EPP-150 150W Single Output with PFC Function series Features : 4"x2" Compact size Universal AC input / Full range Built-in active PFC function High efficiency up to 93% Protections: Short circuit / Overload / Over voltage/ Over temperature 100W free air convection, 150W with 20CFM forced air LED indicator for power on No load power consumption<0.5W Built-in 12V/0.3A auxiliary output 3 years warranty Bauar t gepruft Sicherheit egel ma ge od o s be wac g www. tuv.com ID 2000000000 SPECIFICATION UL62368-1 MODEL EPP-150-24 EPP-150-27 EPP-150-48 12V 15V 24V 27V 48V RATED CURRENT (convection) 8.4A 6.7A 4.2A 3.71A 2.1A RATED CURRENT (20CFM FAN) 12.5A 10A 6.25A 5.56A 3.125A CURRENT RANGE (convection) 0 ~ 8.4A 0 ~ 6.7A 0 ~ 4.2A 0 ~ 3.71A 0 ~ 2.1A CURRENT RANGE (20CFM FAN) 0 ~ 12.5A 0 ~ 10A 0 ~ 6.25A 0 ~ 5.56A 0 ~ 3.125A RATED POWER (convection) 100.8W 100.5W 100.8W 100.17W 100.8W RATED POWER (20CFM FAN) 150W 150W 150.12W 150W RIPPLE & NOISE (max.) Note.2 130mVp-p 150W 150mVp-p 240mVp-p 240mVp-p 300mVp-p VOLTAGE ADJ. RANGE 14.7 ~ 15.75V 2.0% 23.52 ~ 25.2V 1.0% 26.46 ~ 28.35V 1.0% 47.04 ~ 50.4V 1.0% 11.76 ~ 12.6V VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 1000ms, 30ms/230VAC 92% 92% HOLD UP TIME (Typ.) VOLTAGE RANGE INPUT TPTC004 IEC62368-1 EPP-150-15 DC VOLTAGE OUTPUT EN62368-1 EPP-150-12 16ms/230VAC Note.4 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 91.5% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.8A/115VAC LEAKAGE CURRENT OVER LOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE 2000ms, 30ms/115VAC at full load 16ms/115VAC at full load 127 ~ 370VDC PF>0.98/115VAC at full load 92% 93% 1 A/230VAC COLD START 70A/230VAC <2mA/240VAC 105 ~ 145% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 13.2 ~ 15.6V 16.83 ~ 19.5V 27.7 ~ 31.5V 30.2 ~ 34.05V Protection type : Shut down o/p voltage, re-power on to recover 51.3 ~ 62.7V Protection type : Shut down o/p voltage, re-power on to recover FUNCTION AUXILIARY POWER(AUX) WORKING TEMP. -30 ~ +70 (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY ENVIRONMENT TEMP. COEFFICIENT -40 ~ +85, 10 ~ 95% RH OPERATING ALTITUDE Note.5 2000 meters VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 6) EMC EMISSION EMC IMMUNITY OTHERS UL62368-1, TUV EN62368-1, EAC TP TC 004 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 500VDC / 25/ 70% RH Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 Compliance to EN61000-4-2,3,4,5,6,8,11, heavy industry level, criteria A, EAC TP TC 020 MTBF 207.1Khrs min. DIMENSION 101.6*50.8*29mm (L*W*H) 0.2Kg; 72pcs/15.4Kg/0.82CUFT PACKING NOTE 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes MIL-HDBK-217F (25) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the derating curve for more details. 5. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:EPP-150-SPEC 2020-10-20 EPP-150 150W Single Output with PFC Function Mechanical Specification Unit:mm 101.6 3.175 3.175 95.25 1 2 3 4 CN2 50.8 SVR1 CN105 Ground required 44.45 series CN1 3 2 1 LED FS1 T4A/250V 20CFM 4 - 3.3 50mm Air flow direction FAN 36 3 max. 29 1 2 DC Output Connector (CN2) : JST B4P-VH or equivalent AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 Assignment AC/L No Pin AC/N Mating Housing Pin No. 1,2 3,4 Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Assignment DC COM +V Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent FAN Connector(CN105) : JST B2B-PH-K-S or equivalent : Grounding required Pin No. 1 2 Assignment +12V DC COM Mating Housing Terminal JST PHR-2 or equivalent JST SPH-002T-P0.5S or equivalent Block Diagram PFC fosc : 47KHz PWM fosc : 65KHz EMI FILTER & RECTIFIER I/P PFC CIRCUIT RECTIFIERS & FILTER POWER SWITCHING +V -V RECTIFIERS & FILTER FG +12V AUX DETECTION CIRCUIT O.T.P. O.L.P. CONTROL O.V.P. Output Derating Output Derating VS Input Voltage 100 150 With 20CFM Fan 90 Convection 80 100 70 LOAD (%) LOAD (W) 75 50 25 -30 0 10 20 30 40 50 AMBIENT TEMPERATURE () 60 70 (HORIZONTAL) 60 50 40 90 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:EPP-150-SPEC 2020-10-20