EB100 High Accuracy Miniature Pressure Transducer
EB100 www.meas-spec.com April 2015
2/4
PERFORMANCE SPECIFICATIONS
Ambient Temperature: 25°C (unless otherwise specified)
Accuracy (RSS of linearity, hysteresis, and repeatability)
Long Term Stability (1 year)
Total Error Band (over compensated range)
Pressure Cycles (Zero to Full Scale)
Media compatible with 17-4PH, 316 S.S. and FKM
Fluoroelastomer
For custom configurations, consult factory.
Notes
1. Best fit straight line for all pressure ranges except for 200 bar (3 kpsi) = +/-0.35% and 350 bar (5 kpsi) = +/-0.5%.
2. TEB includes all accuracy errors, thermal errors, span and zero tolerances.
3. Per MIL-STD-810C, Procedure 514.2, Figure 514.2-2, Curve L.
4. 1/2 sine per MIL-STD 202F Method 213B condition A.
5. 21 grams per meter of cable to be added
CE Compliance
IEC 55022 Emissions Class A & B
IEC 61000-4-2 Electrostatic Discharge Immunity (2kV contact/2kV air)
IEC 61000-4-3 EM Field Immunity (3V/m)
IEC 61000-4-4 Electrical Fast Transient Immunity (0.5kV)
IEC 61000-4-6 Conducted Immunity (3V)
SUPPLY VOLTAGE / OUTPUT SIGNAL AND ELECTRICAL CONNECTION OPTIONS
8 to 30 V (current < 5 mA)
ELECTRICAL CONNECTION OPTIONS (table 1)
1 metre of shielded cable (PFA)
5 metres of shielded cable (PFA)
10 metres of shielded cable (PFA)
1 metre of shielded cable (PFA) fully covered by shrink
tube model Raychem DR25 or equivalent