 13300/12300)
max. 5 A / max. 1250 VA*
max. 8 A
100 mA / 5 Vdc
AgSnO2
max. 30 m/max. 100 m
at 1 A/6 Vdc
---
---
50 x 106 switching operations
1 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA (nur 115 Vuc)
300 V
4 kV (1.2/50 µ)
III
2
8 mm
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
WRS 2 115 VUC/
230 VAC
with 2 NO contacts
WRS 2 12/24 VDC -> 8418240000
waagerecht montiert
Ansteuerung 26,4Vdc
Umgebungstemperatur [°C]
A
bstand>=10mm
angereiht
WRS 2 24/48 VUC -> 8418250000
waagerecht montiert
Ansteuerung 52,8Vdc
Umgebungstemperatur [°C]
A
bstand>=10mm
angereiht
WRS 2 115 VUC/ 230 VAC -> 8418260000
waagerecht montiert; Ansteuerung 253Vac
Umgebungstemperatur [°C]
A
bstand>=10mm
WRS 2 115 VUC/ 230 VAC • 8418260000
WRS 2 12/24 VDC • 8418240000
WRS 2 24/48 VUC • 8418250000
Output current [A]
Mounted horizontally
Control 26.4 Vdc 26.4 Vdc
Ambient temperature [°C]
Output current [A]
Mounted horizontally
Control 26.4 Vdc 52.8 Vdc
Ambient temperature [°C]
Output current [A]
Mounted horizontally
Control 26.4 Vdc 253 Vdc
Ambient temperature [°C]
mounted
mounted
mounted
clearance 10 mm
clearance 10 mm
clearance 10 mm
77
Digital signal
processing
WRS 2 12/24 VDC WRS 2 24/48 VUC WRS 2 115 VUC/
230 VAC
Ordering data
Screw connection
Tension clamp connection
Input
Input voltage
Input current
Input power
Output
Switching voltage
Continuous current AC / Switching power AC
Switch-on current
Min. switching
Contact material
Contact resistance (when new)
Pick-up delay at nominal voltage
Turn off delay
Mechanical service life
Electrical service life
Max. switching frequency at nominal voltage
Ambient temperature
Storage temperature
Approvals
Insulation coordination acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Implemented clearance and creepage path
Insulation and voltage strength
Insulation and voltage strength of entire circuit to mounting rail
Testing
Input/output high voltage test
Accessories, dimensions and connection data see
* at ambient temperature 20°C
Schematic circuit diagram
Type Cat. No.
WRS 2 12/24 Vdc
8418270000
WRZ 2 8430260000
12 Vdc±10% / 24 Vdc±10%
19.7 mAdc±15% at Ue=12 V
20.5 mAdc±15% at Ue=24 V
0.5 W±15% at Ue=24 V
0.24 W±15% at Ue=12 V
max. 250 Vdc/250 Vac
max. 5 A/max. 1250 VA*
max. 8 A
100 mA/5 V
AgSnO2
max. 30 m/max. 100 m
at 1 A/6 Vdc
typ. 5ms
---
50 x 106 switching operations
1 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
300 V
4 kV (1.2/50 µ)
III
2
8 mm
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
Type Cat. No.
WRS 2 24/48 Vuc
8418280000
WRZ 2 8430270000
24 Vuc±10 % / 48 Vuc±10 %
10 mAac±15% at Ue=48 V
11.5 mAac±15% at Ue=24 V
8.5 mAdc±15% at Ue=48 V
7.2 mAdc±15%bei Ue=24 V
0.48 VA±15% at Ue=48 V
0.21 VA±15% at Ue=24 V
0.4 W±15% at Ue=48 V
0.17 W±15% at Ue=24 V
max. 250 Vdc/250 Vac
max. 5 A/max. 1250 VA*
max. 8 A
100 mA/5 V
AgSnO2
max. 30 m/max. 100 m
at 1 A/6 Vdc
---
---
50 x 106 switching operations
1 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
300 V
4 kV (1.2/50 µ)
III
2
8 mm
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
Type Cat. No.
WRS 2 115 Vuc/230 Vac
8418290000
WRZ 2 8430280000
115 Vuc±10 %/230 Vac±10 %
11 mAac±15% at Ue=230 V
10 mAuc±15% at Ue=115 V
8 mAdc±15% at Ue=115 V
2.5 VA±15% at Ue=230 V
1 VA±15% at Ue=115 V
0.9 W±15% at Ue=115 V
max. 250 Vdc/250 Vac
max. 5 A/max. 1250 VA*
max. 8 A
100 mA/5 V
AgSnO2
max. 30 m/max. 100 m
at 1 A/6 Vdc
---
---
50 x 106 switching operations
1 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA (nur 115 Vuc)
300 V
4 kV (1.2/50 µ)
III
2
8 mm
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
WAVESERIES Relay Coupler in Component Housings
0
1
2
3
4
5
6
7
8
020406080100
A
bstand>=10mm
angereiht
with 1NC / 1 NO
WRS 2 24/48 VUC -> 8418280000
waagerecht montiert
Ansteuerung 52,8Vac
0
1
2
3
4
5
6
7
8
9
020406080100
Umgebungstemperatur [°C]
A
bstand>=10mm
angereiht
WRS 2 115 VUC/230 VAC -> 8418290000
waagerecht montiert; Ansteuerung 253Vac
0
1
2
3
4
5
6
7
8
020406080100
Umgebungstemperatur [°C]
A
bstand>=10mm
WRS 2 115 VUC/230 VAC • 8418290000
WRS 2 12/24 VDC • 8418270000
WRS 2 24/48 VUC • 8418280000
Ambient temperature [°C]
Output current [A]
Mounted horizontally
Control 26.4 Vdc 26.4 Vdc
Ambient temperature [°C]
Output current [A]
Mounted horizontally
Control 26.4 Vdc 52.8 Vdc
Ambient temperature [°C]
Output current [A]
Mounted horizontally
Control 26.4 Vdc 253 Vdc
Ambient temperature [°C]
mounted
mounted
mounted
clearance 10 mm
clearance 10 mm
clearance 10 mm
78
WAVESERIES Relay Coupler in Component Housings
WRS 2 12/24 VDC WRS 2 24/48 VUC WRS 2 24 VUC/
230 VAC
Ordering data
Screw connection
Tension clamp connection
Input
Input voltage
Input current
Input power
Output
Switching voltage
Continuous current AC / Switching power AC
Switch-on current
Min. switching
Contact material
Contact resistance (when new)
Pick-up delay at nominal voltage
Turn off delay
Mechanical service life
Electrical service life
Max. switching frequency at nominal voltage
Ambient temperature
Storage temperature
Approvals
Insulation coordination acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Implemented clearance and creepage path
Insulation and voltage strength
Insulation and voltage strength of entire circuit to mounting rail
Testing
Input/output high voltage test
Accessories, dimensions and connection data see
* at ambient temperature 20°C
Schematic circuit diagram
Type Cat. No.
WRS 2 12/24 Vdc
8418300000
WRZ 2 8430290000
12 Vdc±10% /24 Vdc±10 %
21 mAdc±15% at Ue=12 V
22 mAdc±15% at Ue=24 V
0.26 W±15% at Ue=12 V
0.53 W±15% at Ue=24 V
max. 150 Vdc /250 Vac
max. 5 A/max. 1250 VA*
max. 10 A
100 mA/5 Vdc
Ag-alloy
max. 30 m/ max. 100 m
at 1 A / 6 Vdc
typ. 6.5 ms (NO) /
4.5 ms (NC)
typ. 8 ms (NO) /
11 ms (NC)
20 x 106 switching operations
1.5 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
300 V
4 kV (1.2/50 µ)
III
2
5.5 mm
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
Type Cat. No.
WRS 2 24/48 Vuc
8418310000
WRZ 2 8430300000
24 Vuc±10% /48 Vuc±10 %
14 mAuc±15% at Ue=48 V
14 mAuc±15% at Ue=24 V
0.7 VA(W)±15% at Ue=48 V
0.35 VA(W)±15% at Ue=24 V
max. 150 Vdc /250 Vac
max. 5 A/max. 1250 VA*
max. 10 A
100 mA/5 Vdc
Ag-alloy
max. 30 m/ max. 100 m
at 1 A / 6 Vdc
typ. 6.5 ms (NO) /
4.5 ms (NC)
typ. 8 ms (NO)/
11 ms (NC)
20 x 106 switching operations
1.5 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
300 V
4 kV (1.2/50 µ)
III
2
5.5 mm
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
Type Cat. No.
WRS 2 24 VUC/230 Vac
8418320000
WRZ 2 8430310000
24 Vuc±10% /230 Vac±10%
15 mAac±15% at Ue=230 V
14 mAuc±15% at Ue=24 V
0.35 W±15% at Ue=24 V
3.45 VA ±15% at Ue=230 V
max. 150 Vdc /250 Vac
max. 5 A/max. 1250 VA*
max. 10 A
100 mA / 5 Vdc
Ag-alloy
max. 30 m/ max. 100 m
at 1 A / 6 Vdc
typ. 6 ms (NO)/4.2 ms
(NC)/Eingang: 24 Vuc/230 Vac
typ. 4.4 ms (NO)/
5.4 ms (NC)
20 x 106 switching operations
150 x 103
switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
300 V
4 kV (1.2/50 µ)
III
2
5.5 mm
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
with 2 changeover contacts
WRS 2 12/24 VDC 8418300000
waagerecht montiert
Ansteuerung 26,4Vdc
0
1
2
3
4
5
6
7
020406080100
Umgebungstemperatur [°C]
A
bstand>=10mm
angereiht
WRS 2 24/48 VUC 8418310000
waagerecht montiert
Ansteuerung 26,4Vac
0
1
2
3
4
5
6
7
8
020406080100
Umgebungstemperatur [°C]
A
bstand>=10mm
angereiht
WRS 2 24 VUC/ 230 VAC 8418320000
waagerecht montiert
Ansteuerung 253Vac
0
1
2
3
4
5
6
7
8
01020304050607080
Umgebungstemperatur [°C]
A
bstand>=10mm
WRS 2 24 VUC/ 230 VAC • 8418320000
WRS 2 12/24 VDC • 8418300000
WRS 2 24/48 VUC • 8418310000
Output current [A]
Mounted horizontally
Control 26.4 Vdc 26.4 Vdc
Ambient temperature [°C]
Output current [A]
Mounted horizontally
Control 26.4 Vdc 26.4 Vdc
Ambient temperature [°C]
Output current [A]
Mounted horizontally
Control 26.4 Vdc 253 Vdc
Ambient temperature [°C]
mounted
mounted
mounted
clearance 10 mm
clearance 10 mm
79
Digital signal
processing
WAVESERIES Relay Coupler in Component Housings
WRS 2 24 VUC WRS 2 230 VAC
Ordering data
Screw connection
Tension clamp connection
Input
Input voltage
Input current
Input power
Output
Switching voltage
Continuous current AC / Switching power AC
Switch-on current
Min. switching
Contact material
Contact resistance (when new)
Pick-up delay at nominal voltage
Turn off delay
Mechanical service life
Electrical service life
Max. switching frequency at nominal voltage
Ambient temperature
Storage temperature
Approvals
Insulation coordination acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Implemented clearance and creepage path
Insulation and voltage strength
Insulation and voltage strength of entire circuit to mounting rail
Testing
Input/output high voltage test
Accessories, dimensions and connection data see
* at ambient temperature 20°C
Schematic circuit diagram
Type Cat. No.
WRS 2 24 Vuc 8418330000
WRZ 2 8430320000
3fach 24 Vac ±10 %
10.5 mAac ±15 % at Unenn
(per channel)
0.3 VA ±15 % (per channel)
0.25 W ±15 %
max. 250 Vdc /250 Vac
max. 4 A/max. 1500 VA*
max. 6 A
12 V/10 mA
AgSnO2
max. 100 m
at 1 A/24 Vdc
typ. 5 ms
typ. 21 ms
20 x 106 switching operations
1 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
UL/CSA
300 V
4 kV (1.2/50 µ)
III
2
5.5 mm
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
Type Cat. No.
WRS 2 230 Vac 8418340000
WRZ 2 8430330000
3 x 230 Vac ±10 %
10.3 mAac ±15 % at Unenn
(per channel)
2.4 VA ±15 % (per channel)
max. 250 Vdc / 250 Vac
max. 4 A/max. 1500 VA*
max. 6 A
12 V/10 mA
AgSnO2
max. 100 m
at 1 A/24 Vdc
typ. 8 ms
typ.11 ms
20 x 106 switching operations
1 x 105 switching operations
0.1 Hz
-25 °C...+50 °C
-40 °C...+60 °C
300 V
4 kV (1.2/50 µ)
III
2
5.5 mm
4 kVeff 1 min
4 kVeff 1 s
Page 298 + 308
with 3 NO contacts
WRS 2 24 VUC 8418330000
waagerecht montiert; Ansteurung 26,4Vdc
0
1
2
3
4
5
6
7
020406080100
Umgebungstemperatur [°C]
A
bstand>=10mm
angereiht
WRS 2 230 VAC -> 8418340000
waagerecht montiert; Ansteuerung 253Vac
0
1
2
3
4
5
6
7
020406080100
°C]
A
bstand>=10mmangereiht
WRS 2 24 VUC • 8418330000
WRS 2 230 VAC • 8418340000
Output current [A]
Mounted horizontally
Control 26.4 Vdc 26.4 Vdc
Ambient temperature [°C]
Output current [A]
Mounted horizontally
Control 26.4 Vdc 253 Vdc
Ambient temperature [°C]
mounted
mounted
clearance 10 mm
clearance 10 mm
80
Relay Couplers in Components Housings EG 7
EGR EG 7
RST EG 7
RS EG 7
EGR EG 7
RST EG 7
RS EG 7
12 V024 V– 24 V– 24 V0
Type Cat. No.
EGR EG7 8092310000
EGR EG7 8092320000
EGR EG7 80923300001)
RST EG7 8216550000
RS EG7 8193830000
12 V0+15 % –10 %
320 mW +20 % –10 %
120 mA
3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
250 V
5 A
8 A
100 mW/10 mA
1 ms
AgNi 0.15 gold-flashed
1 ms
8 ms
6 ms
> 15 x 106
switching operations
2 x 106
switching operations
with free wheel diode
> 2 x 105
switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
DIN VDE 0106
8 kV
8 mm
III
2
QB 16/10.16 1650330000
Page 304
Type Cat. No.
EGR EG7 8216520000
EGR EG7 8216530000
EGR EG7 82182000001)
RST EG7 8216570000
RS EG7 8193830000
24 V– +15 % –10 %
280 mW +20 % –10 %
12 mA
3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
250 V
5 A
8 A
100 mW/10 mA
1 ms
AgNi 0.15 gold-flashed
1 ms
8 ms
6 ms
> 15 x 106
switching operations
2 x 106
switching operations
with free wheel diode
> 2 x 105
switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
DIN VDE 0106
8 kV
8 mm
III
2
QB 16/10.16 1650330000
Page 304
Type Cat. No.
EGR EG7 8147120000
EGR EG7 8147140000
EGR EG7 81600300001)
RST EG7 8216560000
RS EG7 8193830000
24 V– +15 % –10 %
280 mW +20 % –10 %
12 mA
3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
250 V
5 A
8 A
40 µW2)
1 ms
AgNi 0.15 5 µ Au
1 ms
8 ms
6 ms
> 15 x 106
switching operations
2 x 106
switching operations
with free wheel diode
> 2 x 105
switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
DIN VDE 0106
8 kV
8 mm
III
2
QB 16/10.16 1650330000
Page 304
Type Cat. No.
EGR EG7 8092340000
EGR EG7 8092350000
EGR EG7 80923600001)
RST EG7 8216580000
RS EG7 8193830000
24 V0+15 % –10 %
280 mW +20 % –10 %
240 mA
3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
250 V
5 A
8 A
100 mW/10 mA
1 ms
AgNi 0.15 gold-flashed
2.4 ms
11 ms
10 ms
> 15 x 106
switching operations
2 x 106
switching operations
with free wheel diode
> 2 x 105
switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
DIN VDE 0106
8 kV
8 mm
III
2
QB 16/10.16 1650330000
Page 304
2) The following ratings can safely be
switched:
a) 100 mV…60 V ac/dc/100 µA…300 mA
After switching higher powers (b…d)
lower powers (a) can no longer be switched.
b) 5 V… 24 V dc/10 mA… 1.2 A
c) 24 V ... 60 V dc/10 mA... 500 mA
d) 10 V…250 V ac/10 mA… 5 A
Schematic circuit diagram
Derating curve
a = mounted horizontally on rail without clearance
b = mounted horizontally on rail, rowed with clearances
Continuous
current
Ambient temperature
Ordering data
Combination foot for TS 15, TS 32, TS 35 1 NO
1 NC
EGR EG 7 spare relays, without connection unit
Plug-in relay-coupl., without engagem. socket, 1 changeo. cont.
Engage.socket f. plug-in relay coupler w. combin.foot TS 32, 35
Rated data of the coil
Input voltage
Rated consumption
Max. switch-on current
Combination foot for drop current
Connection – NO and NC
– changeover contacts
Rated data der Contacts
Max. output voltage
Continuous current
Max. switch-on current
Min. switching capacity/switching current
Bounce times
Contact material2)
Bounce times
Switching times
pick up delay
drop-out delay
Service life, mechanical
–, 24 V–, 1.1 A, inductive load
–, 230 V~, 5 A, resistive load
Status indicator
Storage temperature
Ambient temperature
Insulation coordination acc. to EN 50178
Safe isolation according to VDE 0106 part 101
Rated impulse voltage
Clearances and creepage distances
Overvoltage category
Pollution severity
Accessories
Cross-connection comb. 16fold
Accessories, dimensions and connection data see
1) Serves only as a spare part for NO and NC
Plugs on to locking socket RS EG 7
with combination foot TS 32, 35
Overall width: 10 mm
With combination foot for TS 15, TS 32
or TS 35
Versions with 12 V, 24 V and 48 V fulfil
protective separation in accordance
with VDE 0160, Part 101
All EGR EG 7 and RST EG 7 are
approved by Germanischer Lloyd.
Approval No. 35962 HH
81
Digital signal
processing
Relay Couplers in Components Housings EG 7
48 V060 V~ 115 V0230 V~ 230 V~
Type Cat. No.
EGR EG7 8092370000
EGR EG7 8092380000
EGR EG7 80923900001)
RST EG7 8216590000
RS EG7 8193830000
48 V0+15 % –10 %
280 mW +15 % –10 %
480 mA
3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
250 V
5 A
8 A
100 mW/10 mA
1 ms
AgNi 0.15 gold-flashed
2.5 ms
12 ms
10 ms
> 15 x 106
switching operations
2 x 106
switching operations
with free wheel diode
> 2 x 105
switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
DIN VDE 0106
8 kV
8 mm
III
2
QB 16/10.16 1650330000
Page 304
Type Cat. No.
EGR EG7 8092400000
EGR EG7 8092410000
EGR EG7 80924200001)
RST EG7 8216600000
RS EG7 8193830000
60 V0+15 % –10 %
280 mW +15 % –10 %
600 mA
3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
250 V
5 A
8 A
100 mW/10 mA
1 ms
AgNi 0.15 gold-flashed
3.8 ms
12 ms
10 ms
> 15 x 106
switching operations
2 x 106
switching operations
with free wheel diode
> 2 x 105
switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
8 kV
8 mm
III
2
QB 16/10.16 1650330000
Page 304
Type Cat. No.
EGR EG7 8092430000
EGR EG7 8092440000
EGR EG7 80924500001)
RST EG7 8216610000
RS EG7 8193830000
115 V0+15 % –10 %
330 mW +15 % –10 %
160 mA
3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
250 V
5 A
8 A
100 mW/10 mA
1 ms
AgNi 0.15 gold-flashed
3.8 ms
12 ms
10 ms
> 15 x 106
switching operations
2 x 106
switching operations
with free wheel diode
> 2 x 105
switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
8 kV
8 mm
III
2
QB 16/10.16 1650330000
Page 304
Type Cat. No.
EGR EG7 8092460000
EGR EG7 8092470000
EGR EG7 80924800001)
RST EG7 8216620000
RS EG7 8193830000
230 V~ +15 % –10 %
280 mW +15 % –10 %
185 mA
3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
250 V
5 A
8 A
100 mW/10 mA
1 ms
AgNi 0.15 gold-flashed
2 ms
12 ms
10 ms
> 15 x 106
switching operations
2 x 106
switching operations
with free wheel diode
> 2 x 105
switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
8 kV
8 mm
III
2
QB 16/10.16 1650330000
Page 304
Type Cat. No.
EGR EG7 8178200000
RST EG7 8216630000
RS EG7 8193830000
230 V~ +15 % –10 %
280 mW +15 % –10 %
185 mA
3 mA
Screw connection
0.5…1.5 mm2
AWG-Conductor 26…16
0.5…2.5 mm2
250 V
5 A
8 A
40 µW2)
1 ms
AgNi 0.15 5 µ Au
2 ms
12 ms
10 ms
> 15 x 106
switching operations
2 x 106
switching operations
with free wheel diode
> 2 x 105
switching operations
Green LED
–40 °C…+60 °C
–25 °C…+60 °C
8 kV
8 mm
III
2
QB 16/10.16 1650330000
Page 304
EGR EG 7
RST EG 7
RS EG 7
82
PLUGSERIES Relays on Sockets
Modular system comprising:
- Relay socket for mounting rails
- LED indicator unit / RC combination
- retainer clip
- pluggable relays
Independent connection technology:
screw or tension clamp technology
Compatible with low power relays type
RT / Standard with 1 or 2 CO contacts
Coil and root-contacts cross-con-
nectable with cross-connection type
ZQV 2.5 N
Available as complete module or as
spare parts
PRS/PRZ xxx 1CO PRS/PRZ xxx 2CO DC-Version AC-Version
PRZ/PRS PRZ/PRS
Type/Version
Screw connection
PRS 12Vdc LD 1CO
PRS 12Vdc LD 2CO
PRS 24Vdc LD 1CO
PRS 24Vdc LD 2CO
PRS 115Vdc LD 1CO
PRS 115Vdc LD 2CO
PRS 24Vdc LD 2CO SGR 282
with gold-plated
relay contacts:
PRS 24Vdc LD 2CO AU
Tension clamp connection
PRZ 12Vdc LD 1CO
PRZ 12Vdc LD 2CO
PRZ 24Vdc LD 1CO
PRZ 24Vdc LD 2CO
PRZ 115Vdc LD 1CO
PRZ 115Vdc LD 2CO
PRZ 24Vdc LD 2CO SGR 282
with gold-plated
relay contacts:
PRZ 24Vdc LD 2CO AU
Other variants on request
Technical data
Input voltage
Rated consumption, typ
Status indicator
Output
Contact version
Max. output voltage
Max. switching current
Continuous current
Rated braking capacity
Service life, mech.
Input/output
Clearance and creepage path
Protective separation
Dielectric strength
Insulation coordinates acc. to
EN 50178
Miscellaneous data
Ambient temperature
Protection class
Rated cross-section
Flammability
Relay type
Dimensions WxHxT
Approvals
Rail mounted
Accessories
Cross-connection
2-pole black
2-pole red
2-pole blue
Marking tags
Type/Version
Screw connection
PRS 24Vac LD 1CO
PRS 24Vac LD 2CO
PRS 120Vac LD 1CO
PRS 120Vac LD 2CO
PRS 230Vac LD 1CO
PRS 230Vac LD 2CO
with gold-plated
relay contacts:
PRS 120Vac LD 2CO AU
PRS 230Vac LD 2CO AU
Tension clamp connection
PRZ 24Vac LD 1CO
PRZ 24Vac LD 2CO
PRZ 120Vac LD 1CO
PRZ 120Vac LD 2CO
PRZ 230Vac LD 1CO
PRZ 230Vac LD 2CO
with gold-plated
relay contacts:
PRZ 120Vac LD 2CO AU
PRZ 230Vac LD 2CO AU
Other variants on request
Technical data
Input voltage
Rated consumption, typ
Status indicator
Output
Contact version
Max. output voltage
Max. switching current
Continuous current
Rated braking capacity
Service life, mech.
Input/output
Clearance and creepage path
Protective separation
Dielectric strength
Insulation coordinates acc. to
EN 50178
Miscellaneous data
Ambient temperature
Protection class
Rated cross-section 0.5 mm2
Flammability
Relay type
Dimensions WxHxT
Approvals
Rail mounted
Accessories
Cross-connection
2-pole black
2-pole red
2-pole blue
Marking tags
Cat. No. Qty.
8536471001 10
8536501001 10
8530621001 10
8530631001 10
8536510000 10
8536520000 10
8596000000 10
8561760000 10
8536571001 10
8536591001 10
8530691001 10
8530701001 10
8536610000 10
8536630000 10
8595970000 10
8552440000 10
12 V dc ... 24Vdc ... 115Vdc
400 mW
pluggable LED-housing,
green LED
1 CO /2 CO contacts
1 x UM / 2 x UM
250Vuc
16A / 2 x 8A
10A
4kVA / 2 x 2kVA
30 x 106
> 8mm
DIN VDE 0106 T. 101
> 4kV eff
III / 2
-40°C ... +50°C
IP 20
0.5...2.5mm2
V0
Schrack RT1 / RT2
15.2 x 91 x 85
CE, UL recognized, cUL
TS 35
ZQV 2.5N/4-2 SW1784270000 60
ZQV 2.5N/4-2 RT 1784280000 60
ZQV 2.5N/4-2 BL 1784290000 60
WS 10/5 1060860000
WS 15/5 1609880000
Cat. No. Qty.
8536530000 10
8536560000 10
8530641001 10
8530661001 10
8530671001 10
8530681001 10
8595960000 10
8595990000 10
8536651001 10
8536681001 10
8530710000 10
8530720000 10
8530731001 10
8530741001 10
8575940000 10
8575950000 10
24Vac ...120Vac ... 230Vac
760 VA
pluggable LED-housing,
green LED
1 CO /2 CO contacts
1 x UM / 2 x UM
250Vuc
16A / 2 x 8A
10A
4kVA / 2 x 2kVA
5 x 106
> 8mm
DIN VDE 0106 T. 101
> 4kV eff
III / 2
-40°C ... +50°C
IP 20
0.5...2.5mm2
V0
Schrack RT1 / RT2
15.2 x 91 x 85
CE, UL recognized, cUL
TS 35
ZQV 2.5N/4-2
SW
1784270000 60
ZQV 2.5N/4-2 RT 1784280000 60
ZQV 2.5N/4-2 BL 1784290000 60
WS 10/5 1060860000
WS 15/5 1609880000
Digital signal
processing
83
PLUGSERIES Relays on Sockets
Accessories
92
87
15,3
87 (PXZ35)
95 (PXS35) Cross-connections
channelA1 / A2
Cross-connection
channel
11 / 21
marking field
retaining-clip
92
15.3
A2 A2
A1
(COIL) A1
(COIL)
24 2414
(NO) 14
(NO)
21 2111
(COM) 11
(COM)
22 2212
(NC) 12
(NC)
15.3
Empty base for rail mounted TS 35
Screw connection
Tension clamp connection
Technical data
Rated current
Rated voltage
Dielectric strength coil/contacts
Protection class
Rated cross-section
Insulation stripping length
- Screw connection
- Tension clamp connection
Ambient temperature
Flammability class UL 94
Holding clamp
Operating indication
LED indicator with free-wheeling diode
6 ... 24 Vdc
6 ... 24 Vdc
48 ... 60 Vdc
115 Vdc
12 ... 24 Vac
115 Vac
230 Vac
230 Vac
RC combination 120...230 VAC/DC
Pluggable cross-connectionen
2-pole black
2-pole red
2-pole blue
Marking tags
10 x 5 mm
Type Cat. No. Qty.
PXS35 8533771001 10
PXZ35 8536691001 10
16 A
250 V
> 4 kV
IP 20
2.5 mm2
8 mm
10 mm
-40°C ... +60°C
V0
Type Cat. No. Qty.
PRC 8536700000 100
PLED 24 Vdc 8536710000 20
PLED 24 Vdc red 8611010000 20
PLED 48 Vdc 8536720000 20
PLED 115 Vdc 8536730000 20
PLED 24 Vac 8536750000 20
PLED 120 Vac 8536760000 20
PLED 230 Vac 8536780000 20
PLED 230 Vac red 8611000000 20
PLRC 200 nF/2008566530000 20
ZQV 2.5N/4-2SW 1784270000 60
ZQV 2.5N/4-2RT 1784280000 60
ZQV 2.5N/4-2BL 1784290000 60
Type Cat. No. Qty.
WS 10/5 1060860000 200
WS 15/5 1609880000 96
DC-Version
AC-Version
Tension
clamp Screw
connection
A2
A
114
21
24
12
11
22
A2
A
114
21
24
12
11
22
Operating indication
*free wheel
diode
*
84
PLUGSERIES Relays on Sockets
Type Schrack RT Cat. No. Qty.
RT 314012 4058470000 20
RT 424012 4058560000 20
RT 314024 4058480000 20
RT 315024 4058490000 20
RT 424024 4058570000 20
RT 425024 4058580000 20
RT 314048 4058740000 20
RT 424048 4058750000 20
RT 424060 4058760000 20
RT 314110 4058500000 20
RT 424110 4058590000 20
RT 315524 4058510000 20
RT 424524 4058600000 20
RT 314615 4058520000 20
RT 315625 4058530000 20
RT 424615 4058610000 20
RT 425615 4058620000 20
RT 314730 4058540000 20
RT 315730 4058550000 20
RT 424730 4058630000 20
RT 425730 4058640000 20
1 changeover contact or 2 changeover contacts
AgNi 90/10, AgNi 0.15 htv
16 A 1We/2 x 8 A 2We
250 V ac
4 kVA
10 mA /100 mW
40 µW
400 mW dc/0.55 VA ac
5 kV
typ. 7/3 ms
9/45 ms
typ. 1/3 ms
> 30 x 106switching operations
> 30 x 106switching operations
1.25A, L/R = 80 ms 2.3 x 105
1.25A, L/R = 80 ms 2.8 x 105
1.2A, cosL/R = 0.3 6050x
IP 40
V0
-40°C ... +85°C
-40°C ... +70°C
14 g
UL, CSA, VDE, ÖVE
SCHRACK RT
Pluggable relay types
Print figure/circuit diagram
Relay type RT/SGR
Pluggable relay
12 Vdc 1 changeover contact
12 Vdc 2 changeover contacts
24 Vdc 1 changeover contact
24 Vdc 1 changeover contact AU
24 Vdc 2 changeover contacts
24 Vdc 2 changeover contacts AU
48 Vdc 1 changeover contact
48 Vdc 2 changeover contacts
60 Vdc 2 changeover contacts
110 Vdc 1 changeover contact
110 Vdc 2 changeover contacts
24 Vac 1 changeover contact
24 Vac 2 changeover contacts
115 Vac 1 changeover contact
115 Vac 1 changeover contact AU
115 Vac 2 changeover contacts
115 Vac 2 changeover contacts AU
230 Vac 1 changeover contact
230 Vac 1 changeover contact AU
230 Vac 2 changeover contacts
230 Vac 2 changeover contacts AU
Technical data
Contact number and type
Contact material
Switching current
Switching voltage
Braking capacity
Min. switching current / braking capacity
Min. braking capacity AU contact
Rated consumption
Dielectric strength Sp./Kont.
Response / drop out time: DC coil
AC coil
Bounce time NO contact/normally closed contact
Mechanical service life: DC coil
AC coil
Braking capacity 1-pole DC 13
2-pole DC 13
2-pole AC 15
Miscellaneous data
Protection class
Flammability class UL
Ambient temperature DC coil
AC coil
Weight
Approvals
1 changeover contact
2 changeover contacts
Digital signal
processing
85
PLUGSERIES Relays on Sockets
Type ELESTA SGR Cat. No. Qty.
SGR 662 24 Vdc T 8550510000 10
SGR 282 24 Vdc T 8550520000 10
2 changeover contacts with test button
AgCuNi
16 A 1We/2 x 8 A 2We
250 Vac
4 kVA
10 mA /100 mW
500 mW
5 kV
typ. 10/3 ms
typ. 0.5/5 ms
> 30 x 106switching operations
IP 40
V1
-25°C ... +70°C
20 g
SEV, UL, CSA, DEMKO, VDE, PTB
Pluggable relay
24 Vdc 1 changeover contact with test button
24 Vdc 2 changeover contacts with test button
24 Vdc 1 normally-open contact
Technical data
Contact number and type
Contact material
Switching current
Peak inrush current
Switching voltage
Braking capacity
Min. switching current / braking capacity
Rated consumption
Dielectric strength Sp./Kont.
Response / drop out time: DC coil
Bounce time NO contact/normally closed contact
Mechanical service life: DC coil
Miscellaneous data
Protection class
Flammability class UL
Ambient temperature DC coil
Weight
Approvals
ELESTA SGR
Relais with manual operation
Type Schrack RP 3SL Cat. No. Qty.
RP3SL 24 Vdc 1NO 8588510000 20
1 normally-open contact
AgSnO2
25 A
120 A / 20 ms
250 V
4 kVA
500 mW
4 kV
typ. 8/2 ms
typ. 2 ms
30 x 106switching operations
IP 40
-40°C ... +70°C
18 g
SEV, UL, CSA, VDE
Contact service life
Type Load switch. oper. Regulation
RP3SL 12 A, 250 V~, cosϕ=1 3x105
RP3SL TV 8 25x103UL 508
RP3SL 2500 W, 230 V~,
halogene lamps
>104
RP3SL 1000 W, 250 V~,
glow lamps
2.3x105
RP3SL 3000 W, 250 V~,
glow lamps
3.6x104
RP3SL 1500 VA,
flurescent tubes
163 µF 104
RP 3SL
Relays for high switching currents
Leistungsrelais Type RT2
2 changeover contacts Power relay RP 3SL
Electrical life
Operations
86
Ordering data
for TS 35
Screw connection
Tension clamp connection
Technical data
Input
Input voltage
Input voltage ac with UNenn
Input voltage dc with UNenn
Input power
Making threshold , (typ.)
Cut-out threshold (typ.)
Status indicator
Reaction time at UN(typ.)
Release at UN(typ.)
Voltage of relay coil
Functionality
Operating indication
Reverse polarity protection
Free wheel diode
Output
Switching voltage
ac: continuous current/switching power (see derating diagram)
Switch-on current
dc: Continuous current/switching power
Min. braking capacity
Contact material
Mechanical service life
Max. switching frequency at nominal voltage
Ambient temperature
Storage temperature
Climate
Approvals
Insulation coordination acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Insulation coord.- and voltage proof, input/output mounting rail
Achieved clearances and creepage distances
Type Cat. No.
MRS 5 Vdc 1CO 8556080000
MRZ 5 Vdc 1CO 8556150000
5 Vdc ± 20 % (4...6 V)
38 .5 mAdc ±10 %
193 mW ±10%
3.2 V / 21.6 mA
1.6 V / 8 mA
Green LED
6.2 ms
3.9 ms
5 V
yes
yes
yes
1 changeover contact
250 Vac acc. to VDE
240 Vac acc. to UL/CSA
max. 6 A / max. 1500 VA
max. 6 A
see limit diagram
12 V /10 mA
AgSnO
20 x 10 6 switching operations
0.1 Hz
-25 °C…+50 °C
-40 °C…+60 °C
40 °C / 93 % rel. humidity,
no condensation
CE, cUL
300 V
4 kV (1.2 / 50 µs)
III
2
4 kVeff / 1 min
5.5 mm
This module can be used as a universal
interface between the controller and actuator
for switching small to medium-sized loads.
Pluggable cross-connection in the input
and output reduces wiring costs
6-mm width
Flexible thanks to screw and tension
clamp connection versions
MRS 5 Vdc 1CO
MRZ 5 Vdc 1CO
MRS 12 Vdc 1CO
MRZ 12 Vdc 1CO
Schematic circuit diagram
Type Cat. No.
MRS 12 Vdc 1CO 8556070000
MRZ 12 Vdc 1CO 8556140000
12 Vdc ±20 % (9.6...14.4 V)
17.2 mAdc ±10 %
210 mW ±10%
6.4 V / 8.4 mA
2.5 V / 2.4 mA
Green LED
5.8 ms
6.9ms
12 V
yes
yes
yes
1 changeover contact
250 Vac acc. to VDE
240 Vac acc. to UL/CSA
max. 6 A / max. 1500 VA
max. 6 A
see limit diagram
12 V /10 mA
AgSnO
20 x 10 6 switching operations
0.1 Hz
-25 °C…+50 °C
-40 °C…+60 °C
40 °C / 93 % rel. humidity,
no condensation
CE, cUL
300 V
4 kV
III
2
4 kVeff / 1 min
5.5 mm
MICRORELAY
MRS/MRZ
Current temperature-rise curve
Limit diagram
Output current [A]
Ambient temperature [°C]
Relay Couplers on Sockets MICROSERIES in Terminal Format
Digital signal
processing
87
MRS 48 Vuc 1CO
MRZ 48 Vuc 1CO
MRS 60 Vdc 1CO
MRZ 60 Vdc 1CO
MRS 120 Vuc 1CO
MRZ 120 Vuc 1CO
MRS 230 Vac 1CO
MRZ 230 Vac 1CO
Type Cat. No.
MRS 120 Vuc 1CO 8556030000
MRZ 120 Vuc 1CO 8556100000
120 Vuc +10% / -15% (102...132 V)
3.5 mAac ±15 %
0.42 VA ±15 %
71 V / 1.8 mA
22 V / 0.5 mA
Green LED
6.7 ms
8.1 ms
60 V
yes
yes
yes
1 changeover contact
250 V ~ acc. to VDE
240 V ~ acc. to UL/CSA
max. 6 A / max. 1500 VA
max. 6 A
see limit diagram
12 V /10 mA
AgSnO
20 x 10 6 switching operations
0.1 Hz
-25 °C…+50 °C
-40 °C…+60 °C
40 °C / 93 % rel. humidity,
no condensation
CE, cUL
300 V
4 kV
III
2
4 kVeff / 1 min
5.5 mm
Type Cat. No.
MRS 230 Vac1CO8556020000
MRZ 230Vac1CO 8556090000
230 Vac ±10% (207...253 V)
7.6 mA ±15%
1.55 VA ±15 %
103 V / 5 mA
49 V / 2.5 mA
Green LED
13 ms
11 ms
24 V
yes
1 changeover contact
250 V ~ acc. to VDE
240 V ~ acc. to UL/CSA
max. 6 A / max. 1500 VA
max. 6 A
see limit diagram
12 V /10 mA
AgSnO
20 x 10 6 switching operations
0.1 Hz
-25 °C…+50 °C
-40 °C…+60 °C
40 °C / 93 % rel. humidity,
no condensation
CE, cUL
300 V
4 kV
III
2
4 kVeff / 1 min
5.5 mm
Type Cat. No.
MRS 60 Vdc1CO 8556060000
MRZ 60 Vdc1CO 8556130000
60 Vdc ±20% (48...72 V)
3.3 mAdc ±20 %
200 mW ±10 %
35 V / 1.6 mA
11 V / 0.6 mA
Green LED
5.9 ms
6.5 ms
60 V
yes
yes
yes
1 changeover contact
250 Vac acc. to VDE
240 Vac acc. to UL/CSA
max. 6 A / max. 1500 VA
max. 6 A
see limit diagram
12 V /10 mA
AgSnO
20 x 10 6 switching operations
0.1 Hz
-25 °C…+50 °C
-40 °C…+60 °C
40 °C / 93 % rel. humidity,
no condensation
CE, cUL
300 V
4 kV
III
2
4 kVeff / 1 min
5.5 mm
Type Cat. No.
MRS 48 Vuc1CO 8556040000
MRZ 48 Vuc1CO 8556110000
48 Vuc ±10% (43.2...52.8 V)
5mA ±20 %
4mA ±20 %
190 mW ±20 %
29 V / 2.2 mA
11 V / 1.3 mA
Green LED
6.1 ms
5.8 ms
48 V
yes
yes
yes
1 changeover contact
250 Vac acc. to VDE
240 Vac acc. to UL/CSA
max. 6 A / max. 1500 VA
max. 6 A
see limit diagram
12 V /10 mA
AgSnO
20 x 10 6 switching operations
0.1 Hz
-25 °C…+50 °C
-40 °C…+60 °C
40 °C / 93 % rel. humidity,
no condensation
CE, cUL
300 V
4 kV
III
2
4 kVeff / 1 min
5.5 mm
MRS 24 Vuc 1CO
MRZ 24 Vuc 1CO
MRS 24 Vdc 1CO
MRZ 24 Vdc 1CO
Type Cat. No.
MRS 24 Vdc 1CO 8533640000
MRZ 24 Vdc 1CO 8533660000
24 Vdc ± 20 % (19.2...28.8 V)
6.6 mAdc ±10 %
160 mW ±10%
15.4 V / 4 mA
6.5 V / 1.2 mA
Green LED
6.6 ms
5.8 ms
24 V
yes
yes
yes
1 changeover contact
250 Vac acc. to VDE
240 Vac acc. to UL/CSA
max. 6 A / max. 1500 VA
max. 6 A
see limit diagram
12 V /10 mA
AgSnO
20 x 10 6 switching operations
0.1 Hz
-25 °C…+50 °C
-40 °C…+60 °C
40 °C / 93 % rel. humidity,
no condensation
CE, cUL
300 V
4 kV
III
2
4 kVeff / 1 min
5.5 mm
Type Cat. No.
MRS 24 Vuc 1CO8556050000
MRZ 24 Vuc 1CO 8556120000
24 Vuc ±10% (21.6...26.4 V)
11 mA ± 10 %
6.4 mA ±20 %
154 mW ±10 %
15.8 V / 3.6 mA
7 V / 1.3 mA
Green LED
7.3 ms
9 ms
24 V
yes
yes
yes
1 changeover contact
250 V ~ acc. to VDE
240 V ~ acc. to UL/CSA
max. 6 A / max. 1500 VA
max. 6 A
see limit diagram
12 V /10 mA
AgSnO
20 x 10 6 switching operations
0.1 Hz
-25 °C…+50 °C
-40 °C…+60 °C
40 °C / 93 % rel. humidity,
no condensation
CE, cUL
300 V
4 kV
III
2
4 kVeff / 1 min
5.5 mm
Relay Couplers on Sockets MICROSERIES in Terminal Format
Relay Couplers on Sockets MICROSERIES in Terminal Format
88
Tension clamp version MRZ Screw version MRS
Accessories
General technical data
Clampable conductor:
Solid H07V-U mm2
Fsolid H07V-K mm2
„f“ with ferrules acc. to DIN 46 228/1* mm2
„f“ with ferrules with plastic collar* mm2
Max. clampable range in mm
2
/gauge pin acc. to IEC 60 947-1 Size
Rated torque
Continuous current of cross-connection 2-pole A
Continuous current of cross-connection multipole A
Insulation stripping length mm
Protection class
Housing material
Flammability class UL 94
Rated current
Rated voltage
Cross-connection
Pluggable cross-connection
ZQV yellow
red
blue
black
Markings
12 x 6 mm
Screwdriver
Tension clamp version
0.5…2.5
0.5…2.5
0.5…1.5
0.5…1.5
0.13…2.5 A 2
-
10
10
10
IP 20
Wemid
V0
6 A
250 V
Type Cat. No. Qty.
ZQV 4N / 2 GE 1758250000 60
ZQV 4N / 3 GE 1762630000 60
ZQV 4N / 4 GE 1762620000 60
ZQV 4N / 10 GE 1758260000 20
ZQV 4N / 41 GE 1758270000 10
ZQV 4N / 2 RT 1793950000 60
ZQV 4N / 3 RT 1793980000 60
ZQV 4N / 4 RT 1794010000 60
ZQV 4N / 10 RT 1794040000 20
ZQV 4N / 41 RT 1794070000 10
ZQV 4N / 2 BL 1793960000 60
ZQV 4N / 3 BL 1793990000 60
ZQV 4N / 4 BL 1794020000 60
ZQV 4N / 10 BL 1794050000 20
ZQV 4N / 41 BL 1794080000 10
ZQV 4N / 2 SW 1793970000 60
ZQV 4N / 3 SW 1794000000 60
ZQV 4N / 4 SW 1794030000 60
ZQV 4N / 10 SW 1794060000 20
ZQV 4N / 41 SW 1794090000 10
Type Cat. No. Qty.
WS 10/6 1060960000 200
WS 12/6 1061160000 200
Type Cat. No. Qty.
SD 0.6 x 3.5 x 100 9008330000 10
Screw version
0.5…4
0.5…2.5
0.5…1.5
0.5…1.5
0.13…4 A 3
0.6 Nm
10
10
7
IP 20
Wemid
V0
6 A
250 V
Type Cat. No. Qty.
ZQV 4N / 2 GE 1758250000 60
ZQV 4N / 3 GE 1762630000 60
ZQV 4N / 4 GE 1762620000 60
ZQV 4N / 10 GE 1758260000 20
ZQV 4N / 41 GE 1758270000 10
ZQV 4N / 2 RT 1793950000 60
ZQV 4N / 3 RT 1793980000 60
ZQV 4N / 4 RT 1794010000 60
ZQV 4N / 10 RT 1794040000 20
ZQV 4N / 41 RT 1794070000 10
ZQV 4N / 2 BL 1793960000 60
ZQV 4N / 3 BL 1793990000 60
ZQV 4N / 4 BL 1794020000 60
ZQV 4N / 10 BL 1794050000 20
ZQV 4N / 41 BL 1794080000 10
ZQV 4N / 2 SW 1793970000 60
ZQV 4N / 3 SW 1794000000 60
ZQV 4N / 4 SW 1794030000 60
ZQV 4N / 10 SW 1794060000 20
ZQV 4N / 41 SW 1794090000 10
Type Cat. No. Qty.
WS 10/6 1060960000 200
WS 12/6 1061160000 200
Type Cat. No. Qty.
SD 0.6 x 3.5 x 100 9008330000 10
91 mm 92 mm
93 mm
94 mm
6.1 mm 6.1 mm
Relay Couplers on Sockets MICROSERIES in Terminal Format
Digital signal
processing
89
Type NAIS APE... Cat. No. Qty.
… 30005V 4061580000 20
… 30012V 4061610000 20
… 30024V 4060120000 20
… 30048V 4061620000 20
… 30060V 4061630000 20
… 30124V 4061590000 20
… 30160V 4061600000 20
1 changeover contact
Single contact
6 A
300 Vdc / 400 Vac
1500 VA
AgSnO2
100 mA, 12 V
1 ms
5 ms
V-0
-40 ... +85 °C
6/1200 switching operations per minute
5 / 2.5 ms
1.5 / 5 ms
IP 67
www.matsushita.de
Pluggable relay
Coil voltage 5 V, 1 changeover contact
Coil voltage 12 V, 1 changeover contact
Coil voltage 24 V, 1 changeover contact
Coil voltage 48 V, 1 changeover contact
Coil voltage 60 V, 1 changeover contact
Coil voltage 24 V, 1 changeover contact, 5 µAU
Coil voltage 60 V, 1 changeover contact, 5 µAU
Technical data (of relay manufacturer)
Contact number and type
Contact version
Switching current
Switching voltage / max. Switching voltage
Braking capacity
Contact material
Recommended min. load
Typ. bounce time NO contact
Typ. bounce time normally closed contact
Miscellaneous data
Flammability class UL
Ambient temperature
Max. switching operations with rated load / without load
Response / drop out time
Bounce time NO contact / normally closed contact
Protection class Housing
For further data see also
Contact service life
Material AgSnO2
switch. operations
switch. operations
Accessories
acc. to
90
Relay Couplers on Sockets RS 30
Rated data
Input voltage 5…60 V ± 10%; 115 V/230 V + 5% – 15%
Rated consumption – (W)
Rated consumption ~ (VA)
Drop-out current of the relay (at 20 °C)
Drop-out current of the relay (at 20 °C)
Pick-up current
Max. output voltage
Continuous current
Derating curve
a = mounted horizontally on rail without clearance
b = mounted horizontally on rail with clearance x 20 mm
Continuous
current
Ambient temperature
Switch-on current
Switching capacity with resistive load
Min. switching capacity/switching current
Bounce times
Switching times, typical
–, pick-up lag
–, turn off delay
Max. switching frequency
Contact material
Service life, mechanical
–, 24 V–, 1 A, resistive load
–, 230 V~, 3 A, resistive load
Storage temperature
Ambient temperature
–, mounted on rail without clearance
–, mounted on rail with clearance 20 mm
Insulation coordination acc. to EN 50178
Overvoltage category
Pollution severity
Dimensions
Mounting width
Length (perpendicular to mounting rail)
Height TS 32/TS 35 x 7.5
Schematic circuit diagram 1234
5 VTTL 12 V– 24 V– 24 V048 V– 48 V060 V– 115 V~ 115 V– 230 V~2)240 V~
0.45 W1)0.45 W 0.45 W 0.45 W 0.45 W 0.45 W 0.45 W 0.82 W
–––0.7 VA 0.6 VA 0.8 VA 0.8 VA 1.2 VA
–3 mA 3 mA 2.5 mA– 2 mA 2.5 mA– 1 mA– 2 mA– 0.5 mA–
–––3.5 mA~ 4.5 mA~ 1 mA~ 1 mA~ 1 mA~
––12 mA 10 mA 6 mA 4.3 mA
250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V
5 A 6 A6 A6 A6 A5 A 5 A 5 A 5 A3 A3 A
8 A
2000 VA/100 W
250 mW/10 mA
3 ms
8 ms 8 ms 8 ms 8 ms 12 ms 13 ms 12 ms 9 ms 12 ms 10 ms 10 ms
7 ms 7 ms 7 ms 16 ms 11 ms 12 ms 11 ms 8 ms 11 ms 9 ms 9 ms
70 Hz 70 Hz 70 Hz 30 Hz 70 Hz 20 Hz 70 Hz 30 Hz 70 Hz 30 Hz 30 Hz
AgNi, gold-flashed
>107switching operations
> 5 x 105 switching operations
>7 x 105switching operations
–40 °C…+60 °C
–25 °C…+40 °C
–25 °C…+50 °C
III
2
11.2 mm NO/NC, 25 mm changeover contacts
70 mm (74 mm BL/SL version)
56 mm/51.5 mm
Continuous current
Continuous operation
Clearance > 20 mm
On/off switch. mode
< 1 min (50/50 %)
48 V~/230 V~/240 V~
1) Rated consumption with 24 VDC auxilary voltage.
2) 230 V– on request
1 NC, 1 NO
or 1 changeover contact
Digital signal
processing
91
RS 30
Disconnect plug with
screw connection
1 changeover contact
RS 30 TTL
Disconnect plug with
screw connection
1 NO and 1 NC
5678
Input
voltage
5 V–, TTL
12 V–
24 V–
24 Vb
48 V–
48 Vb
60 V–
115 V–
115 V~
230 V~
240 V~
Ordering data
Connection method
Schematic circuit diagram
Contact
Function
indicator
None
None
Red LED
None
Green LED
Red LED
None
Green LED
Red LED
None
Green LED
Red LED
None
Green LED
Red LED
None
Green LED
Red LED
None
Green LED
Red LED
None
Green LED
Red LED
None
Green LED
Red LED
None
Green LED
Red LED
Screw connection (LP) Disconnect plug with screw connection (BL/SL)
12345 6788
NO NO NC NC changeo. c. changeo. c. changeo. c. NO NC
1167760000 1167660000
1129660000
1129421001 1129521001
1101661001 1100961001 1100260000
1101611001 1100911001 1181511001 1100210000
1101621001 1100921001 1181521001 1100220000
1101761001 1101061001 1100360000
1101711001 1101011001
1101721001 1101021001
1101861001 1101161001 1100460000
1101811001 1101111001 1100410000
1101821001 1101121001 1100420000
1101961001 1101261001 1100560000
1101911001 1101211001
1101921001 1101221001
1102061001 1100660000
1102011001 1100610000
1102021001 1100620000
1155161001 1155261001
1155111001 1155211001
1155121001 1155221001
1102161001 1101461001 1100760000
1102111001 1101411001
1102121001 1101421001
1102261001 1101561001 1100860000
1102211001 1101511001
1102221001 1101521001
1128561001 1128661001
1128511001 1128611001
1128521001 1128621001
RS 30
Screw connection
1 NO
1 NC
RS 30
Screw connection
1 changeover contact
Relay Couplers on Sockets RS 30
92
Relay Couplers on Sockets RS 30
RS 31
with power contacts
Ordering data
Rated data
Input voltage
Rated consumption – (W)
Rated consumption – (VA)
Drop-out current of the relay (at 20 °C)
Drop-out current of the relay (at 20 °C)
Max. output voltage
Continuous current
Derating curve
mounted horizontally on rail without clearance
Continuous
current
Ambient temperature
Switch-on current
Max. switching capacity with resistor load
Min. switching capacity/switching current
Bounce times
Switching times, typical
–, pick-up lag
–, turn off delay
Max. switching frequency
Contact material
Service life, mechanical
– 230 V, 50 Hz, 3.5 kV A
Status indicator Red LED
Yellow LED
Green LED
Storage temperature
Ambient temperature
Insulation coordination acc. to EN 50178
Overvoltage category
Pollution severity
Dimensions
Mounting width
Length (perdendicular to mounting rail)
Height with TS 32/TS 35 x 7.5
Schematic circuit diagram
Type Cat. No.
RS 31, 24 V– 1128361001
RS 31, 24 V– 1128331001
RS 31, 24 V– 1128311001
24 V–, ±10 %
1 W
11.5 mA–
250 V
16 A
60 A/200 ms
3.5 kVA/480 W
1 W/100 mA
< 3 ms
< 9 ms
< 10 ms
AgCdO
3 x 107 switching operations
2.5 x 105
switching operations
1128361001
1128331001
1128311001
–40 °C…+60 °C
–25 °C…+40 °C
III
2
25 mm
70 mm
58 mm/53.5 mm
Type Cat. No.
RS 31, 48 V– 1150761001
48 V–, ±10 %
1 W
13.5 mA–
250 V
16 A
60 A/200 ms
3.5 kVA/480 W
1 W/100 mA
< 6 ms
< 12 ms
< 8 ms
AgCdO
3 x 107switching operations
2.5 x 105
switching operations
1150761001
–40 °C…+60 °C
–25 °C…+40 °C
III
2
25 mm
70 mm
58 mm/53.5 mm
Type Cat. No.
RS 31, 115 V– 1150361001
115 V–, +5 % –15 %
1 W
5.5 mA–
250 V
16 A
60 A/200 ms
3.5 kVA/480 W
1 W/100 mA
< 6 ms
< 10 ms
< 12 ms
AgCdO
3 x 107 switching operations
2.5 x 105
switching operations
1150361001
–40 °C…+60 °C
–25 °C…+40 °C
III
2
25 mm
70 mm
58 mm/53.5 mm
Type Cat. No.
RS 31, 115 V~ 1150461001
115 V~, +5 % –15 %
1 VA
1.5 mA~
250 V
16 A
60 A/200 ms
3.5 kVA/480 W
1 W/100 mA
< 6 ms
< 4 ms
< 11 ms
AgCdO
3 x 107switching operations
2.5 x 105
switching operations
1150461001
–40 °C…+60 °C
–25 °C…+40 °C
III
2
25 mm
70 mm
58 mm/53.5 mm
1 changeover contact
Usable for high switching-power
Suitable for switching inductive loads
Digital signal
processing
93
RS 31
with power contacts
Type Cat. No.
RS 31, 230 V~ 1128461001
RS 31, 230 V~ 1128431001
RS 31, 230 V~ 1128411001
230 V~, +5 % –15 %
1 VA
2.2 mA~
250 V
16 A
60 A/200 ms
3.5 kVA/480 W
1 W/100 mA
< 6 ms
< 10 ms
< 8 ms
AgCdO
3 x 107switching operations
2.5 x 105switching operations
1128461001
1128431001
1128411001
–40 °C…+60 °C
–25 °C…+40 °C
III
2
25 mm
70 mm
58 mm/53.5 mm
Relay Coupler on Locking Socket Profile RS 31
94
Relay Couplers on Sockets RS 32
RS 32 RS 32
Ordering data
Rated data
Input voltage
Rated consumption – (W)
Rated consumption ~ (VA)
Drop-out current of the relay** (at 20 °C)
Drop-out current of the relay** (at 20 °C)
Max. output voltage
Continuous current
Derating curve
mounted horizontally on rail without clearance
Continuous
current
Ambient temperature
Switch-on current
Max. switching capacity with resistor load
Min. switching capacity/switching current
Bounce times
Switching times, typical
–, pick-up lag
–, turn off delay
Max. switching frequency
Contact material
Service life, mechanical
–, 24 V–, 1 A, resistive load
–, 230 V~, 3 A, resistive load
Status indicator
Storage temperature
Ambient temperature
Approvals
Insulation coordination acc. to EN 50178
Overvoltage category
Pollution severity
Dimensions
Mounting width
Length (perpendicular to mounting rail)
Height with TS 32/TS 35 x 7.5
Schematic circuit diagram
Type Cat. No.
RS 32 9406021001
12 V–, ±10 %
0.6 W
9.5 mA
250 V
2 x 4 A
2 x 6 A
1400 VA
4 ms
13 ms
10 ms
AgNi0.15, gold-flashed
> 30x106
switching operations
Red LED
–40 °C…+60 °C
–25 °C…+40 °C
III
2
25 mm
70 mm
68 mm/63.5 mm
Type Cat. No.
RS 32 9406121001
24 V–, ±10 %
0.6 W
5 mA
250 V
2 x 4 A
2 x 6 A
1400 VA
4 ms
13 ms
10 ms
AgNi0.15, gold-flashed
> 30x106
switching operations
Red LED
–40 °C…+60 °C
–25 °C…+40 °C
CSA
III
2
25 mm
70 mm
68 mm/63.5 mm
Type Cat. No.
RS 32 9406221001
24 V0, ±10 %
0.6 W
0.9 VA
24 V–: 4.5 mA
24 V~: 2.5 mA
250 V
2 x 4 A
2 x 6 A
1400 VA
4 ms
13 ms
10 ms
AgNi0.15, gold-flashed
> 30x106
switching operations
Red LED
–40 °C…+60 °C
–25 °C…+40 °C
III
2
25 mm
70 mm
68 mm/63.5 mm
Type Cat. No.
RS 32 9406321001
48 V–, ±10 %
0.6 W
2 mA
250 V
2 x 4 A
2 x 6 A
1400 VA
4 ms
13 ms
10 ms
AgNi0.15, gold-flashed
> 30x106
switching operations
Red LED
–40 °C…+60 °C
–25 °C…+40 °C
CSA
III
2
25 mm
70 mm
68 mm/63.5 mm
9406021001 9406121001
9406321001
9406521001
with 2 changeover contacts
Digital signal
processing
95
RS 32
Type Cat. No.
RS 32 9406421001
48 V0, ±10 %
0.6 W
0.9 VA
48 V–: 2 mA
48 V~: 4.5 mA
250 V
2 x 4 A
2 x 6 A
1400 VA
4 ms
13 ms
10 ms
AgNi0.15, gold-flashed
> 30x106
switching operations
Red LED
–40 °C…+60 °C
–25 °C…+40 °C
III
2
25 mm
70 mm
68 mm/63.5 mm
Type Cat. No.
RS 32 9406521001
60 V–, ±10 %
0.6 W
1.5 mA
250 V
2 x 4 A
2 x 6 A
1400 VA
4 ms
10 ms
10 ms
AgNi0.15, gold-flashed
> 30x106
switching operations
Red LED
–40 °C…+60 °C
–25 °C…+40 °C
III
2
25 mm
70 mm
68 mm/63.5 mm
Type Cat. No.
RS 32 9406621001
115 V0, +5 % –15 %
0.5 W
0.6 VA
115 V–: 1 mA
115 V~: 1.5 mA
250 V
2 x 4 A
2 x 6 A
1400 VA
4 ms
13 ms
10 ms
AgNi0.15, gold-flashed
> 30x106
switching operations
Red LED
–40 °C…+60 °C
–25 °C…+40 °C
III
2
25 mm
70 mm
68 mm/63.5 mm
Type Cat. No.
RS 32 9406721001
230 V0, +5 % –15 %
1 W
1 VA
230 V–: 1.2 mA
230 V~: 2 mA
250 V
2 x 4 A
2 x 6 A
1400 VA
4 ms
13 ms
10 ms
AgNi0.15, gold-flashed
> 30x106
switching operations
Red LED
–40 °C…+60 °C
–25 °C…+40 °C
III
2
25 mm
70 mm
68 mm/63.5 mm
Type Cat. No.
RS 32 1122661001
24 V/48 V0, ±10 %
0.5 W/0.6 W
0.7 VA/0.9 VA
–: 5 mA/2 mA
~: 3 mA/4.5 mA
250 V
2 x 4 A
2 x 6 A
1400 VA
4 ms
13 ms
10 ms
AgNi0.15, gold-flashed
> 30x106
switching operations
Green LED
–40 °C…+60 °C
–25 °C…+40 °C
III
2
25 mm
70 mm
68 mm/63.5 mm
Type Cat. No.
RS 32 1122761001
115 V/230 V0, +5 % –15 %
0.5 W/1 W
0.6 VA/1 VA
–: 1 mA/1.2 mA
~: 1.5 mA/2 mA
250 V
2 x 4 A
2 x 6 A
1400 VA
4 ms
13 ms
10 ms
AgNi0.15, gold-flashed
> 30x106
switching operations
Green LED
–40 °C…+60 °C
–25 °C…+40 °C
III
2
25 mm
70 mm
68 mm/63.5 mm
9406221001
9406421001
9406621001
9406721001
1122661001
1122761001
Relay Couplers on Sockets RS 32
96
Multiple Socket Interface RSM
RSM 4 R 4 relays, soldered
RSM 4 RS 4 relays, plug-in
Rated data
Input voltage
Rated consumption –(W) soldered relay
plug-in relay
Rated consumption ~(VA) soldered relay
plug-in relay
Pick-up current – (mA) soldered relay
(mA) plug-in relay
Pick-up current ~ (mA) soldered relay
(mA) plug-in relay
Drop-out current of the relay (at 20 °C)
Max. output voltage
Continuous current
Derating-curve
a = mounted horizontally on rail without clearance
b = mounted horizontally on rail with clearance 20 mm
Continuous
current
Ambient temperature
Switching times, typical
–, pick-up lag (–/~)
–, turn off delay (–/~)
Bounce times
Switch-on current
Switching capacity with resistive load
Min. switching capacity/switching current
Contact material
Service life, mechanical
–, 24 V–, 1 A, resistive load
–, 230 V~, 3 A, resistive load
Storage temperature
Ambient temperature
Insulation coordination acc. to EN 50178
Overvoltage category
Pollution severity
Dimensions
Conductor cross-section (screw connection)
Spare relay (pluggable)
for 24 V-RSM types
for 48 V-RSM types
for 115 V, 230 V-RSM types
Also available as opto-coupler (max. 48 V),
See page 120/121
Schematic circuit diagram
Fixing feet can also be mounted turned through 180°
DC voltage, positive switching
24 V– 24 V048 V– 48 V0115 V~ 115 V0230 V~ 230 V0
0.45 W 0.45 W 0.45 W 0.45 W
0.55 W 0.55 W
0.5 VA 0.6 VA 0.6 VA 0.6 VA 0.9 VA 0.9 VA
––––0.6 VA 0.6 VA 1.2 VA 1.2 VA
12 mA 10 mA 5 mA 3 mA
23 mA 12 mA 14 mA
–––––6 mA 3.5 mA
16.5 mA 5 mA 4 mA
2 mA 1.5 mA 1 mA 1 mA
250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V
6 A 6 A 6 A 6 A 6 A 6 A 3 A 3 A
8 ms
10 ms/10 ms
12 ms
10 ms/12 ms
10 ms 8 ms/10 ms 10 ms 8 ms/10 ms
7 ms
15 ms/20 ms
11 ms
15 ms/20 ms
10 ms 5 ms/8 ms 10 ms 7 ms/8 ms
3 ms
3 ms
3 ms
3 ms
3 ms
3 ms
3 ms
3 ms
8 A 8 A 8 A 8 A 8 A 8 A 8 A 8 A
2000 VA 2000 VA 2000 VA 2000 VA 2000 VA 2000 VA 2000 VA 2000 VA
250 mW/10 mA
AgNi 90/10, AgNi0,15, gold-flashed
> 30x106switching operations
>5 x 105switching operations
>7 x 105switching operations
–40 °C…+60 °C
–25 °C…+50 °C
III
2
0.5…2.5 mm2
Input voltage Contact material Cat. No. Notes
24 V– AgNi 90/10 8630780000 RT 314024 with yoke
24 V– AgNi 90/10 4058480000 RT 314024 without yoke
48 V– AgNi 90/10 8630790000 RT 314048 with yoke
48 V– AgNi 90/10 4058740000 RT 314048 without yoke
115 V– AgNi 90/10 8630770000 RT 314110 with yoke
115 V– AgNi 90/10 4058500000 RT 314110 without yoke
115 V– Au 5 4156970000 ZLT input relay KHU/BV 1680
RSM 8 R 8 relays, soldered
RSM 8 RS 8 relays, plug-in
(Relay Coupler)
with one changeover contact each
Digital signal
processing
97
Ordering data
Connection technology
Input/output
Ribbon cable/
Screw connection
Male connector block with interlock
according to DIN 41651/Parts 1 and 2
Screw connection
• Input: - Relay pluggable
Screw connection and
male conn. block acc. to
IEC 603-1/ DIN 41651
-Relay soldered
male conn. block acc. to
IEC 603-1/ DIN 41651
• Output: Screw connection
Spare relays
on request
Red LEDs, further colours on request
DC voltage, negative switching AC-DC/DC voltage
RSM 16 RS
16 relays, plug-in
Input RSM 4 R/RS RSM 8 R/RS
RSM 16 R/RS
Positve Negative Relay Relay Relay Mounted
voltage 4 relays 8 relays 16 relays switching1)switching2)pluggable pluggable soldered width
24 VDC 1113161001 145 mm
 1100061001 145 mm
 1113261001 285 mm
 1100161001 285 mm
24 VDC 11133610013)80175810014)1112361001 75 mm
11134610013)1112761001 75 mm
11135610013) 80036710014) • 1107761001 145 mm
11136610013) 1112661001 145 mm
 11137610013) 80182210014) • 1107861001 285 mm
11138610013) 1113061001 285 mm
24 V01173461001 75 mm
1173561001 145 mm
1173661001 285 mm
48 VDC 1113961001 1112461001 75 mm
1114061001 75 mm
1114161001 145 mm
1114261001 145 mm
 1114361001 285 mm
1114461001 285 mm
48 V01173761001 75 mm
115 V01114561001 75 mm
1114661001 145 mm
1114761001 285 mm
230 V~ 1114861001 75 mm
1114961001 145 mm
1115061001 285 mm
230 V01123461001 75 mm
1108061001 145 mm
1108261001 285 mm
1) Common negative potential, positive is switched
2) Common negative potential, negative is switched
3) Approval by the Germanischer Lloyd
4) Empty modules without relays
Multiple Socket Interface RSM
98
The contacts available at the output are:
2, 3 or 4 changeover contacts.
The marking of the contacts in the follow-
ing diagram corresponds to European
standard EN 50005.
The standard range of relay socket mod-
ules is divided as follows:
Group 1:
RS 3 (2 changeover contacts)
RS 4, RS 14 (4 changeover contacts)
For relays of the type “international”
Group 2:
RS 6 (2 changeover contacts) Size 1
RS 7, 17 (3 changeover cont.) Size 2
RS 8, 18 (4 changeover cont.) Size 2
RS 9 (2 changeover cont.) Size 2
For relays of the type "European".
Relays with 4 changeover contacts (size 2)
can be secured to RS 7, RS 17 and RS 9;
however, only 3 or 2 changeover contacts
are connected to the terminals, which
results in space savings.
Group 3: RS 21 (2 changeover contacts)
RS 23 (3 changeover contacts)
RS 24 (2 x 3 changeover cont.)
For relays with one socket with 8 or 11
pins.
The table on page 87 offers an overview of
the most important manufacturers of
relays in groups 2, 3 and 4. The list is pro-
vided for information purposes only, and
does not claim to be complete
Weidmüller relay sockets for mounting rails
enable plug-in relays most commonly
used in industry to be mounted; they
make possible installations in which the
control section and power section are per-
fectly separated. The coil terminals and
the connection terminals are located on
opposite sides of the locking socket mod-
ules.
The conductors are connected via screw
terminals; the securing in the terminal is
achieved by a clamping yoke system. This
method has been used by Weidmüller for
many years, and is the only method that
guarantees a reliable connection in indus-
trial applications.
Thanks to their combination foot, these
modules can be mounted onto TS 32, TS
35x7.5, TS 35x15 mounting rails in accor-
dance with European standards EN 50035
and EN 50022.
The connections are marked according to
European Standard EN 50005. The mod-
ules are designed for DC relays (with a
damping diode parallel to the coil, as well
as a protection diode for reverse polarity
protection) and AC relays.
They can be provided with an LED on
request.
DC voltage
Ac voltage
The input terminals are doubled, in order
to pick off the poles. Note the following for
DC current operation:
A1 = +
A2 = –
Relay Socket Module for Industry Relays
Digital signal
processing
99
List of Plug-in Relays for Weidmüller Relay Socket Modules
Manufacturer
EBERLE
ELESTA
FEME
GRUNER
HALLER
ITT (MTI)
FUJITSU
KUHNKE
KUKE
NATIONAL
OMRON
POTTER & BRUMFIELD
RAPA
Tyco/SCHRACK
SDS
TEC
ZETTLER
Group 1
International relays
• RS 3 2 changeover contacts
• RS 4, RS 14 4 changeover contacts
Relay type
•–
•–
•–
•–
•–
•–
•–
•–
•–
•–
• MAT 2
• MAT 4
• FRL 263-02
• FRL 263-04
•–
• Type 111 A4
•–
•–
• HC 2
• HC 4
• MY 2
• MY 4
•–
• Series KH
•–
•–
• ZT 4
• PT 4
• HC 2
• HC 4
•–
• Type 1301
•–
• TEC 1401
Group 2
European relays
• RS 6 2 changeover contacts (Size 1)
• RS 7, RS 17 3 changeover cont. (Size 2)
• RS 8, RS 18 4 changeover cont. (Size 2)
• RS 9 2 changeover cont. (Size 2)
Relay type
•–
• Type 40701
• Type 40701
•–
•–
•–
•–
•–
•–
•–
•–
• Series 9065 G
• Series 9059 G/9066 G
• Series 9059 G/9066 G
• Series 9059 G/9066 G
• Series H-561 Size 1
• Series H-561 Size 2
• Series H-561 Size 2
• Series H-561 Size 2
• Type 24
• Type 25
• Type 25
• Type 25
•–
•–
•–
•–
•–
•–
•–
•–
• Miniature relays Type 01
• Miniature relays Type 02
• Miniature relays Type 02
• Miniature relays Type 02
•–
•–
•–
•–
• MHS-2
• MHS-4
• MHS-4
• MHS-4
•–
• Series R 10
• Series R 10
• Series R 10
• Series 012 Size 1
• Series 012 Size 2
• Series 012 Size 2
• Series 012 Size 2
• Relays N, S, W Size 1
• Relays N, S, W Size 2
• Relays N, S, W Size 2
• Relays N, S, W Size 2
• K 2
• K 4
• K 4
• K 4
• Type 1350
• Type 1360
• Type 1360
• Type 1360
• AZ E 20, AZ 420, AZ 420 W
• AZ E 21, AZ 421, AZ 421 W
• AZ E 21, AZ 421, AZ 421 W
• AZ E 21, AZ 421, AZ 421 W
Group 3
Relays with socket oktal
• RS 21 2 changeover contacts
• RS 23 3 changeover contacts
• RS 24 2x3 changeover contacts
Relay type
•–
• Type 41454
• Type 41454
• SKR 085
• SKR 115
• RCP 8
• RCP 11
• RCP 11
• Series 668 B 2 changeover contacts
• Series 668 A 3 changeover contacts
• Series 668 A 3 changeover contacts
• HB-1/1
• HB-1/2
• HB-1/2
•–
•–
•–
• FRL 256-02
• FRL 256-04
• FRL 256-04
• Universal relays-M/-H/-U
• Universal relays-M/-H/-U
• Universal relays-M/-H/-U
•–
•–
•–
•–
•–
•–
• MK 2
• MK 3
• MK 3
• Series KAP
• Series KAP
• Series KAP
• Series C-Type CKR
• Series C-Type CKR
• Series C-Type CKR
• Series RN/RC
• Series RN/RC
• Series RN/RC
• Type 1210
• Type 1210
• Type 1210
• AZ 1010 – AZ 509 2 C
• AZ 1010 – AZ 509 3 C
• AZ 1010 – AZ 509 3 C
100
Relay Sockets for Industry Relays
PT 4 industry relays
4-pole, with test button
Rated data
Contact data
Contact number and type
Contact version
Contact material
Max. braking capacity AC
Rated voltage
Continuous current
Switch-on current
Min. contact rating
Mechanical service life
Response / drop out time
Bounce time
Test voltage
Isolation acc. to IEC664
Rated voltage
Pollution severity
Overvoltage category
Insulation group / reference voltage
Approvals
Miscellaneous data
Protection class
Flammability class UL 94
Ambient temperature DC coil
AC coil
Weight
Correspond. relay socket
Ordering data
6 V–
12 V–
24 V–
48 V–
60 V–
115 V–
6 V~
12 V~
24 V~
48 V~
60 V~
115 V~
230 V~
Retainer clip for SIEMENS-Relays
4 changeover contacts
Single contacts
AgNi 90/10, AgNi 90/10 htv
1500 VA
250 V~
6 A / contact
12 A / contact
24V, 10 mA / 20 m, 1 mA htv
DC coil > 30x106
AC coil > 20x106
15/10 ms
5 ms
2.5 kVeff coil / contact
B, 60 V~/75 V
250 V
2
III
B/250
VDE, UL, CSA
IP50
V-0
-40 … + 70 °C
-40 … + 70 °C
30g
• Relay sockets Type RS 3, RS 4 and RS 14
• Alternatives to ZT 4 see table on page 99
Type (ZT 4) Best.-Nr
PT 570006 8074650000
PT 570012 8054360000
PT 570024 1180700000
PT 570048 8074670000
PT 570060 8074680000
PT 570110 8074700000
PT 570506 8074710000
PT 570512 8074730000
PT 570524 1181800000
PT 570548 1180900000
PT 570560 8074760000
PT 570615 1180800000
PT 570730 1181100000
PT 28800 8572170000
0125661001
Schrack
Type PT 5
4-pole
4 changeover contacts
RS 14
0125561001
1157561001
0125661001
1127661001
8025451001
45 mm
7 mm
0.5…4 mm2
0.5…2.5 mm2
AWG 26…14
250 V0
125 V~
5 A
Type Cat. No. Qty.
TS 32 0122800000
TS 35x7.5 0383400000
TS 35x15 0498000000
EWK 2 0199360000 50
EW 35 0383560000 50
ESo 7 0515200000
SSt 7 0515300000 100
ZG 28800 0116000000 25
Digital signal
processing
101
Relay Sockets for Industry Relays
Relay sockets for DC and AC
voltage relays
with fixing foot for TS 32/TS 35x7.5 and TS 35x15
Relay type*
Contacts on module
Ordering data Sockeltyp
Relay socket for AC relays
(without diode)
With red LED (230 V~)
Relay socket for DC relays
with suppressor diode and reserve voltage protection
(diode 1 N 4007)
With red LED (24 V–)
With green LED (24 V–)
Dimensions
Relay socket width
Insulation stripping length
Connection data
Screw connection, solid
Screw connection, flexible
Conductor cross-section
Rated data
Coil voltage (types without LED)
Contact voltage
Contact current
Accessories
Mounting rail (2 m lenghts)
End bracket (thickness mm)
Insert tag (blanc)**
Protective strip, transparent**
Retainer clip for Schrack relays
Schrack Schrack
Type PT 5 Type PT 5
4-pole 4-pole
2 changeover contacts 4 changeover contacts
RS 3 RS 4
0115161001 0116261001
0115061001 0116161001
0116121001
0115011001
35 mm 65 mm
7 mm 7 mm
0.5…4 mm20.5…4 mm2
0.5…2.5 mm20.5…2.5 mm2
AWG 26…14 AWG 26…14
250 V0250 V0
250 V~ 125 V~
5 A 5 A
Type Cat. No. Qty.
TS 32 0122800000
TS 35x7.5 0383400000
TS 35x15 0498000000
EWK 2 0199360000 50
EW 35 0383560000 50
ESo 7 0515200000
SSt 7 0515300000 100
ZG 28800 0116000000 25
* Relay not included in delivery
RS 3 RS 4 RS 14
102
Relay Sockets for Industry Relays
RS 6 RS 6 RS 8 RS 9 RS 17 RS 18
Assigning commercially available relays to the
Weidmüller relay sockets RS 6...RS 24:
Relay socket RS 6
Siemens cradle relay, size I
Zettler cradle-operated relay AZ 420
RAPA range 012, size 1
Relay socket type RS 7, RS 8, RS 9, RS 17
and RS 18
Siemens cradle relay, size II
Zettler cradle-operated relay AZ 421
RAPA range 012, size II
Relay socket type RS 21, RS 23 and RS 24
Siemens/Schrack Universal
Industry relay RS/RN/RC
Siemens industry relay 10
Kuhnke universal relay
Zettler industrial relay AZ 1010
RAPA range C
(No claim is made that this is a complete list of manu-
facturers of relays or types of relays.)
Relay type*
Ordering data Socket type
Relay socket for AC relays
(without diode)
Relay socket for DC relays
with suppressor diode and reserve voltage protection
(diode 1 N 4007)
With red LED (24 V–)
With green LED (24 V–)
Dimensions
Relay socket width
Insulation stripping length
Connection data
Screw connection, solid
Screw connection, flexible
Conductor cross-section
Rated data
Coil voltage (types without LED)
Contact voltage
Contact current
Accessories
Mounting rail (2 m lenghts)
End bracket (thickness mm)
Insert tag (blanc)**
Protective strip, transparent**
Retainer clip for Schrack relays
* Relay not included in delivery ** Not suitable for RS 12
Relay socket for DC and AC voltage relays
with locking foot
for TS 32
TS 35x7.5
and TS 35x15
0126061001
Kamm-R.®Kamm-R.®
Gr. II Gr. II
3 changeov. c. 4 changeov. c.
(e. g. B 110) (e. g. B 110)
RS 17 RS 18
0125861001 0126061001
0126011001
35 mm 45 mm
7 mm 7 mm
0.5…4 mm20.5…4 mm2
0.5…2.5 mm20.5…2.5 mm2
AWG 26…14 AWG 26…14
50 V0250 V0
125 V~ 125 V~
5 A 5 A
Type Cat. No. Qty.
TS 32 0122800000
TS 35x7.5 0383400000
TS 35x15 0498000000
EWK 2 0199360000 50
EW 35 0383560000 50
ESo 7 0515200000
SSt 7 0515300000 100
0115461001
Kamm-R.®Kamm-R.®Kamm-R.®Kamm-R.®
Gr. I Gr. II Gr. II Gr. II
2 changeov. c. 3 changeov. c. 4 changeov. c. 2 changeov. c.
(e. g. B 104) (e. g. B 110) (e. g. B 110) (e. g. B 104)
RS 6 RS 7 RS 8 RS 9
0115361001
0115261001 0115461001 0116361001 0188961001
35 mm 50 mm 65 mm 35 mm
7 mm 7 mm 7 mm 7 mm
0.5…4 mm20.5…4 mm20.5…4 mm20.5…4 mm2
0.5…2.5 mm20.5…2.5 mm20.5…2.5 mm20.5…2.5 mm2
AWG 26…14 AWG 26…14 AWG 26…14 AWG 26…14
250 V0250 V0250 V0250 V0
250 V~ 250 V~ 125 V~ 250 V~
5 A 5 A5 A5 A
Type Cat. No. Qty.
TS 32 0122800000
TS 35x7.5 0383400000
TS 35x15 0498000000
EWK 2 0199360000 50
EW 35 0383560000 50
ESo 7 0515200000
SSt 7 0515300000 100
0167161001
Plug-in relay for Plug-in relay for
Octal socket submagnal socket
8-pole 11-pole
2 changeov. c. 3 changeov. c. 2 x 3 changeov. c.
RS 21 RS 23 RS 24
on request 8010061001 on request
0167161001 0188661001 on request
35 mm 40 mm 75.5 mm
7 mm 7 mm 7 mm
0.5…4 mm20.5…4 mm20.5…4 mm2
0.5…2.5 mm20.5…2.5 mm20.5…2.5 mm2
AWG 26…14 AWG 26…14 AWG 26…14
250 V0250 V0250 V0
250 V~ 250 V~ 250 V~
6 A 6 A6 A
Type Cat. No. Qty.
TS 32 0122800000
TS 35x7.5 0383400000
TS 35x15 0498000000
EWK 2 0199360000 50
EW 35 0383560000 50
ESo 7 0515200000
SSt 7 0515300000 100
Digital signal
processing
103
RS 21 RS 23 RS 24
Relay Coupler, Relay Sockets Module for Industry Relays
104
Opto-coupler
105
Digital signal
processing
Opto-coupler
Basic construction of the opto-coupler
interface:
The heart of the system is the opto-
electronic component (opto-coupler) that
effects the coupling.
An important parameter of this type of
modules is the CTR = current transfer
rate.
The CTR is given in % and is the ratio
between the input current IF and the
maximum available output current IC.
Example: IF = 10 mA; CTR = 100%
=> IC = 10 mA.
The CTR is affected by a number of
parameters such as:
- Ambient temperature
- efficiency of the luminescence diode
- geometric dimensions within the module
It also drops with time. The result is that
the switching levels change due to ageing.
CTR as a function of operating life
To eliminate these effects where possible,
Weidmüller opto-coupler use almost
exclusively semiconductors which have a
long life in terms of CTR.
Moreover, the insulation of a module is
highly important, since the actual coupling
of the input and output circuits takes
place optically. Thus the optical
component has to guarantee separation of
both circuits even in case of a defect.
Weidmüller opto-coupler comply with
DIN VDE 0884 to provide a maximum level
of safety.
Appropriate switching circuits need to be
included to ensure that the entire com-
ponent provides reliable separation in
accordance with DIN VDE 0106,
Part 101.
Circuit diagram of an opto-coupler
Opto-coupler for protective separation
or galvanic isolation
The most important precondition for
achieving protective separation with opto-
electronic coupling modules is the partial
discharge test in accordance with DIN
VDE 0884. Double or reinforced insulation
for protective separation must be dis-
charge proof. High voltage tests, as are
usual with relays, cannot be carried out
with semi-conductors, because they could
lead to the destruction of the semi-con-
ductor. Safe separation for the given rated
voltage is applicable to coupling modules
that are integrated into opto-couplers if:
-the opto-couplers are tested according
to DIN VDE 0884
-clearance and creepage distances on
the PCB and connection elements cor-
respond to EN 50 178, DIN VDE 0106
and 0109.
With increasing automation, potential
separation between the control and field
sides of circuits is becoming increasingly
important. The control unit being the core
of the automation must be electrically safe
and free from feedback when coupled with
the various sensors and actuators. Opto-
coupler are being used in a growing num-
ber of applications. They offer the neces-
sary safety and have further advantages
such as:
- low power uptake on control side
- high switching frequency
- no contact bounce
- wear-free switching
- insensitive to vibration
- use independent of location
- no mechanical parts
- long life
- high insulation voltage
Because of these features, opto-coupler
are an alternative to conventional, me-
chanical relay interfaces.
For industrial usage, Weidmüller offers
modules with various input voltages and
housings.
Input from
control
Output to
periphery
Receiver
t (Life time)
CTR
in %
Sender
106
Opto-coupler
Control side of the opto-coupler
interface
3 basic circuits are to be differentiated on
the input side of the opto-coupler#s inter-
face:
- as a pure DC input with polarity protec-
tion diode wich prevents the opto-cou-
pler from being destroyed if the input
polarity is reversed.
- as an AC/DC input:
Wrong polarity of the DC input signal is
not possible with this switching.
The disadvantage of an AC/DC input cir-
cuit (driven by DC signal) is the low
switching rate since the charging capacitor
(CL, necessary for AC-input signal) lowers
the max. switching rate.
- pure AC-Input:
Here, too, the charging capacity lowers
the max. switching rate considerably.
Weidmüller opto-coupler with AC/DC
or AC input signals are designed for
40…60 Hz power supply.
With AC-signal input the max. switching
rate is below half the power supply
frequency.
A high switching rate is not possible, oth-
erwise continuous switching in tune with
the power frequency would occur.
Output side of the opto-coupler
Weidmüller opto-coupler are designed and
sized for a wide variety of applications.
Demands regarding the load side of opto-
couple modules could be:
- power amplification
- signal conditioning
AC/DC, DC/AC
- short-circuit protection
- interference proof, etc.
To fulfil these requirements, the opto-cou-
pler must contain additional electronic
components which determine the func-
tionality of the opto-coupler.
Thus there are 2 basic output variations
for opto-coupler
Output as
- 2 pole and
- 3 pole circuits
2-pole DC output
The 2-pole DC output is comparable to a
conventional switch. With this type it is
immaterial where the load is in the output
circuit. It is, however, important to provide
the necessary output supply voltage with
the right polarity.
* Sample circuit
* Wiring example
107
Digital signal
processing
Opto-coupler
3-pole DC output
This type of output stage requires for safe
function a potential-linked output voltage
supply with an output that is either positive
switching (common reference potential is
GND or 0 V) or negative switching
(common reference potential is the positive
voltage pole).
Standards
Weidmüller opto-coupler comply with the
following standards:
EN 50 178
Furnishing of power engineering systems
with electronic equipment
DIN VDE 0106 Part 101
Protection against flow of dangerous
currents into the human body; basic
requirements for reliable separation within
electrical equipment.
DIN VDE 0884
Optoelectronic coupling devices for reliable
separation
DIN VDE 0109
Insulation coordination within low-voltage
system including clearance and creepage
distances for equipment
Protective circuit
All opto-coupler have a protective circuit in
the output (generally a free-wheeling
diode).
To prevent decoupling of interference
signals to other leads the load side
should be protected.
Protective circuit for DC output
Protective circuit for AC output
Application example
Position monitoring
with namur intiator
Monitoring an actuator
Opto-couplers are normally given with an
output voltage supply from 5…48 VDC.
These values should not be cut or exceed-
ed on any occasion.
The load current should not be higher than
the stated max. output current.
Continuously exceeding this value will
destroy the output stage.
The derating curve shows the dependency
of the output current as a function of the
Ambient temperature (see under the
respective product on the following
pages).
2-pole AC output
A special semiconductor element (TRIAC)
in the output stage of the opto-coupler is
used to switch AC voltages.
As for the DC-versions the appropriate
parameters (such as voltage, frequency,
max. load current, ambient temperature)
should be given consideration.
A neutral voltage switch ensures that the
load is switched only in the voltage zero.
To protect against voltage spikes, the
modules are allways fitted with appropriate
protection elements (varistors, RC-combi-
nation).
Inputs PLC PLC
Inputs
Opto-coupler outputOpto-coupler output
Opto-coupler inputOptoc-oupler input
Sample circuit
Protection
Protection
LoadLoad
Zero voltage switch
Actuator, e. g.
solenoid
Namur-
initiator
108
Types of housing for opto-coupler
Weidmüller coupler modules are enclosed
in housings that are appropriate for
industrial applications. The housings are
suitable for fitting onto mounting rails
TS 32, TS 35 x 7.5 or TS 35 x 15 in
accordance with European Standards
EN 50 035 and EN 50 022.
Component housing EG
Weidmüller component housings EG 1
and EG 2 are 18 mm wide. The fully
enclosed EG housings are fitted with
clamping yoke screw connections or
push-on blade connectors for attaching
wires. Conductors with the following
cross-sectional dimensions can be con-
nected:
solid conductors: 0.5…4 mm2or
flexible conductors: 0.5…2.5 mm2.
The component housing EG 7 has a spe-
cial status. Is has been specifically
designed to accommodate 10-mm slim
opto-couplers.
EG 7 opto-coupler modules can be
mounted onto TS 32 or TS 35 rails.
The RS EG7 locking socket is also avail-
able for the OST opto-couplers.
The fully-enclosed EG 7 housing is fitted
with clamping yoke connections.
Conductors with the following cross-
sections can be connected:
Component housing EG7: 0.5…1.5 mm2
Locking socket: 0.5…2.5 mm2.
Component Housing WAVEBOX
Component housing WAVEBOX
It is important for modern electronics to
create a functional housing. Setting and
operating functions must be guaranteed,
technical demands regarding heat dissipa-
tion and EMC properties are to be sup-
ported. The ideal design saves space and
mounting costs in the switchgear cabinet.
Moreover, ergonomics and the design are
gaining in importance for high-quality
opto-couplers interfaces. The WAVEBOX
fulfils these criteria and has the following
distinguishing features:
The WAVEBOX is characterised by:
Optimal width for any application
(12.5 mm, 17.5 mm, 22.5 mm)
Large component assembly surface;
SMD’s can be mounted on the solder
side
No tools required for assembly
Plug-in printed circuit board
Plug-in cross-connection via ZQV 2.5 N
Hinged, transparent cover
BLZ 5.08 screw/plug and socket
connector
BLFZ 5.08 optional tension clamp/plug
and socket connector
Marking option with WS tags
Suitable for snap-fitting on TS 35
Connection systems
Available are BLZ screw-type connectors
as well as the BLZF tension clamp system
for up to 2.5 mm2flexible conductors for
maximum wiring flexibility.
Printed-circuit board removal
This takes place by pushing in the locking
hooks in way of the cover and with draw-
ing of the terminal level and printed circuit
board from the housing. This must not
take place with the supply connected.
Cross-connection
Housings of the same family arranged side
by side, can be cross-connected in the
base of the housing with the ZQV 2.5 N/2
cross-connector. The cross-connection
can be loaded with a current of up to 8 A.
By means of this arrangement, the supply
voltage can be cross-connected from one
electronic module to another. The voltage
transferred from the cross-connection to
the terminal level must not exceed 50 V.
Air vents
Slanted air vents control the temperature
and ventilate the housing base.
Modular system
PLUGSERIES/PLUGOPTO
is a new generation of pluggable SSR.
The core is an innovative relay socket
PXS or PXZ.
Both products combine Weidmüller
functionality and experience gained from
the relay and terminal business.
The PLUGopto is the ideal connection
technology between SSR and the
application.
Modular principle
The new PLUGSERIES is particularly ser-
vice friendly. Commercially available SSRs
are simply plugged: holding / dismounting
clamps guarantee secure mounting; LED
indicators with free-wheeling diode can be
simply plugged.
Easy plugging of SSR
-suitable for the standard design
and RT
Independent connection technology:
screw or tension clamp
Rated cross-section 0.5 2.5 mm2
Robust holding / dismounting clamp
Control voltage 24 Vac/Vdc
Rated switching voltage 24 Vdc, 24
Vac/Vdc, 230 Vac
Up to 5 A continuous current
Low wiring costs thanks to ZQV 2.5N
(pluggable) cross-connectors
Service-friendly modular system
-relay socket, LED indicator
-holding clamp and SSR
-mount onto TS 35
-marking options with WS marking
tags and holding clamps
Pluggable LED indicator with free-wheel-
ing diode
109
Digital signal
processing
Weidmüller locking socket RS
The locking socket with opto-couplers RS
40 have a width of 11.2 mm. The modules
on locking socket profiles are equipped
with clamping yoke (screw connection)
units for conductor connection.
Connectable are:
solid conductors: 0.5…4 mm2
flexible conductors: 0.5…2.5 mm2.
Locking socket with multiple
interfaces
Multiple interfaces RSM are optionally
available assembled with 4, 8 or 16 plug-
gable opto-couplers. Versions are avail-
able with joint positive and negative poten-
tials in order to reduce wiring on the input
side.
PCB clamping yoke screw connecter ele-
ments have clamping yoke units for con-
necting conductors with the following
cross-sections:
solid conductors: 0.5...4 mm2
flexible conductors: 0.5...2.5 mm2
Variants of the RSM couplers have male
connector blocks on the input side for
connecting pre-assembled cables, in
accordance with IEC 603-1/DIN 41651.
Mini-coupler
All parts of the mini-coupler DKR and DKO
meet the specifications for a design that is
as slim as possible. The sensational width
of a mere 6 mm can be achieved by
employing the latest surface-mounted
devices (SMD). There are 4 or 5 screw
connections available which accept
conductors with cross-sectional
dimensions from 0.5…4 mm2. The mini-
coupler offer a wide range of options for
coupling digital sensor/actuator signals
between automation devices and the
process stage. With DKO opto-coupler,
signals from the field with different volt-
ages can be picked up and unified.
Miniconditioner MCZ
The MCZ-housing is distinguished as one
of the slimest component-housings. A tool
width of only 6 mm reduces space
requirements in cabinets.
The MCZ is characterized by:
- Tension-clamp connection
- integrated cross-connection option for
input and output minimise wiring costs.
The mini conditioner MCZO (opto-cou-
plers) have 4 and 5 Z-tension spring con-
nections. The clampable conductor cross-
section is 0.5...1.5 mm2.
CE-marking
Weidmüller opto-coupler are marked with
the CE symbol and comply with the
requirements of
EN 50 081 Part 1 and EN 50 082 Part 2.
They can therefore be used for both
industrial as well as for commercial and
light industry.
Appropriate ESD measures should be
taken during installation. If connecting
wires are particularly long, overvoltage
protection should be provided in order to
prevent interference from electrical
disturbance in the atmosphere.
24 V
5 - 48 V 5 - 48 V 5 - 48 V 5 - 48 V 5 - 48 V 5 - 48 V 24 - 250 V 5 - 48 V 5 - 48 V 5 - 48 V
Housing 20 mA 0.1 A 0.5 A 20 mA 2.5 A 5 A 3.5 A 0.1 A 0.1 A 0.1 A
EG 0558160000 0609860000 8220870000
Page 122 Page 123 Page 130
WAVESERIES 8275190000 8237720000
WOS Page 126 Page 128
EG 7 8269050000 8281720000
Page 131 Page 131
8092530000
8234580000
Page 132
RS 40 1160961001 1117461001
1161761001 8065031001
1177860000 1119460000
Page 137 Page 137
RSM 1123861001 1124261001 1124661001
1123761001 1125261001 8018220000
1125161001 8003671001 1124900000
8017581001 1124900000 1170200000
1124900000 1170200000 1153200000
1170200000 1153200000 1121300000
1153200000 1121300000 8082471001
1121300000 8021391001 1124900000
Page 139 1124900000 1170200000
1170200000 1153200000
1153200000 1121300000
1121300000 Page 139
Page 139
DKO 32 8008090000 8019580000
Page 116 Page 117
DKO 35 8008150000 8019590000 8215600000
Page 116 Page 117 8181990000
8028300000 8215630000 Page 118
8215640000 Page 118
8248790000
Page 117
DKO 35/32 8228640000 8228630000
Page 119 Page 118
MCZ O 8365940000 8398940000 8287730000
Page 114 Page 115 Page 114
8324610000
(5 V TTL)
Page 115
PLUGSERIES 8610840000 8610860000
POS/POZ 8610920000 8610930000
8610900000 8610910000
8610970000 8610980000
8610890000 8615590000
8610960000 8615630000
8615600000 Page 134
8615640000
8615620000
8615650000
Page 134
110
Opto-coupler
Output
4 x 8 x 16 x
Reliable
separation
24 V dc
24 Vuc/ac
Electronic switching
Replacement opto-coupler dc and ac/dc
Empty socket
115 V
5 - 48 V 5 - 48 V 5 - 48 V 5 - 48 V 5 - 48 V 5 - 48 V 24 - 250 V 5 - 48 V 5 - 48 V 5 - 48 V
Housing 20 mA 0.1 A 0.5 A 20 mA 2.5 A 5 A 3.5 A 0.1 A 0.1 A 0.1 A
EG 0131860000
Page 123
WAVESERIES 8235180000 8296250000 8259950000 8275360000
WOS Page 125 Page 126 Page 127 Page 128
EG 7 8092570000
8234600000
8397420000
8315590000
Page 133
RS 40 1161161001
1161960000
Page 137
DKO 32 8027980000
Page 119
DKO 35 8077860000
Page 119
8131660000
Page 120
MCZ O 8421060000
Page 114
Digital signal
processing
111
48 V
5 - 48 V 5 - 48 V 5 - 48 V 5 - 48 V 5 - 48 V 5 - 48 V 24 - 250 V 5 - 48 V 5 - 48 V 5 - 48 V
Housing 20 mA 0.1 A 0.5 A 20 mA 2.5 A 5 A 3.5 A 0.1 A 0.1 A 0.1 A
EG 7 8092550000
Page 132
8234590000
Page 132
RS 40 1161061001
Page 137
1161860000
Page 137
DKO 35 8151230000
Page 120
Opto-coupler
Output
4 x 8 x 16 x
4 x 8 x 16 x
Reliable
separation
Vdc
Vuc/ac
Electronic switching
4 x 8 x 16 x
4 x 8 x 16 x
Output
230 V
5 - 48 V 5 - 48 V 5 - 48 V 5 - 48 V 5 - 48 V 5 - 48 V 24 - 250 V 5 - 48 V 5 - 48 V 5 - 48 V
Housing 20 mA 0.1 A 0.5 A 20 mA 2.5 A 5 A 3.5 A 0.1 A 0.1 A 0.1 A
EG 0546360000
Page 123
WAVESERIES 8275380000 8275220000 8275400000 8275340000
WOS Page 125 Page 126 Page 127 Page 128
EG 7 8092590000
8234610000
8387580000
8394990000
Page 133
RS 40 1161461001
1162060000
8182690000
Page 137
DKO 32 8008100000
Page 119
DKO 35 8008160000
Page 119
MCZ O 8421380000
Page 114
112
Opto-coupler
Output
4 x 8 x 16 x
230 Vuc/ac
Electronic switching
4 x 8 x 16 x
12 V
5 - 48 V 5 - 48 V 5 - 48 V 5 - 48 V 5 - 48 V 5 - 48 V 24 - 250 V 5 - 48 V 5 - 48 V 5 - 48 V
Housing 20 mA 0.1 A 0.5 A 20 mA 2.5 A 5 A 3.5 A 0.1 A 0.1 A 0.1 A
EGO 8011250000 0114260000
Page 122 Page 122
WAVESERIES 8275500000
WOS Page 124
EGO 7 8092510000
8234570000
Page 132
RS 40 1118760000
1161660000
Page 137
RSM O 8017581001 8003671001 8018221001
1121200000 1121200000 1121200000
1124800000 1124800000 1124800000
Page 139 8021391001 8082471001
1121200000 1121200000
1124800000 1124800000
Page 139 Page 139
DKO 35 8184030000
Page 116
113
Digital signal
processing
3…60 V
EGO, 3…5 V 0266160000
Page 122
EGO, 3…12 V 8011250000
Page 122
WAVESERIES 8275430000
WOS 5 V Page 124
WAVESERIES 8275210000
WOS 5 V TTL Page 129
WAVESERIES 8275390000
WOS 3.5 - 15 V Page 124
WAVESERIES 8275450000
WOS 12 - 28 V Page 129
WAVESERIES 8237730000 8237730000 8275440000
WOS 15 - 60 V Page 124 Page 124 Page 127
EGO, 7.5 V 8092490000
8234560000
Page 132
RS 40, 5 V 1118861001
1161560000
Page 137
RSM, 5 V 1123661001 1124061001 1124461001
1121100000 1121100000 1121100000
Page 139 Page 139 Page 139
DKO 32 8018620000
Page 116
DKO 35 8018630000 8067100000
Page 116 Page 120
DKO 32/35 8228650000
Page 116
Opto-coupler
Output
4 x 8 x 16 x
Electronic switching
4 x 8 x 16 x
Reliable
separation
12 Vdc
12 Vuc/ac
Replacement opto-coupler dc and ac/dc
Empty socket
114
MCZ O
120 Vac/dc
MCZ O
24 Vac/dc 20 mA MCZ O
24 Vac/dc 2 A2* MCZ O
230 Vac
Schematic circuit diagram
Ordering data
For TS 35
Technical data
Input
Input voltage
Making threshold
Input current at Unom
Rated input consumption
Max. input frequency
Capacity working resistance to reduction at dissipated energy
Functionality
Output
Supply voltage
Max. output current
Voltage drop at max. load current
Pulse duration, limiting overload current (not periodic)
Reverse current (close-circuit current) at Uout = 48 V
Reverse polarity protection
Free-wheel diode
- typ. Switch-on delay (at ac phase position dependent)
- typ. Switch-off delay (at ac phase position dependent)
Short-circuit proof
Insulation coordin./Reliable separation acc. to EN 50 178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
Insulation coordin.- and voltage proof, input/output mounting rail
Opto-coupler
Ambient temperature rowed on mounting rail without clearances
Ambient temperature rowed with clearances 20 mm
Storage temperature
Conductor
Conductor cross-section
Approvals
Overall width
Accessories
End plate
Further accessories, dimensions and connection data
Opto-coupler in component housing mini coupler MCZ
This module can be used:
• between controller and sensor, for feedback of
different statuses.
• for direct switching of load currents up to a Adc, but
also provides “online” information about the
behaviour of the load current.
The MCZ-O modules do have following features:
• Reduction of installation- and power-up times by
using the proved tension-clamp technology
• Pluggable cross-connection units in the input side
reduce wiring costs
• 6 mm width
Type Cat. No.
MCZ O 24 Vac/dc
8287730000
24 Vac/dc ±20 % (19.2...28.8ac/dc)
approx.16 Vac/dc
ac: 13 mA / dc: 12 mA
ac: approx.220 mW
dc: ca.195 mW
ac: 10 Hz duty factor 1:2
dc: 30 Hz duty factor 1:2
no
operating indication
24 Vdc ±20 % (19.2...28.8 Vdc)
2 A
present
external necessary
yes
300 V
6 kV
III
2
5.5 mm
4 kVeff / 1 min
acc. to VDE 0884
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type Cat. No.
AP MCZ 1.5 8389030000
Page 305
Type Cat. No.
MCZ O 24 Vac/dc
8365940000
24 Vac/dc ±10 % (21.6...26.4ac/dc)
ac: 14.1 Vac / dc: 16.8 Vdc
ac: 11.4 mA / dc: 9.6 mA
ac: 5 Hz duty factor 1:2
dc: 10 Hz duty factor 1:2
no
operating indication
5...48 Vdc
20 mA
1 V
< 150 mA / 10 ms
max. 0.16 mA
present
ac: 10 ms / dc: 20 ms
ac: 45 ms / dc: 40 ms
300 V
6 kV
III
2
5.5 mm
4 kVeff / 1 min
acc. to VDE 0884
-25 °C…+50 °C
-40 °C...+85 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type Cat. No.
AP MCZ 1.5 8389030000
Page 305
Type Cat. No.
MCZ O 120 Vac/dc
8421060000
120 Vac/dc -15 % +5 %
approx.65 Vac/approx.70 Vdc
approx.3 mA
ac: 5 Hz duty factor 1:2
dc: 20 Hz duty factor 1:2
no
operating indication
5...48 Vdc
50 mA
< 1.6 V
< 150 mA / 10 ms
max.0.16 mA
present
30 ms
40 ms
300 V
6 kV
III
2
5.5 mm
4 kVeff / 1 min
acc. to VDE 0884
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type Cat. No.
AP MCZ 1.5 8389030000
Page 305
Type Cat. No.
MCZ O 230 Vac
8421380000
230 Vac -15 % +5 %
approx.170 Vac
ac: 10 mA
ac: 5 Hz duty factor 1:2
yes
operating indication
5...48 Vdc
20 mA
< 1.6 V
< 150 mA / 10 ms
max.0.16 mA
present
300 V
6 kV
III
2
3 mm
4 kVeff / 1 min
acc. to VDE 0884
-25 °C…+50 °C
-40 °C...+85 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type Cat. No.
AP MCZ 1.5 8389030000
Page 305
50°C
20 mA
40 50 °C
2 A
50 mA
50°C
20 mA
Ambient temperature
Derating curve
rated to ambient temperature
a = rowed without clearances on the mounting rail
b = rowed with clearances 20 mm
Output current
26.4 Vac/dc
a+b at Uin
28 Vac/dc
241.50 Vac
126 Vac/dc
b
a
40 50 °C
b
a
Opto-couplers MCZ O
115
Digital signal
processing
MCZ O
24 Vdc/5 VTTL1*
MCZ O
5 V TTL/5...48 Vdc2*
Type Cat. No.
MCZ O 24 Vdc 8324610000
24 Vdc ±16 % (20…28 Vdc)
approx.17 Vdc
4.7 mA (2.9.2..6.5 mA)
dc: 112 mW
100 kHz switching ratio 1:2
50 kHz switching ratio 1:10
2 µs
5 V (4.75...5.25 V)
5 V TTL (4.75...5.25 V)
8 mA, Fan Out = 20 LS-TTL
1 µs (at 20 Vdc)
2.5 µs (at 28 Vdc)
300 V
6 kV
III
2
5.5 mm
4 kVeff / 1 min
acc. to VDE 0884
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C...+60 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type Cat. No.
AP MCZ 1.5 8389030000
Page 305
Schematic circuit diagram
Ordering data
For TS 35
Technical data
Input
Supply voltage
Input voltage
Making threshold
Input current at Unom
Rated input consumption
Max. input frequency
Min. input impulse width
Output
Supply voltage
Output voltage
Max. output current
Voltage drop at max. load current
Pulse duration, limiting overload current (not periodic)
Reverse current (static current) at Uout = 48 V
Reverse polarity protection
Free-wheel diode
- typ. switch-on delay
- typ. switch-off delay
Insulation coordin./Reliable separation acc. to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
Insulation coordination/dielectric strength I/O to TS
Opto-coupler
Ambient temperature rowed on mounting rail without clearances
Ambient temperature rowed with clearances 20 mm
Storage temperature
Conductor
Conductor cross-section
Approvals
Overall width
Accessories
End plate
Further accessories, dimensions and connection data
Opto-coupler in component housing mini coupler MCZ
Type Cat. No.
MCZ O 24 Vdc 8398940000
5 Vdc ± 5 %
5 V TTL
IIL = 1 µA / IIH = 8 µA
2.4 kHz
5...48 Vdc
100 mA
1.8 V
present (input)
present
approx.27 µs
approx.210 µs
300 V
6 kV
III
2
5.5 mm
4 kVeff / 1 min
acc. to VDE 0884
-25 °C…+50 °C
-25 °C…+50 °C
-40 °C...+85 °C
AWG 22...12
1.5 mm2
CE, UL, CSA
6 mm
Type Cat. No.
AP MCZ 1.5 8389030000
Page 305
2 µs
2.5 µs
1µs
Input signal
at 832461
Output signal
8 mA
Ambient temperature
Derating curve
rated to ambient temperature
a = rowed on the mounting rail without clearances
b = rowed with clearances 20 mm
Output current
a+b at Uin
28.8 Vdc 100 mA
5.25 Vdc
40 50 °C
b
a
40 50 °C
b
a
Opto-couplers MCZ O
This module can be used:
1* - between controller and actuator, for the signal
conversion of
24 Vdc to 5 VTTL
2* - between controller and actuator, for the signal
conversion of
5 VTTL to 5...48 Vdc
116
Ordering data
For TS 32 Y
For TS 35 W
With combination foot TS 32/TS 35
Technical data
Input voltage
Switch-on voltage
Input current
Max. input power
Output voltage
Max. output current
Min. output current
Max. switching frequency; switching ratio 1: 2
Switch-on delay
Switch-off delay
Voltage drop at max. load
Insulation coordination to EN 50 178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
Operating temperature without clearances
with clearances
Storage temperature
Conductor
Conductor cross-section
Overall width
Accessories
End plate
Further accessories, dimensions and connection data
Opto-couplers DKO
• Coupling of digital sensor-/actuator-signals between
PLC and process
Low cost solution for level- and potential-equalization
• Low input power
• Screw clamp connection technology
• 6 mm width
Type Cat. No.
DKO DK5 5 VTTL 8228650000
Input: bottom
5 VTTL
1 µA
5…48 Vdc
100 mA
50 µA
3 kHz
approx.27 µs
approx.35 µs
1.6 V
300 V
6 kV
IV
2
5.5 mm
-25 °C…+50 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DK5 8268870000
Page 305
Type Cat. No.
DKO 12 Vdc 8184030000
Input: bottom
12 Vdc ±20 %
approx.7 V
11 mA
130 mW
24 Vdc ±10 %
50 mA
50 µA
10 kHz
1 µs
2.5 µs
1 V
300 V
6 kV
IV
2
5.5 mm
-25 °C…+50 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
12 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
Type Cat. No.
DKO 24 Vac/dc 8008090000
DKO 24 Vac/dc 8008150000
Input: bottom
24 Vac/dc ±10 %
112.8 Vac/16.8 Vdc
11.4 mAac/9.6 mAdc
280 mVA/230 mW
5…48 Vdc
20 mA
50 µA
ac: 5 Hz dc: 10 Hz
15 ms at dc
25 ms at dc
1 V
300 V
4 kV
III
2
4 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
Type Cat. No.
DKO 5 Vdc 8018620000
DKO 5 Vdc 8018630000
Input: bottom
5 Vdc ±5 %
2.4 Vdc
10 mA
50 mW
5…48 Vdc
20 mA
50 µA
20 Hz
15 µs
70 µs
1.6 V
150 V
4 kV
IV
2
4 mm
-25 °C…+50 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
DKO 5 Vdc DKO 5 VTTL DKO 12 Vdc DKO 24 Vac/dc
Schematic circuit diagram
Switching ratio
Switching ratio
Opto-coupler in component housing mini coupler DK
117
Digital signal
processing
Ordering data
For TS 32 Y
For TS 35 W
Technical data
Input voltage
Switch-on voltage
Input current
Max. input power
Output voltage
Max. output current
Min. output current
Max. switching frequency; switching ratio 1: 2
Switch-on delay
Switch-off delay
Voltage drop at max. load
Insulation coordination to EN 50 178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
Operating temperature without clearances
with clearances
Storage temperature
Conductor
Conductor cross-section
Overall width
Accessories
End plate
Further accessories, dimensions and connection data
Type Cat. No.
DKO 24 Vdc 8215640000
Input: bottom
24 Vdc ±10 %
approx.19 V/7.5 mA
15 mA
360 mW
5…48 Vdc
20 mA
50 µA
3 kHz
approx.50 µs
approx.80 µs
900 mV
300 V
4 kV
II
2
4 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
Type Cat. No.
DKO 24 Vdc 8028300000
Input: top
24 Vdc ±10 %
approx.19 V/7.5 mA
15 mA
360 mW
5…48 Vdc
20 mA
50 µA
3 kHz
approx.50 µs
approx.80 µs
900 mV
300 V
4 kV
II
2
4 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
Type Cat. No.
DKO 24 Vdc 8248790000
Input: bottom
24 Vdc ±10 %
approx.19 V/7.5 mA
8.5 mA
204 mW
5…48 Vdc
20 mA
50 µA
3 kHz
approx.50 µs
approx.80 µs
900 mV
300 V
4 kV
III
2
4 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
Type Cat. No.
DKO 24 Vdc 8019580000
DKO 24 Vdc 8019590000
Input: bottom
24 Vdc ±10 %
approx.17 V
6 mA
145 mW
5…48 Vdc
500 mA
50 µA
200 Hz
approx.40 µs
approx.65 µs
800 mV
300 V
4 kV
II
2
4 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
Opto-coupler in component housing mini coupler DK
DKO 24 Vdc DKO 24 Vdc DKO 24 Vdc DKO 24 Vdc
Schematic circuit diagram
Switching ratio
Switching ratio
Opto-couplers DKO
118
Ordering data
For TS 32 Y
For TS 35 W
With combination foot TS 32 / TS 35
Technical data
Input voltage
Switch-on voltage
Input current
Max. input power
Output voltage
Max. output current
Min. output current
Max. switching frequency; switching ratio 1: 2
Switch-on delay
Switch-off delay
Voltage drop at max. load
Insulation coordination to EN 50 178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
Operating temperature without clearances
with clearances
Storage temperature
Conductor
Conductor cross-section
Overall width
Accessories
End plate
Further accessories, dimensions and connection data
Type Cat. No.
DKO 24 Vdc 8215630000
Input: top
24 Vdc ±10 %
approx.17 Vdc
6 mA
145 mW
5…48 Vdc
500 mA
50 µA
200 Hz
approx.40 µs
approx.65 µs
800 mV
300 V
4 kV
III
2
4 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
Type Cat. No.
DKO 24 Vdc 8181990000
Input: bottom
24 Vdc ±10 %
approx.18 Vdc
12 mA
290 mW
24 Vdc ±10 %
2 A
100 Hz
300 V
4 kV
III
2
3 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
12 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
Type Cat. No.
DKO 24 Vdc 8215600000
Input: top
24 Vdc ±10 %
approx.18 Vdc
12 mA
290 mW
24 Vdc ±10 %
2 A
100 Hz
300 V
4 kV
III
2
3 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
12 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
Type Cat. No.
DKO 24 Vac/dc 8228630000
Input: bottom
24 Vac/dc ±20 %
approx.16 Vac/dc
13 mAac/12 mAdc
220 mVA/195 mW
24 Vdc ±20 %
2 A
ac: 10 Hz dc: 30 Hz
2 ms
7 ms
300 V
6 kV
IV
2
5.5 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DK 5 8268870000
Page 305
Opto-couplers DKO
• Coupling of digital sensor-/actuator-signals between
PLC and process
• Low cost solution for level- and potential-equalization
• Low input power
• Screw clamp connection technology
• 6 mm width
DKO 24 Vdc DKO 24 Vdc DKO 24 Vdc DKO 24 Vac/dc
Schematic circuit diagram
Switching ratio
Switching ratio
Opto-coupler in component housing mini coupler DK
Mode: green Load current 500mA
yellow Idling
red Short circuit
119
Digital signal
processing
Type Cat. No.
DKO 24 Vdc 8228640000
Input: top
24 Vdc ±20 %
approx.17 Vdc
4.7 mA
112 mW
5 VTTL
8 mA, Fan Out = 20 LS-TTL
100 kHz 1:2/50 kHz 1:10
1 µs
2.5 µs
300 V
4 kV
III
2
5.5 mm
-25 °C…+40 °C
-25 °C…+50 °C
-25 °C…+85 °C
AWG 22…12
0.5…4mm2
6 mm
Type Cat. No.
AP DK5 8268870000
Page 305
Type Cat. No.
DKO 230 Vac/dc 8008100000
DKO 230 Vac/dc 8008160000
Input: bottom
230 Vac/dc +5 % -15 %
approx.130 Vac/approx.140 Vdc
1.8 mAac/1.7 mAdc
395 mVA/370 mW
5…48 Vdc
20 mA
50 µA
ac: 5 Hz/dc: 20 Hz
20 ms
20 ms
<1.6 V
300 V
4 KV
III
2
3 mm
-25 °C…+50 °C
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
Type Cat. No.
DKO 115 Vac/dc 8027980000
DKO 115 Vac/dc 8077860000
Input: bottom
115 Vac/dc +5 % -15 %
approx.65 Vac/approx.66 Vdc
2.65 mAac/3 mAdc
390 mVA/350 mW
5…48 Vdc
50 mA
ac: 5 Hz/dc: 20 Hz
17.4 ms
27.4 ms
<1.6 V
300 V
6 kV
IV
2
5.5 mm
-25 °C…+40 °C
-25 °C…+50 °C
- 40 °C…+85 °C
AWG 22..12
0.5…4 mm2
6 mm
Type Cat. No.
AP DKT4 0687560000
Page 305
Ordering data
For TS 32 Y
For TS 35 W
With combination foot TS 32/TS 35
Technical data
Input voltage
Switch-on voltage
Input current
Max. input power
Output voltage
Max. output current
Min. output current
Max. switching frequency; switching ratio 1: 2
Switch-on delay
Switch-off delay
Voltage drop at max. load
Insulation coordination to EN 50 178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
Operating temperature without clearances
with clearances
Storage temperature
Conductor
Conductor cross-section
Overall width
Accessories
End plate
Further accessories, dimensions and connection data
Opto-coupler in component housing mini coupler DK
DKO DK5 24 Vdc DKO 115 Vac/dc DKO 230 Vac/dc
Schematic circuit diagram
Switching ratio
Switching ratio
Opto-couplers DKO
120
Ordering data
For TS 32 Y
For TS 35 W
With combination foot TS 32 / TS 35
Technical data
Input voltage
Input current
Input nominal power
Total power loss
Making threshold
Input reverse voltage
Output voltage
Output current
Voltage drop at max. load
Feature of output circuit
Indication
Dielectric strength input/output
Dielectric strength to mounting rail
Clearances and creepage distances
Operating temperature
Storage temperature
Conductor
Conductor cross-section
Overall width
Accessories
End plate
Type Cat. No.
DKO 35 48 Vdc 8151230000
48 Vdc ±10 %
3.7 mA ±20 %
178 mW
400 mW
approx.32 Vdc
max. 1 kV
5…28 Vdc
max. 20 mA
1.6 V
Disconnection plug
LED red
3.75 kVeff / 5.3 kVdc
4 kVeff
>5 mm
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DKT4 0687560000
Opto-coupler in component housing mini coupler DK
DKO 35 48 Vdc DKO 35 60 Vdc DKO 35 125 Vdc
Type Cat. No.
DKO 35 60 Vdc 8067100000
60 Vdc ±10 %
5.6 mA ±20 %
340 mW
420 mW
approx.42 Vdc / 5.3 mA
max. 1 kV
5…48 Vdc
max. 100 mA
0.8 V
LED green
3.75 kVeff / 5.3 kVdc
4 kVeff
>4 mm
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DKT4 0687560000
Type Cat. No.
DKO 35 125 Vdc 8131660000
125 Vdc ±10 %
1.7 mA ±20 %
215 mW
400 mW
approx.80 Vdc
max. 1 kV
5…28 Vdc
max. 20 mA
1.6 V
Disconnection plug
LED red
3.75 kVeff / 5.3 kVdc
4 kVeff
>5 mm
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
6 mm
Type Cat. No.
AP DKT4 0687560000
W
Schematic circuit diagram
Opto-couplers DKO
121
Digital signal
processing
Ordering data
For TS 32 Y
For TS 35 W
With combination foot TS 32 / TS 35
Technical data
Input
Input voltage
Input current
Pulse generator
Output
Output voltage
Output current
Voltage proof input-output/mounting rail
Insulation coordination to DIN VDE 0160, Draft 11/94
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
Operating temperature without clearances
with clearances
Storage temperature
Conductor
Conductor cross-section
Overall width
Accessories
End plate
Type Cat. No.
DKO DK4 S0 8467030000
DKO DK4 S0 8100180000
24 Vdc ±10 %
13 mA
Specification acc. to DIN
43864 (current interface for
connection to pulse generator
acc. to DIN 43864)
5…48 Vdc
max. 100 mA
4 kVeff
300 V
6 kV
IV
2
5.5 mm
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
12 mm
Type Cat. No.
AP DKT4 0687560000
Opto-couplers DKO
S0 signal sensor DKO switching amplifiers/opto-couplers for Namur initiators
DKO DK4 S0 DKO
Application example:
Signals for consumers are normally transferred
via an interface. Generally, this interface must
conform with DIN 43867 (interface for signal
transmission). There must be a differentiation
between the passive interface and active S0
interface. The actual signals, that are corres-
pondingly proportional to the relevant con-
sumption (electrical energy, gas consumption,
water, district heating, etc.) are shown at
measuring sensors (electric meter, etc.) The
interface itself is purely passive (acceptor) and
must be supplied via a source. The source for
providing the current is built into the active
interface. The following threshold values are
specified: Imax = 27 mAdc
Umax = 27 Vdc
fmax = 16.66 Hz
For the recognition of the corresponding con-
sumption signals, the following currents are
integrated: ON (active) -> 10…27 mA
Off (inactive) -> 0…2 mA
The module accepts the input from the signal
sensor and outputs the opto-decoupled output
signal, i. e. galvanically isolated.
Type Cat. No.
DKO 8164250000
24 Vdc ±20 %
35 mA
up to 1 kV available
300 Hz f. pulse duty factor 1:1
approx.45 µs
approx.450 µs
approx.18 V
ca 15 V
< 5 mA
300 Hz f. pulse duty factor 1:1
approx.20µs
approx.400 µs
5…30 Vdc
max. 100 mA
max. 3 W
max. 1 V
Free-wheel. diode btwn. A+…A-
4 kVeff
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+60 °C
AWG 22…12
0.5…4 mm2
12 mm
Type Cat. No.
AP DKT4 0687560000
Ordering data
For TS 32 Y
For TS 35 W
With combination foot TS 32 / TS 35
Technical data
Input
Input voltage
Input current
Reverse polarity protection
NAMUR-Input (N+ and N-)
Switching frequency
Switch-on delay
Switch-off delay
Input (E+ and 0)
Switch-on point
Switch off-point
Current consumption
Max. switching frequency
Switch-on delay
Switch-off delay
Output (A+ and A-)
Output voltage
Output current
Switching capacity
Internal voltage drop
Protective measure
Voltage proof input-output/mounting rail
Operating temperature without clearances
with clearances
Storage temperature
Conductor
Conductor cross-section
Overall width
Accessories
End plate
W
Schematic circuit diagram Schematic circuit diagram
Opto-coupler in component housing mini coupler DK
Type Cat. No.
EGO 1, 5 V 0266160000
3…5 V–2)
9…45 mW
5…48 V–1)
<1 V
20 mA
0.2 A/10 ms
0.16 mA
12 µs
180 µs
100 Hz
1 : 2
–40 °C…+60 °C
–25 °C…+60 °C
–25 °C…+60 °C
III
2
Page 306, Fig. I
Type Cat. No.
EGO 1, 12 V 80112500003)
3…12 V–
30…280 mW
5…48 V–1)
<1 V
20 mA
0.2 A/10 ms
0.16 mA
22 µs
44 µs
5000 Hz/5000 Hz
1 : 2/1 : 4
50 µs
–40 °C…+85 °C
–25 °C…+60 °C
–25 °C…+60 °C
III
2
Page 306, Fig. I
Type Cat. No.
EGO 1, 12 V 0114260000
12 V0, ±10 %
0.35 W
0.45 VA
5…48 V–1)
<1.6 V
100 mA
0.8 A/10 ms
0.16 mA
6 ms
13 ms
20 Hz
<10 Hz
1 : 2
–40 °C…+85 °C
–25 °C…+60 °C
–25 °C…+60 °C
III
2
Page 306, Fig. I
Type Cat. No.
EGO 1, 24 V 0558160000
24 V–, ±10 %
0.6 W
5…48 V–1)
<1 V
20 mA
0.2 A/10 ms
0.16 mA
30 µs
100 µs
3000 Hz
1 : 2
–40 °C…+85 °C
–25 °C…+60 °C
–25 °C…+60 °C
III
2
Page 306, Fig. I
Ordering data
Rated data
Input voltage
Rated consumption – (W)
Rated consumption ~ (VA)
Output supply voltage
Voltage drop at max. load current
Output current
Derating curve
a = mounted on rail without clearance
b = mounted on rail without clearance 20 mm
Continuous
current
Ambient temperature
Impulse loading, max. current (not periodic)
Max. reverse current (quiescent current) at U = 48 V
Switch-on time (cyclic operation)
Switching-off time (cyclic operation)
Max. switching frequency, DC
Max. switching frequency, AC
Switching ratio
Min. input impulse width
Storage temperature
Ambient temperature
–, rowed on mounting rail without clearances
–, rowed with clearances 20 mm
Insulation coordination to EN 50 178
Overvoltage category
Pollution severity
Accessories, dimensions and connection data see
122
Schematic circuit diagram
EGO 1 5 V
For low voltage
alternatively positive
or negative switching
EGO 1 5 V EGO 1 12 V EGO 1 24 V
Opto-coupler in component housing EG
t1= t2
* Wiring option
Switching ratio
Switching ratiot1= 1= 1 : 2
t32
1) Not TTL-compatible 3) At Ue 5 V, the LED only lights weakly or not at all.
2) Conditionally level-compatible Output switching function is not affected.
Opto-couplers EGO
Type Cat. No.
EGO 2, 115 V00131860000
117 V0, ±10 %
0.8 W
0.9 VA
5…48 V–
<1.6 V
100 mA
0.8 A/10 ms
0.16 mA
5 ms
22 ms
20 Hz
< 10 Hz
1 : 2
–40 °C…+85 °C
–25 °C…+40 °C
–25 °C…+50 °C
III
2
Page 306, Fig. I
Type Cat. No.
EGO 2, 230 V00546360000
230 V0, +5 %-15 %
1.2 W
1.4 VA
5…48 V–
<1.6 V
100 mA
0.8 A/10 ms
0.16 mA
13 ms
10 ms
20 Hz
< 10 Hz
1 : 2
–40 °C…+85 °C
–25 °C…+40 °C
–25 °C…+50 °C
III
2
Page 306, Fig. I
Type Cat. No.
EGO 1, 24 V 0609860000
24 V0, ±10 %
0.5 W
0.6 VA
5…48 V–1)
<1.6 V
100 mA
0.8 A/10 ms
0.16 mA
2 ms
15 ms
20 Hz
<10 Hz
1 : 2
–40 °C…+85 °C
–25 °C…+60 °C
–25 °C…+60 °C
III
2
Page 306, Fig. I
123
Digital signal
processing
EGO 2 115 V0
for low voltage
EGO 2 230 V0
In the case of inductive or capacitive electrical noise,
it is recommended to connect an RC network
(DK 4 RC)
upstream or to use EGO 3
.
EGO 1 24 V
Opto-coupler in component housing EG
* Wiring option
124
Type Cat. No.
WOS 1 15-60 Vdc 8237730000
WOZ 1 8430090000
15 Vdc...60 Vdc1)
1.4 mA at 15 V
2.5 mA at 24 V
4.1 mA at 48 V ...60 V
ca.12 V
approx.9 V
1 kHz
90 us
250 us
LED green in output
short-circuit protection
10 m A...0.6 A
max. 500 mA
12 Vdc...24 Vdc...28 Vdc
typ. 0.7 A ... 1.8 A
min.0.7 A; max. 2.4 A
0.5 V at 500 mA
Polarity protection, varistor
12 Vdc...24 Vdc...28 Vdc
yes / max. 96 h
-25 °C...+60 °C rowed
-40 °C...+85 °C
22.5 mm
Polyamide PA 66
UL/CSA
300 V
4 kV
III
2
5.5 mm
Page 298 + 308
WOS 1 15-60 VDC
Schematic circuit diagram
Type Cat. No.
WOS 1 5 Vdc 8275430000
WOZ 1 8430030000
4.0 Vdc...5 Vdc...6.0 Vdc
7.5 mA at 4.0 V
13.5 mA at 5.0 V
19.0 mA at 6.0 V
approx.2.2 V
approx.2.0 V
100 Hz
100 us
1 ms
LED green in input
negative switching
max. 2 A*
18 Vdc...24 Vdc...30 Vdc
300 mV
Varistor
no
-25 °C...+50 °C rowed
-40 °C...+85 °C
22.5 mm
Polyamide PA 66
UL/CSA
300 V
4 kV
III
2
5.5 mm
Page 298 + 308
Type Cat. No.
WOS 1 3.5-15 Vdc 8275390000
WOZ 1 8430040000
3.5 Vdc...15 Vdc
10.5 mA at 3.5.0 V
12.5 mA at 5.0 V
25.0 mA at 15 V
approx.2.5 V
approx.1.5 V
5 kHz
8 us
35 us
LED green in input
max. 100 mA
5 Vdc...48 Vdc
1.5 V at 100 mA
Varistor, integr. free-wh. diode
no
-25 °C...+60 °C rowed
-40 °C...+85 °C
22.5 mm
Polyamide PA 66
UL/CSA
300 V
4 kV
III
2
5.5 mm
Page 298 + 308
Type Cat. No.
WOS 1 12 Vuc 8275500000
WOZ 1 8429990000
10 Vdc...12 Vdc...14 Vdc
15.3 mA ac at 12 V
12.4 mA dc at 12 V
approx.8 V
approx.7 V
10 ms ac and 4 ms dc
20 ms ac and 18 ms dc
LED green in output
short-circuit protection
10 mA...0.6 A
max. 500 mA
12 Vdc...24 Vdc...28 Vdc
typ. 0.7 A ... 1.8 A
min. 0.7 A; max. 2.4 A
0.5 V, at 500 mA
Polarity protection, varistor
12Vdc...24Vdc...28Vdc
yes / max. 96 h
-25 °C...+60 °C rowed
-40 °C...+85 °C
22.5 mm
Polyamide PA 66
UL/CSA
300 V
4 kV
III
2
5.5 mm
Page 298 + 308
WOS 1 5 VDC
negative switching
WOS 1 3.5-15 VDC WOS 1 12 VUC
Ordering data
Screw connection
Tension clamp connection
Input
Input voltage
Input current
Making threshold
Breaking threshold
Input frequency
Switch-on delay
Switch-off delay
Status indicator
Output
Output current range
Nominal output current
Output voltage
Response threshold
Residual voltage
Protection circuit
Voltage supply
Short-circuit in output
Temperature
Operating temperature**
Storage temperature
Mechanical data
Overall width
Housing material
Approvals
Reliable separation according to EN 50 178
Coordination of insulation according to EN 50 178
Opto-coupler according to VDE 0884
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearance/creepage path
Accessories, dimensions and connection data see
* at ambient temperature 20 °C/horizontal installation
Opto-coupler in component housing WAVESERIES
1) Caution: Cross-connections may only be used for voltages 50 Vdc (extra-low voltage).
Opto-couplers WAVESERIES
Opto-coupler in WAVEBOX:
Independent connection technology
- pluggable connection unit optionally available with
screw or tension clamp connection technology
Fast commissioning and after-sales service
- pluggable replacement PCBs
Save wiring
- cross-connection option at input / output
Fast switching
- high frequency output, up to 100 kHz
Reliable power output
- short-circuit and overload proof
Space-saving components
- 4-channel opto-couplers
125
Digital signal
processing
Type Cat. No.
WOS 1 230 Vuc 8275380000
WOZ 1 8430050000
230 V, max. 250 Vuc
11.5 mA ac at 230 V
1.8 mA dc at 230 V
ca.170 V ac and 140 V dc
ca.130 V ac and 135 V dc
-
25 ms ac 15 ms dc
25 ms ac 20 ms dc
LED green in output
short-circuit protection
10 mA...0.6 A
max. 500 mA
12 Vdc...24 Vdc...28 Vdc
typ. 0.7 A ... 1.8 A
min.0.7 A; max. 2.4 A
0.5 V at 500 mA
Polarity protection, varistor
12 Vdc...24 Vdc...28 Vdc
yes / max. 96 h
-25 °C...+60 °C rowed
-40 °C...+85 °C
22.5 mm
Polyamide PA 66
UL/CSA
300 V
4 kV
III
2
5.5 mm
Page 298 + 308
Type Cat. No.
WOS 1 115 Vuc 8235180000
WOZ 1 8430100000
115 Vuc, max. 130 Vuc
3.1 mA ac at 115 V
2.9 mA dc at 115 V
ca.75 V ac and 71 dc
ca.70 Vuc
-
10 ms ac 10 ms dc
15 ms ac 15 ms dc
LED green in output
short-circuit protection
10 m A...0.6 A
max. 500 mA
12 Vdc...24 Vdc...28 Vdc
typ. 0.7 A ... 1.8 A
min.0.7 A; max. 2.4 A
0.5 V at 500 mA
Polarity protection, varistor
12 Vdc...24 Vdc...28 Vdc
yes / max. 96 h
-25 °C...+60 °C rowed
-40 °C...+85 °C
22.5 mm
Polyamide PA 66
UL/CSA
300 V
4 kV
III
2
5.5 mm
Page 298 + 308
WOS 1 115 VUC WOS 1 230 VUC
Schematic circuit diagram
Ordering data
Screw connection
Tension clamp connection
Input
Input voltage
Input current
Making threshold
Breaking threshold
Input frequency
Switch-on delay
Switch-off delay
Status indicator
Output
Output current range
Nominal output current
Output voltage
Response threshold
Residual voltage
Protection circuit
Voltage supply
Short-circuit in output
Temperature
Operating temperature**
Storage temperature
Mechanical data
Overall width
Housing material
Approvals
Reliable separation according to EN 50 178
Coordination of insulation according to EN 50 178
Opto-coupler according to VDE 0884
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearance/creepage path
Accessories, dimensions and connection data see
* at ambient temperature 20 °C/horizontal installation
Opto-coupler in component housing WAVESERIES
Opto-couplers WAVESERIES
WOS 1 230 VUC
waagerecht montiert; Ansteuerung : 253Vac
0
0,1
0,2
0,3
0,4
0,5
0,6
020406080100
Umgebungstemperatur [°C]
A
bstand>=10mm
WOS 1 230 VUC • 8275380000
Output current [A]
Mounted horizontally
Control 253 Vdc
Ambient temperature [°C]
mounted clearance
10 mm
126
Type Cat. No.
WOS 2 24 Vuc
8275190000
WOZ 2 8430080000
21.6 V...24 V...26.4 V
16.3 mA ac at 24 V
13.5 mA dc at 24 V
ca.16 V
ca.11 V
8 ms ac 7msdc
25 ms ac 25 ms dc
LED green in output
LED red in output*1)
min. 2 mA...max. 1.5 A at Tb
25 °C...150 °C
min. 2 mA...max. 1.9 A at Tb
-40 °C...25 °C
Tb: temperature in module
direct at output driver
BTS442
short-circuit protection
5 Adc*
approx.15 mA at 28.8 V
19.2 Vdc...24 Vdc...28.8 Vdc
max. 400 mV
Polarity protection, varistor
yes / max. 96 h
-25 °C...+50 °C rowed
-40 °C...+85 °C
22.5 mm
Polyamide PA 66
UL/CSA
300 V
4 kV
III
2
5.5 mm
Page 298 + 308
Type Cat. No.
WOS 2 115 Vuc
8296250000
WOZ 2 8429980000
115 V, max. 130 Vuc
3.1 mA ac at 115 V
2.8 mA dc at 115 V
ca.70 V
ca.55 V
10 ms ac 15 ms dc
30 ms ac 30 ms dc
LED green in output
LED red in output*1)
min. 2 mA...max. 1.5 A at Tb
25 °C...150 °C
min. 2 mA...max. 1.9 A at Tb
-40 °C...25 °C
Tb: temperature in module
direct at output driver
BTS442
short-circuit protection
5 Adc*
approx.15 mA at 28.8 V
19.2 Vdc...24 Vdc...28.8 Vdc
max. 400 mV
Polarity protection, varistor
yes / max. 96 h
-25 °C...+50 °C rowed
-40 °C...+85 °C
22.5 mm
Polyamide PA 66
UL/CSA
300 V
4 kV
III
2
5.5 mm
Page 298 + 308
Type Cat. No.
WOS 2 230 Vuc
8275220000
WOZ 2 8430060000
230 V, max. 250 Vuc
12.0 mA ac at 230 V
1.8 mA dc at 230 V
ca.140 V ca.100 V
ca.100 V ca.120 V
10 ms ac 15 ms dc
30 ms ac 30 ms dc
LED green in output
LED red in output*1)
min. 2 mA...max. 1.5 A at Tb
25 °C...150 °C
min. 2 mA...max. 1.9 A at Tb
-40 °C...25 °C
Tb: temperature in module
direct at output driver
BTS442
short-circuit protection
5 Adc*
approx.15 mA at 28.8 V
19.2 Vdc...24 Vdc...28.8 Vdc
max. 400 mV
Polarity protection, varistor
yes / max. 96 h
-25 °C...+50 °C rowed
-40 °C...+85 °C
22.5 mm
Polyamide PA 66
UL/CSA
300 V
4 kV
III
2
5.5 mm
Page 298 + 308
WOS 2 24 VUC WOS 2 115 VUC WOS 2 230 VUCOpto-couplers WAVESERIES
with power output
(short-circuit proof and overload proof)
Ordering data
Screw connection
Tension clamp connection
Input
Input voltage
Input current
Making threshold
Breaking threshold
Switch-on delay
Switch-off delay
Status indicator normal operation
Status indicator short-circuit, underload, overload
Underload
Output
Output current
Closed supply-circuit current (output not switched)
Voltage supply
Residual voltage
Protection circuit
Short-circuit in output
Temperature
Operating temperature**
Storage temperature
Mechanical data
Overall width
Housing material
Approvals
Reliable separation according to EN 50 178
Coordination of insulation according to EN 50 178
Opto-coupler according to VDE 0884
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearance/creepage path
Accessories, dimensions and connection data see
*at ambient temperature 20 °C/horizontal installation
*1) LED red:
hard short-circuit,
LED permanently lit.
The output is switched off and
does not reset itself. To reset,
the output or input must be
temporarily disconnected from
the supply voltage or input
signal.
Overload: LED cycles,
Rate: approx. 2 sec. on,
approx. 30 sec. off.
Module resets itself after the
overload is removed.
Underload: LED permanently
lit.
When an underload reco-
gnised, both LEDs are lit.
The output is switched
through
Schematic circuit diagram
Opto-coupler in component housing WAVESERIES
WOS 2 230 VUC
waagerecht montiert; Ansteuerung : 253Vac
Umgebungstemperatur [°C]
A
bstand>=10mm
WOS 2 230 VUC • 8275220000
Output current [A]
Ambient temperature [°C]
mounted
clearance
10 mm
Mounted horizontally
Control 253 Vdc
127
Digital signal
processing
Type Cat. No.
WOS 2 15-60 Vuc
8275440000
WOZ 2 8430010000
15 Vuc...60 Vac/66 Vdc
3.3 mA ac at 15 V
3.8 mA dc at 15 V
4.0 mA ac at 24 V
4.6 mA dc at 24 V
5.3 mA ac at 60 V
5.6 mA dc at 60 V
approx.11 V dc approx.15 V ac
approx.5 V dc approx.14 V ac
max. 20 ms
max. 20 ms
LED green in input
AC voltage output
max. 230 V/3.5 A ac*
2 mA
24 Vac...250Vac (50Hz-60Hz)
max. 1.6 V
RC-combination with varistor
-25 °C...+50 °C rowed
-40 °C...+85 °C
22.5 mm
Polyamide PA 66
UL/CSA
300 V
4 kV
III
2
5.5 mm
Page 298 + 308
Type Cat. No.
WOS 2 115 Vuc
8259950000
WOZ 2 8430160000
115 Vuc max. 130 Vuc
7.2 mA ac at 115 V
3.8 mA dc at 115 V
approx.90 V dc approx.90 V ac
approx.70 V dc approx.70 V ac
max. 20 ms
max. 20 ms
LED green in input
AC voltage output
max. 230 V/3.5 A ac*
2 mA
24Vac...250 Vac (50Hz-60Hz)
max. 1.6 V
RC-combination with varistor
-25 °C...+50 °C rowed
-40 °C...+85 °C
22.5 mm
Polyamide PA 66
UL/CSA
300 V
4 kV
III
2
5.5 mm
Page 298 + 308
Type Cat. No.
WOS 2 230 VUC
8275400000
WOZ 2 8430150000
230 Vuc max. 250 Vuc
11.8 mA ac at 230 V
3.3 mA dc at 230 V
approx.180 V dc approx.200 V ac
approx.150 V dc approx.140 V ac
max. 25 ms
max. 25 ms
LED green in input
AC voltage output
max. 230V/3.5A ac*
2 mA
24 Vac..250 Vac (50Hz-60Hz)
max. 1.6 V
RC-combination with varistor
-25 °C...+50 °C rowed
-40 °C...+85 °C
22.5 mm
Polyamide PA 66
UL/CSA
300 V
4 kV
III
2
5.5 mm
Page 298 + 308
WOS 2 15-60 VUC WOS 2 115 VUC WOS 2 230 VUCOpto-coupler WAVESERIES
with AC voltage output and
zero voltage switch
Ordering data
Screw connection
Tension clamp connection
Input
Input voltage
Input current
Making threshold
Breaking threshold
Switch-on delay
Switch-off delay
Status indicator normal operation
Output
Output current
Closed supply-circuit current (output not switched)
Voltage supply
Residual voltage
Protection circuit
Short-circuit in output
Temperature
Operating temperature**
Storage temperature
Mechanical data
Overall width
Housing material
Approvals
Reliable separation according to EN 50 178
Coordination of insulation according to EN 50 178
Opto-coupler according to VDE 0884
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearance/creepage path
Accessories, dimensions and connection data see
*at ambient temperature 20 °C/horizontal installation
Zero V. switch
Zero V. switch Zero V. switch
Opto-coupler in component housing WAVESERIES
Schematic circuit diagram
WOS 2 15-60 VUC
waagerecht montiert; Ansteuerung : 60Vac
0
0,5
1
1,5
2
2,5
3
3,5
020406080100 120
Umgebungstemperatur [°C]
A
bstand>=10mm
WOS 2 15-60 VUC • 8275440000
Output current [A]
Mounted horizontally
Control 253 Vdc
Ambient temperature [°C]
Mounted
clearance 10 mm
128
Type Cat. No.
WOS 2 24 Vuc
8237720000
WOZ 2 8430110000
18 Vuc ... 30 Vuc
2.8 mA ac at 24 V
3.7 mA dc at 24 V
ca.13 V dc ca.14 V ac
ca.10 V dc ca.13 V ac
20 ms ac 7.0 ms dc
46 ms ac 50 ms dc
LED green in output
LED red in output*
short-circuit protection
max. 500 mA per channel
max. 2 A
12 Vdc...24 Vdc...28 Vdc
typ. 0.9 A
min. 0.65 A, max. 1.2 A, RL2
0.65 V, at 500 mA
Polarity protection, varistor
100 %
max. 3 W
-25 °C...+50 °C rowed
-40 °C...+85 °C
22.5 mm
Polyamide PA 66
UL/CSA
150 V
2.5 kV
III
2
3 mm
Page 298 + 308
Type Cat. No.
WOS 2 115 Vuc
8275360000
WOZ 2 8430130000
115 Vuc, max. 130 Vuc
1.4 mA ac at 115 V
2.0 mA dc at 115 V
ca.60 V dc ca.60 V ac
ca.50 V dc ca.50 V ac
40 ms ac 15 ms dc
60 ms ac 70 ms dc
LED green in output
LED red in output*
short-circuit protection
max. 500 mA per channel
max. 2 A
12 Vdc...24 Vdc...28 Vdc
typ. 0.9 A
min. 0.65 A, max. 1.2 A, RL2
0.65 V, at 500 mA
Polarity protection, varistor
100 %
max. 3 W
-25 °C...+50 °C rowed
-40 °C...+85 °C
22.5 mm
Polyamide PA 66
UL/CSA
150 V
2.5 kV
III
2
3 mm
Page 298 + 308
Type Cat. No.
WOS 2 230 Vuc 827534
0000
WOZ 2 8430140000
230 V, max. 250 V
1.4 mA ac at 230 V
2.0 mA dc at 230 V
ca.150 V dc ca.120 V ac
ca.110 V dc ca.110 V ac
40 ms ac 14 ms dc
95 ms ac 140 ms dc
LED green in output
LED red in output*
*LED red, one LED for
all channels
short-circuit protection
max. 500 mA per channel
max. 2 A
12 Vdc...24 Vdc...28 Vdc
typ. 0.9 A
min. 0.65 A, max. 1.2 A, RL2
0.65 V, at 500 mA
Polarity protection, varistor
100 %
max. 3 W
-25 °C...+50 °C rowed
-40 °C...+85 °C
22.5 mm
Polyamide PA 66
UL/CSA
300 V
4 kV
III
2
5.5 mm
Page 298 + 308
WOS 2 24 VUC WOS 2 115 VUC WOS 2 230 VUC
Ordering data
Screw connection
Tension clamp connection
Input
Input voltage
Input current
Making threshold
Breaking threshold
Switch-on delay
Switch-off delay
Status indicator normal operation
Status indicator short-circuit, underload, overload
Output1)
Output current
Output total current
Voltage supply
Response threshold
Residual voltage
Protection circuit
Synchronisation factor
Lamp load
Temperature
Operating temperature
Storage temperature
Mechanical data
Overall width
Housing material
Approvals
Reliable separation according to EN 50 178
Coordination of insulation according to EN 50 178
Opto-coupler according to VDE 0884
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearance/creepage path
Accessories, dimensions and connection data see
1) Protection circuit for output load necessary, page 107
Opto-coupler WAVESERIES
(4-channel, short-circuit proof)
Opto-coupler in component housing WAVESERIES
Schematic circuit diagram
WOS 2 230 VUC
waagerecht montiert
Ausgangsstrom/Kanal: 500mA; Ansteuerung : 250Vac
0
0,1
0,2
0,3
0,4
0,5
0,6
0102030405060
Umgebungstemperatur [°C]
A
bstand>=10mm
WOS 2 230 VUC • 8275340000
Output current [A]
Mounted horizontally, output current / channel: 500 mA
Control 250 Vdc
Ambient temperature [°C]
Mounted
clearance
10 mm
129
Digital signal
processing
Type Cat. No.
WOS 1 5 VTTL 50 kHz
8275210000
WOZ 2 8430070000
5 VTTL
11.8 mA at 4.75 V
13.6 mA at 5 Vdc
15.5 mA at 5.25 Vdc
4.75 Vdc … 5.25 Vdc
110 K
50 kHz at Rload = 470
1 µs
7 µs
LED green in input circuit
21.6 Vdc...24 Vdc...26.4 Vdc
approx.5.4 mA, output not
switched
50 mA
1.5 V at 50 mA
Polarity protection, varistor
-25 °C...+60 °C rowed
-40 °C...+85 °C
22.5 mm
Polyamide PA 66
UL/CSA
300 V
4 kV
III
2
5.5 mm
Page 298 + 308
Type Cat. No.
WOS 1 12-28 Vdc/100 kHz
8275450000
WOZ 2 8430000000
12V dc...28 Vdc
5.5 mA at
12 Vdc
7.9 mA at
24 Vdc
8.8 mA at
28 Vdc
approx.5 V dc
approx.4 V dc
100 kHz at Rload = 470
1 µs
3 µs
LED green in input circuit
21.6 Vdc...24 Vdc...26.4 Vdc
approx.5.4 mA, output not
switched
50 mA
1.5 V at 50 mA
Polarity protection, varistor
-25 °C...+60 °C rowed
-40 °C...+85 °C
22.5 mm
Polyamide PA 66
UL/CSA
300 V
4 kV
III
2
5.5 mm
Page 298 + 308
WOS 1 5 VTTL
50 kHz WOS 1 12-28 VDC
100 kHz
Opto-coupler WAVESERIES
with high switching frequency
Ordering data
Screw connection
Tension clamp connection
Input
Input voltage
Input current
Supply voltage
Input resistance
Making threshold
Breaking threshold
Input frequency
Switch-on delay
Switch-off delay
Status indicator normal operation
Output
Voltage supply
Supply nominal current
Output current
Residual voltage
Protection circuit
Temperature
Operating temperature
Storage temperature
Mechanical data
Overall width
Housing material
Approvals
Reliable separation according to EN 50 178
Coordination of insulation according to EN 50 178
Opto-coupler according to VDE 0884
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearance/creepage path
Accessories, dimensions and connection data see
Opto-coupler in component housing WAVESERIES
Schematic circuit diagram
WOS 1 5V TTL 50 kHZ
waagerecht montiert
Ansteuerung : 5,25V; QV-Strom: 4A eng angereihte Montage
0
0,01
0,02
0,03
0,04
0,05
0,06
020406080100
Umgebungstemperatur [°C]
A
bstand>=10mm
WOS 1 5 VTTL 50 kHz • 8275210000
Output current [A]
Mounted horizontally
Control: 5.25 V; cross-connection current: 4 A mounted in rows
Ambient temperature [°C]
Mounted
clearance 10 mm
130
Schematic circuit diagram
Ordering data
Rated data
Input
Input voltage
Input current (at UN)
Rated input consumption
Max. input frequency dc
Typ. switch-on delay
Typ. switch-off delay
Max. input frequency ac
Output
Supply voltage
Max. output current
Reverse polarity protection
Short-circuit conditions
Thermal short-circuit
Load Indication LI 1, LI 2
Supply voltage
Max. current
Max. voltage drop
Storage temperature
Ambient temperature
- rowed on mounting rail without clearances
- rowed with clearances
Insulation coordination EN 50 178
Overvoltage category
Pollution severity
Accessories, dimensions and connection data see
Type Cat. No.
EGO 5 PKR 8220870000
Screw connection 0.5…4 mm2
24 Vac/dc, min 20 Vac/dc, max 30 Vac/dc
12 mA (24 Vdc)
13 mA (24 Vac)
195 mW, 220 mVA
30 Hz, switching ratio 1 : 2
2 ms
7 ms
10 Hz
Screw connection 0.5…4 mm2
20…30 Vdc
4 A
present
short-circuit-protected (switches output off immediately;
auto switch-on when short-circuit eliminated)
12 A. output switches off and on again automatically after
certain time.
5…48 Vdc
100 mA
1.6 V
–40 °C…+60 °C
–20 °C…+40 °C
–20 °C…+50 °C
IV
2
Page 307, Fig. VII
EGO 5 PKR 24 Vac/dcpower opto-couplers
With "online" check-back indication of the load ratio
• Power opto-couplers for load currents up to 4 A.
• Short-circuit proof
• Patented "online" load indication and check-back
indication
- optical indication
status indication via 3-coloured LEDs
- electrical indication
2-bit "online" data signal for check-back indication
of the load performance to a PLC or similar
• Module fulfils protective separation in accordance
with VDE 0106 Part 101 and EN 50 178
(rated voltage 300 V)
• Internal opto-coupler according to with DIN VDE
0884
• Insulation voltage 4 kVeff
• Clearance and creepage distances 8 mm
Indication and check-back indication of load ratio
Input Load Indication LI 1 LI 2 LED Output
Low x x x L L off low
High Normal L H green high
High Error1)HLred low
High Open Load2)H H yellow high
2) Open load: Underload recognition at active input: type 500 mA (max. 1.5 A) at 25 °C.
Open load wil be indicated at ILoad 500 mA depending on switching status.
1) Error: short-circuit, overload, over- or under voltage at out-
put, overtemperature in the module
Opto-coupler in component housing EG5
131
Digital signal
processing
Type Cat. No.
OST EG7 4 A 8281720000
RS EG7 8193830000
Cat. No.
Lugs for
socket RS EG7 8193830000
21.6 Vdc 24 Vdc 26.4 Vdc
10.5 mA 11.2 mA 12.0 mA
230 mW 270 mW 320 mW
21.6 V
2 V
LED green
present
typ. 10 µs
typ. 45 µs
100 Hz (resistive load/4 A/ Switching ratio 1 : 2)
21.6…26.4 Vdc
4 A
0.2 V, not short-circuit proof and not overload proof
output set
normal function
- 25…+ 60 °C
0…+ 40 °C
0…+ 50 °C
-
III
2
Page 304
Type Cat. No.
OST EG7 2 A 8269050000
RS EG7 8193830000
Cat. No.
Lugs for
socket RS EG7 8193830000
24 Vac/dc ± 20 %
dc: 5.5 mA ac: 6 mA
dc: 132 mW ac: 145 mW
19.2 V
2.4 V
LED green, yellow, red
-
12 ms
17 ms
100 Hz (resistive load/2 A/ Switching ratio 1 : 2)
24 Vdc ± 30 %
2 A
0.2 V, short-circuit proof and overload proof
output set
normal function, 500 mA...2 A
output set, no activity, < 500 mA
output set, short-circuit
output not set
- 25…+ 60 °C
0…+ 40 °C
0…+ 50 °C
according to DIN VDE 0884
III
2
Page 304
Ordering data
Puggable opto-coupler, without socket
socket for pluggable opto-coupler with combin. foot TS 32, 35
Rated data
Conductor connection
Input voltage
Input current
Input power
Relaibly switched on
Reliably switched off
Status indicator
Reverse polarity protection
Switch-on delay
Switch-off delay
Max. Switching frequency
Output supply voltage
Switching current
Voltage drop at max. load current
Status indicator:
Green LED
Yellow LED
Red LED
LED off
Storage temperature
Operating temperature
- rowed on mounting rail without clearances
- rowed with clearances
Insulation coordination to EN 50 178
Reliable separation
Overvoltage category
Pollution severity
Accessories, dimensions and connection data see
Schematic circuit diagram
power opto-couplers
– Pluggable on socket RS EG 7 with
combination foot TS 32, 35
– Overall width 10 mm
• Short circuit protected
and over load-safe
output
• 3-colour status-LED for
output current indica-
tion
• Reliable separation acc.
to DIN VDE 0884
OST EG7
2 A OST EG7
4 A
Opto-coupler in component housing EG7
OST EG 7
RS EG 7
OST EG 7
RS EG 7
132
Ordering data
Combination foot for TS 15, TS 32, TS 35
Plug-in opto-coupler, without engagement socket
Engage. socket for opto-coupler with combin. foot TS 32, 35
Rated data
Input voltage
Switch-on current
Making threshold,typical
Rated input current DC
Rated input current AC
Rated input consumption
Output supply voltage
Output current
Max. output current
Switch-on time (first time)
Switch-off time
Switching frequency
Storage temperature
Ambient temperature
Connection
Insulation coordination to EN 50 178
Protective separation
Clearances and creepage distances
Rated impulse voltage
Overvoltage category
Pollution severity
Accessories
Cross connection comb 16-pole
Further accesories, dimensions and connection data see
Schematic circuit diagram
Type Cat. No.
EGO EG7 8092490000
OST EG7 8234560000
RS EG7 8193830000
5 V– ±20 %
3 V–
6.8 mA
5…48 V–
100 mA
300 mA
6 ms for UN= 5 V–
12 ms for UN= 5 V–
15 Hzdc
–40…+60 °C
–25…+60 °C
acc. to DIN VDE 0884
5.5 mm
6 kV
III
2
Type Cat. No.
QB 16/10.16 1650330000
Page 304
Type Cat. No.
EGO EG7 8092510000
OST EG7 8234570000
RS EG7 8193830000
12 V0±20 %
12 V/4.5 mA for max. 10 ms
6.5 V–
7.5 V~
3 mA
33.5 mA
40 mW/50 mVA
5…48 V–
100 mA
300 mA
6 ms for UN= 12 V–
12 ms for UN= 12 V–
15 Hzdc
–40…+60 °C
–25…+60 °C
acc. to DIN VDE 0884
5.5 mm
6 kV
III
2
Type Cat. No.
QB 16/10.16 1650330000
Page 304
Type Best.-EGO
EGO EG7 8092530000
OST EG7 8234580000
RS EG7 8193830000
24 V0±20 %
12 V/4.5 mA for max. 10 ms
15.5 V–
16.5 V~
2.8 mA
3.4 mA
70 mW/90 mVA
5…48 V–
100 mA
300 mA
5 ms for UN= 24 V–
15 ms for UN= 24 V–
15 Hzdc
–40…+60 °C
–25…+60 °C
acc. to DIN VDE 0884
5.5 mm
6 kV
III
2
Type Cat. No.
QB 16/10.16 1650330000
Page 304
Type Cat. No.
EGO EG7 8092550000
OST EG7 8234590000
RS EG7 8193830000
48 V0±20 %
12 V/4.5 mA for max. 10 ms
31.5 V–
45 V~
2.8 mA
3.2 mA
135 mW/155 mVA
5…48 V–
100 mA
300 mA
5 ms for UN= 48 V–
15 ms for UN= 48 V–
15 Hzdc
–40…+60 °C
–25…+60 °C
acc. to DIN VDE 0884
5.5 mm
6 kV
III
2
Type Cat. No.
QB 16/10.16 1650330000
Page 304
Opto-couplers
– With combination foot for TS 15, TS 32 or TS 35
– Pluggable on socket RS EG 7 with combination foot
TS 32, 35
– Overall width 10 mm
Reliable separation according to DIN VDE 0884
5 V12 V024 V048 V0
EGO EG 7
OST EG 7
RS EG 7
OST EG 7
RS EG 7
EGO EG 7
Opto-coupler in component housing EG7
133
Digital signal
processing
Type Cat. No.
EGO EG7 8092570000
OST EG7 8234600000
RS EG7 8193830000
115 V0±20 %
115 V/90 mA for 5 ms
70 V–
72 V~
3.3 mA
5.5 mA
400 mW/500 mVA
5…48 V–
100 mA
300 mA
5 ms for UN= 115 V–
18 ms for UN= 115 V–
15 Hzdc
–40…+60 °C
–25…+60 °C
acc. to DIN VDE 0884
5.5 mm
6 kV
III
2
Type Cat. No.
QB 16/10.16 1650330000
Page 304
Type Cat. No.
EGO EG7 8092590000
OST EG7 8234610000
RS EG7 8193830000
230 V~ ±20 %
230 V/110 mA for 2 ms
140 V~
3.8 mA
836 mVA
5…48 V–
100 mA
300 mA
5 ms for UN= 230 V–
18 ms for UN= 230 V–
12 Hz
–40…+60 °C
–25…+60 °C
acc. to DIN VDE 0884
5.5 mm
6 kV
III
2
Type Cat. No.
QB 16/10.16 1650330000
Page 304
Type Cat. No.
OST EG7 8621190000
230 Vdc ±20 %
230 V~ /110 mA for 2 ms
140 V~ (for testing only)
1.8 mA
100 mA
300 mA
–40…+60 °C
–25…+60 °C
Screw connection
0.5…1.5mm2, AWG 22…16
acc. to DIN VDE 0884
5.5 mm
6 kV
III
2
Type Cat. No.
QB 16/10.16 1650330000
Page 304
Ordering data
Combination foot for
TS 15, TS 32, TS 35
Pluggable opto-coupler, without
locking socket
Locking socket for pluggable
opto-coupler with combin. foot
TS 32, 35
Rated data
Input voltage
Switch-on current
Making threshold,typ,
Rated input current DC
Rated input current AC
Rated input consumption
Output supply voltage
Output current
Max. output current
Switch-on time
(first time)
Switch-off time
Switching frequency
Storage temperature
Ambient temperature
Insulation coordination to
Reliable separation
Clearances / creepage distances
Rated impulse voltage
Overvoltage category
Pollution severity
Accessories
Cross connec. comb 16-pole
Futher Accessories, dimensions
and connection data see
Schematic circuit diagram
Opto-couplers
for long control cables
– with combination foot for
TS 15, TS 32 or TS 35
– plugs onto locking socket
RS EG 7 with combination
TS 32, 35
– overall width 10 mm
protective separation
acc. to DIN VDE 0884
– RC-input for suppressing
noise signals
– reliable switching perfor-
mance by interference on
the control side
115 V0230 V9230 Vdc 115 V0230 V9
Type Cat. No.
EGO EG7 8397420000
OST EG7 8315590000
RS EG7 8193830000
115 V0±20 %
115 V/90 mA for 5 ms
70 V–
72 V~
3.3 mA
9 mA/90 mA (5 ms)
400 mW/500 mVA
5…48 V–
100 mA
300 mA
9 ms for UN= 115 V–
25 ms for UN= 115 V–
12 Hzdc
–40…+60 °C
–25…+60 °C
EN 50 178
acc. to DIN VDE 0884
5.5 mm
6 kV
III
2
Type Cat. No.
QB 16/10.16 1650330000
Page 304
Type Cat. No.
EGO EG7 8387580000
OST EG7 8394990000
RS EG7 8193830000
230 V~ ±20 %
230 V/110 mA for 2 ms
140 V~
14 mA/110 mA (2 ms)
836 mVA
5…48 V–
100 mA
300 mA
15 ms for UN= 230 V–
15 ms for UN= 230 V–
12 Hz
–40…+60 °C
–25…+60 °C
acc. to DIN VDE 0884
5.5 mm
6 kV
III
2
Type Cat. No.
QB 16/10.16 1650330000
Page 304
EGO EG 7
OST EG 7 RC
RS EG 7 RC
EGO EG 7
EGO EG 7 RC/
OST EG 7 RC
Opto-coupler in component housing EG7
Accessories
SSR Standard
Complete module
29
5,1
12,7
25,4
Dimensions
134
Compact dimensions
(29 x 25.4 x 12.7)
Combines with PLUGSERIES socket
PXS / PXZ,
LED indicator PLED and PRC holding
clamp to a complete functioning unit.
Fully compatible with electromechanical
relays in standard design
Control voltage 24 VAC / DC
Rated switching current 24 VDC, 24
VAC/DC, or 230 VAC
Up to 5 A continuous current
Mounts onto PCB or socket
High mounting density possible
Ordering data
Technical data
Input (typical values at 20 °C)
Input voltage min. AC/DC
Input voltage max. AC/DC
Input current min. AC/DC
Input current max. AC/DC
Drop-out voltage AC/DC
Resistance
Output
max. switching current DC
max. switching current AC
min. switching current DC
min. switching current AC
Rated switching voltage DC
Rated switching voltage AC
Switch voltage range DC
Switch voltage range AC
max. forward anode voltage at max. switching current DC
max. forward anode voltage at max. switching current AC
max. switch-on time DC
max. switch-on time AC (50 Hz)
max. switch-off time DC
max. switch-off time AC (50 Hz)
Insulation
Test voltage control circuit - switching circuit DC
Test voltage control circuit - switching circuit AC
Further data
Operating temperature range
Weight
Approvals
Celduc
Further accessories, dimensions and connection data
Type Cat. No.
SSR 24 VUC/24VDC 5A
8576350000
DC Version
15 V
30 V
6.1 mA
12 mA
2.5 V
2.100
5 A
1 mA
24 V
0...30 V
0.3 V
2 ms
18 ms
2.5 kVeff
-40 °C…+50 °C
approx.18 g
cUL, UL recognized
SPD07505
see page 83
Type Cat. No.
SSR 24 VUC/230VAC 4A
8576360000
AC Version
15 V
30 V
6.1 mA
12 mA
2.5 V
2.100
3 A (4 A at 20 °C)
50 mA
230 V ~
12...275 V
1.1 V
12 ms
20 ms
4 kVeff
-40 °C…+50 °C
approx.18 g
cUL, UL recognized
SPA07420
see page 83
L1 N
21
14
A1
A2
A1
A2
21
14
DC version
AC version
* Free-wheel diode for
inductive loads
*
load
12-275 VAC
Load
Solid State relay on locking socket PLUGSERIES
DC version AC version
Type/Version
Screw connection
POS 24Vdc/24Vdc 2.5A
POS 24Vdc/230Vac 2A
POS 24Vdc/24Vuc 1A
POS 24Vdc/24Vdc 5A
POS 24Vdc/230Vac 4A
Tension clamp connection
POZ 24Vdc/24Vdc 2.5A
POZ 24Vdc/230Vac 2A
POZ 24Vdc/24Vuc 1A
POZ 24Vdc/24Vdc 5A
POZ 24Vdc/230Vac 4A
Type/Version
Screw connection
POS 24Vac/24Vdc 2.5A
POS 24Vac/24Vdc 5A
POS 24Vac/230Vac 4A
Tension clamp connection
POZ 24Vac/24Vdc 2.5A
POZ 24Vac/24Vdc 5A
POZ 24Vac/230Vac 4A
Cat. No.
8610840000
8610860000
8610890000
8610900000
8610910000
8610920000
8610930000
8610960000
8610970000
8610980000
Cat. No.
8615600000
8615620000
8615590000
8615640000
8615650000
8615630000
Digital signal
processing
135
Accessories
SSR / RT
Compact dimensions
(29 x 15.7 x 12.7)
Combines with PLUGSERIES socket
PXS / PXZ,
LED indicator PLED and PRC holding
clamp to a complete functioning unit.
Fully compatible with standard elec-
tromechanical relays RT
Control voltage 24 VAC / DC
Rated switching current 24 VDC, 24
VAC/DC, or 230 VAC
Up to 5 A continuous current
Mounts onto PCB or socket
High mounting density possible
Ordering data
Technical data
Input
(typical values at 20 °C)
Input voltage
min. AC/DC
Input voltage
max. AC/DC
Input current min. AC/DC
Input current max. AC/DC
Drop-out voltage AC/DC
Resistancs
Output
max. switching current DC
max. switching current AC
max. switching current AC/DC
min. switching current DC
min. switching current AC
min. switching current AC/DC
Rated switching voltage DC
Rated switching voltage AC
Rated switching voltage AC/DC
Switch voltage range DC
Switch voltage range AC
Switch voltage range
AC/DC
max. forward anode voltage at
max. switching current DC
max. forward anode voltage at
max. switching current AC
max. forward anode voltage at
max. switching current AC/DC
max. switch-on time DC
max. switch-on time AC (50 Hz)
max. switch-on time AC/DC (50 Hz)
max. switch-off time DC
max. switch-off time AC (50 Hz)
max. switch-off time AC/DC (50 Hz)
Insulation
Test voltage control circuit -
switching circuit DC
Test voltage control circuit -
switching circuit AC
Test voltage control circuit -
switching circuit AC/DC
Further data
Operating temperature range
Weight
Approvals
Celduc
Further accessories, dimen-
sions and connection data
Type Cat. No.
SSR 24 VUC/24VDC 2.5A
8576340000
DC Version
15 V
30 V
6.1 mA
12 mA
2.5 V
2.100
2.5 A
1mA
24 V
0...30 V
0.5 V
2 ms
18 ms
2.5 kVeff
-40 °C…+50 °C
approx.11 g
cUL, UL recognized
STD07205
see page 83
Type Cat. No.
SSR 24 VUC/24VUC 1A
8576380000
AC/DC Version
15 V
30 V
6.1 mA
12 mA
2.5 V
2.100
1A
1mA
24 V
0...30 V
0.9 V
5 ms
12 ms
4 kVeff
-40 °C…+50 °C
approx.11 g
cUL, UL recognized
STN07105
see page 83
Type Cat. No.
SSR 24 VUC/230VAC 2A
8576370000
AC Version
15 V
30 V
6.1 mA
12 mA
2.5 V
2.100
2A
50mA
230 V
12...275 V
1 V
12 ms
20 ms
4 kVeff
-40 °C…+50 °C
approx.11 g
cUL, UL recognized
STA07220
see page 83
L1 N
21
14
A1
A2
A1
A2
21
14
A1
A2
L1 N
21
14
29 12,7
15,7
5,1
DC version
AC version
AC/DC version
* Free-wheel diode
for inductive loads
*
Load
STN
Load
Load
Solid State relay on locking socket PLUGSERIES
Dimensions
12-275 VAC
max. 30 VAC/DC
5 V–2)12 V0±10 % 24 V– ± 10 % 24 V0±10 % 48 V0±10 %
115 V0, +5%-15%
230 V~, +5%-15%
0.045 W 0.25 W 0.51 W 0.34 W 0.55 W 0.33 W
0.32 VA 0.5 VA 0.65 VA 0.65 VA 0.52 VA
5…48 V–1)5…48 V–1)5…48 V–1)5…48 V–1)5…48 V–1)5…48 V–1)5…48 V–1)
< 0.9 V < 1.6 V < 0.9 V < 1.6 V < 1.6 V < 1.5 V < 1.5 V
20 mA 100 mA 20 mA 100 mA 100 mA 100 mA 100 mA
0.2 A/10 ms 0.8 A/10 ms 0.2 A/10 ms 0.8 A/10 ms 0.8 A/10 ms 0.8 A/10 ms 0.8 A/10 ms
0.16 mA 0.16 mA 0.16 mA 0.16 mA 0.16 mA 0.16 mA 0.16 mA
12 µs 6 ms 30 µs 2 ms 5 ms 10 ms 6 ms
15 µs 13 ms 60 µs 15 ms 20 ms 23 ms 18 ms
3 kHz 20 Hz 3 kHz 20 Hz < 20 Hz 10 Hz
< 10 Hz < 10 Hz
1 : 2 10 Hz 1 : 2 1 : 2 10 Hz 1 : 1 10 Hz 1 : 1 10 Hz 1 : 1 10 Hz 1 : 1
300 V 300 V 300 V 300 V 300 V 300 V 300 V
6 kV 6 kV 6 kV 6 kV 6 kV 6 kV 6 kV
IV IV IV III IV IV IV
2222222
5.5 mm 5.5 mm 5.5 mm 5.5 mm 5.5 mm 5.5 mm 5.5 mm
according to according to according to according to according to according to according to
DIN VDE 0884 DIN VDE 0884 DIN VDE 0884 DIN VDE 0884 DIN VDE 0884 DIN VDE 0884 DIN VDE 0884
according to according to according to according to according to according to according to
DIN VDE 0884 DIN VDE 0884 DIN VDE 0884 DIN VDE 0884 DIN VDE 0884 DIN VDE 0884 DIN VDE 0884
non-destructive non-destructive non-destructive non-destructive non-destructive non-destructive non-destructive
test 1 kV test 1 kV test 1 kV test 1 kV test 1 kV test 1 kV test 1 kV
acc. to IEC 801-4 acc. to IEC 801-4 acc. to IEC 801-4 acc. to IEC 801-4 acc. to IEC 801-4 acc. to IEC 801-4 acc. to IEC 801-4
severity 4 severity 4 severity 4 severity 4 severity 4 severity 4 severity 4
4 kV~eff 1 min. 4 kV~eff 1 min.
–40 °C…+85 °C –40 °C…+70 °C
–25 °C…+60 °C –25 °C…+40 °C
–25 °C…+60 °C –25 °C…+45 °C
136
Opto-coupler on locking socket profile RS 40
RS 40
Rated data
Input voltage
Rated consumption – (W)
Rated consumption ~ (VA)
Output supply voltage
Voltage drop at max. load current
Output current
Derating curve
a = rowed on mounting rail without clearances
b = rowed with clearances 20 mm
Pulse duration, limiting overload current (not periodic)
Sperrstrom (Ruhestrom), max. at U = 48 V
Switch-on time (cyclic operation)
Switch-off time (cyclic operation)
Max. switching frequency DC voltage
Max. switching frequency AC voltage
Switching ratio
Insulation coordination to EN 50 178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearances and creepage distances
Opto-coupler
Test voltage (corresponds 100% module test)
Module is immune to interference
Insulation voltage
Input – output/mounting rail
Storage temperature
Ambient temperature
–, rowed on mounting rail without clearances
–, rowed with clearances 20 mm
Continuous
current
Ambient temperature
1) Not TTL-compatible
2) Conditionally level-compatible
20 or
100
20 or 100
Opto-couplers
for signal input
137
Digital signal
processing
Ordering data
Connection method Input Function Screw Disconnect plug with
voltage indicator connection (GSE) screw connection (BL/SL)
5 V2)Yellow LED 1118861001 1161560000
12 V0Green LED 1118761001 1161660000
24 V– Yellow LED 1160961001 1161760000
11778600001)
24 V0Yellow LED 1117461001 1119460000
Green LED 8065031001
48 V0Green LED 1161061001 1161860000
115 V0Green LED 1161161001 1161960000
230 V~ Green LED 1161461001 1162060000
230 V~ Red LED 8182690000
Connection data
Insulation stripping length 7 mm 6 mm
Conductor cross-section 0.5…2.5 mm2 0.5…1.5 mm2
AWG 26…14 AWG 26…16
Dimensions
Mounting width 11.2 mm 11.2 mm
Length (perpendicular to mounting rail) 70 mm 74 mm
Height TS/TS 35 x 7.5 56 mm/51.5 mm 56 mm/51.5 mm
Opto-coupler on locking socket profile RS 40
RS 40
1) Output 5 VTTL-compatible
2) Conditionally level-compatible
138
20
/
10
19/
9
+
16
2
2
+
162
164
161
GND
max.
2A
+24V
2
2
2
+
22
24
21
GND
max.
2A
+24V
RSM 16: 1
RSM 8: 1
RSM 4: 1
+
12
14
11
GND
max.
2A
+24V
3
3
3
+
32
34
31
GND
max.
2A
+24V
4
4
4
+
42
44
41
GND
max.
2A
+24V
8
8
+
82
84
81
GND
max.
2A
+24V
5 V–1) ±10 %
60 mW
5…48 V1)
<1.6 V
0.1 A
0.8 A/10 ms
0.16 mA
100 Hz
–40 °C…+85 °C
–25 °C…+60 °C
–25 °C…+60 °C
75 mm
145 mm
285 mm
87 mm
24 V– ±10 %
400 mW
5…48 V1)
<1.6 V
0.1 A
0.8 A/10 ms
0.16 mA
100 Hz
–40 °C…+85 °C
–25 °C…+60 °C
–25 °C…+60 °C
75 mm
145 mm
285 mm
87 mm
24 V0 ±10 %
300 mW
0.35 VA
5…48 V1)
<1.6 V
0.1 A
0.8 A/10 ms
0.16 mA
20 Hz
–40 °C…+85 °C
–25 °C…+60 °C
–25 °C…+60 °C
75 mm
145 mm
285 mm
87 mm
24 V– +10 %
288 mW
24 V ±10 %
0.4 V
2 A
12 A/10 ms
12 mA
max. 100 Hz
–40 °C…+60 °C
–25 °C…+60 °C
–25 °C…+60 °C
75 mm
145 mm
285 mm
87 mm
Opto coupler on locking socket with multiple interface RSM
Rated data
Input voltage
Rated consumption – (W)
Rated consumption ~ (VA)
Output operating voltage
Voltage drop at max. load current
Output current
Derating curve
a = Continous operation
b = Switching mode
Continuous
current
Ambient temperature
Pulse duration, limiting overload current (not periodic)
Max. reverse current (static current), at U
Switching frequency
Storage temperature
Ambient temperature
–, rowed on mounting rail without clearances
–, rowed with clearances x 20 mm
Dimensions
Mounting width
RSM 4
RSM 8
RSM 16
Length (perpendicular to mounting rail)
RSM 4 OS
4 opto-couplers
RSM 8 OS
8 opto-couplers
Also available as relay coupler, see page 84/85
Schematic circuit diagram DC voltage/positive switching (joint negative)
Opto coupler 24 Vdc / 2A Standard Opto coupler 5…48 Vdc / 100 mA
1)Not TTL-compatible
(Opto-couplers)
Note!
During operation and maintenance
please observe the relevant ESD
measures.
(ESD endangered area)
Ordering data
Conn. method Input RSM 4 OS RSM 8 OS RSM 16 OS Positive Negative Cat.
Mount. width
Input/output voltage w/o. optocoupl. 4 optocoupl. w/o. optocoupl. 8 optocoupl. w/o. optocoupl. 16 optocoupl. switching3)switching4)No. (mm)
Screw/ 1123661001 75
5 V–2)1124061001 145
 1124461001 285
8017581001 75
*1123861001 75
*1123761001 75
8003671001 145
24 V– 8021391001 145
*1124261001 145
8018221001 285
8082471001 285
*1124661001 285
*1125161001 75
24 V0*1125261001 145
Connection data
Insulation stripping length 7 mm
Conductor cross-section 0.5…2.5 mm2/AWG 26…14
Replacement opto-c. Type Input voltage Output voltage Output current Cat. No.
OS 5 V–5) ±10 % 24 V– ±20 % 0.1 A 1121100000
OS 12 V–5) ±10 % 5…48 V– 0.1 A 1124800000
OS 12 V0±10 % 5…48 V– 0.1 A 1121200000
OS 24 V–5) ±10 % 5…48 V– 0.1 A 1124900000
OS 24 V–5) ±10 % 24 V– +10 % 2.0 A 1170200000
OS 24 V–5) ±10 % 250 V~ 0.1 A 1153200000
OS 24 V0±10 % 5…48 V– 0.1 A 1121300000
139
Digital signal
processing
RSM 16 OS
16 Opto couplers
DC/negative switching (common positive) DC/AC voltage
Opto coupler on locking socket with multiple interface RSM
2) 5 V TTL Input voltage on request
3) Common negative potential, positive is switched
4) Common positive potential, negative is switched
5) Not suitable for DC/AC version
*equipped as standard with opto-coupler 5…48 Vdc / 100 mA
140
1) The rating data depend on the used module
2) on request
3) Mixed placement of input and output modules is not valid.
Ordering data
Rated data (with inpu module)1)
Input voltage, max.
Input current (per channel)
Max. output voltage
Output current (per channel),
max.
Rated data (with output module)1)
Input voltage, max.:
Input current (per channel)
Max. output supply voltage
Max. output current
(per channel)
Auxilary voltage
Status indicator
Fuse
Storage temperature
Ambient temperature
Connection data
Conductor cross-section
Screw connection
Male connect. block DIN 416512)
„Sub-D“-connection2)
Dimensions
Mounting width
Length (perpendicular
(to mounting rail)
Schematic circuit diagram
Type Cat. No.
RS 1 HR 1166961001
250 V~
25 mA
24 V0
Depending on module
24 V0
Depending on module
250 V
Depending on module
24 V– ±10 %
LED red
5x20, 5 A quick
–40 °C…+70 °C
–25 °C…+70 °C
Dependent on semiconductor
relay used
0.5…2.5 mm2
35 mm
87 mm
Type Cat. No.
RSM 4 HR 11670610013)
250 V~
25 mA
24 V0
Depending on module
24 V0
Depending on module
250 V
Depending on module
24 V– ±10 %
LED red
5x20, 5 A quick
–40 °C…+70 °C
–25 °C…+70 °C
Dependent on semiconductor
relay used
0.5…2.5 mm2
130 mm
87 mm
Type Cat. No.
RSM 8 HR 11671610013)
250 V~
25 mA
24 V0
Depending on module
24 V0
Depending on module
250 V
Depending on module
24 V– ±10 %
LED red
5x20, 5 A quick
–40 °C…+70 °C
–25 °C…+70 °C
Dependent on semiconductor
relay used
0.5…2.5 mm2
10-pole
15-pole
249 mm
87 mm
Type Cat. No.
RSM 8 HR-100 11662610013)
250 V~
25 mA
24 V0
Depending on module
24 V0
Depending on module
250 V
Depending on module
24 V– ±10 %
LED red
5x20, 5 A quick
–40 °C…+70 °C
–25 °C…+70 °C
Dependent on semiconductor
relay used
0.5…2.5 mm2
10-pole
15-pole
156 mm
109 mm
Type Cat. No.
RSM 16 HR-100* 1167261001
3)
250 V~
25 mA
24 V0
Depending on module
24 V0
Depending on module
250 V
Depending on module
24 V– ±10 %
LED red
5x20, 5 A quick
–40 °C…+70 °C
–25 °C…+70 °C
Dependent on semiconductor
relay used
0.5…2.5 mm2
20-pole
25-pole
305 mm
109 mm
Single and multiple
socket interface-
unit
Advantages of
semiconductor relays:
• Wear-free switching
also with high switching
frequencies
• Bounce-free switching
• No electomagnetic
interferences
• High insulation-voltage
between load and
control circuit
Note!
The relevant ESD
measures are to be
observed during
commissioning and
maintenance
(ESD endangered area)
RS 1 HR RSM 4 HR RSM 8 HR RSM 8 HR-100 RSM 16 HR-100
Opto coupler, locking socket for semi-conductor relays
141
Digital signal
processing
1) 250 V max. in connection with HR modules.
Only negative-switching when used on HR-socket!
2) For inductive loads the module must be protected with diode
or varistor.
Schematic circuit diagram
Type Cat. No.
HRE 24 117440000
10…32 V– (process)
21.33 mA
1.5 k
18…32 V (Logic)1)
0.4 V
100 mA
max. 100 µA
5 ms
5 ms
–40 °C…+100 °C
–20 °C…+ 70 °C
Type Cat. No.
HRE 115 1174500000
90…140 V0(process)
10 mA
14 k
18…32 V (Logic)1)
0.4 V
100 mA
max. 100 µA
20 ms
20 ms
–40 °C…+100 °C
–25 °C…+ 70 °C
Type Cat. No.
HRE 230 1174600000
180 V…280 V0(process)
6.4 mA
44 k
18…32 V (Logic)1)
0.4 V
100 mA
max. 100 µA
20 ms
20 ms
–40 °C…+100 °C
–25 °C…+ 70 °C
Type Cat. No.
HRA 230 1174100000
18…32 V– (Logic)
2.2 k
3 V
1 V
24…250 V~1)2) (process)
3 A
20 mA
6 mA
75 A/20 ms
1/2 Period
1/2 Period
unlimited, tmin 100 µs
–40 °C…+100 °C
–25 °C…+ 70 °C
Type Cat. No.
HRA 60 1174300000
18…32 V– (Logic)
2.2 k
3 V
1 V
5…60 V~1)2) ( process)
3 A, resistive load
1 mA
5 A/1 s
100 µs
750 µs
unlimited, tmin 100 µs
–40 °C…+100 °C
–25 °C…+ 70 °C
Semi-conductor relays
Input module
HRE 24
DC/DC
Input module HRE 115/HRE 230
AC/DC
Output module
HRA 230
DC/AC
Output module
HRA 60
DC/DC
Ordering data
Rated data
Input voltage
Input current at max. V
Input resistance
Switch-on voltage
Switch-off voltage
Max. output
operating voltage
Voltage drop at
max. load current
Max. output current
(Continous test)
Derating curve
a = self-cooling
b = mounted on
2 k/W heat sink
Continuous current
Ambient temperature
Min. Load current
Leakage current in off-
condition at rated load voltage
Surge current
Switch-on time
Switch-off time
Input impulse
Storage temperature
Ambient temperature
Zero V. switch Amp.
Solid state relays
for signal input
and output
142
Timers
143
Digital signal
processing
Timers
The IT product family of electronic delay
timers from Weidmüller are the optimum
solution for industrial tasks.
The product family IT offers:
Response delay (ITR)
Wiping contact without control input
(ITWo)
Wiping contact with control input (ITWw)
Turn-off delay without control input
(ITTo)
Turn off delay without control input
(ITTw)
Pulse generator (ITTT)
Multifunction (ITM)
Multifunction (ITMF)
Designation of types:
I=Industry
T=Timer
R=Response Delay
Wo =Wiping contact relay without
control input
Ww=Wiping contact relay
with control input
To =Turn -off delay without control
input
Tw =Turn-off delay with control input
TT =Two Times
M=Multifunction
MF =Multifunction Four
Time ranges and supply voltages of
delay timer relays
Product
ITR
ITWo, ITTT
ITTw
ITWw
ITMF, ITM
ITTo
Time
0.1s - 100h
0.06 s - 160 s
Range
0.1 s - 1 s 1 min - 10 min
1 s - 10 s 0.1 h - 1 h
0.1 min - 1 min 1 h- 10 h
10 h - 100 h
0.06 s - 0.6 s 2 s - 20 s
0.25 s - 2.5 s 16 s - 160 s
Voltage supply
24 VDC/24…24UVAC
24 V - 240 VAC
24 VDC
The multiple voltage ranges of the supply
voltage allow for a wide area of use in
industry (see table).
The modules’ functions for 4 or 7 time can
be precisely selected via the rotary button.
Characteristic data of output contacts
Limit values by resistive load
Service life of contacts by resistive load
ITTo
ITM
ITR, ITP, ITWo, ITWw, ITTw,ITTT, ITMF
Output of the timing relays
The load in every module is switched by a
changeover relay (250 V, 8 A).
The multifunction module (ITM) switches
both changeover relays immediately or,
one changeover relay immediately and the
other changeover relay delayed.
Switching capacity (kVA)
Switching operations
Voltage
Current
Load
Load
Control contact
144
Functions of the Timers
Response delay ITR timer relay
As soon as the operating voltage is applied,
the preset delay period T begins.
After time period T has expired,
output R connects the load.
Wiping contact timer relay without control input ITWo
When the operating voltage is applied,
output R connects the load immediately.
After the preset delay period T has expired,
output R disconnects the load.
Wiping contact timer relay with control input ITWw
As soon as the operating voltage is applied,
a pulse (e. g. 50 ms) or a voltage is applied to control
input Y1. Output R connects the load immediately.
After the preset delay period T has expired,
output R disconnects the load.
Turn-off delay timer relay without control input ITTo
As soon as the operating voltage is applied,
output R connects the load. Delay period T does
not begin until the operating voltage is switched off.
After delay period T has expired, output R
disconnects the load.
Turn-off delay timer relay with control input ITTw
After the operating voltage has been applied and con-
trol input Y1 has been activated, output R connects the
load for an indefinite period of time. When the control
input is opened and after the preset time period T has
expired, the output disconnects the load.
Pulse generator ITTT
The repeat cycles starts with two individually adjustable
times after applying the supply voltage.
There is a different starting state for each delay.
Function A: Response delay
As soon as the operating voltage is
applied, the preset delay period T
begins. After time period T has expired,
output R connects the load.
Function Ac:
Response delay and turn-off delay
As soon as operating voltage has
been applied and control input Y1 has
closed, delay period T begins. After time
period T has expired, output R connects
the load (delayed response). When con-
trol input Y1 is opened, the output dis-
connects the load after the preset time
period has expired (delayed turn-off).
Function At:
Additive response delay
As soon as the operating voltage has
been applied and delay period T has
expired, output R connects the load. At
control input Y1 the contact break inter-
vals are accumulated (additive process).
As soon as the operating voltage is
switched off, the load at output R is dis-
connected.
Function B:
Wiping contact with control input
As soon as the operating voltage has
been applied, a pulse (min 50 ms) or a
voltage can be applied to control input
Y1. Output R connects the load immedi-
ately. After delay period T has expired,
output R disconnects the load.
Function Bw: Wiping function
The operating voltage must be applied.
As soon as a voltage is applied to con-
trol input Y1, output R connects the
load for the prest time T. After time peri-
od T has expired, output R disconnects
the load. As soon as the control input is
opened, output R once more connects
the load for the duration of time period
T. After time period T has expired, out-
put R disconnects the load.
Function C:
Turn-off delay with control input
As soon as the operating voltage has
been applied and control input Y1 has
been activated, output R connects the
load for an indefinite period of time.
When the control input is opened and
after the preset time period T has
expired, the output disconnects the
load.
Function D: Pulse generator
(begins in the zero position)
As soon as the operating voltage has been
applied, output R simultaneously switches the
load alternately between the zero position and
operating position for the period of the preset
time T. With this function, the cycle begins at
the zero position.
Function Di: Pulse generator
(begins in the operating position)
As soon as the operating voltage has been
applied, output R simultaneously switches the
load alternately between the zero position and
operating position for the period of the preset
time T
. With this function, the cycle
begins at the operating position.
Function H:
Wiping contact without control input
As soon as the operating voltage is
applied, output R connects the load
immediately. After delay period T has
expired, output R disconnects the load.
Function Ht:
Wiping contact, additive
As soon as the operating voltage is
applied, output R connects the load
immediately. At control input Y1 the
contact break intervals are accumulated
(additive process) and when the preset
delay period has expired, output R dis-
connects the load.
U= Operating voltage
R= Output relay or load
T= Delay
Y1 = Control input
Multifunction ITM/ITMF
145
Digital signal
processing
Timers
Dimensions IT
Status LED
Two LED’s show the status of the mod-
ules:
-green LED = supply voltage connected
-yellow LED = relay output active
(not for ITTO)
Marking
Marking is done on a removable tag or on
the marking area. The function is printed
on the front of the module.
Control lamp for verifying contact
A control lamp can be wired parallel to
input Y1 to show the status of control
input.
Assembly
Mount direct onto DIN TS 35 mounting
rails.
Approvals and standards
This relay has a high resistance to interference. The housing material is
self-extinguishing (UL94/V0).
Manufacturing to IEC/VDE and UL/CSA approvals permit worldwide usage.
IEC 255 static measuring relays
IEC529 testers and test procedures
IEC 664 regulations for high-voltage fuses for motor circuits
IEC 801 EMC compatibility
VDE 0110 insulation coordination for low-voltage electrical equipment
VDE 0435 relays with fixed times
Connection technology
Clamping yoke has the following
capacities:
•2 x 1.5 mm2with ferrule
•2 x 2.5 mm2without ferrule
•1 x 4 mm2without ferrule
on DIN rail
on panel using M4 screws
146
Ordering data
Contact
Time periods
Repeat accuracy (const. parameter)
Accuracy of indication acc. to IEC 1812-1
Input
Input voltage
Voltage tolerance
Duty factor
Rated power consumption
Min pulse duration type
Max. reset time at
voltage interruption
Protection against voltage interruption
Output
Contact
Contact material
Service life - mechanical
- electrical
Switching current - max.
- min.
Max. switching voltage
Switching current
Status indicators
Voltage applied
Relay output active
Approvals
Standards
Temperature - Storage temperature
- Operating temperature
Clearance/creepage path. acc. to IEC 664/VDE 0110
Protection category IEC 529 - Terminal block
- Front
Mounting
Installation category to IEC 664
Connection
- with ferrule
- without ferrule
Enclosure material
Weight, typ.
Schematic circuit diagram
Type Cat. No.
ITM 8362550000
changeover
0.1 s - 100 h
1 s, 10 s, 1 min
1 h, 10 h, 100 h
±0.5%
±10% (25 °C)
12 V…240 Vac/dc / 50...60 Hz
85 - 110% UN
100 %
7 VA / 230 V~
50 ms
100 ms
> 10 ms
Relay output
2 changeover
AgCdO
5x10
6switching operations
10
5
switching operations at 2000 VA resistive load
8 A0 / changeover contact
100 mA0
250 V0
2000 VA / 80 W
green LED
yellow LED
UL / CSA
IEC 529/ IEC 664/IEC 801/IEC 255
VDE 0435/VDE 0110
–30°C...+70°C
–20°C...+60°C
4 kV
IP 20
IP 50
DIN rail 35 mm
Category III
2 x 1.5 mm2
2 x 2.5 mm2/ 1 x 4 mm2
self extinguishing
110 g
Multifunctional Timers
Response delay
Response delay and
turn-off delay
Additive response delay
Wiping contact with
control input
Wiping function
Turn-off delay with
control input
Pulse generator
(begins in the zero position)
Pulse generator
(begins in the operating position)
Wiping contact without
control input
Wiping contact, additive
ITM
Multifunctional timer relay
Function A: Response delay
As soon as the operating voltage is
applied, the preset delay period T
begins. After time period T has expired,
output R connects the load.
Function Ac:
Response delay and turn-off delay
As soon as operating voltage has
been applied and control input Y1 has
closed, delay period T begins. After time
period T has expired, output R connects
the load (delayed response). When con-
trol input Y1 is opened, the output dis-
connects the load after the preset time
period has expired (delayed turn-off).
Function At:
Additive response delay
As soon as the operating voltage has
been applied and delay period T has
expired, output R connects the load. At
control input Y1 the contact break inter-
vals are accumulated (additive process).
As soon as the operating voltage is
switched off, the load at output R is dis-
connected.
Function B:
Wiping contact with control input
As soon as the operating voltage has
been applied, a pulse (min 50 ms) or a
voltage can be applied to control input
Y1. Output R connects the load immedi-
ately. After delay period T has expired,
output R disconnects the load.
Function Bw: Wiping function
The operating voltage must be applied.
As soon as a voltage is applied to con-
trol input Y1, output R connects the
load for the prest time T. After time peri-
od T has expired, output R disconnects
the load. As soon as the control input is
opened, output R once more connects
the load for the duration of time period
T. After time period T has expired, out-
put R disconnects the load.
Function C:
Turn-off delay with control input
As soon as the operating voltage has
been applied and control input Y1 has
been activated, output R connects the
load for an indefinite period of time.
When the control input is opened and
after the preset time period T has
expired, the output disconnects the
load.
Function D: Pulse generator
(begins in the zero position)
As soon as the operating voltage has been
applied, output R simultaneously switches the
load alternately between the zero position and
operating position for the period of the preset
time T. With this function, the cycle begins at
the zero position.
Function Di: Pulse generator
(begins in the operating position)
As soon as the operating voltage has been
applied, output R simultaneously switches the
load alternately between the zero position and
operating position for the period of the preset
time T
. With this function, the cycle
begins at the operating position.
Function H:
Wiping contact without control input
As soon as the operating voltage is
applied, output R connects the load
immediately. After delay period T has
expired, output R disconnects the load.
Function Ht:
Wiping contact, additive
As soon as the operating voltage is
applied, output R connects the load
immediately. At control input Y1 the
contact break intervals are accumulated
(additive process) and when the preset
delay period has expired, output R dis-
connects the load.
U= Operating voltage
R= Output relay or load
T= Delay
Y1 = Control input
147
Digital signal
processing
Schematic circuit diagram
Type Cat. No.
ITTo 8362600000
Changeover
0.6 s -160 s
(0.06 s - 0.6 s, 0,25 s - 2.5 s,
2 s - 20 s, 16 s - 160 s)
±0.5%
±10% (25 °C)
24 Vdc/ 24…240 Vac / 50...60 Hz
85 - 110% UN
100 %
0.5 W / 30 VA / 230 V~
_
50 ms
100 ms
> 10 ms
Relay output
2 changeover
AgCdO
5x10
6switching operations
105switching operations at 1250 VA resistive load
8 A0 / changeover contact
100 mA0
250 V0
1250 VA / 80 W
green LED
UL / CSA
IEC 529/ IEC 664/IEC 801/IEC 255
VDE 0435/VDE 0110
–30°C...+70°C
–20°C...+60°C
4 kV / 2
IP 20
IP 50
DIN rail 35 mm
Category III
2x1.5 mm2
2x2.5 mm2 / 1x4 mm
2
self extinguishing
100 g
Type Cat. No.
ITTw 8362610000
Changeover
0.1 s -100 h
(0.1 s - 1 s, 1 s -10 s, 0.1 min - 1 min,
1 min - 10 min, 0.1 h - 1 h, 1 h - 10h)
±0.5%
±10% (25 °C)
24 Vdc/ 24…240 Vac / 50...60 Hz
85 - 115% UN (110% for 240 V)
100 %
0.5 W / 24 V- / 1 W / 48 V- / 2 VA / 48 V~
1.5 VA / 24 V~
12 VA / 230 V~
50 ms
100 ms
> 10 ms
Relay output
1 changeover
AgCdO
5x10
6switching operations
105switching operations at 2000 VA resistive load
8 A0
100 mA0
250 V0
2000 VA / 80 W
green LED
yellow LED
UL / CSA
IEC 529/ IEC 664/IEC 801/IEC 255
VDE 0435/VDE 0110
–30°C...+70°C
–20°C...+60°C
4 kV / 2
IP 20
IP 50
DIN rail 35 mm
Category III
2x1.5 mm2
2x2.5 mm2 / 1x4 mm
2
self extinguishing
100 g
Timers
Ordering data
Contact
Time periods
Repeat accuracy (const. parameter)
Anzeigegenauigkeit gemäß IEC 1812-1
Input
Input voltage
Voltage tolerance
Duty factor
Rated power consumption
Min. switch-on time for the supply
Min pulse duration type
Max. reset time at voltage interruption
Protection against voltage interruption
Output
Contact
Contact material
Service life - mechanical
- electrical
Switching current - max.
- min.
Max. switching voltage
Switching current
Status indicators
Voltage applied
Relay output active
Approvals
Standards
Temperature - Storage temperature
- Operating temperature
Clearance/creepage path. acc. to IEC 664/VDE 0110
Protection category IEC 529
- Terminal block
- Front
Mounting
Installation category to IEC 664
Connection
- with ferrule
- without ferrule
Enclosure material
Weight, typ.
ITTo
Turn-off delay timer relay without control
input
ITTw
Turn-off delay timer relay with control
input
148
Type Cat. No.
ITWo 8362580000
Changeover
0.1 s - 100 h
(0.1 - 1 s, 1 s - 10 s, 0.1 min. - 1 min.,
1 min. - 10 min., 0.1 h - 1 h, 1 h - 10 h, 100 h)
±0.5%
±10% (25 °C)
24 Vdc/ 24…240 Vac / 50...60 Hz
85 - 115% UN (110% for 240 V)
100 %
0.5 W / 24 V-
1.5 VA / 24 V~
12 VA / 230 V~
50 ms
100 ms
> 10 ms
Relay output
1 changeover
AgCdO
5x10
6switching operations
105switching operations at 2000 VA resistive load
8 A0
100 mA0
250 V0
2000 VA / 80 W
green LED
yellow LED
UL / CSA
IEC 529/ IEC 664/IEC 801/IEC 255
VDE 0435/VDE 0110
–30°C...+70°C
–20°C...+60°C
4 kV / 2
IP 20
IP 50
DIN rail 35 mm
Category III
2x1.5 mm2
2x2.5 mm2 / 1x4 mm
2
self extinguishing
100 g
Type Cat. No.
ITWw 8362590000
Changeover
0.1 s - 100 h
(0.1 - 1 s, 1 s - 10 s, 0.1 min. - 1 min.,
1 min. - 10 min., 0.1 h - 1 h, 1 h - 10 h, 100 h)
±0.5%
±10% (25 °C)
24 Vdc/ 24…240 Vac / 50...60 Hz
85 - 115% UN (110% for 240 V)
100 %
0.5 W / 24 V- / 1 W / 48 V- / 2 VA / 48 V~
1.5 VA / 24 V~
12 VA / 230 V~
50 ms
100 ms
> 10 ms
Relay output
1 changeover
AgCdO
5x10
6switching operations
105switching operations at 2000 VA resistive load
8 A0
100 mA0
250 V0
2000 VA / 80 W
green LED
yellow LED
UL / CSA
IEC 529/ IEC 664/IEC 801/IEC 255
VDE 0435/VDE 0110
–30°C...+70°C
–20°C...+60°C
4 kV / 2
IP 20
IP 50
DIN rail 35 mm
Category III
2x1.5 mm2
2x2.5 mm2 / 1x4 mm
2
self extinguishing
100 g
Schematic circuit diagram
Timers
ITWo
Wiping contact timer relay without control
input
Ordering data
Contact
Time periods
Repeat accuracy (const. parameter)
Accuracy of indication acc. to IEC 1812-1
Input
Input voltage
Voltage tolerance
Duty factor
Rated power consumption
Min pulse duration type
Max. reset time at voltage interruption
Protection against voltage interruption
Output
Contact
Contact material
Service life - mechanical
- electrical
Switching current - max.
- min.
Max. switching voltage
Switching current
Status indicators
Voltage applied
Relay output active
Approvals
Standards
Temperature - Storage temperature
- Operating temperature
Clearance/creepage path. acc. to IEC 664/VDE 0110
Protection category IEC 529
- Terminal block
- Front
Mounting
Installation category to IEC 664
Connection
- with ferrule
- without ferrule
Enclosure material
Weight, typ.
ITWw
Wiping contact timer relay with control
input
149
Digital signal
processing
Schematic circuit diagram
Type Cat. No.
ITTT 8324050000
Changeover
0.1 s - 100 h
(0.1 - 1 s, 1 s - 10 s, 0.1 min. - 1 min.,
1 min. - 10 min., 0.1 h - 1 h, 1 h - 10 h, 100 h)
±0.5%
±10% (25 °C)
24 Vdc/ 24…240 Vac / 50...60 Hz
85 - 115% UN (110% for 240 V)
100 %
0.5 W / 24 V-
1.5 VA / 24 V~
12 VA / 230 V~
50 ms
100 ms
> 10 ms
Relay output
1 changeover
AgCdO
5x10
6switching operations
105switching operations at 2000 VA resistive load
8 A0
100 mA0
250 V0
2000 VA / 80 W
green LED
yellow LED
UL / CSA
IEC 529/ IEC 664/IEC 801/IEC 255
VDE 0435/VDE 0110
–30°C...+70°C
–20°C...+60°C
4 kV / 2
IP 20
IP 50
DIN rail 35 mm
Category III
2x1.5 mm2
2x2.5 mm2 / 1x4 mm
2
self extinguishing
100 g
Type Cat. No.
ITMF 8287770000
Changeover
0.1 s - 100 h
(0.1 - 1 s, 1 s - 10 s, 0.1 min. - 1 min.,
1 min. - 10 min., 0.1 h - 1 h, 1 h - 10 h, 100 h)
±0.5%
±10% (25 °C)
24 Vdc/ 24…240 Vac / 50...60 Hz
85 - 115% UN (110% for 240 V)
100 %
0.5 W / 24 V- / 1 W / 48 V-
1.5 VA / 24 V~ / 2 VA / 48 V~
12 VA / 230 V~
50 ms
100 ms
> 10 ms
Relay output
1 changeover
AgCdO
5x10
6switching operations
105switching operations at 2000 VA resistive load
8 A0
100 mA0
250 V0
2000 VA / 80 W
green LED
yellow LED
UL / CSA
IEC 529/ IEC 664/IEC 801/IEC 255
VDE 0435/VDE 0110
–30°C...+70°C
–20°C...+60°C
4 kV / 2
IP 20
IP 50
DIN rail 35 mm
Category III
2x1.5 mm2
2x2.5 mm2 / 1x4 mm
2
self extinguishing
100 g
Timers
ITTT
Pulse generator
ITMF
Multifunction - timer relay
Ordering data
Contact
Time periods
Repeat accuracy (const. parameter)
Accuracy of indication acc. to IEC 1812-1
Input
Input voltage
Voltage tolerance
Duty factor
Rated power consumption
Min pulse duration type
Max. reset time at voltage interruption
Protection against voltage interruption
Output
Contact
Contact material
Service life - mechanical
- electrical
Switching current - max.
- min.
Max. switching voltage
Switching current
Status indicators
Voltage applied
Relay output active
Approvals
Standards
Temperature -
Storage temperature
-
Operating temperature
Clearance/creepage path. acc. to IEC 664/VDE 0110
Protection category IEC 529
- Terminal block
- Front
Mounting
Installation category to IEC 664
Connection
- with ferrule
- without ferrule
Enclosure material
Weight, typ.
150
Schematic circuit diagram
Type Cat. No.
ITR 8362570000
Changeover
0.1 s - 100 h
(0.1 - 1 s, 1 s - 10 s, 0.1 min. - 1 min.,
1 min. - 10 min., 0.1 h - 1 h, 1 h - 10 h, 100 h)
±0.5%
±10% (25 °C)
24 Vdc/ 24…240 Vac / 50...60 Hz
85 - 115% UN (110% for 240 V)
100 %
0.5 W / 24 V-
1.5 VA / 24 V~
12 VA / 230 V~
50 ms
100 ms
> 10 ms
Relay output
1 changeover
AgCdO
5x10
6switching operations
105switching operations at 2000 VA resistive load
8 A0
100 mA0
250 V0
2000 VA / 80 W
green LED
yellow LED
UL / CSA
IEC 529/ IEC 664/IEC 801/IEC 255
VDE 0435/VDE 0110
–30°C...+70°C
–20°C...+60°C
4 kV / 2
IP 20
IP 50
DIN rail 35 mm
Category III
2x1.5 mm2
2x2.5 mm2 / 1x4 mm
2
self extinguishing
100 g
Timers
ITR
Response delay timer relay
Ordering data
Contact
Time periods
Repeat accuracy (const. parameter)
Accuracy of indication acc. to IEC 1812-1
Input
Input voltage
Voltage tolerance
Duty factor
Rated power consumption
Min pulse duration type
Max. reset time at voltage interruption
Protection against voltage interruption
Output
Contact
Contact material
Service life - mechanical
- electrical
Switching current - max.
- min.
Max. switching voltage
Switching current
Status indicators
Voltage applied
Relay output active
Approvals
Standards
Temperature - Storage temperature
- Operating temperature
Clearance/creepage path. acc. to IEC 664/VDE 0110
Protection category IEC 529
- Terminal block
- Front
Mounting
Installation category to IEC 664
Connection
- with ferrule
- without ferrule
Enclosure material
Weight, typ.
151
Digital signal
processing
Schematic circuit diagram
Type Cat. No.
DKZ 24 Vac/dc 328008130000
DKZ 24 Vac/dc 35 8008190000
24 Vac/dc ±10 %
5.1 mAdc/6.1 mAac ±10 %
130 mW ±10 %/150 mVA ±10 %
1s
0.7 ms
5…48 Vdc
20 mA
0,16 mA (at 48 V)
1 V
0.9 Hz
300 V
4 kV
III
2
4 mm
4 kVeff
-25 °C…+50 °C
-25 °C…+50 °C
-40 °C…+85 °C
6 mm
AWG 22…12
0.5…4 mm2
ja
Type Cat. No.
AP DKT4 0687560000
Page 305
Type Cat. No.
DKZA 24 Vdc 32 8008120000
DKZA 24 Vdc 35 8008180000
24 Vdc ±18 %
6.7 mA ±10 %
200 mA ±10 %
160 mW ±10 %
50 ms
2 ms
5…48 Vdc
20 mA
0,16 mA (at 48 V)
1.6 V
20 Hz
300 V
4 kV
III
2
4 mm
4 kVeff
-25 °C…+50 °C
-25 °C…+50 °C
-40 °C…+85 °C
6 mm
AWG 22…12
0.5…4 mm2
ja
Type Cat. No.
AP DKT4 0687560000
Page 305
Type Cat. No.
DKZA 24 Vdc 32 8020990000
DKZA 24 Vdc 35 8022110000
24 Vdc ±10 %
6.7 mA ±10 %
200 mA ±10 %
160 mW
150 ms
2.5 ms
5…48 Vdc
20 mA
0,16 mA (at 48 V)
1.6 V
20 Hz
300 V
4 kV
III
2
4 mm
4 kVeff
-25 °C…+50 °C
-25 °C…+50 °C
-40 °C…+85 °C
6 mm
AWG 22…12
0.5…4 mm2
ja
Type Cat. No.
AP DKT4 0687560000
Page 305
Ordering data
For TS 32 Y
For TS 35 W
Technical data
Input
Input voltage
Input nominal current
Input current (at first-time power-up)
Input power
Switch-on delay
Switch-off delay
Min. pulse duration of input voltage
Output
Max. output voltage
Max. output voltage
Reverse current, max. (closed-circuit current)
Max. voltage drop at max. load current
Max. switching frequency
Isolation coordinates acc. to DIN VDE 0160, Draft11/94
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearance and creepage distances
Voltage proof, input/output-TS
Operating temperature without clearances
with clearances
Storage temperature
Total width
Conductor
Conductor cross-section
Reverse polarity protection
Accessories
End plate
Dimensions see
Timers
DKZ 24 Vac/dc DKZA 24 Vac/dc DKZA 24 Vac/dc
Components for extending
short pulses
Provides PLC versions with
switch-on/off delay
•Fixed times
DKZ DKZA
Signal conditioning
DKZ/DKZA timer modules
152
Ordering data
For TS 32
For TS 35
With combi foot TS32/TS 35
Technical data
Input
Supply voltage
Supply current
Control voltage
Control input current
Output
Output voltage
Max. output current
Internal voltage drop
Range of switch-on delay
Isolation coordinates acc. to DIN VDE 0160, Draft11/94
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearance and creepage distances
Voltage proof, input/output-TS
Operating temperature without clearances
with clearances
Storage temperature
Total width
Conductor
Conductor cross-section
Accessories
End plate
Dimensions see
Type Cat. No.
DKZ DK5 8228680000
24 Vdc ± 20 %
ca. 12 mA
5…48 Vdc
100 mA
1.6 V
10…100 ms (adjustable)
300 V
6 kV
IV
2
5.5 mm
4 kVeff
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
6 mm
AWG 22…12
0.5…4 mm2
Type Cat. No.
AP DK5 8268870000
Page 305
Type Cat. No.
DKZ DK5 8243780000
24 Vdc ± 20 %
ca. 12 mA
5…48 Vdc
100 mA
1.6 V
100 ms…1 s (adjustable)
300 V
6 kV
IV
2
5.5 mm
4 kVeff
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
6 mm
AWG 22…12
0.5…4 mm2
Type Cat. No.
AP DK5 8268870000
Page 305
Type Cat. No.
DKZ DK5 8019650000
24 Vdc ± 20 %
ca. 12 mA
5…48 Vdc
100 mA
1.6 V
1…100 s (adjustable)
300 V
6 kV
IV
2
5.5 mm
4 kVeff
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
6 mm
AWG 22…12
0.5…4 mm2
Type Cat. No.
AP DK5 8268870000
Page 305
DKZ DK5 DKZ DK5 DKZ DK5
Pulse conditioning
DKZ/DKZA timer modules
DKZ DKZA
Timers
Schematic circuit diagram
153
Digital signal
processing
Ordering data
For TS 32
For TS 35
With combi foot TS 32/TS 35
Technical data
Input:
Supply voltage
Supply current
Control voltage
Control input curren
Min. pulse duration of input voltage
Output:
Output voltage
Max. output current
Internal voltage drop
Range of switch-off delay
Isolation coordinates acc. to DIN VDE 0160, Draft11/94
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearance and creepage distances
Voltage proof input/output-TS
Storage temperature
Operating temperature without clearances
with clearances
Total width
Conductor
Conductor cross-section
Accessories
End plate
Dimensions see
Type Cat. No.
DKZA DK5 8243770000
24 Vdc ± 20 %
ca. 11 mA
24 Vdc ± 20 %
ca. 0.5 mA
2 ms
5…48 Vdc
100 mA
1.6 V
100 ms…1s (adjustable)
300 V
4 kVeff
IV
2
5.5 mm
6 kV
-40…+85 °C
-25…+40 °C
-25…+50 °C
6 mm
AWG 22…12
0.5…4 mm2
Type Cat. No.
AP DK5 8268870000
Page 305
Type Cat. No.
DKZA DK5 8019630000
24 Vdc ± 20 %
ca. 11 mA
24 Vdc ± 20 %
ca. 0.5 mA
2 ms
5…48 Vdc
100 mA
1.6 V
1…100 s (adjustable)
300 V
4 kVeff
IV
2
5.5 mm
6 kV
-40…+85 °C
-25…+40 °C
-25…+50 °C
6 mm
AWG 22…12
0.5…4 mm2
Type Cat. No.
AP DK5 8268870000
Page 305
Signal conditioning
DKZA timer modules
Components for extending short pulses
Provides PLC versions with switch-on/off
delay
•Fixed times
DKZA DK5DKA DK5
Type Cat. No.
DKZA DK5 8228690000
24 Vdc ± 20 %
ca. 11 mA
24 Vdc ± 20 %
ca. 0.5 mA
2 ms
5…48 Vdc
100 mA
1.6 V
10…100 ms (adjustable)
300 V
6 kV
IV
2
5.5 mm
4 kVeff
-25 °C…+40 °C
-25 °C…+50 °C
-40 °C…+85 °C
6 mm
AWG 22…12
0.5…4 mm2
Type Cat. No.
AP DK5 8268870000
Page 305
DKZA DK5
Timers
Schematic circuit diagram
154
Ordering data
For TS 35
Technical data
Input
Input voltage
Min. pulse duration
Power consupmtion
Input power
Power consumption when pulse applied
Output
Output voltage
Max. output current
Max. voltage drop at max. load
Impulse loading/limiting overload current
Reverse current at 48 V (static current)
Switch-off delay
Switching frequency dc
Insulation coordination/safe disconnection to EN 50178
Rated voltage
Rated impulse voltage
Overvoltage category
Pollution severity
Clearance and creepage distances
Voltage proof, input/output mounting rail
Opto coupler
Ambient temperature
Storage temperature
Conductor
Conductor cross-section
Approvals
Total width
Schematic circuit diagram
Turn off delay module MCZ TO MCZ TO 24 Vdc turn-off delay 50 ms MCZ TO 24 Vdc turn-off delay 150 ms
Type Cat. No.
MCZ TO 24 Vdc turn-off delay 50 ms 8324590000
24 Vdc ± 10 %
2 ms
6.7 mA ± 10 %
160 mW
200 mA
5…48 Vdc
20 mA
1.6 V
200 mA
max. 0,16 mA
50 ms
20 Hz
300 V
6 kV
III
2
5.5 mm
4 kVeff / 1 min
to VDE 0884
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
1.5 mm2
CE, UL, CSA
6 mm
Type Cat. No.
MCZ TO 24 Vdc turn-off delay 150 ms 8286410000
24 Vdc ± 10 %
2.5 ms
6.7 mA ± 10 %
160 mW
200 mA
5…48 Vdc
20 mA
1.6 V
200 mA
max. 0,16 mA
150 ms
5 Hz
300 V
6 kV
III
2
5.5 mm
4 kVeff / 1 min
to VDE 0884
-25 °C…+50 °C
-40 °C…+85 °C
AWG 22…12
1.5 mm2
CE, UL, CSA
6 mm
The timer module can be used for extending
short pulses and fixed times. Provides PLC ver-
sions with switch off delay.
tv= var
Timers
155
Digital signal