POWER LPS200-M Series 250 Watts Data Sheet Total Power: 125 - 250 Watts Input Voltage: 90 - 264 Vac # of Outputs: Single SPECIAL FEATURES Medical and ITE safeties Active power factor correction 3" x 5" footprint Less than 1U high EN61000-3-2 compliant Remote sense Power fail Adjustable main output Built-in Class B EMI filter Overvoltage protection Overload protection Thermal overload protection Isolated 12 V Fan output LPX200 enclosure kit available RoHS compliant SAFETY TUV UL cULus CB CE Electrical Specifications Input Input range 90 - 264 Vac; 120 - 300 Vdc Frequency 47 - 63 Hz Inrush current 50 A max., cold start @ 25 C Efficiency 86% typical at full load EMI/RFI FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted Power factor 0.99 typical Safety ground leakage current 275 A @ 50/60 Hz, 264 Vac input Output 60950, 60601-1 60950, 60601-1 60950, 60601-1 Certificate & report Mark (LVD) Maximum power 125 W for convection (100 W for LPS202-M); 250 W (200 W for LPS202-M) with 30CFM forced air Adjustment range 10% minimum on the main outputs Fan output 12 V @ 0.5 A convection, @ 1 A forced air isolated, 10% Hold-up time 16 ms @ 250 W load, 120 Vac input Overload protection Short circuit protection on all outputs. Case overload protected @ 110 - 160% above rating Overvoltage protection 15 - 50% above nominal output Logical Control Power failure Open collector logic signal goes high 100 - 500 msec after main output; it goes low at least 6 msec before loss of regulation Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. LPS200-M Series Data Sheet Environmental Specifications Operating temperature 0 C to 50 C ambient derate each output as 2.5% per degree from 50 to 70 C. -20 C start up Storage temperature -40 C to +85 C Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating; non-condensing 10% to 95% RH Vibration IEC68-2-6 to the levels of IEC721-3-2 MTBF calculated 1 million hours at full load and 25 C ambient conditions. 230 Vac input, Bellcore Ordering Information Model Number Output Voltage Minimum Load Maximum Load with Convection Cooling Maximum Load with 30CFM Forced Air Peak Load Regulation2 Ripple P/P (PARD)3 LPS202-M 5V 0A 20 A 40 A 44 A 2% 50 mV LPS203-M 12 V 0A 10.3 A 20.8 A 22 A 2% 120 mV LPS204-M 15 V 0A 8.3 A 16.6 A 18 A 2% 150 mV LPS205-M 24 V 0A 5.2 A 10.4 A 11.5 A 2% 240 mV LPS208-M 48 V 0A 2.6 A 5.2 A 5.8 A 2% 480 mV 1. 2. 3. 4. Peak current lasting <30 seconds with a maximum 10% duty cycle. At 25 C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. Peak-to-peak with 20 mHz bandwidth and 10 F (tantalum capacitor) in parallel with a 0.1 F capacitor at rated line voltage and load ranges. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is not intended for sale to End Users. Pin Assignments Mating Connectors Connector LPS200-M SK1 Pin 1 Neutral AC Input (SK1) Molex 09-50-8031 (connector) PINS: 08-52-0072 Pin 3 Line AC Ground Molex 01-90020001 TB-1 Common TB-2 Main output DC Output (SK2) Molex 19141-0058 or 19099-0044 Spade lug based on Cable Ampacity/AWG Pin 1 +V1 Remote sense Pin 2 -V1 Remote sense Pin 3 N/C Pin 4 N/C Pin 5 +Power fail Pin 6 Common Pin 7 N/C Pin 8 Common Pin 9 +12 V Fan Pin 10 +12 Fan Return (isolated) SK2 SK3 Control Sense (SK3) Molex 90142-1110 (USA) PINS: 90119-2110 or Amp: 87977-3 PINS: 87309-8 or Landwin: 2580S1003 PINS: 2583T021V Artesyn Embedded Technologies Connector Kit #70-841-020, includes all of the above. 1. 2. 3. 4. 5. Specifications subject to change without notice. All dimensions in inches (mm), tolerance is 0.02"( 0.5 mm) Mounting holes MH1 and MH2 should be grounded for EMI purposes. Mounting hole MH1 is safety ground connection. Specifications are for convection rating at factory settings at 115 VAC input, 25 C unless otherwise stated. 6. This power supply requires mounting on metal standoffs 0.20" (5m) in height. 7. Warranty: 2 years 8. Weight: 0.75 lb/0.34 kg LPS200-M Series Data Sheet Mechanical Drawing (2.5) Max Component Lead Protrusion WORLDWIDE OFFICES Americas Europe (UK) Asia (HK) 2900 S.Diablo Way Tempe, AZ 85282 USA +1 888 412 7832 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom +44 (0) 1384 842 211 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong +852 2176 3333 Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. Specifications are subject to change without notice. (c) 2018 Artesyn Embedded Technologies, Inc. All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal. www.artesyn.com For more information: www.artesyn.com/power For support: productsupport.ep@artesyn.com LPS200-M DS 04Jan2018