- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
Continuous, Automatic recovery
Output Current Limitation
500 µs max. (25% Load Step)
- IT / Multimedia Equipment
EN 62368-1
IEC 62368-1
UL 62368-1
- Certification Documents
www.tracopower.com/overview/tel8wi
EN 55032 class A (internal filter)
EN 55032 class B (with external filter)
EN 55032 class A (with external filter)
- Electrostatic Discharge
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 20 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 100 A/m, perf. criteria A
EN 61000-4-8, 1000 A/m, perf. criteria A
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.