SCD5900 Rev F
FEATURES
Single power supply operation (3.3V to 5.0V) or dual power supply operation (±1.65 to ±2.5V)
Radiation performance
- Total dose: >1Mrad(Si); Dose rate = 50 - 300 rads(Si)/s
- ELDRS Immune
- SEL Immune >100 MeV-cm2/mg
- Neutron Displacement Damage >1014 neutrons/cm2
Rail-to-Rail input and output range
Short Circuit Tolerant
Full military temperature range
Designed for aerospace and high reliability space applications
Packaging – Hermetic ceramic SOIC
- 16-pin, .411"L x .293"W x .090"Ht
- Weight - 0.8 grams max
Aeroflex Plainview’s Radiation Hardness Assurance Plan is DLA Certified to MIL-PRF-38534, Appendix G.
RadHard-by-Design
GENERAL DESCRIPTION
Aeroflex’s RHD5900 is a radiation hardened, single supply, quad operational amplifier in a 16-pin SOIC
package. The RHD5900 design uses specific circuit topology and layout methods to mitigate total ionizing
dose effects and single event latchup. These characteristics make the RHD5900 especially suited for the
harsh environment encountered in Deep Space missions. It is guaranteed operational from -55°C to
+125°C. Available screened in accordance with MIL-PRF-38534 Class K, the RHD5900 is ideal for
demanding military and space applications.
ORGANIZATION AND APPLICATION
The RHD5900 amplifiers are capable of rail-to-rail input and outputs. Performance characteristics listed are
for general purpose operational 5V CMOS amplifier applications. The amplifiers will drive substantial
resistive or capacitive loads and are unity gain stable under normal conditions. Resistive loads in the low
kohm range can be handled without gain derating and capacitive loads of several nF can be tolerated.
CMOS device drive has a negative temperature coefficient and the devices are therefore inherently tolerant
to momentary shorts, although on chip thermal shutdown is not provided. All inputs and outputs are diode
protected.
The devices will not latch with SEU events to above 100 MeV-cm2/mg. Total dose degradation is minimal
to above 1Mrad(Si). Displacement damage environments to neutron fluence equivalents in the mid 1014
neutrons per cm2 range are readily tolerated. There is no sensitivity to low-dose rate (ELDRS) effects. SEU
effects are application dependant.
Standard Products
February 6, 2013
www.aeroflex.com/RHDseries
RHD5900 Quad Operational Amplifier
2
SCD5900 Rev F 2/6/13 Aeroflex Plainview
16-Pin SOIC
OUT_A
-IN_A
+IN_A
VCC
+IN_B
-IN_B
OUT_B
N/C
OUT_D
-IN_D
+IN_D
VEE
+IN_C
-IN_C
OUT_C
N/C
RHD5900
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
Notes:
1. Package and lid are electrically isolated from signal pads.
2. It is recommended that N/C or no connect pins (pins 8 and 9) and lid be grounded. This eliminates or minimizes any ESD or static buildup.
OUT_B
OUT_A
OUT_C
OUT_D
3
2
5
6
12
11
14
15
16
10
7
1
+IN_A
-IN_A
+IN_B
-IN_B
+IN_C
-IN_C
+IN_D
-IN_D
A
B
C
D
4
13
VCC
VEE
FIGURE 2: PACKAGE PIN-OUT
FIGURE 1: BLOCK DIAGRAM
3
SCD5900 Rev F 2/6/13 Aeroflex Plainview
ABSOLUTE MAXIMUM RATINGS
Parameter Range Units
Case Operating Temperature Range -55 to +125 °C
Storage Temperature Range -65 to +150 °C
Junction Temperature +150 °C
Supply Voltage VCC - VEE +6.0 V
Input Voltage VCC +0.4
VEE -0.4 V
Lead Temperature (soldering, 10 seconds) 300 °C
Thermal Resistance, Junction to Case,jc 7 °C/W
ESD Rating (MIL-STD-883, Method 3015, class 2) 2,000 - 3,999 V
Power @25°C 200 mW
NOTICE: Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress rating only;
functional operation beyond the “Operation Conditions” is not recommended and extended exposure beyond the “Operation Conditions” may affect
device reliability.
RECOMMENDED OPERATING CONDITIONS
Symbol Parameter Typical Units
+VCC Power Supply Voltage 3.3 to 5.0 V
VCM Input Common Mode Range VCC to VEE V
ELECTRICAL PERFORMANCE CHARACTERISTICS
(TC = -55°C TO +125°C, +VCC = +5.0V -- UNLESS OTHERWISE SPECIFIED)
Parameter Symbol Conditions Min Typ Max Units
Quiescent Supply Current 1/ICCQ No Load 4.7 5.5 mA
Input Offset Voltage 1/VOS -3 0.80 3 mV
Input Offset Current 1/IOS -100 10 100 pA
Input Bias Current IB
TC = +25°C, -55°C 1/-100 10 100
pA
TC = +125°C -1000 100 1000
Common Mode Rejection Ratio CMRR 70 90 dB
Power Supply Rejection Ratio PSRR 70 90 dB
Output Voltage High VOH ROUT=3.6K to GND 4.9 V
Output Voltage Low VOL ROUT=3.6K to VCC 0.1 V
Short Circuit
Output Current 2/
IO(SINK)VOUT to VCC -30 -75 mA
IO(SOURCE)VOUT to VEE 45 55 mA
Slew Rate 1/SRRL = 8K, Gain = 1 2.0 3.3 V/uS
Open Loop Gain 1/AOL No Load 90 100 dB
Unity Gain Bandwidth 1/UGBWRL = 10K 46.5 MHz
Channel Separation 2/RL = 2K, f = 1.0KHz 84 dB
Input-Referred Voltage Noise 2/enF = 5 kHz 15 nV/
Phase Margin 2/mTC 25 °C, No Load 30 Deg
Notes:
1/ Specification derated to reflect Total Dose exposure to 1 Mrad(Si) @ +25°C.
2/ Not Tested. Shall be guaranteed by design, characterization, or correlation to other test parameters.
Hz
4
SCD5900 Rev F 2/6/13 Aeroflex Plainview
R1 R2
V
OUT
V
IN
Inverting Amplifier
VOUT VIN R2
R1
-------
=
-2.5V
+2.5V
V
IN
V
OUT
R2
R1
Non Inverting Amplifier
VOUT VIN 1 R2
R1
-------
+
=
-2.5V
+2.5V
APPLICATION NOTE 1: DUAL POWER SUPPLY AMPLIFIER
Inverting Amplifier
R1
R3 V
OUT
V
IN
+5V
R4
R2
+5V
V
BIAS
VOUT VIN R2
R1
-------
=
Non Inverting Amplifier
R1
R3
V
OUT
V
IN
R4 R2
+5V
+5V
V
BIAS
VOUT VIN 1 R2
R1
-------
+
=
Note: For VOUT DC @ mid range of common mode voltage range, VBIAS = 2.5/(1+R2/R1), VBIAS = +5*R4/(R3+R4)
APPLICATION NOTE 2: SINGLE POWER SUPPLY AMPLIFIER
RHD5900 QUAD OPERATIONAL AMPLIFIER APPLICATION NOTES
5
SCD5900 Rev F 2/6/13 Aeroflex Plainview
Differential Input Amplifier
R1
R3 V
OUT
V1
V2
R4
R2
VOUT V2 R4
R3 R4+
---------------------


1R2
R1
-------+




V1R2
R1
-------


=
VEE
VCC
APPLICATION NOTE 3: DIFFERENTIAL INPUT AMPLIFIER
FIGURE 3: PACKAGE OUTLINE
Note: Package and lid are electrically
isolated from signal pads.
SCD5900 Rev F 2/6/13 6
PLAINVIEW, NEW YORK
Toll Free: 800-THE-1553
Fax: 516-694-6715
SE AND MID-ATLANTIC
Tel: 321-951-4164
Fax: 321-951-4254
INTERNATIONAL
Tel: 805-778-9229
Fax: 805-778-1980
WEST COAST
Tel: 949-362-2260
Fax: 949-362-2266
NORTHEAST
Tel: 603-888-3975
Fax: 603-888-4585
CENTRAL
Tel: 719-594-8017
Fax: 719-594-8468
www.aeroflex.com info-ams@aeroflex.com
Aeroflex Microelectronic Solutions reserves the right to
change at any time without notice the specifications, design,
function, or form of its products described herein. All
parameters must be validated for each customer's application
by engineering. No liability is assumed as a result of use of
this product. No patent licenses are implied.
Our passion for performance is defined by three
attributes represented by these three icons:
solution-minded, performance-driven and customer-focused
EXPORT CONTROL: EXPORT WARNING:
This product is controlled for export under the International Traffic in
Arms Regulations (ITAR). A license from the U.S. Department of
State is required prior to the export of this product from the United
States.
Aeroflex’s military and space products are controlled for export under
the International Traffic in Arms Regulations (ITAR) and may not be
sold or proposed or offered for sale to certain countries. (See ITAR
126.1 for complete information.)
ORDERING INFORMATION
Model DLA SMD # Screening Package
RHD5900-7 -Commercial Flow, +25°C testing only
16-pin
SOIC Package
RHD5900-S -
Military Temperature, -55°C to +125°C
Screened in accordance with the individual Test Methods
of MIL-STD-883 for Space Applications
RHD5900-201-1S 5962-1024101KXC DLA SMD Pending
RHD5900-201-2S 5962-1024101KXA
RHD5900-901-1S 5962H1024101KXC DLA SMD and Radiation Certification Pending
RHD5900-901-2S 5962H1024101KXA