Fluke 114, 115, 116 and 117
Digital Multimeters
Extended specications
Technical Data
General specications (all models)
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity of 0 % to 90 %.
Maximum voltage between any
terminal and earth ground
600 V
Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
W Fuse for A input 11 A, 1000 V FAST 17 kA Fuse (Fluke PN 803293)
Display Digital: 6,000 counts, updates 4/sec; Bar Graph: 33 segments, updates 32/sec
Temperature Operating: -10 °C to +50 °C; Storage: -40 °C to +60 °C
Humidity 0 % to 90 % to 35 °C; 75 % to 40 °C; 45 % to 50 °C
Temperature coefficient 0.1 x (specified accuracy/°C) (< 18 °C or > 28 °C)
Operating altitude 2,000 meters
Battery 9 Volt Alkaline, NEDA 1604A/IEC 6LR61
Battery life Alkaline: 400 hours typical, without backlight
Safety compliances ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA C22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN
61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1
Certifications UL, CSA, TUV, N10140 , VDE
IP rating (dust and water protection) IP42
N10140
Accuracy specications (all models)
Function Range Resolution
Accuracy ± ([% of Reading]
+ [Counts]) Model
DC millivolts 600.0 mV 0.1 mV 0.5 % + 2 114, 115, 116, 117
DC volts 6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V 0.5 % + 2 114, 115, 116, 117
DC, 45 Hz to
500 Hz 500 Hz to 1 kHz
Auto-V LoZ1 true-rms 600.0 V 0.1 V 2.0 % + 3 4.0 % + 3 114, 116, 117
45 Hz to 500 Hz 500 Hz to 1 kHz
AC millivolts1 true-rms 600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3 114, 115, 116, 117
AC volts1 true-rms 6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V 1.0 % + 3 2.0 % + 3 114, 115, 116, 117
Continuity 600 W1 WBeeper on < 20 W, off > 250 W;
detects opens or shorts of
500 µs or longer
114, 115, 116, 117
Ohms 600.0 W
6.000 kW
60.00 kW
600.0 kW
6.000 MW
40.00 MW
0.1 W
0.001 kW
0.01 kW
0.1 kW
0.001 MW
0.01 MW
0.9 % + 2
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
1.5 % + 2
114, 115, 116, 117
Diode test 2.000 V 0.001 V 0.9 % + 2 115, 116, 117
Capacitance 1000 nF
10.00 µF
100.0 µF
9999 µF
1 nF
0.01 µF
0.1 µF
1 µF
1.9 % + 2
1.9 % + 2
1.9 % + 2
100 µF to 1000 µF: 1.9 % + 2
> 1000 µF: 5 % + 20
115, 116, 117
LoZ capacitance (power-up option) 1 nF to 500 µF 10 % + 2 typical 115, 116, 117
1 All ac ranges except Auto-V LoZ are specified from 1 % to 100 % of range. Auto-V LoZ is specified from 0.0 V. Because inputs below 1 % of
range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from
a circuit or are shorted together. For volts, crest factor of 3 at 4000 counts, decreasing linearly to 1.5 at full scale. For amps, crest factor of 3.
AC volts is ac-coupled. Auto-V LoZ, ac mV, and ac amps are dc-coupled.
1.888.610.7664 info@Fluke-Direct.com Fluke-Direct.com
2 Fluke Corporation Fluke 11X Series Digital Multimeters Extended Specifications
Function Range Resolution
Accuracy ± ([% of Reading]
+ [Counts]) Model
Temperature (K-Type thermocouple) -40 °C to 400 °C
-40 °F to 752 °F 0.1 °C
0.2 °F 1 % + 102
1 % + 182116
AC amps true-rms1 (45 Hz to 500 Hz) 6.000 A
10.00 A
20 A overload for
30 seconds maximum
0.001 A
0.01 A 1.5 % + 3 115, 117
AC µAmps true-rms1 (45 Hz to 1 kHz) 600.0 µA 0.1 µA 1.5 % + 3 (2.5 % + 3 > 500 Hz) 116
DC amps 6.000 A
10.00 A
20 A overload for
30 seconds maximum
0.001 A
0.01 A 1.0 % + 3 115, 117
DC µAmps true-rms 600.0 µA 0.1 µA 1.0 % + 2 116
Hz (V or A input)299.99 Hz
999.9 Hz
9.999 kHz
50.00 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 % + 2 115, 117
Hz (V input)399.99 Hz
999.9 Hz
9.999 kHz
50.00 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 % + 2 116
1 All ac ranges except Auto-V LoZ are specified from 1 % to 100 % of range. Auto-V LoZ is specified from 0.0 V. Because inputs below 1 % of range
are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit
or are shorted together. For volts, crest factor of 3 at 4000 counts, decreasing linearly to 1.5 at full scale. For amps, crest factor of 3. AC volts is
ac-coupled. Auto-V LoZ, ac mV, and ac amps are dc-coupled.
2 AC Volts Hz is ac-coupled and specified from 5 Hz to 50 kHz. AC Amps Hz is dc-coupled and specified from 45 Hz to 5 kHz. Amps input burden
voltage (typical): 6 A input 2 mV/A, 10 A input 37 mV/A.
3 Frequency is ac-coupled, 45 Hz to 50 kHz.
Accuracy specications (all models) cont.
Frequency counter sensitivity (models 115, 116, 117)
Typical sensitivity (rms sine wave)
Input range 5 Hz to 45 Hz 45 Hz to 5 kHz 5 kHz to 10 kHz 10 kHz to 50 kHz
Volts AC 6 V
60 V
600 V
0.2 V
2 V
20 V
0.2 V to 0.3 V
2 V to 3 V
20 V to 30 V
0.3 V to 0.4 V
3 V to 4 V
30 V to 40 V
0.4 V to 1.0 V
4 V to 10 V
40 V to 100 V
AC Amps
(115, 117 only) 6 A
10 A N/A
N/A 0.4 A
0.5 A N/A
N/A N/A
N/A
Input characteristics (all models)
Function
Input impedance
(nominal) Common mode rejection ratio(1 kW unbalanced) Normal mode rejection
Volts AC > 5 MW < 100 pF > 60 dB at dc, 50 or 60 Hz
Volts DC > 10 MW < 100 pF > 100 dB at dc, 50 or 60 Hz > 60 dB at 50 or 60 Hz
Auto-V LoZ ~3 kW < 500 pF > 60 dB at dc, 50 or 60 Hz
Open circuit test voltage Full scale voltage Short circuit current
Ohms < 2.7 V dc To 6.0 MW40 MW
< 350 µA
< 0.7 V dc < 0.9 V dc
Diode Test < 2.7 V dc 2.000 V dc < 1.2 mA
Fluke. Keeping your world
up and running.
1.888.610.7664 info@Fluke-Direct.com Fluke-Direct.com