12-22
Molded
Case
Circuit Breakers
10-225
Amperes
F-Frame
Cutler-Hammer
January
2001
Vol.
1,Ref.
No.
[0488]
Table
12-35.
Type
FD
Thermal-Magnetic
Circuit
Breakers
with
Non-interchangeable
Trip Units
Max.
Cont.
Ampere
Rating
@40°C
10®
15
20
25
30
35
40
45
50
60
70
80
90
100
110
125
150
175
200
225
600V
AC
Maximum,
250V
DC
14
kAIC
<g>
600V
AC
Type
FOB
(Includes
Terminals
on
Load
End
Only)
2-Pole
Catalog
Number
FDB2010
FDB2015
FOB2020
FDB2025
FDB2030
FDB2035
FDB2040
FDB2045
FDB2050
FDB2060
FDB2070
FDB2080
FDB2090
FDB2100
FDB2110
FDB2125
FDB2150
Price
U.S.
$
435.
435.
435.
435.
435.
435.
435.
393.
435.
435.
565.
565.
565.
565.
1,260.
1,260.
1,260.
3-Pole
Catalog
Number
FDB3010
FDB3015
FDB3020
FDB3025
FDB3030
FDB3035
FDB3040
FDB3045
FDB3050
FDB3060
FDB3070
FDB3080
FDB3090
FDB3100
FDB3110
FDB3125
FDB3150
Price
U.S.
$
570.
570.
570.
570.
570.
570.
570.
570.
570.
570.
695.
695.
695.
695.
1,565.
1,565.
1,565.
4-Pole
Catalog
Number
FDB4010
FDB4015
FDB4020
FOB4025
FDB4030
FDB4035
FDB4040
FDB4045
FDB4050
FDB4060
FDB4070
FDB4080
FDB4090
FDB4100
FDB4110
FDB4125
FDB4150
Price
U.S.
S
910.
910.
910.
910.
910.
910.
910.
910.
910.
1,110.
1,110.
1,110.
1,110.
1,110.
2,495.
2,495.
2,495.
277V
AC
Maximum,
125V
DC
25
kAIC
@
277V
AC
600V
AC
Maximum,
250V
DC
25
kAIC
@
480V
AC
Type
FD
(Includes
Terminals
on
Load
End
Only)
1-Pole
Catalog
Number
FD1010
FD1015S
FD1020*
FD1025
FD1030
FD1035
FD1040
FD1045
FD1050
FD1060
FD1070
FD1080
FD1090
FD1100
FD1110
FD1125
FD1150
Price
U.S.
S
299.
299.
299.
299.
299.
299.
299.
299.
299.
299.
335.
335.
335.
335.
760.
760.
760.
2-Pole
Catalog
Number
FD2015
F02020
FD2025
FD2030
FD2035
FD2040
FD2045
FD2050
FD2060
FD2070
FD2080
FD2090
FD2100
FD2110
FD2125
FD2150
FD2175
FD2200
FD2225
Price
U.S.
S
735.
735.
735.
735.
735.
735.
735.
735.
735.
855.
855.
855.
855.
1,915.
1,915.
1,915.
1,920.
1,920.
1,920.
3-Pole
Catalog
Number
FD3015
FD3020
FD3025
FD3030
FD3035
FD3040
FD3045
FD3050
FD3060
FD3070
FD3080
FD3090
FD3100
FD3110
FD3125
FD3150
FD3175
FD3200
FD3225
Price
U.S.S
865.
865.
865.
865.
865.
865.
865.
865.
865.
975.
975.
975.
975.
2,205.
2,205.
2,205.
2,205.
2,205.
2,205.
4-Pole
Catalog
Number
FD4015
FD4020
FD4025
FD4030
FD4035
FD4040
FD4045
FD4050
FD4060
FD4070
FD4080
FD4090
FD4100
FD4110
FD4125
FD4150
FD4175
FD4200
FD4225
Price
U.S.S
1,360.
1,360.
1,360.
1,360.
1,360.
1,360.
1,360.
1,360.
1,360.
1,495.
1,495.
1,495.
1,495.
3,080.
3,080.
3,080.
3,080.
3,080.
3,080.
CO
Not UL
listed.
5
kAIC
interrupting rating.
<&
UL
listed
for SWD
applications,
see NEC
Article
240-83 (d).
Note:
Instruction
Leaflet/FRED
Number
29C101
Table
12-36.
Types
HFD and FDC
Thermal-Magnetic Circuit Breakers with
Non-interchangeable
Trip Units
Max.
Cont.
Ampere
Rating
@40°C
15
20
25
30
35
40
45
50
60
70
80
90
100
110
125
150
175
200
225
277V
AC
Maximum,
125V
DC
65
kAIC
@
277V
AC
600V
AC
Maximum,
250V
DC
65
kAIC
@
480V
AC
Type
HFD
(Includes
Terminals
on
Load
End
Only)
1-Pole
Catalog
Number
HFD1015
A1
HFD1020®
HFD1025
HFD1030
HFD1035
HFD1040
HFD1045
HFD1050
HFD1060
HFD1070
HFD1080
HFD1090
HFD1100
HFD1110
HFD1125
HFD1150
Price
U.S.S
366.
366.
366.
366.
366.
366.
366.
366.
366.
427.
427.
428.
427.
1,001.
1,001.
1,005.
2-Pole
Catalog
Number
HFD2015
HFD2020
HFD2025
HFD2030
HFD2035
HFD2040
HFD2045
HFD2050
HFD2060
HFD2070
HFD2080
HFD2090
HFD2100
HFD2110
HFD2125
HFD2150
HFD2175
HFD2200
HFD2225
Price
U.S.S
885.
885.
885.
885.
885.
885.
885.
885.
885.
1,130.
1,130.
1,130.
1,130.
2,510.
2,510.
2,510.
2,720.
2,720.
2,720.
3-Pole
Catalog
Number
HFD3015
HFD3020
HFD3025
HFD3030
HFD3035
HFD3040
HFD3045
HFD3050
HFD3060
HFD3070
HFD3080
HFD3090
HFD3100
HFD3110
HFD3125
HFD3150
HFD3175
HFD3200
HFD3225
Price
U.S/S
1,140.
1,140.
1,140.
1,140.
1,140.
1,140.
1,140.
1,140.
1,140.
1,140.
1,140.
1,140.
1,140.
3,120.
3,120.
3,120.
3,120.
3,120.
3,120.
4-Pole
Catalog
Number
HFD4015
HFD4020
HFD4025
HFD4030
HFD4035
HFD4040
HFD4045
HFD4050
HFD4060
HFD4070
HFD4080
HFD4090
HFD4100
HFD4110
HFD4125
HFD4150
HFD4175
HFD4200
HFD4225
Price
U.S.
S
1,940.
1,940.
1,940.
1,940.
1,940.
1,940.
1,940.
1,940.
1,940.
2,445.
2,445.
2,445.
2,445.
4,405.
4,405.
4,405.
4,370.
4,370.
4,370.
600V
AC
Maximum,
250V
DC
100
kAIC
@
480V
AC
Type
FDC
Current
Limiting
(Includes
Terminals
on
Load
End
Only)
2-Pole
Catalog
Number
FDC2015
FDC2020
FDC2025
FDC2030
FDC2035
FDC2040
FDC2045
FDC2050
FDC2060
FDC2070
FDC2080
FDC2090
FDC2100
FDC2110
FDC2125
FDC2150
FDC2175
FDC2200
FDC2225
Price
U.S.S
1,325.
1,325.
1,325.
1,325.
1,325.
1,325.
1,325.
1,325.
1,325.
1,690.
1,690.
1,690.
1,690.
3,780.
3,780.
3,780.
3,780.
3,780.
3,780.
3-Pole
Catalog
Number
FDC3015
FDC3020
FDC3025
FDC3030
FDC3035
FDC3040
FDC3045
FDC3050
FDC3060
FDC3070
FDC3080
FDC3090
FDC3100
FDC3110
FDC3125
FDC3150
FDC3175
FDC3200
FDC3225
Price
U.S.S
1,710.
1,710.
1,710.
1,710.
1,710.
1,710.
1,710.
1,710.
1,710.
2,095.
2,095.
2,095.
2,095.
4,685.
4,685.
4,685.
4,685.
4,685.
4,685.
4-Pole
Catalog
Number
FDC4015
FDC4020
FDC4025
FDC4030
FDC4035
FDC4040
FDC4045
FDC4050
FDC4060
FDC4070
FDC4080
FDC4090
FDC4100
FDC4110
FDC4125
FDC4150
FDC4175
FDC4200
FDC4225
Price
U.S.S
2,910.
2,910.
2,910.
2,910.
2,910.
2,910.
2,910.
2,910.
2,910.
3,600.
3,600.
3,600.
3,600.
6,610.
6,610.
6,610.
6,610.
6,610.
6,610.
® UL
listed
for SWD
applications,
see NEC
Article
240-83(d).
Note: Instruction
Leaflet/FRED
Number
29C101
Discount
Symbol.
CB-2
E:T*M
For
more
information contact Cutler-Hammer
at:
www.ch.cutler-hammer.com/catalog
CAT.200.01.T.E
12
-
2
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E
January 2001
12
Product Line Overview
Vol. 1, Ref. No. [0468]
Product Line Description
Cutler-Hammer Molded Case Circuit
Breakers are designed to provide circuit
protection for low voltage distribution
systems. They are described by NEMA
as, “. . . a device for closing and inter-
rupting a circuit between separable
contacts under both normal and
abnormal conditions,” and furthermore
as, “. . . a breaker assembled as an
integral unit in a supporting and
enclosing housing of insulating
material.” The NEC describes them as,
“A device designed to open and close
a circuit by non-automatic means, and
to open the circuit automatically on a
predetermined overload of current,
without injury to itself when properly
applied within its rating.”
So designed, Cutler-Hammer circuit
breakers protect conductors against
overloads and conductors and con-
nected apparatus, such as motors and
motor starters, against short circuits.
In low voltage distribution systems,
there are many varied applications
of molded case circuit breakers.
Cutler-Hammer offers the most
comprehensive family of molded
case circuit breakers in the industry.
This family of circuit breakers includes:
Thermal Magnetic Trip Breakers
Electronic rms Trip Breakers
Molded Case Switches
Motor Circuit Protectors
Current Limiting Breakers
Special Application Breakers
World Breakers
Special Calibration
Special non-UL-listed calibrations
are available for certain ambient
temperatures other than 40°C and for
frequencies other than 50/60 Hz or DC.
Reduced interrupting ratings will apply
for 400 Hz applications. Maximum
thermal calibration is limited to 135A
at 400 Hz.
50°C Calibration
Add suffix V to Catalog Number for
complete breaker, listed above, when
ordering listed ampere ratings for
breakers to be used in 50°C ambients.
Moisture-Fungus Treatment
All circuit breaker cases are molded
from glass-polyester which does not
support the growth of fungus. Any
parts which are susceptible to the
growth of fungus will require special
treatment.
Freeze-Tested Circuit Breakers
The circuit breakers may be ordered
with freeze testing. This option uses
special lubrication and mechanical
operation is verified at -40°C.
Marine Applications
F-Frame circuit breakers can be sup-
plied to meet the following marine
specifications:
U.S. Coast Guard CFR 46 ABS —
American Bureau of Shipping
IEEE 45
These specifications generally require
molded case circuit breakers to be
supplied with 50°C ambient calibration,
special nameplating, and plug-in
adapter kits. When plug-in adapter kits
are used, no terminals need be supplied.
Circuit breakers can also be supplied
to meet UL489 Supplement SA
(Marine Use) and UL489 Supplement
SB (Naval Use).
UL489 Supplement SA applies to vessels
over 65 feet in length. Requirements
include 40°C ambient calibration, spe-
cial labeling, and no use of aluminum
conductors or terminals.
UL 489 Supplement SB requires 50°C
ambient calibration, vibration testings,
special nameplating and no use of
aluminum conductors or terminals.
Standards and Certifications
Molded case circuit breakers are
designed to conform with the follow-
ing standards:
Underwriters Laboratories, Inc.,
Standard UL489, Molded Case
Circuit Breakers and Circuit Breaker
Enclosures
National Electrical Manufacturers
Association Standards Publication
No. AB1-1993, Molded Case Circuit
Breakers
Australian Standard AS 2184,
Molded Case Circuit Breakers
British Standards Institution Standard
BS 4752: Part 1, Switchgear and
Control Gear Part 1: Circuit Breakers
Canadian Standards Association
Standard C22.2 No. 5, Service
Entrance and Branch Circuit Breakers
International Electrotechnical
Commission Recommendations
IEC 157-1, Circuit Breakers
Japanese T-Mark Standard Molded
Case Circuit Breakers
South African Bureau of Standards,
Standard SABS 156, Standard
Specification for Molded Case Circuit
Breakers
Swiss Electro-Technical Association
Standard SEV 157-1, Safety Regula-
tions for Circuit Breakers
Union Technique de l’Electricite
Standard NF C 63-120, Low Voltage
Switchgear and Control Gear Circuit
Breaker Requirements
Verband Deutscher Elektrotechniker
(Association of German Electrical
Engineers) Standard VDE 0660, Low
Voltage Switchgear and Control
Gear, Circuit Breakers
Conformance with these standards
satisfies most local and international
codes, assuming user acceptability
and simplified application.
Molded case circuit breakers equal or
exceed Federal Specification Classifi-
cation W-C-375b requirements for the
particular class associated with the cir-
cuit breaker frame being considered.
Note: For further information, see Circuit
Breaker, CD-ROM SA.74A.01.T.E.
Suffix H01 400 Hz 20% Adder
Suffix J01 Fungus Treated $325. + 20% Adder
Suffix F01 Freeze Tested 20% Adder
Suffix H08 “Marine” 10% Adder
Suffix H09 “Naval” 10% Adder
CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
12
January 2001 Product Line Overview
Vol. 1, Ref. No. [0469]
Quick Reference
Table 12-1. Industrial Circuit Breakers
N.I.T. is non-interchangeable trip unit and I.T. is interchangeable trip unit.
Two-pole circuit breaker, or two poles of three-pole circuit breaker at 250V DC.
Not defined in W-C-375b.
Circuit
Breaker
Type
Cont.
Amp.
Rating
@ 40°C
No.
Poles
Volts Type
of
Trip
Federal
Spec.
W-C-
375b
UL Listed Interrupting Ratings rms Symmetrical Amperes Page
Number
AC DC AC Ratings Volts DC
120 120/240 240 277 480 600 125 250 125/250
G-Frame
GB
GB
15 – 100
15 – 100
1
2, 3
120
240
125
125/250
N.I.T. 11a
10b, 11b,
12b, 14b,
15b
65,000
65,000
14,000
14,000
12-9
12-9
GHB
GHB
GHB
GHB
HGHB
GQ
15 – 100
15 – 100
15 – 100
15 – 100
15 – 30
15 – 20
1
2, 3
1
2, 3
1
1
120
240
277
277/480
277
277
125
125/250
125
125/250
125
N.I.T. 11a
10b, 11b,
12b, 14b,
15b
12c, 13a,
13b
65,000
65,000
65,000
65,000
14,000
14,000
25,000
14,000
14,000
14,000
14,000
14,000
14,000
14,000
12-9
12-9
12-9
12-9
12-9
12-9
GHBS
GBHS
15 – 30
15 – 20
1, 2
1, 2
277/480
347/600
N.I.T.
65,000
65,000
14,000
10,000
11-14
11-14
GC
GC
15 – 100
15 – 100
1
2, 3
120
240
125
125/250
N.I.T. 11a
10b, 11b,
12b, 14b,
15b
65,000
65,000
14,000
14,000
12-11
12-11
GD
GD
15 – 50
15 – 100
2
3
480
480
125/250
250
N.I.T.
N.I.T.
13b
13b
65,000
65,000
14,000
22,000
10,000
10,000
12-8
12-8
GHC
GHC
GHC
GHC
HGHC
15 – 100
15 – 100
15 – 100
15 – 100
15 – 30
1
2, 3
1
2, 3
1
120
240
277
277/480
277
125
125/250
125
125/250
125
N.I.T. 12c, 13a
13b
12c, 13a
13b
65,000
65,000
65,000
14,000
14,000
25,000
14,000
14,000
14,000
14,000
14,000
14,000
12-11
12-11
12-11
12-11
12-11
New E125 Frame
E125B 15 – 125 1
2, 3, 4
277
480
250 N.I.T.
35,000
25,000
25,000
18,000
18,000
10,000
10,000
12-16
E125E 15 – 125 2, 3, 4 600Y/347 250 N.I.T. 35,000 25,000 18,000 10,000 10,000 12-16
E125S 15 – 125 1
2, 3, 4
347
600Y/347
250 N.I.T.
N.I.T.
100,000
85,000
85,000
35,000
35,000
22,000
35,000
35,000
12-16
E125H 15 – 125 1
2, 3, 4
347
600Y/347
250 N.I.T.
200,000
100,000
100,000
65,000
65,000
25,000
42,000
42,000
12-17
F-Frame
ED
EDH
EDC
100 – 225
100 – 225
100 – 225
2, 3
2, 3
2, 3
240
240
240
125
125
125
N.I.T. 12b
14b
1
65,000
100,000
200,000
10,000
10,000
10,000
12-21
12-21
12-21
EHD
EHD
15 – 100
15 – 100
1
2, 3
277
480
125
250
N.I.T. 13a
13b
18,000
14,000
14,000
10,000
10,000
12-21
12-21
FDB
FDB
15 – 150
15 – 150
2, 3
4
600
600
250
250
N.I.T. 18a
18,000
18,000
14,000
14,000
14,000
14,000
10,000
10,000
12-22
12-22
FD
FD
FD
15 – 225
15 – 225
15 – 225
1
2, 3
4
277
600
600
125
250
250
N.I.T. 13a
22a
65,000
65,000
25,000
25,000
25,000
18,000
18,000
10,000
10,000
10,000
12-22
12-22
12-22
HFD
HFD
HFD
15 – 225
15 – 225
15 – 225
1
2,3
4
277
600
600
125
250
250
N.I.T. 13a
22a
100,000
100,000
65,000
65,000
65,000
25,000
25,000
10,000
22,000
22,000
12-22
12-22
12-22
FDC
FDC
15 – 225
15 – 225
2, 3
4
600
600
250
250
N.I.T. 24a
200,000
200,000
100,000
100,000
35,000
35,000
22,000
22,000
12-22
12-22
New J250 Frame
J250E
J250S
J250H
63 – 250
63 – 250
63 – 250
2, 3, 4
2, 3, 4
2, 3, 4
600
600
600
250
250
250
I.T
I.T
I.T
65,000
85,000
100,000
25,000
35,000
65,000
18,000
18,000
25,000
10,000
22,000
22,000
12-28
12-28
12-28
Cutler-Hammer
January
2001
Vol.
1,
Ref.
No.
[0485]
Molded
Case Circuit Breakers
10-225
Amperes
F-Frame
12-19
Contents
Description
Product
Description
Technical
Data
and
Specifications
Dimension/Weights
Product
Selection
..
F-Frame
Page
12-19
12-19
12-20
12-20
Product
Description
All
F-Frame Circuit Breakers
are
HACR
rated.
All
circuit
breakers
10
through
50
amperes
are
suitable
for HID
(high
intensity
discharge) use.
All
F-Frame
circuit
breakers
are
suitable
for
reverse
feed
use.
Typical
F-Frame Breaker
Technical Data
and
Specifications
Table
12-28.
UL489 Interrupting Capacity Ratings
Circuit
Breaker
Type
ED
EDH
EDC
EHD
FOB
FD
HFD
FDC
Number
of
Poles
2,3
2,3
2,3
1
2,3
2,3,4
1
2,3,4
1
2,3,4
2,3,4
Interrupting Capacity (Symmetrical Amperes) (kA)
Volts
AC
(50/60
Hz)
240
65
100
200
18
18
65
100
200
277
14
25
65
480
14
14
25
65
100
600
_
14
18
25
35
Volts
DC &
125
10
10
10
10
10
10
250 @®
10
10
10
22
22
© DC
ratings apply
to
substantially non-inductive
circuits.
®
2-pole circuit breaker,
or two
poles
of
3-pole circuit breaker.
®
Time
constant
is 3
milliseconds
minimum
at 10 kA and 8
milliseconds
minimum
at 22 kA.
Table
12-29.
IEC
157-1
(PI)
Interrupting Capacity Ratings
(P1)
Circuit
Breaker
Type
ED
EDH
EDC
FOB
FD
HFD
FDC
Number
of
Poles
2,3
2,3
2,3
2,3,4
1
2,3,4
1
2,3,4
2,3,4
Interrupting
Capacity
(Symmetrical
Amperes) (kA)
Volts
AC
(50/60
Hz)
220,
240
65
100
200
18
25
65
65
100
200
380,415
14
35
65
100
440
14
35
65
100
500
14
18
25
35
Volts
DC A
125
10
10
10
10
10
250
@®
10
10
22
22
® DC
ratings apply
to
substantially non-inductive circuits.
®
2-pole
circuit
breaker,
or two
poles
of
3-pole
circuit
breaker.
©
Time constant
is 3
milliseconds
minimum
at 10 kA and 8
milliseconds
minimum
at 22 kA.
CAT.200.01.T.E
For
more
information contact
Cutler-Hammer
at:
www.ch.cutler-hammer.com/catalog
F.T.N
12-20Molded
Case
Circuit Breakers
10-225 Amperes
F-Frame
..
f-i
-i
Cutler-Hammer
January
2001
Vol.
1,
Ref.
No.
[0486J
Dimensions/Weights
Table
12-30.
Dimensions
in
Inches (mm)
Number
of
Poles
1
2
3
4
Width
1.375(35)
2.75 (70)
4.125(105)
5.5(140)
Height
6(152)
6(152)
6(152)
6(152)
Depth
3.375
(86)
3.375
(86)
3.375
(86)
3.375
(86)
Table
12-31.
Approximate Shipping Weight, Lbs. (Kg)
Breaker Type
ED,
EDH,
EDC
EHD,
FOB,
FD,
HFD,
FDC
Number
of
Poles
1
2
(.907)
2
3
3(1.361)
3(1.361)
4.5(2.041)
4.5(2.041)
4
6(2.721)
Product
Selection
This information
is
presented only
as an aid to
understanding Catalog Numbers.
It is not to be
used
to
build
Catalog Numbers
for
circuit
breakers
or
trip units.
Table
12-32.
Circuit Breaker Catalog Numbering System
FDC 3 100 L
Circuit
Breaker
Type
EHD
FOB
FD
HFD
FDC
Number
of
Poles
1
= 1
Pole
2 = 2
Poles
3 = 3
Poles
4 = 4
Poles
Trip
Ar
010
015
020
025
030
035
J
045
050
060
070
080
090
100
110
125
150
175
(FD,
200
(FD,
225
(FD,
HFD,
FDC,
2-, 3-,
4-Pole
Only)
HFD,
FDC,
2-, 3-,
4-Pole Only)
HFD,
FDC,
2-, 3-,
4-Pole Only)
Circuit
Breaker
Type
ED
EDH
EDC
Number
of
Poles
2 =
2-Pole
3 =
3-Pole
200
Suffix
E =
100%
Protected
(4-Pole
only) Neutral
Pole
EH
= 50%
Protected
(4-Pole
only)
K
=
High Magnetic Molded
Case
Switch
L =
Line
and
Load
Terminals
S =
Stainless
Steel Terminals
V
=
50°C Calibration
W
=
Without Terminals
Y
=
Line Terminals Only
Z
=
Aluminum
Terminals
(< 100
Amperes)
Suffix
L =
Line
and
Load Terminals
W
=
Without Terminals
Y
=
Line
Terminals
Only
Z
=
Aluminum Terminals
(100
Amperes)
X
E:T*M
For
more
information contact
Cutler-Hammer
at:
www.ch.cutler-hammer.com/catalog
CAT.200.01.T.E
Cutler-Hammer
January
2001
Vol.
1,
Ref.
No.
I0489]
Molded
Case
Circuit
Breakers
10-225
Amperes
F-Frame
12-23
Molded
Case
Switches
Molded
Case
Switches
are
used
as
compact
switches
in
applications
requiring
high
current
switching
capabilities.
Molded
case
switches
are
constructed
of
circuit
breaker
components
and are of the
high
instantaneous
automatic type. Molded
case
switches
are
listed
in
accordance
with Underwriters Laboratories, Inc.,
Standard
UL
1087.
Line
and
Load
Terminals
Line
and
Load Terminals
provide
wire
connecting capabilities
for
specific
ranges
of
continuous current ratings
and
wire types.
Except
as
noted,
terminals comply
with
Underwriters
Laboratories,
Inc., Standards UL486A
and
UL486B. Unless otherwise
specified,
F-Frame
circuit
breakers
are
factory equipped
with
load
terminals only.
Ordering
Information
F-Frame
circuit breakers
and
molded
case
switches
have
load terminals
only
as
standard equipment. When
standard line-end
terminals
(same
as
standard
load-end terminals)
are
required,
add
Suffix
L to the
circuit
breaker
Catalog
Number. When non-
standard
or
optional line and/or load
terminals
are
required,
order
by
style
number. Specify
if
factory installation
is
required.
Table
12-37.
Molded
Case
Switches
Maximum
Continuous
Ampere Rating
@40°C
480V
AC
Maximum,
250V
DC
Complete
Circuit
Breaker
with
Load Side Terminals
Only
Catalog
Number
Price
U.S.
S
600V
AC
Maximum,
250V
DC
Complete
Circuit
Breaker
with
Load Side
Terminals
Only
Catalog
Number
Price
U.S.
$
2-Pole
100
150
225
EHD2100K476.FD2100K
FD2150K
FD2225K
535.00
1,135.00
1,135.00
3-Pole
100
150
225
EHD3100K
570.
FD3100K
FD3150K
FD3225K
665.00
1,240.00
1,190.00
4-Pole
100
150
225
E
FD4100K
FD4150K
FD4225K
930.00
1,735.00
1,665.00
Note:
Molded
Case
Switches
may
open
above
1800
amperes.
Note:
Instruction
Leaflet/FRED
Number
29C101
Table
12-38.
Line
and
Load
Terminals
Maximum
Breaker
Amperes
Terminal
Body
Material
Wire Type
AWG
Wire
Range
Metric
Wire
Range
mm2
Package
of 3
Terminals
Catalog
Number
Price
U.S.
$
Standard
Pressure
Type
Terminals
20
(END)
100
225
Steel
Steel
Aluminum
Cu/AI
Cu/AI
Cu/AI
14-10
14-1/0
14-4/0
2.5-
4
2.5-
50
25
- 95
3T20FB
©
3T100FB
3TA225FD
6.10
6.10
89.00
Optional
Pressure
Terminals
50
100
200
225
Aluminum
Aluminum
Stainless
Steel
Aluminum
Cu/AI
Cu/AI
Cu
Cu/AI
14-4
14-1/0
4-4/0
6
-
300
kcmil
2.5-
25
2.5-
50
25
- 95
16
-150
3TA50FB
®
3TA100FD
3T150FB
3TA225FDK
i
6.10
6.10
6.10
89.00
® Not for use
with
ED,
EDH,
EDC
breakers.
®
Includes terminal shield kit. Adds approximately
3
inches
(76.2)
to
breaker
height.
Available
for
use
on
3-pole breaker
only.
Discount
Symbol.
CB-2
CAT.200.01.T.E
For
more
information
contact
Cutler-Hammer
at:
www.ch.cutler-hammer.com/catalog