PHOENIX CONTACT Deutschland GmbH Page 1 / 4
http://www.phoenixcontact.de Feb 8, 2011
Extract from the online
catalog
SPC 5/ 8-STCL-7,62
Order No.: 1718546
The figure shows a 5-pos. version of the product
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1718546
Plug component, Nominal current: 41 A, Rated voltage (III/2): 1000 V,
Number of positions: 8, Pitch: 7.62 mm, Color: green, Metal surface:
Sn
Commercial data
GTIN (EAN)
4 046356 175210
Note Made-to-order
sales group E522
Pack 50 pcs.
Customs tariff 85366990
Catalog page information Page 385 (CC-2009)
Product notes
WEEE/RoHS-compliant since:
11/23/2006
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
Dimensions / positions
Pitch 7.62 mm
Dimension a 53.34 mm
Number of positions 8
SPC 5/ 8-STCL-7,62 Order No.: 1718546
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1718546
PHOENIX CONTACT Deutschland GmbH Page 2 / 4
http://www.phoenixcontact.de Feb 8, 2011
Technical data
Range of articles SPC 5/..-STCL
Insulating material group I
Rated surge voltage (III/3) 8 kV
Rated surge voltage (III/2) 8 kV
Rated surge voltage (II/2) 6 kV
Rated voltage (III/2) 1000 V
Rated voltage (II/2) 1000 V
Connection in acc. with standard EN-VDE
Nominal current IN41 A
Nominal voltage UN1000 V
Nominal cross section 10 mm²
Maximum load current 41 A
Insulating material PA
Inflammability class acc. to UL 94 V0
Stripping length 15 mm
Nominal voltage, UL/CUL Use Group B 600 V
Nominal current, UL/CUL Use Group B 35 A
Nominal voltage, UL/CUL Use Group C 600 V
Nominal current, UL/CUL Use Group C 35 A
Connection data
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 10 mm²
Conductor cross section stranded min. 0.2 mm²
Conductor cross section stranded max. 6 mm²
Conductor cross section stranded, with ferrule
without plastic sleeve min.
0.25 mm²
Conductor cross section stranded, with ferrule
without plastic sleeve max.
6 mm²
Conductor cross section stranded, with ferrule
with plastic sleeve min.
0.25 mm²
Conductor cross section stranded, with ferrule
with plastic sleeve max.
4 mm²
Conductor cross section AWG/kcmil min. 24
Conductor cross section AWG/kcmil max 8
2 conductors with same cross section, stranded,
TWIN ferrules with plastic sleeve, min.
0.25 mm²
SPC 5/ 8-STCL-7,62 Order No.: 1718546
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1718546
PHOENIX CONTACT Deutschland GmbH Page 3 / 4
http://www.phoenixcontact.de Feb 8, 2011
2 conductors with same cross section, stranded,
TWIN ferrules with plastic sleeve, max.
1.5 mm²
Minimum AWG according to UL/CUL 24
Maximum AWG according to UL/CUL 8
Certificates / Approvals
Certification CUL, UL
Diagrams/Drawings
Diagram
Derating curve for: SPC 5/...-ST-7.62 with
PC 5/...-G-7.62
Derating curve for: SPC 5/...-ST-7.62 with
PC 5/...-G-7.62
Conductor cross-section: 6 mm2
Dimensioned drawing
SPC 5/ 8-STCL-7,62 Order No.: 1718546
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1718546