SMD Infrared LED
OP270 Series
OPTEK Technology Inc.— 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (800) 341-4747 FAX: (972) 323– 2396 sensors@optekinc.com www.optekinc.com
Electrical Characteristics (TA = 25°C unless otherwise noted)
Absolute Maximum Ratings
TA = 25o C unless otherwise noted
Storage Temperature Range -40° C to +85° C
Operating Temperature Range -40° C to +85° C
Lead Soldering Temperature 260° C(1)
Reverse Voltage 30 V
Continuous Forward Current 50 mA
Power Dissipation 130 mW(2)
Notes:
1. Solder time less than 5 seconds at temperature extreme.
2. De-rate linearly at 2.17 mW/° C above 25° C.
SYMBOL PARAMETER MIN MAX UNITS CONDITIONS
Ee(APT) Apertured Radiant Incidence 1.5 mW/cm2 IF = 20mA(3)
VF Forward Voltage 1.5 V IF = 20mA
IR Reverse Current 100 µA VR = 2.0V
λP Peak Emission Wavelength nm IF = 10mA
tr, tf Rise and Fall Time 500 ns IF(PEAK) = 100mA, PW = 10µs, 10% D.C.
TYP
890
ΘHP Emission Angle at Half Power Points 25 Deg. IF = 20mA
3. Ee(APT) is a measurement of the apertured radiant incidence upon a sensing area 0.081” (2.06mm) in diameter, perpendicular to and cen-
tered on the mechanical axis of the lens, and 0.590” (14.99mm) from the measurement surface. Ee(APT) is not necessarily uniform within
the measured area.
100°C
-40°C
Relative Radiant Intensity vs.
Forward Current vs. Temperature
0 10 20 30 40 50
Forward Current (mA)
Relative Radiant Intensity
100%
150%
200%
250%
300%
350% Normalized at IF = 20mA,
TA = 20°C. Temperatures
stepped in 20°C Increments
50%
0% 1.0
1.1
1.2
1.3
1.4
1.5
Forward Voltage (V)
Forward Voltage vs. Forward
Current vs. Temperature
0 10 20 30 40 50
Forward Current (mA)
-40°C
100°C
Temperatures stepped in 20°C
Increments
Issue 1.0 04.05