SPECIFICATION
MODEL EPP-150-12 EPP-150-15 EPP-150-24 EPP-150-48EPP-150-27
DC VOLTAGE
RATED CURRENT (convection)
RATED CURRENT (20CFM FAN)
CURRENT RANGE (20CFM FAN)
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
AUXILIARY POWER(AUX)
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
12V 15V 24V 48V27V
8.4A
12.5A
6.7A
10A
4.2A
6.25A
2.1A3.71A
3.125A5.56A
0 ~ 8.4A
0 ~ 12.5A
0 ~ 6.7A
0 ~ 10A
0 ~ 4.2A
0 ~ 6.25A
0 ~ 2.1A0 ~ 3.71A
0 ~ 3.125A0 ~ 5.56A
100.8W
150W
100.5W
150W
100.8W
150W
100.8W100.17W
150W150.12W
130mVp-p 150mVp-p 240mVp-p 300mVp-p240mVp-p
11.76 ~ 12.6V 14.7 ~ 15.75V 23.52 ~ 25.2V 47.04 ~ 50.4V26.46 ~ 28.35V
±2.0%
±0.5%
±1.0%
±2.0%
±0.5%
±1.0%
±1.0%
±0.5%
±1.0%
±1.0%±1.0%
±0.5%±0.5%
±1.0%±1.0%
1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load
16ms/230VAC 16ms/115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.95/230VAC PF>0.98/115VAC at full load
13.2 ~ 15.6V 16.83 ~ 19.5V 27.7 ~ 31.5V 51.3 ~ 62.7V30.2 ~ 34.05V
91.5% 92% 93% 92%92%
1.8A/115VAC 1 A/230VAC
COLD START 70A/230VAC
105 ~ 145% rated output power
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
207.1Khrs min. MIL-HDBK-217F (25 )
File Name:EPP-150-SPEC 2020-10-20
101.6*50.8*29mm (L*W*H)
150W Single Output with PFC Function EPP-150 series
WITHSTAND VOLTAGE
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 500VDC / 25 / 70% RH
ENVIRONMENT
SAFETY &
FUNCTION
EMC
(Note 6)
PROTECTION
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by
mounting the unit on a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets 360 360
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
Product Liability Disclaimer For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
Features :
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
UL62368-1, TUV EN62368-1 approved
,EAC TP TC 004
Compliance to EN61000-4-2,3,4,5,6,8,11, heavy industry level, criteria A, EAC TP TC 020
4"x2" Compact size
Universal AC input / Full range
Built-in active PFC function
High efficiency up to 93%
Protections: Short circuit / Overload / Over voltage/ Over temperature
100W free air convection, 150W with 20CFM f airorced
LED indicator for power on
No load power consumption<0.5W
Built-in 12V/0.3A auxiliary output
3 years warranty
<2mA/240VAC
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
0.2Kg; 72pcs/15.4Kg/0.82CUFT
EMC IMMUNITY
EMC EMISSION
RATED POWER (convection)
CURRENT RANGE (convection)
RATED POWER (20CFM FAN)
OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover
OPERATING ALTITUDE Note.5 2000 meters
Bauar
Sicherheit
egel gema
tgepruft
od
be
www.
ID 2000000000
tuv.com
wac g
os
TPTC004
UL62368-1 EN62368-1 IEC62368-1
Mechanical Specification Unit:mm
Block Diagram
CIRCUIT
DETECTION
O.L.P.O.T.P.
EMI FILTER
RECTIFIER
&PFC
CIRCUIT
POWER
SWITCHING FILTER
&
RECTIFIERS +V
-V
I/P
FG
CONTROL
O.V.P.
Output Derating VS Input Voltage
INPUT VOLTAGE (VAC) 60Hz
90 10095 120115 160140 200180 240220 264
LOAD (%)
90
100
80
70
60
50
40
Output Derating
AMBIENT TEMPERATURE ( )
LOAD (W)
-30 0 2010 30 40
25
50
100
75
150
6050 70
PFC fosc : 47KHz
PWM fosc : 65KHz
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No.
1
2
3
Assignment
AC/L
No Pin
AC/N
Mating Housing
JST VHR JST SVH-21T-P1.1
or equivalent or equivalent
Terminal
(HORIZONTAL)
With 20CFM Fan
Convection
DC Output Connector (CN2) : JST B4P-VH or equivalent
Pin No.
1,2
3,4
Assignment
+V
DC COM
Mating Housing
JST VHR
or equivalent
Terminal
JST SVH-21T-P1.1
or equivalent
Mating Housing
JST PHR-2
or equivalent
Terminal
JST SPH-002T-P0.5S
or equivalent
FAN Connector(CN105) : or equivalentJST B2B-PH-K-S
Pin No.
1
2
Assignment
+12V
DC COM
: Grounding required
FAN
20CFM
direction
Air flow
50mm
29
3 max.
50.8
44.45 3.175
4- 3.3ψ
T4A/250V
CN1
FS1
1
2
3
4
CN2
1
2
3
3.175 95.25
101.6
LED
SVR1
CN105
1
2
FILTER
&
RECTIFIERS
+12V
AUX
150W Single Output with PFC Function EPP-150 series
Ground required
File Name:EPP-150-SPEC 2020-10-20
36