https://www.phoenixcontact.com/us/products/2906755 Surge protection device-TTC-6P-2-HC-M-24DC-PT-I-2906755 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Surge protection, consisting of protective plug and base element, with integrated status indicator and knife disconnection for a 2-wire floating signal circuit with high nominal current. Your advantages Space-saving and cost-saving with a narrow overall width of just 6mm Continuous monitoring of protective devices, plus mechanical status indicator with optional remote signaling Finding the right product for all possible requirements in MCR applications is easy, thanks to the complete range of products with customized features Easy testing and documentation with CHECKMASTER2 with pluggable protective modules The signal is not influenced during maintenance work, thanks to the impedance-neutral insertion and removal of protective plugs Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626134864 Weight per Piece (excluding packing) 40.000 g Custom tariff number 85363010 Country of origin Germany Technical data Dimensions Height 105.8 mm Width 6.2 mm +0.1mm Depth 100 mm (incl. DIN rail 7.5mm) 05/19/2021Page1/8 https://www.phoenixcontact.com/us/products/2906755 Surge protection device-TTC-6P-2-HC-M-24DC-PT-I-2906755 Technical data Ambient conditions Ambient temperature (operation) -40 C ... 85 C Ambient temperature (storage/transport) -40 C ... 85 C Permissible humidity (operation) 5 % ... 95 % Altitude 4000 m (amsl (above mean sea level)) Degree of protection IP20 General Housing material PBT Flammability rating according to UL 94 V-0 Color traffic grey A RAL 7042 light grey RAL 7035 Mounting type DIN rail: TH 35 - 7.5 mm Type DIN rail module, two-section, divisible Direction of action Line-Line & Line-Signal Ground/Shield & optional Signal Ground/ShieldEarth Ground Protective circuit IEC test classification C1 C2 C3 D1 Nominal voltage UN 24 VDC Maximum continuous voltage UC 30 VDC 21 VAC Rated current 6 A (55C) Operating effective current IC at UC 5 A Residual current IPE 1 A Nominal discharge current In (8/20) s (line-line) 0.5 kA Nominal discharge current In (8/20) s (line-earth) 5 kA Pulse discharge current Iimp (10/350)s (line-earth) 0.5 kA Total discharge current Itotal (8/20)s 5 kA Voltage protection level Up (line-line) 50 V (C1 - 1 kV/500 A) 45 V (C3 - 25 A) 50 V (C3 - 100 A) Voltage protection level Up (line-earth) 1.35 kV (C1 - 1 kV/500 A) 1.45 kV (C2 - 10 kV / 5 kA) 850 V (C3 - 25 A) 1.1 kV (C3 - 100 A) 05/19/2021Page2/8 https://www.phoenixcontact.com/us/products/2906755 Surge protection device-TTC-6P-2-HC-M-24DC-PT-I-2906755 Technical data Protective circuit Response time tA (line-line) 1 ns Response time tA (line-earth) 100 ns Input attenuation aE, sym. typ. 0.3 dB ( 300 kHz / 150 ) Cut-off frequency fg (3dB), sym. in 150 system typ. 1 MHz Capacity (line-earth) typ. 2.2 nF Resistance per path 100 m Surge protection fault message optical Max. required back-up fuse 6.3 A (FF) Impulse durability (line-line) C1 - 1kV / 500A C3 - 100A Impulse durability (line-earth) C1 - 1kV / 500A C2 - 10kV / 5kA C3 - 100A D1 - 500A Pulse reset time (line-earth) 40ms Connection data Connection method Push-in connection Stripping length 8 mm Conductor cross section flexible 0.2 mm ... 2.5 mm Conductor cross section solid 0.2 mm ... 4 mm Conductor cross section AWG 24 ... 12 Standards and Regulations Standards/specifications IEC61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012 EN61643-21 2001 + A1:2009 + A2:2013 Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings 05/19/2021Page3/8 https://www.phoenixcontact.com/us/products/2906755 Surge protection device-TTC-6P-2-HC-M-24DC-PT-I-2906755 Pictogram Diagram 8 I [A] U 6 4 2 40 50 60 70 80 T [C] Dimensional drawing 105,8 90 Circuit diagram 6,2 1 4 protected unprotected 5 92,5 100 2 3 ! 6 Classifications eCl@ss eCl@ss 10.0.1 27130807 eCl@ss 11.0 27130807 eCl@ss 4.0 27140201 eCl@ss 4.1 27130801 eCl@ss 5.0 27130801 eCl@ss 5.1 27130801 eCl@ss 6.0 27130800 eCl@ss 7.0 27130807 eCl@ss 9.0 27130807 ETIM ETIM 2.0 EC000943 ETIM 3.0 EC000943 ETIM 4.0 EC000943 ETIM 6.0 EC000943 ETIM 7.0 EC000943 UNSPSC UNSPSC 6.01 30212010 UNSPSC 7.0901 39121610 UNSPSC 11 39121610 05/19/2021Page4/8 https://www.phoenixcontact.com/us/products/2906755 Surge protection device-TTC-6P-2-HC-M-24DC-PT-I-2906755 Classifications UNSPSC UNSPSC 12.01 39121610 UNSPSC 13.2 39121620 UNSPSC 18.0 39121620 UNSPSC 19.0 39121620 UNSPSC 20.0 39121620 UNSPSC 21.0 39121620 Approvals Approvals Approvals DNV GL / CSA / UL Listed / CSAus / cCSAus Ex Approvals Approval details DNV GL https://approvalfinder.dnvgl.com/ TAE000027G CSA http://www.csagroup.org/services-industries/product-listing/ 70136717 UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 138168 CSAus http://www.csagroup.org/services-industries/product-listing/ 70136717 cCSAus 05/19/2021Page5/8 https://www.phoenixcontact.com/us/products/2906755 Surge protection device-TTC-6P-2-HC-M-24DC-PT-I-2906755 Accessories Accessories End block End clamp-CLIPFIX 35-5-3022276 Quick mounting end clamp for NS 35/7,5 DIN rail or NS 35/15 DIN rail, with marking option, with parking option for FBS...5, FBS...6, KSS 5, KSS 6, width: 5.15 mm, color: gray Labeled terminal marker Zack Marker strip, flat-ZBF 6 CUS-0825027 Zack Marker strip, flat, Strip, can be ordered: Strip, white, labeled according to customer specifications, mounting type: snap into flat marker groove, for terminal block width: 6.2 mm, lettering field size: 5.15 x 6.15 mm, Number of individual labels: 10 Zack Marker strip, flat-ZBF 6,QR:FORTL.ZAHLEN-0808765 Zack Marker strip, flat, Strip, white, labeled, Printed vertically: consecutive numbers 1 ... 10, 11 ... 20, etc. up to 91 ... 100, mounting type: snap into flat marker groove, for terminal block width: 6.2 mm, lettering field size: 5.15 x 6.15 mm, Number of individual labels: 10 Marker pen Marker pen-X-PEN 0,35-0811228 Marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line thickness 0.35 mm Terminal marking 05/19/2021Page6/8 https://www.phoenixcontact.com/us/products/2906755 Surge protection device-TTC-6P-2-HC-M-24DC-PT-I-2906755 Accessories Zack Marker strip, flat-ZBF 6:UNBEDRUCKT-0808710 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into flat marker groove, for terminal block width: 6.2 mm, lettering field size: 5.15 x 6.15 mm, Number of individual labels: 10 Zack Marker strip, flat-ZBF 6/WH-100:UNBEDRUCKT-0808736 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into flat marker groove, for terminal block width: 6.2 mm, lettering field size: 5.15 x 6.15 mm, Number of individual labels: 10 Additional products Remote signaling set-TTC-6-FMRS-PT-2907811 Module set for the optical monitoring and floating remote signaling of adjacent surge protective devices in the TERMITRABcomplete or CLIXTRAB product family. Suitable for directly grounded DIN rails. Shield connection-SSA 3-6-2839295 Shield fast connection for 3 ... 6 mm cable diameter. Potential connecting cable: 200 mm, 1 mm, color: black Shield connection-SSA 5-10-2839512 Shield fast connection for 5 ... 10 mm cable diameter. Potential connecting cable: 200 mm, 1 mm, color: black 05/19/2021Page7/8 https://www.phoenixcontact.com/us/products/2906755 Surge protection device-TTC-6P-2-HC-M-24DC-PT-I-2906755 Accessories Spare parts Surge protection plug-TTC-6P-2-HC-24DC-I-P-2907845 Surge protection plug with integrated status indicator on the module for a 2-wire floating signal circuit with high nominal current. Nominal voltage: 24VDC Phoenix Contact 2021 (c) - all rights reserved http://www.phoenixcontact.com 05/19/2021Page8/8