TEMPERATURE SWITCH IC (THERMOSTAT IC)
S-5844A Series Rev.2.1_00
Seiko Instruments In c. 4
3. Product list
3. 1 SOT-23-5
Table 2
Product Name Detection
Temperature
(TDET) DET Pin Output Form DET Pin Output
Logic
Hysteresis
Temperature
(THYS)
S-5844A55CB-M5T1U3 +55°C Nch open drain Active "H" 10°C
S-5844A55CC-M5T1U3 +55°C Nch open drain Active "H" 15°C
S-5844A55CD-M5T1U3 +55°C Nch open drain Active "H" 20°C
S-5844A55DB-M5T1U3 +55°C Nch open drain Active "L" 10°C
S-5844A60CB-M5T1U3 +60°C Nch open drain Active "H" 10°C
S-5844A60CC-M5T1U3 +60°C Nch open drain Active "H" 15°C
S-5844A60CD-M5T1U3 +60°C Nch open drain Active "H" 20°C
S-5844A60DB-M5T1U3 +60°C Nch open drain Active "L" 10°C
S-5844A65CB-M5T1U3 +65°C Nch open drain Active "H" 10°C
S-5844A65CC-M5T1U3 +65°C Nch open drain Active "H" 15°C
S-5844A65CD-M5T1U3 +65°C Nch open drain Active "H" 20°C
S-5844A65DB-M5T1U3 +65°C Nch open drain Active "L" 10°C
S-5844A70CB-M5T1U3 +70°C Nch open drain Active "H" 10°C
S-5844A70CC-M5T1U3 +70°C Nch open drain Active "H" 15°C
S-5844A70CD-M5T1U3 +70°C Nch open drain Active "H" 20°C
S-5844A70DB-M5T1U3 +70°C Nch open drain Active "L" 10°C
S-5844A75CB-M5T1U3 +75°C Nch open drain Active "H" 10°C
S-5844A75CC-M5T1U3 +75°C Nch open drain Active "H" 15°C
S-5844A75CD-M5T1U3 +75°C Nch open drain Active "H" 20°C
S-5844A75DB-M5T1U3 +75°C Nch open drain Active "L" 10°C
S-5844A80CB-M5T1U3 +80°C Nch open drain Active "H" 10°C
S-5844A80CC-M5T1U3 +80°C Nch open drain Active "H" 15°C
S-5844A80CD-M5T1U3 +80°C Nch open drain Active "H" 20°C
S-5844A80DB-M5T1U3 +80°C Nch open drain Active "L" 10°C
S-5844A85CB-M5T1U3 +85°C Nch open drain Active "H" 10°C
S-5844A85CC-M5T1U3 +85°C Nch open drain Active "H" 15°C
S-5844A85CD-M5T1U3 +85°C Nch open drain Active "H" 20°C
S-5844A85DB-M5T1U3 +85°C Nch open drain Active "L" 10°C
S-5844A90CB-M5T1U3 +90°C Nch open drain Active "H" 10°C
S-5844A90CC-M5T1U3 +90°C Nch open drain Active "H" 15°C
S-5844A90CD-M5T1U3 +90°C Nch open drain Active "H" 20°C
S-5844A90DB-M5T1U3 +90°C Nch open drain Active "L" 10°C
S-5844A95CB-M5T1U3 +95°C Nch open drain Active "H" 10°C
S-5844A95CC-M5T1U3 +95°C Nch open drain Active "H" 15°C
S-5844A95CD-M5T1U3 +95°C Nch open drain Active "H" 20°C
S-5844A95DB-M5T1U3 +95°C Nch open drain Active "L" 10°C
Remark Please contact our sales office for products with specificat ions other than the above.