ATA-2001 - Analog LVDT/RVDT Signal Conditioner with digital calibration * * * * * * * * * 115 or 220 VAC line powered Microprocessor controlled calibration Superior digital filtering Selectable excitation frequencies & amplitudes Voltage and current outputs 250 to 1000Hz selectable frequency response Auto fall-back synchronization Splash-proof front panel with status LEDs 1/8 DIN standard panel mounting DESCRIPTION The ATA-2001 is a general purpose, AC line-powered, LVDT/RVDT analog signal conditioner with digital setup and calibration. The embedded microprocessor generates a PWM-shaped sine wave and handles all calibration functions. It also controls the demodulation, filtration and synchronization of the LVDT or RVDT transducer signal. All settings are stored in non-volatile memory for restoration on power up. Zero, Gain and Phase adjustments are accomplished via the use of splash-proof front panel pushbuttons and digital voltage dividers. Intended for the most demanding industrial applications, the ATA-2001 is CE certified, and has been rigorously tested to the highest industrial standards for EMI, RFI and ESD. Designed for universal compatibility with 4, 5 and 6 electrical connection transducers, the ATA-2001 provides a wide range of oscillator frequencies, gains and two excitation voltages, affording maximum interface versatility. The very high drive current of 45mA allows operation with transducer input impedances as low as 12 Ohms (with 0.5 VRMS excitation). With high gain capability and low noise, the ATA-2001 provides measurement resolutions beyond most products currently available. The unique auto fall-back synchronization feature allows reliable master/slave operation, for prevention of amplifier cross talk, without the worry of sync signal loss. If the internal processor in a slave amplifier detects an unstable or missing sync signal, the internal clock will take over, continuing at the pre-selected nominal frequency. Upon restoration of a normal sync pulse, the oscillator will return to the slave mode. The ATA-2001 is contained within a rugged, one-piece, extruded aluminum housing which provides optimal amplifier performance under the most rigorous EMI and RFI conditions. An integral panel mounting system provides for convenient 1/8 DIN standard, panel installation. A pre-punched 19" rack adapter is also available to accommodate up to eight amplifiers per adapter installation. Also see our other signal conditioner models, LDM-1000 (DIN rail mount, VDC and 4-20mA output), LVM-110 (VDC input/output), LiM-420 (4-20mA transmitter), PML-1000 (1/8th DIN panel meter, VDC, current and RS485 outputs), and our IEM-422 (NEMA-13 rated 4-20mA transmitter). Measurement Specialties, Inc. (NASDAQ MEAS) offers many other types of sensors and signal conditioners. Data sheets can be downloaded from our web site at: http://www.meas-spec.com/datasheets.aspx MEAS acquired Schaevitz Sensors and the Schaevitz TM FEATURES * * * * trademark in 2000. APPLICATIONS Microprocessor controlled & non-volatile memory Phase shift compensation Auto fall-back synchronization Rugged extruded aluminum housing ATA-2001 Rev. 5 www.meas-spec.com 1/5 * * * * Power-gen turbine control Head box slice lip position control Roller gap position feedback Precision metrology labs 2015-July ATA-2001 - Analog LVDT/RVDT Signal Conditioner with digital calibration PERFORMANCE SPECIFICATIONS ELECTRICAL SPECIFICATIONS Line power requirements Line voltage regulation 115VAC 10%, 50-400Hz; 220VAC 10%, 50-400Hz (switch selectable) 10%, with no change in output Voltage output Unipolar voltage output range Bipolar voltage output range Noise and ripple (voltage output) Output impedance (voltage output) 0 to 10VDC, with 10mA maximum current capability 10VDC (using 100% zero suppression), with 10mA maximum current capability 3mV RMS maximum @ 2.5KHz excitation frequency 1 maximum Current output Current output range Internal loop supply voltage Maximum loop resistance Noise and ripple (current output) 4 to 20mA 18VDC 700 with internal loop supply; 1000 with 24VDC external supply (32vdc MAX) 10A rms (max) Analog outputs frequency response Frequency response @ -3db 250Hz @ 2.5kHz excitation 500Hz @ 5.0kHz excitation 1000Hz @ 10kHz excitation Transducer FSO for 10 VDC output Input impedance Zero suppression range Phase shift compensation range Non-linearity and hysteresis Stability Temperature coefficient of output High gain: 0.04 to 0.9 VRMS; Low gain: 0.5 to 10 VRMS (switch selectable) 100k 110% of FSO 120 degrees maximum 0.05% of FSO, maximum 0.05% of FSO, maximum, after 20 minute warm up 0.02% of FSO per F [0.036% per C] over the operating temperature range Amplifier characteristics Transducer excitation Voltage Current Frequency 0.5 or 3.5 VRMS, sine wave (switch selectable) 45mA RMS maximum 2.5, 5 or 10kHz (switch selectable) Transducer requirements Transducer type Input impedance (Primary) Full scale output LVDT or RVDT with 4, 5 or 6 electrical connections 12 minimum with 0.5 VRMS excitation; 80 minimum with 3.5 VRMS excitation High gain: 0.04 to 0.9 VRMS; Low gain: 0.5 to 10 VRMS ENVIRONMENTAL AND MECHANICAL SPECIFICATIONS Operating temperature range Storage temperature range Weight Transducer electrical connections Output and sync connections Mounting IEC 60529 rating -40F to +185F [-40C to 85C] -40F to +257F [-40C to 125C] 2.1lbs [950 grams] DB-9S (See our transducer data sheets for jumper cables or connector option) Barrier terminal strip 1/8 DIN standard panel mounting (19" rack adapter for 8-up available) IP61 (Front panel only) Notes: All values are nominal unless otherwise noted FSO (Full Scale Output) is the largest absolute value of the outputs measured at the range ends ATA-2001 Rev. 5 www.meas-spec.com 2/5 2015-July ATA-2001 - Analog LVDT/RVDT Signal Conditioner with digital calibration WIRING - INPUT (TRANSDUCER) WIRING - OUTPUT ATA-2001 Rev. 5 www.meas-spec.com 3/5 2015-July ATA-2001 - Analog LVDT/RVDT Signal Conditioner with digital calibration DIMENSIONS DIMENSIONS - RACK ADAPTOR (SOLD SEPARATELY) Accommodates up to eight ATA-2001 Amplifiers Dimensions are in inch (mm) ATA-2001 Rev. 5 www.meas-spec.com 4/5 2015-July ATA-2001 - Analog LVDT/RVDT Signal Conditioner with digital calibration ORDERING INFORMATION Description ATA-2001 LVDT/RVDT Signal Conditioner Rack Adaptor for up to 8 signal conditioners (ATA-2001 conditioners not included) Cable to connect HCA/HCI Series LVDTs, GCA Series Gage Heads, and R36AS RVDT to ATA-2001 (1) (PTO6A-10-6S to DB-9P connector) Extension cable to connect LBB Series (option -004) Gage Heads to ATA-2001 (1) Part Number 02291327-000 05290032-000 04290457-000 04290565-000 (DB-9S to DB-9P connector) Extension Cable to connect LBB (option -001) to ATA-2001 (1) 04290577-000 (PTO6A-10-6S to DB-9P connector) (1) All cables are shielded, 10 foot long, and are rated 80C [176F] operating. Consult factory for other lengths. Download the operation manual: http://www.meas-spec.com/manuals.aspx TECHNICAL CONTACT INFORMATION NORTH AMERICA EUROPE ASIA Measurement Specialties, Inc. 1000 Lucas Way Hampton, VA 23666 United States Phone: +1-800-745-8008 Fax: +1-757-766-4297 Email: sales@meas-spec.com Web: www.meas-spec.com MEAS Deutschland GmbH Hauert 13 D-44227 Dortmund Germany Phone: +49-(0)231-9740-0 Fax: +49-(0)231-9740-20 Email: info.de@meas-spec.com Web: www.meas-spec.com Measurement Specialties China Ltd. No. 26, Langshan Road High-tech Park (North) Nanshan District, Shenzhen 518057 China Phone: +86-755-33305088 Fax: +86-755-33305099 Email: info.cn@meas-spec.com Web: www.meas-spec.com The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer's technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others. ATA-2001 Rev. 5 www.meas-spec.com 5/5 2015-July