946 Series
Ultrasonic Sensors
Teachable 30 mm
Diameter, Precision Digital
Outputs
DESCRIPTION
The 946 Series provides a compromise between easy usage
and advanced features. Adjustment is easily done by auto-
tuning. By inserting a plug with four positions one can program
the sensor in a matter of seconds; the parameters are stored in
a non-volatile memory (EEPROM).
FEATURES AND BENEFITS
Scan ranges from 0,3 m to 6,0 m [0.93 ft to 19.68 ft]
Auto-tuning by four positions plug
Independent/Windows® output choice (switching output
models)
Stainless steel M30 housing, IP65
Two switching outputs, open collector PNP
Temperature compensation
M12 four-pin connector
Connector cable 2,0 m [78.75 in] included
Two independent setpoints
Teach-in programming
NO/NC window characteristic possible
Voltage or current output
POTENTIAL APPLICATIONS
Industrial:
Loop control, product height measurement
Tank liquid level measurement
Reel diameter measurement
Tire manufacturing
946 Series
2 www.honeywell.com/sensing
Table 1: Order Guide and Specifications for Connectorized Versions
Characteristic
946A4V-2D-001-65E
946-A4V-2D-001-175E
Sensor package style
30 mm [1.18 in] dia. stainless steel
Sensing distance1
max.
mIn.
6000 mm [236 in]
350 mm [13.8 in]
1000 mm [39.4 in]
200 mm [7.87 in]
Termination2
connector
Digital output
pnp
Beam angle
Supply voltage
10 Vdc to 30 Vdc
Supply current
<25 mA without load
Circuit protection
reverse polarity
Load current
0 mA to 200 mA
Hysteresis
3.2%
Switching frequency
1 Hz
5 Hz
Repeatability
<0.1% of reading
Setpoint adjustment
programmable with probe coded plug
Circuit protection
short circuit
Operating temperature
-25 °C to 70 °C [-13 °F to 150 °F]
Storage temperature
-40 °C to 85°C [-40 °F to 185 °F]
Sealing
IP65
LED indicator
red: illuminates when object is not recognized, probe coded plug withdrawn or short circuited
yellow: illuminates when indicating output function or output status
green: illuminates when target is recognized during ‘‘teach mode’’ or normal operation
Notes:
1. Standard target is 120 mm thick square of mild steel perpendicular to ultrasonic beam.
2. Includes 2 m cable with straight connector.
Figure 1. Wiring Diagram
Table 2. Accessories for Connectorized Versions
Catalog Listing
Description
804000A09M0201
2 m cable with straight
connector (used for wiring
to connector)
804001A09M020
2 m cable with right angle
connector (used for wiring
to connector)
Note:
1. Supplied with sensor.
Teachable 30 mm Diameter, Precision Digital Outputs
Honeywell Sensing and Control 3
Table 3: Order Guide and Specifications for Cable Versions
946-A4V-2D-2C0-65E
946-A4V-2D-2C0-85E
946-A4V-2D-2C0-175E
946-A4V-2D-2C0-380E
Package style
30 mm [1.18 in] dia. stainless steel
Sensing distance1
max.
mIn.
6000 mm [236 in]
350 mm [13.8 in]
4000 mm [157.5 in]
500 mm [19.7 in]
2000 mm [78.74 in]
200 mm [7.87 in]
500 mm [19.7 in]
60 mm [2.36 in]
Termination2
cable
Digital output
analog; 4 mA to 20 mA, 0 Vdc to 10 Vdc
Beam angle
Supply voltage
10 Vdc to 30 Vdc
Supply current
<33 mA without load
Circuit protection
reverse polarity
Switching frequency
2 Hz
3.3 Hz
10 Hz
28.6 Hz
Repeatability
<0.1% of reading
Linearity
<0.1%
Setpoint adjustment
programmable with probe coded plug
Load resistance:
minimum
maximum
1000 Ohm (10 Vdc to 10 Vdc output)
500 Ohm (4 mA to 20 mA output)
Slope of output
positive or negative; programmable with probe coded plug
Circuit protection
short circuit
Operating temp.
-25 °C to 75 °C [-13 °F to 167 °F]
Storage temp.
-40 °C to 85°C [-40 °F to 185 °F]
Sealing
IP 65
LED indicator
red: illuminates when object is not recognized, probe coded plug withdrawn or short circuited
yellow: illuminates when indicating output function or output status
green: illuminates when target is recognized during ‘‘teach mode’’ or normal operation
Notes:
1. Standard target is 120 mm thick square of mild steel perpendicular to ultrasonic beam.
2. Includes 2 meter cable with straight connector.
Figure 2. Wiring Diagram
Table 4: Accessories for Cable Versions
Catalog Listing
Description
804000A09M0201
2 m cable with straight connector
(used for wiring to connector)
804001A09M020
2 m cable with right angle
connector (used for wiring to
connector)
Note:
1. Supplied with sensor.
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com/sensing
000740-1-EN
February 2012
Copyright © 2012. Honeywell International Inc. All rights reserved.
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific +65 6355-2828
+65 6445-3033 Fax
Europe +44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America +1-305-805-8188
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847