T-100 (3mm)
SOLID STATE INDICATOR LAMPS
.208 (5.2)
.984 (25.0)
MIN
.039 (1.0) MIN
.100 (2.54)
.039 (1.0)
.118 (3.0)
ANODE
.149 (3.8)
FLAT
DENOTES CATHODE
.023 (0.58)
.017 (0.43)
SQ TYP. (2X)
PACKAGE DIMENSIONS
RED DIFFUSED QL202HD RED CLEAR QL202HT
HER DIFFUSED QL202ID HER CLEAR QL202IT
YELLOW DIFFUSED QL202YD YELLOW CLEAR QL202YT
GREEN DIFFUSED QL202GD GREEN CLEAR QL202GT
DESCRIPTION
These T-100 LEDs are used as general purpose indi-
cators. They come in either a wide angle (70°) dif-
fused lens or a moderate angle (32°) clear lens. The
red and green lamps are made with GaP LEDs on a GaP sub-
strate. The HER and yellow lamps are made with GaAsP LEDs on
a GaP substrate. All have an epoxy encapsulation lens.
FEATURES
• Popular T-100 package
• Choice of viewing angles
• Choice of tinted or tinted diffused lens
2001 Fairchild Semiconductor Corporation
DS300303 11/27/01 1 OF 4 www.fairchildsemi.com
NOTES:
1. Dimensions for all drawings are in inches (mm).
2. Lead spacing is measured where the leads emerge from the
package.
3. Protruded resin under the flange is 1.5 mm (0.059") max.
4. Tolerance is +/-0.12” (0.3mm) unless otherwise noted.
Part Number Symbol QL202HT QL202IT QL202GT QL202YT Condition
Luminous Intensity (mcd) IF= 10mA
Minimum IV2.5 3.5 3.0 3.5
Typical 10.0 17.0 15.0 15.0
Forward Voltage (V) IF= 10mA
Typical VF1.7 1.7 1.7 1.7
Maximum 2.1 2.0 2.1 2.0
Spectral Line Half Width (nm) ∆λ 90 45 30 35 IF= 10mA
Peak Wavelength (nm) λp 697 635 565 585 IF= 10mA
Viewing Angle (Total) (°) 2θ1/2 32 32 32 32 IF= 10mA
ELECTRICAL / OPTICAL CHARACTERISTICS (TA=25°C)
1. The leads of the device were immersed in molten solder at 260°C, to a point 1/16 inch (1.6 mm) from the body of the device per
MIL-S-750, with a dwell time of 5 seconds.
www.fairchildsemi.com 2 OF 4 11/27/01 DS300303
T-100 (3mm)
SOLID STATE INDICATOR LAMPS
Parameter Symbol Red Her Green Yellow Units
Power Dissipation PD100 100 100 100 mA
Peak Forward Current (at f = 1.0 KHz, Duty factor = 1/10) IFM 50 100 100 100 mA
Reversed Voltage VR5555V
Continuous DC Forward Current IF15 20 20 20 mA
Lead Soldering Time at 260° CT
SOL 5555sec
Operating Temperature TOPR -40 to +100 -40 to +100 -40 to +100 -40 to +100 °C
Storage Temperature TSTG -40 to +100 -40 to +100 -40 to +100 -40 to +100 °C
ABSOLUTE MAXIMUM RATING (TA=25°C)
Part Number Symbol QL202HD QL202ID QL202GD QL202YD Condition
Luminous Intensity (mcd) IF= 10mA
Minimum IV0.5 1.1 1.1 1.1
Typical 1.6 6.0 6.0 4.5
Forward Voltage (V) IF= 10mA
Typical VF1.7 1.7 1.7 1.7
Maximum 2.1 2.0 2.1 2.0
Spectral Line Half Width (nm) ∆λ 90 45 30 35 IF= 10mA
Peak Wavelength (nm) λp 697 635 565 585 IF= 10mA
Viewing Angle (Total) (°) 2θ1/2 70 70 70 70 IF= 10mA
ELECTRICAL / OPTICAL CHARACTERISTICS (TA=25°C)
RELATIVE INTENSITY (%)
Fig. 4 Relative Intensity vs. Peak Wavelength
120
40
0
20
80
100
60
520 540 560 580 600 620 640 660 680 710 730 750
GREEN YELLOW RED
90
100
IF - FORWARD CURRENT (mA)
VF - FORWARD VOLTAGE (V)
λ - WAVELENGTH (nm)
Fig. 1 Forward Current vs. Forward Voltage
40
50
60
70
80
30
20
10
01234
IF - FORWARD CURRENT (mA)
LUMNOUS INTENSITY
Fig. 2 Luminous Intensity vs. Forward Current
40
30
20
10
002040 6080
HER
HER
RED
GREEN
YELLOW
REL. LUMINOUS INTENSITY (%)
Fig. 3 Spatial Distribution
0 20406080100020406080
100 90˚
80˚
70˚
60˚
50˚
40˚
30˚
20˚
10˚
-10˚
-20˚
-30˚
-40˚
-50˚
-60˚
-70˚
-80˚
-90˚
QL202XT QL202XD
TYPICAL PERFORMANCE CURVES (TA=25°C)
DS300303 11/27/01 3 OF 4 www.fairchildsemi.com
T-100 (3mm)
SOLID STATE INDICATOR LAMPS
DISCLAIMER
FAIRCHILD SEMICONDUCTOR RESERVES THE THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE
TO ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. FAIRCHILD DOES NOT
ASSUME ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT
DESCRIBED HEREIN; NEITHER DOES IT CONVEY ANY LICENSE UNDER ITS PATENT RIGHTS, NOR THE
RIGHTS OF OTHERS.
LIFE SUPPORT POLICY
FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD
SEMICONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or
systems which, (a) are intended for surgical
implant into the body,or (b) support or sustain life,
and (c) whose failure to perform when properly
used in accordance with instructions for use provided
in labeling, can be reasonably expected to result in a
significant injury of the user.
2. A critical component in any component of a life support
device or system whose failure to perform can be
reasonably expected to cause the failure of the life
support device or system, or to affect its safety or
effectiveness.
www.fairchildsemi.com 4 OF 4 11/27/01 DS300303
T-100 (3mm)
SOLID STATE INDICATOR LAMPS