UNIVERSAL AC INPUT HARMONIC CORRECTION AC-DC
19" COMPATIBLE EUROCARD 100 WATTS MULTIPLE OUTPUT
SWITCHING MODE POWER SUPPLIES HPU100 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
MEET IEC1000-3-2 HARMONIC CORRECTION
MEET UNIVERSAL SAFETY STANDARDS
19” COMPATIBLE EUROCARD FORMAT
EMI MEET EN 55022 & FCC CLASS B
CE MARKING COMPLIANCE
3U X 10HP X 160MM VMEbus STANDARD
GENERAL SPECIFICATION
Efficiency: Typ. 73-76%.
Switching Frequency: Fixed frequency 83K Hz.
Circuit Topology: Fixed frequency forward circuit.
Transient Response: Output voltage returns in less than
3mS following a 25% load change.
Safety Standard: IEC950/UL1950 Class I.
Power Density: 2.0 Watt / Cubic Inch.
Operating Temperature: 0 to +50°C full load. Derates
from +50 to +70°C by derating 2%/°C.
Storage Temperature: -25 to +85°C.
Temperature Coefficient: Typ. 0.04% /°C.
Cooling: Forced air flow is recommended for Ta > +50°C
full load operation.
Construction format: 10HP(TE) X3UX160mm VMEbus
standard Eurocard format.
Note: All measurements are at nominal input, full load, and +25 unless otherwise specified.
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Typ. 90-264Vac with PFC.
Input Connector: DIN 41612 at rear.
Input Frequency: 47-63Hz.
Inrush Current: Typ. <30.6A @ 230Vac.
Input Current: 1.0A @ 115Vac, 0.5A @ 230Vac.
Dielectric Withstand: Meet IEC950.
EMI: Meet EN 55022 & FCC B.
Power Factor Correction: Meet Harmonic Correction
IEC1000-3-2 .PF typ. 0.97-0.98.
Power Indicator: Green LED.
Power OK Signal: Installed.
Logic Inhibit: Installed.
Hold-up Time: 20mS @ 115Vac & 230Vac.
Earth Leakage: Less than 0.40mA @ 230Vac.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Connector: DIN 41612 at rear.
Line Regulation: Typ. 0.5%.
Load Regulation: Main VO1 typ. ±1-2.0%.
Aux.VO2 typ. ±2.0% (Mag. Amp.)
Aux.VO3 typ. ±3.0% (PR).
Noise & Ripple: Typ. 1% peak to peak.
OVP: Built-in at main VO1.
Adjustability: Available at VO1 & VO2.
Overload Protection (OLP): Fully protected against
output overload and short circuit.
Consult the factory for OLP setting.
TOTAL POWER INT'L
OUTPUT VOLTAGE/CURRENT RATINGS CHART
TRIPLE OUTPUT
MAIN VO1 @ AUX. VO2 @ AUX. VO3
MODEL NO. Typ. Volt. Typ. Volt. Typ. Volt.
HPU100-T050IE 7.0A 5.0V 5.0A 12.0V 1.0A 5.0V
HPU100-T050KK
(HPU100-31) 7.0A 5.0V 4.0A 15.0V 0.4A 15.0V
HPU100-T050II
(HPU100-32) 7.0A 5.0V 5.0A 12.0V 0.5A 12.0V
HPU100-T033EI 11.0A 3.3V 9.0A 5.0V 1.0A 12.0V
HPU100-T033KK 10.0A 3.3V 4.0A 15.0V 0.6A 15.0V
HPU100-T033II 10.0A 3.3V 5.0A 12.0V 0.8A 12.0V
Symbol: "" OVP built-in. "@" Adjustable. "#" Remote sensing. "" Magnetic Amplifier.
"" Floating (or isolated) output. "" Installed with Post Regulator.
MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: 920.0g (32.5 Oz.)
SINGLE OUTPUT
MAIN VO1 @#
MODEL NO. T
yp
. Volt.
HPU100-S033250 25.0A 3.3V
HPU100-S050200
(HPU100-10) 20.0A 5.0V
HPU100-S120080 8.0A 12.0V
HPU100-S150075 7.5A 15.0V
HPU100-S240042
(HPU100-13) 4.2A 24.0V
HPU100-S280036 3.6A 28.0V
HPU100-S360028 2.8A 36.0V
HPU100-S480021 2.1A 48.0V
DUAL OUTPUT
MAIN VO1 @ AUX. VO2 @
MODEL NO. T
yp
. Volt. T
yp
. Volt.
HPU100-D050I
(HPU100-20) 8.0A 5.0V 5.0A 12.0V
HPU100-D120I
(HPU100-21) 4.2A 12.0V 4.2A 12.0V
HPU100-D050K 8.0A 5.0V 4.0A 15.0V
HPU100-D150K
(HPU100-23) 3.4A 15.0V 3.4A 15.0V
HPU100-D033I 11.0A 3.3V 5.0A 12.0V
HPU100-D033K 11.0A 3.3V 4.0A 15.0V
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT
AC INPUT SINGLE OUTPUT DUAL OUTPUT TRIPLE OUTPUT Status/
Control
ASSIGNMENT AC-
L
AC-
N
AC-
G +VO1 +S -VO1 -S NC +VO1 -VO1 +VO2 -VO2 NC +VO1 -VO1 +VO2 -VO2 +VO3 -VO3 NC Log.
Inh. P.O k
CNTR & Pin# 28 30 32 4,6 8 12,14 10
16,18,
24,26 4 6 8 10
12,14,16
18,24,26 4,6 8,10 12 14 16 18 24,26 20 22
Mating connector: DIN 41612-H15 Female