(1/2)
004-01 / 20080818 / e916_zug_11.fm
• All specifications are subject to change without notice.
EMC Filters for AC Power Line
Inlet-socket Type ZUG-11, ZUG-11A Series
FEATURES
• These IEC-type inlet sockets incorporate small, high-
performance EMC filters with outstanding attenuation
characteristics for both common mode and differential mode
noise components.
• Leakage current is maintained at less than 0.5mA
• Two types of connection terminals are offered: Faston® #250
(ZUG-11 series, t: 0.8mm) or lug terminal (ZUG-11A series).
• Effcient manufacturing makes these filters highly cost -effective.
• It is a product conforming to RoHS directive.
APPLICATIONS
Personal computers, computer terminals, office automation equip-
ment, digital applied devices (ECRs, electronic calculators, elec-
tronic scales, etc.), measurement devices, medical equipment, and
any other devices that require a miniaturized high-performance fil-
ter.
SAFETY STANDARDS
SHAPES AND DIMENSIONS
ZUG-11
Typical dimensions for installation
ZUG-11A
Conformity to RoHS Directive
Part No.
Standard and standard No.
U.S.A. Canada Europe
UL1283 CSA C22.2 No.8 EN60939
ZUG2203-11 E62388 LR76849C P08208996
ZUG2203-11A E62388 LR76849C P08208996
ZUG2206-11 E62388 LR76849C P08208996
ZUG2206-11A E62388 LR76849C P08208996
ZUG2210-11 E62388 LR76849C P08208996
ZUG2210-11A E62388 LR76849C P08208996
UL CSA NEMKO
30.5
40
48
ø3.3
25 55.3
38.15.2
Ground terminal
Faston®
•Case: metal, input terminal: inlet socket(EN60320)
output terminal: Faston® #250(-11 series, t: 0.8mm),
lug terminal(-11A series)
•Tighten the panel mounting M3 dia. bolt with the torque under 5.88×10–1N•m.
31.2
40
23.2
ø3.6
R5.5
From back side panel
30
40
21.5
ø3.6 or M3 tap
R3.5
From front panel
Dimensions in mm
30.5
40
48
ø3.3
25 53.3
38.15.2
Ground terminal
Lug terminal
• Faston® is a registered trademark of Tyco Electronics AMP Corp. Incorporated.
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.