MODEL FCA50F-24
MAX OUTPUT WATTAGE[W] 50(Peak 160)
DC OUTPUT 24V 2.1(Peak 6.7)A
SPECIFICATIONS
MODEL FCA50F-24
INPUT
VOLTAGE[V] AC187 - 528 1for DC265 - 746
CURRENT[A]
ACIN 240V
0.55typ
ACIN 480V
0.30typ
FREQUENCY[Hz] 50/60 (47-63
)
EFFICIENCY[%]
ACIN 240V
82typ
ACIN 480V
78typ
INRUSH CURRENT[A]
ACIN 240V
25typ (At cold start)(
At Room Temperature)
ACIN 480V
50typ (At cold start)(
At Room Temperature)
LEAKAGE CURRENT[mA] 0.75max (60Hz,According to IEC60950)
OUTPUT
VOLTAGE[V] 24
CURRENT[A]
*1
2.1 (Peak 6.7)
LINE REGULATION[mV] 96max
LOAD REGULATION[mV]
0 - 2.1A
150max
0 - 6.7A
480max
RIPPLE[mVp-p]
0to+50
C
*2
240max
-10-0
C
*2
320max
RIPPLE NOISE[mVp-p]
0to+50
C
*2
680max
-10-0
C
*2
720max
TEMPERATURE REGULATION[mV]
-10 to +50C
600max
DRIFT[mV]
*5
100max
START-UP TIME[ms] 800max (ACIN 240V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 240V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
21.6 - 26.4
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of peak current and recovers automatically
OVERVOLTAGE PROTECTION
Works at 115 - 140% of rating
OPERATING INDICATION LED (Green)
ISOLATION
INPUT-OUTPUT AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +70C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION
*3
10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT
*3
196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,C-UL,EN60950-1
CONDUCTED NOISE Complies with FCC-A,CISPR11-A,EN55011-A
OTHERS CASE SIZE/WEIGHT
*4
50X125X124mm (WXHXD)/ 640g max
COOLING METHOD Convection
*1Peak current for 150ms in a 30seconds period is acceptable.
*2In case of rated input/output(ACIN240-480v/2.1A), either the 20MHz oscilloscope or the ripple noise meter(equivalent to Keisokugiken:RM101) is used.
*3Option with DIN rail attachment(N1) is only for direction X(refer to sec4.2 in manual).
*4Depth of power supply is 132mm with DIN rail attachment.
*5Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*6Please contact us about safety approvals for the model with option.
FCA50F
AC-DC Power Supplies Enclosed type
FCA 50 F -24 -O
Ordering information
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional *6
N1
:with DIN rail attach-
ment
R
12345
FCA
FCA-2
¡RISE TIME & FALL TIME
¡STATIC CHARACTERISTICS
OUTPUT VOLTAGE V
OUTPUT VOLTAGE V
RIPPLE mVp-p
INPUT VOLTAGE V 60Hz
¡INRUSH CURRENT
¡OVERCURRENT CHARACTERISTICS
OUTPUT CURRENT A
Io=100%
Ripple
Output Voltage
(AC 100V)
Io=100%
Io=50%
DC Output
AC Input
ACIN 480V
50ms/DIV
OUTPUT VOLTAGE V
50ms/DIV
20A/DIV
Input Voltage AC480V 60Hz
100%
Input voltage AC480V
Frequency
Load
150 160 170 180 190 200 210 220 230 240 250
24
22
20
18
16
14
12
10
825
50
75
100
25
20
15
10
5
0
26
24
22
20
18
16
14
12
24681012
FCA
FCA-3
FCA50F
External view
Terminal
Block
(M4)
+V
-V
FG
AC(L)
AC(N)
+
-
FG
AC(L)
AC(N)
FCA50F-24
(22)
(12)
(7)
(116)
(72)
(35.5)
(8)
(110)
(102)
(34)
(24.5)
(15.5)
(11.5)
13max
13 10
124
125
LED
Voltage Adjust
7
16
50
30
Spacer
FCA50F-24-N1 only
FCA50F-24-N1 only
DIN Rail Attachment
71.1
±
0.5
25.4
±
0.5
45.9
18max
50
44.5
25.4
Terminal Block Cover
119
º
3.8
3-M3 Mounting Hole
12.7
Weight : 640g or less
Tolerance : ±1
Mounting torque : 0.6Nm
(6.3kgfcm)max
Dimensions in mm.
Performance data
MODEL FCA75F-24
MAX OUTPUT WATTAGE[W] 75(Peak 240)
DC OUTPUT 24V 3.1(Peak 10)A
SPECIFICATIONS
MODEL FCA75F-24
INPUT
VOLTAGE[V] AC187 - 528 1for DC265 - 746
CURRENT[A]
ACIN 240V
0.80typ
ACIN 480V
0.45typ
FREQUENCY[Hz] 50/60 (47-63
)
EFFICIENCY[%]
ACIN 240V
82typ
ACIN 480V
78typ
INRUSH CURRENT[A]
ACIN 240V
25typ (At cold start)(
At Room Temperature)
ACIN 480V
50typ (At cold start)(
At Room Temperature)
LEAKAGE CURRENT[mA] 0.75max (60Hz,According to IEC60950)
OUTPUT
VOLTAGE[V] 24
CURRENT[A]
*1
3.1 (Peak 10)
LINE REGULATION[mV] 96max
LOAD REGULATION[mV]
0 - 3.1A
150max
0 - 10A 480max
RIPPLE[mVp-p]
0to+50
C
*2
240max
-10-0
C
*2
320max
RIPPLE NOISE[mVp-p]
0to+50
C
*2
680max
-10-0
C
*2
720max
TEMPERATURE REGULATION[mV]
-10 to +50C
600max
DRIFT[mV]
*5
100max
START-UP TIME[ms] 800max (ACIN 240V,Io=100%)
HOLD-UP TIME[ms] 10typ (ACIN 240V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
21.6 - 26.4
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of peak current and recovers automatically
OVERVOLTAGE PROTECTION
Works at 115 - 140% of rating
OPERATING INDICATION LED (Green)
ISOLATION
INPUT-OUTPUT AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +70C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION
*3
10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT
*3
196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,C-UL,EN60950-1
CONDUCTED NOISE Complies with FCC-A,CISPR11-A,EN55011-A
OTHERS CASE SIZE/WEIGHT
*4
65X125X124mm (WXHXD)/ 750g max
COOLING METHOD Convection
*1Peak current for 150ms in a 30seconds period is acceptable.
*2In case of rated input/output(ACIN240-480v/3.1A), either the 20MHz oscilloscope or the ripple noise meter(equivalent to Keisokugiken:RM101) is used.
*3Option with DIN rail attachment(N1) is only for direction X(refer to sec4.2 in manual).
*4Depth of power supply is 132mm with DIN rail attachment.
*5Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*6Please contact us about safety approvals for the model with option.
FCA75F
AC-DC Power Supplies Enclosed type
FCA 75 F -24 -O
Ordering information
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional *6
N1
:with DIN rail attach-
ment
R
12345
FCA
FCA-4
¡RISE TIME & FALL TIME
¡STATIC CHARACTERISTICS
OUTPUT VOLTAGE V
OUTPUT VOLTAGE V
RIPPLE mVp-p
INPUT VOLTAGE V 60Hz
¡INRUSH CURRENT
¡OVERCURRENT CHARACTERISTICS
OUTPUT CURRENT A
Io=100%
Ripple
Output Voltage
(AC 200V)
Io=100%
Io=50%
DC Output
AC Input
ACIN 480V
50ms/DIV
OUTPUT VOLTAGE V
50ms/DIV
20A/DIV
Input Voltage AC480V 60Hz
100%
Input voltage AC480V
Frequency
Load
150 160 170 180 190 200 210 220 230 240 250
24
22
20
18
16
14
12
10
825
50
75
100
25
20
15
10
5
0
26
24
22
20
18
16
14
12
24681012
FCA
FCA-5
FCA75F
External view
Terminal
Block
(M4)
+V
-V
FG
AC(L)
AC(N)
+
-
FG
AC(L)
AC(N)
FCA75F-24
(37)
(12)
(7)
(116)
(72)
(35.5)
(8)
(110)
(102)
(34)
(24.5)
(15.5)
(11.5)
13max
13 10
124
125
LED
Voltage Adjust
7
18
65
45
Spacer
FCA75F-24-N1
only
FCA75F-24-N1
only
DIN Rail
Attachment
71.1
±
0.5
38.1
±
0.5
45.9
18max
64.5
59.5
31.75
Terminal Block Cover
119
º
3.8
3-M3 Mounting Hole
12.7
Weight : 750g or less
Tolerance : ±1
Mounting torque : 0.6Nm
(6.3kgfcm)max
Dimensions in mm.
Performance data
MODEL FCA200F-24
MAX OUTPUT WATTAGE[W] 200 (Peak 1,008)
DC OUTPUT 24V 8.4 (Peak 42)A
SPECIFICATIONS
MODEL FCA200F-24
INPUT
VOLTAGE[V] AC187 - 528 1for DC265 - 530
CURRENT[A]
ACIN 240V
1.10typ
ACIN 480V
0.55typ
FREQUENCY[Hz] 50/60 (47-63
)
EFFICIENCY[%]
ACIN 240V
81typ
ACIN 480V
81typ
POWER FACTOR
ACIN 240V
0.98typ
ACIN 480V
0.93typ
INRUSH CURRENT[A]
ACIN 240V
25typ (At cold start)(
At Room Temperature)
ACIN 480V
50typ (At cold start)(
At Room Temperature)
LEAKAGE CURRENT[mA] 1.5max (60Hz,According to IEC60950)
OUTPUT
VOLTAGE[V] 24
CURRENT[A]
*1
8.4 (Peak 42)
LINE REGULATION[mV] 96max
LOAD REGULATION[mV]
0 - 8.4A
150max
RIPPLE[mVp-p]
0to+50
C
*2
240max
-10-0
C
*2
320max
RIPPLE NOISE[mVp-p]
0to+50
C
*2
680max
-10-0
C
*2
720max
TEMPERATURE REGULATION[mV]
-10 to +50C
600max
DRIFT[mV]
*5
100max
START-UP TIME[ms] 800max (ACIN 240V,Io=100%)
HOLD-UP TIME[ms] 100typ (ACIN 240V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
21.6 - 26.4
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of peak current and recovers automatically
OVERVOLTAGE PROTECTION
Works at 115 - 140% of rating
OPERATING INDICATION LED (Green)
ISOLATION
INPUT-OUTPUT AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +60C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION
*3
10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT
*3
196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,C-UL,EN60950-1
CONDUCTED NOISE Complies with FCC-A,CISPR11-A,EN55011-A
OTHERS CASE SIZE/WEIGHT
*4
150X125X125mm (WXHXD)/1
,700g max
COOLING METHOD Convection
*1Peak current for 50ms in a 30seconds period is acceptable.
*2In case of rated input/output(ACIN240-480v/8.4A), either the 20MHz oscilloscope or the ripple noise meter(equivalent to Keisokugiken:RM101) is used.
*3Option with DIN rail attachment(N1) is only for direction X(refer to sec4.2 in manual).
*4Depth of power supply is 133mm with DIN rail attachment.
*5Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*6Please contact us about safety approvals for the model with option.
FCA200F
AC-DC Power Supplies Enclosed type
FCA 200 F -24 -O
Ordering information
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional *6
N1
:with DIN rail attach-
ment
R
12345
FCA
FCA-6
¡RISE TIME & FALL TIME
DC Output
AC Input
Io=100%
100ms/DIV
ACIN 480V
¡INPUT HARMONIC CURRENT (FCA200F-24)
(FCA200F-24)(FCA200F-24)
(FCA200F-24)
Harmonic current standard class A
(at odd number)
Load factor
Input voltage AC
100%
240V
HARMONIC ORDER
HARMONIC CURRENT A
¡INRUSH CURRENT
¡OVERCURRENT CHARACTERISTICS
OUTPUT CURRENT A
OUTPUT VOLTAGE V
50ms/DIV
20A/DIV
Input Voltage AC480V 60Hz
100%
Input voltage AC480V
Frequency
Load
30
25
20
15
10
5
20 40 60 80
OUTPUT VOLTAGE V
25
20
15
10
5
0
03040
0.001
0.01
0.1
1
10
10 20
FCA
FCA-7
FCA200F
External view
t
0.5
t
0.5
Name Plate
+
ADJ
V
AC(N)
AC(L)
FG
+V
-V
+V
-V
3-Spacer
FCA200F-O-N1 only
¶ Mounting torque:0.6N m(6.3kgf cm)max
¶ Weight:1700g or less.
¶ Dimensions in mm
¶ Material Electric galvanizing steel board
¶ Tolerance ±1
4-M4
Mounting Hole
7-M4
3-DIN Rail Attachment
FCA200F-O-N1 only
¶ Mounting Hole
LED for confirming
of output
2-Terminal Block Cover
Voltage Adjust
10 13 (20)
(38)
20max 125
(72)
(23)
(7)
(7)
125
(73.5)
150
(12)
127
101.6
(12.4)
(35.5)
(92.5)
(58)
(97)
(98)
(29) (43)
(11) (56)
(20) (20)
(8)
(50) (50)
FCA200F
Performance data
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Cosel:
FCA200F-24 FCA200F-24-C FCA200F-24-CN1 FCA200F-24-N1 FCA50F-24-C FCA50F-24-CN1 FCA50F-24-N1
FCA75F-24-C FCA75F-24-CN1 FCA75F-24 FCA50F-24 FCA75F-24-N1