Technical Datasheet Catalogue Page 1SNK 161 002 D0201 1SNK 161 002 S0201 ZS4-PE Screw Clamp Terminal Block 4 mm Ground 12 AWG Features and Benefits 5.2 mm 0.205 in Spacing Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail contact: 59.5 2.26" 56.3 2.22" 48.8 1.92" - Rail contact non operator dependent, - Performances above the requirements of IEC 60947-7-2 terminal block standard, - Secured snap on or remove from the rail. 26.7 1.05" 3D CAD outline drawings available on "Control Product 3D" portal Ordering Details Type Order Code EAN Code Pack(ing) Weight g (1 pce) Green-Yellow ZS4-PE 1SNK 505 150 R0000 3472595051502 20 12.10 Declarations and Certificates Document Part Number CE UE Directive 1SND 225 094 C1003 CB Third Party Certificate 1SND 161 024 A0201 RoHS 1SND 230 491 F0203 Atex Declaration 1SND 225 085 C1003 RoHS 1 General Information The following information must be strictly adhered to in order to guarantee the terminal block electrical, mechanical and environmental performance. Protection IP 20 Rail DIN3-TH35 Wire stripping length 10.5 mm NEMA 1 0.413 in Screw clamp Screw rail contact (Maximum value) Flat screwdriver Operating tool 3.5 mm Torque 0.138 in 0.6 Nm 5.31 lb.in 0.1 Nm 0.885 lb.in 0.1 Nm 0.885 lb.in Mechanical endurance of disconnect system Material Specifications Polyamide 600 V UL94 V0 NF F 16 101 I2F2 Needle flame test IEC 60695-11-5 Compliant Insulating material IRC Flammability Connecting capacity per clamp 0.2-4 mm 0.22-4 mm 0.22-4 mm 1 Rigid conductor 1 Flexible conductor without ferrule 1 Flexible conductor with ferrule 4.7 mm Ferrule maximum outer diameter 24-10 AWG 24-12 AWG 24-12 AWG 0.185 in Multi Connecting capacity per clamp 2 Rigid conductors 2 Flexible conductors without ferrule 2 Flexible conductors with twin ferrule Don't mix solid and flexible conductors in the same clamp Don't mix solid or flexible conductors of different sizes in the same clamp The "Connecting capacity with ferrule " data is guaranteed with ABB crimping tool PS-3 Cross section Rated cross section Maximum Cross section Gauge Manufacturer data 4 mm 4 mm Manufacturer data 12 AWG 10 AWG A3-B3 / 3 mm / 0.118 in / IEC 60947-7-1 Electrical characteristics Current Rated current Field and factory wiring Cat.2 Factory wiring Cat.1 Rated short-time withstand current 1 s (Icw) Short-time withstand current 0.5 s 5s 10 s 30 s 1 mn Rated short circuit withstand Max. current (45 temperature increase) / Max. cross section (mm) Maximum short circuit current (1s) 2 IEC 60947-7-1 UL 1059 UL 1059 CSA-C-22.2 n 158 480 A Manufacturer data Manufacturer data Manufacturer data Manufacturer data Manufacturer data CSA-C-22.2 n 158 Manufacturer data Manufacturer data 480 A 4 mm Short Circuit Current Rating (SCCR) SA UL 1059 supplement SCCR UL 1059 With the following configurations: Maximum voltage Suitable conductor wire range Fuse rating Fuse designation Fuse manufacturer name Fuse type Short circuit current Voltage Rated voltage Rated voltage Use Group Rated voltage Rated voltage Ex e IEC 60947-1 UL 1059 UL 1059 C CSA-C-22.2 n 158 IEC/EN 60079-11 8000 V 2200 V IEC 60947-1 3 IEC 60947-1 III Rated impulse withstand voltage Dielectric test voltage Pollution degree Overvoltage category Dissipated power IEC Maximum dissipated power at rated current Rated power dissipation at an ambient temperature of 23 C - IEC 60947-7-3 Overload and short-circuit protection Separate arrangement Exclusive short-circuit protection Separate arrangement 1 fuse and 4 feed-through blocks Overload and short-circuit protection Compound arrangement Exclusive short-circuit protection Compound arrangement 5 fuse blocks Temperature range Ambient temperature min/max Storage Installing Service -55 +110 C -5 +40 C IEC 60068-2-1 -55 +110 C EN 60079-7 -55 +85 C -67 +230 F -23 +104 F -67 +230 F Current Derating curve for continuous service temperature 3 Environmental Characteristics Additional climatic tests Dry heat Conditions Cyclic damp heat Conditions Cold Conditions Z/ABDM climatic sequence Conditions IEC 60068-2-2 Temperature Duration of test IEC 60068-2-30 Temperature Number of cycles IEC 60068-2-1 Temperature Duration of test IEC 60068-2-61 Dry heat Duration of test / Temperature Cyclic damp heat Number of cycles / Temperature Cold Duration of test / Temperature Compliant +100 C 96 h Compliant +55 C 2 Compliant -40 C 96 h Compliant 16 h +85 C 1 +55 C 2h -25 C Corrosion Salt mist Conditions SO2 Conditions Sulfur dioxide Conditions Hydrogen sulfur Conditions Flowing mixed gas corrosion test Conditions IEC 60068-2-11 Duration of test Concentration ISO 6988 Duration of test Concentration IEC 60068-2-42 Duration of test IEC 60068-2-43 Duration of test IEC 60068-2-60 Number of the test method Duration of test Compliant 96 h 5% Compliant 48 h 0.2 dm IEC 60068-2-6 Frequency range Number of cycles Amplitude Acceleration IEC 60068-2-64 Duration of test Frequency range Acceleration Compliant 10-55 Hz 10 Vibrations Vibrations Conditions Ramdom vibrations and climatic sequence Conditions Climatic cycles Step 1 -> Temperature / Duration of test Step 2 -> Temperature / Duration of test Temperature variation per minute 4 10 m/s ZS4-PE Terminal Block Accessories Compatibility Description Type Order Code Pack(ing) pieces g (1 pce) PDF 1 End Stops BAM3 1SNK 900 001 R0000 50 13.80 1SNK 160 026 D0201 2 End Sections ES4 1SNK 505 910 R0000 20 2.18 1SNK 160 022 D0201 3 Circuit Separators CS 1SNK 900 101 R0000 20 0.20 1SNK 160 018 D0201 CS-R1 1SNK 900 103 R0000 20 5.20 1SNK 160 018 D0201 TP2 1SNK 900 203 R0000 20 1.73 1SNK 160 036 D0201 TP4 1SNK 900 205 R0000 20 2.42 1SNK 160 036 D0201 TC5 1SNK 900 200 R0000 10 5.23 1SNK 160 042 D0201 TC5-R1 1SNK 900 201 R0000 10 5.23 1SNK 160 042 D0201 4 5 Test Adapters Test Connectors Weight Technical Datasheet 6 Protecting Covers CO 1SNK 900 604 R0000 1 300.00 1SNK 160 020 D0201 7 Protecting Cover Kits KCO 1SNK 900 624 R0000 1 47,8 1SNK 160 028 D0201 8 Tools PS-3 1SNK 900 650 R0000 1 380.00 1SNK 160 024 D0201 9 Terminal Block Markers MC512 1SNK 140 000 R0000 22 0.06 1SNK 160 003 D0201 PROCAP5 1SNK 900 609 R0000 20 0.70 1SNK 160 013 D0201 UMH 1SNK 900 611 R0000 10 0.20 1SNK 160 001 D0201 SAT5 1SNK 900 614 R0000 5 6.00 1SNK 160 013 D0201 5