Click on Series name for product info on aimtec.com Series AM1A-Z 1 Watt | DC-DC Converter FEATURES: * * * * * RoHS compliant Regulated output voltage Low ripple and noise High efficiency up to 81% No Minimum Load Required * * * * * Operating temperature -40oC to + 85oC Input / Output Isolation 1500 VDC Pin compatible with multiple manufacturers 6 pin SIP package Wide 2:1 Input Range Models Single output Model AM1A-0505SZ AM1A-0512SZ AM1A-0515SZ AM1A-0524SZ AM1A-1205SZ AM1A-1212SZ AM1A-1215SZ AM1A-1224SZ AM1A-2405SZ AM1A-2412SZ AM1A-2415SZ AM1A-2424SZ AM1A-4805SZ AM1A-4812SZ AM1A-4815SZ AM1A-4824SZ FL= Full Load Input Voltage (VDC) Low line Input current FL (mA) 4.5 - 9 4.5 - 9 4.5 - 9 4.5 - 9 9 - 18 9 - 18 9 - 18 9 - 18 18 - 36 18 - 36 18 - 36 18 - 36 36 - 75 36 - 75 36 - 75 36 - 75 289 278 275 275 141 138 136 138 71 68 69 68 36 35 34 34 Input Current FL | No Load (mA) 263 253 250 250 107 105 103 105 54 52 52 52 28 27 27 27 35 35 35 35 20 20 20 20 10 10 10 10 7 7 7 7 Output Voltage (VDC) Output Current (mA) Isolation (VDC) Max Capacitive Load (uF) 5 12 15 24 5 12 15 24 5 12 15 24 5 12 15 24 200 83 67 42 200 83 67 42 200 83 67 42 200 83 67 42 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1680 820 680 470 1680 820 680 470 1680 820 680 470 1680 820 680 470 Efficiency (Full load) (%) 76 79 80 80 78 80 81 80 78 80 80 81 76 78 78 77 Models Dual output Model AM1A-0512DZ AM1A-0515DZ AM1A-1212DZ AM1A-1215DZ AM1A-2412DZ AM1A-2415DZ AM1A-4812DZ AM1A-4815DZ FL= Full Load Input Voltage (VDC) Low line Input current FL (mA) 4.5 - 9 4.5 - 9 9 - 18 9 - 18 18 - 36 18 - 36 36 - 75 36 - 75 285 282 138 138 69 70 34 35 Input Current FL | No Load (mA) 259 254 106 105 52 53 27 27 35 35 20 20 10 10 7 7 Output Voltage (VDC) Output Current (mA) Isolation (VDC) Max Capacitive Load (uF) Efficiency (Full load) (%) 12 15 12 15 12 15 12 15 42 33 42 33 42 33 42 33 1500 1500 1500 1500 1500 1500 1500 1500 470 330 470 330 470 330 470 330 77 79 79 80 80 79 77 77 Input Specifications Parameters Voltage range Nominal 5 12 15 24 Filter Turn on Transient process time Startup time Absolute Maximum Rating www.aimtec.com F 051e R12.G 5 Vin 12 Vin 15 Vin 24 Vin Typical 4.5 - 9 9 - 18 18 - 36 36 - 75 Capacitor 1 50 0-15 0-25 0-50 0-100 Tel: +1 514 620 2722 1 of 4 Maximum Units VDC ms ms VDC Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1A-Z 1 Watt | DC-DC Converter Peak Input Voltage time Input Reflected Ripple Current Transient Recovery time Transient Response Deviation 100 35 500 3 See application circuit 25% load step change 25% load step change ms mA pk-pk s % Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance Conditions Typical 60 sec Rated Units 1500 VDC MOhm pF > 1000 70 Output Specifications Parameters Voltage accuracy Short Circuit protection Line voltage regulation (Single) Load voltage regulation (Single) Load voltage regulation (Dual) Cross Regulation (Dual) Temperature coefficient Ripple & Noise* Conditions Typical Maximum 2 Continuous with auto recovery 0.2 0% to 100% load 1.0 0% to 100% load 2.0 25% to 100% coupled to full load 5 0.02 At 20MHz Bandwidth 50 Units % % % % % %/oC mV p-p *Measured with a 1F ceramic capacitor. General Specifications Parameters Switching frequency Max Case temperature Operating temperature Storage temperature Derating Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Conditions Typical 100% load 150 - 550 Maximum +105 Full Load without Derating -40 to +85 -55 to +125 Not Required Free air convection Units KHz oC oC oC 95 % Non conductive black plastic 3.0 g 0.67 x 0.30 x 0.43 inch 17.0 x 7.62 x 11.0 mm >2,800,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified Safety Specifications Parameters Agency Approval & Safety Standard CE, UL UL60950-1 EN 55032, Class A (external reference circuit below) IEC 61000-4-2: 2008 IEC 61000-4-3: 2010 IEC 61000-4-4: 2012* IEC 61000-4-5: 2005* IEC 61000-4-6: 2008 IEC 61000-4-8: 2009 *External filter capacitor for 5Vin 330F/100V EEC & all other models 220F/100V EEC www.aimtec.com F 051e R12.G Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1A-Z 1 Watt | DC-DC Converter Recommended Surge Protective Circuit Vin+ + Vo+ C1 Vin- - Load Aimtec DC-DC Converter Vo- C1: 5V input models = 330 F / 100V, all other models = 220 F / 100V Recommended Circuits for Conducted Emissions Single Output Dual Output L1 L1 Load C1 Vin- Aimtec DC-DC Com Converter C1 Vo- - Vo+ + Aimtec DC-DC Converter Vo- - C2 Load Vo+ + Load Vin+ C2 Model C1 L1 C2 5 Vin 12 Vin 24 Vin 48 Vin MLCC 4.7 F / 50V MLCC 4.7 F / 50V MLCC 4.7 F / 50V MLCC 4.7 F / 100V 4.7 H 4.7 H 18 H 18 H MLCC 220pF / 3kV MLCC 220pF / 3kV MLCC 220pF / 3kV MLCC 220pF / 3kV Input Reflected Ripple Test Circuit Test Point + Vo+ Aimtec DC-DC Converter Cin 47F - RL (Full Load) Lin 12H Vo- * Tested at full load, and nominal input Pin Out Specifications Pin Single Dual 1 2 4 5 6 - V Input + V Input + V Output No pin - V Output - V Input + V Input + V Output Common - V Output Dimensions www.aimtec.com F 051e R12.G Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1A-Z 1 Watt | DC-DC Converter 17.00 (0.67) 7.62 (0.03) Printed Face 10.50 (0.41) 11.00 (0.43) AM1A-XXXXSZ O1.0 (0.039) 5 HOLES XXXX 0.50 (0.02) 3.50 (0.14) 5.08 (0.20) 2.15 (0.08) 12.70 (0.50) 2.54 (0.10) NOTE: Unit mm [inch] Pin tolerances: 0.10mm [ 0.004inch] General tolerances: 0.25mm [ 0.010inch] 0.50 (0.02) 1 2.50 (0.10) 2 4 5 6 7.62 (0.30) 2.54 (0.1) 0.50 (0.02) 2.54 (0.1) Unless otherwise stated all dimensions in millimeters (inches) 0.5mm. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec's standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.G Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only