Ordering information High-voltage pulses high-attenuation type NAP series NAP -10 -472 1 2 3 -O 4 1 Model Name 2 Rated Current 3 Line to ground capacitor code:See table 1.1. R table1.1 Line to ground capacitor code Code The terminal cover is retracted inside the unit DIN rail installation type is option 000 101 221 331 471 681 102 222 332 472 Line to ground Leakage Current capacitor (Input 125/250V 60Hz) (nominal value) 5 A/ 10 A max Not Provided 12.5 A/ 25 A max 100pF 25 A/ 50 A max 220pF 37.5 A/ 75 A max 330pF 50 A/100 A max 470pF 75.5 A/150 A max 680pF 0.13mA/0.25mA max 1000pF 0.25mA/0.5 mA max 2200pF 3300pF 0.38mA/0.75mA max 0.5 mA/1.0 mA max 4700pF When the line to ground capacitor code is different, the attenuation characteristic is different. * 4 Options D :DIN rail installation type * The dimensions change when the option is set. Refer to External view. Features of NAP series High-voltage pulses high-attenuation type - Single Phase 250 VAC - Push down type terminal block Specifications No. 1 Items NAP-04-472 Rated Voltage[V] AC 1f 250 / DC250 NAP-06-472 NAP-10-472 NAP-16-472 NAP-20-472 NAP-30-472 10 16 20 30 2 Rated Current[A] 4 3 Test Voltage (Terminal-Mounting Plate) 2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity 6 4 Isolation Resistance (Terminal-Mounting Plate) 500 VDC 100MW min at room temperature and humidity 5 Leakage current 125/250V 60Hz 0.5mA/1.0mA max 6 Voltage drop 1.0V max 7 Safety agency approval temperatures -25 to +85C (Refer to Derating Curve) 8 Operating temperature -40 to +85C (Refer to Derating Curve) 9 Operating humidity 20 to 95%RH (Non condensing) 10 Storage temperature/humidity -40 to +85C/20 to 95%RH (Non condensing) 11 Vibration 10 to 55Hz, 19.6m/s2 (2G), 3min. Period, 1hour each X, Y and Z axis 12 Impact 196.1m/s2 (20G), 11ms Once each X, Y and Z axis 13 Safety agency approvals UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input) 14 Case size (without projection) /Weight 53X41X92 mm [2.09X1.61X3.62 inches] (WXHXD) /300g max (Option : -D refer to external view) Circuit Diagram Derating Curve Case 1 CY LINE CY 2 3 LOAD 4 Load Factor [%] 100 80 60 40 20 0 -40 CY : Line to ground capacitor : Mounting Plate -30 -20 40 50 55 60 70 80 90 Ambient Temperature [C] NA-4 NAH,NAC,NAM,NAP series External view As this product is adopted push-down type terminal block, this appearance is as follows. 1The terminal cover is retracted inside the unit. 2The screws for connecting the terminals are held in the up right position. Standard Type 92 [3.62] (2.5) 82 0.5 [3.23] 2-f4.8 77 [0.19] Mounting Hole 27 [1.06] [0.1] 2-Protection Earth 8 [0.31] [3.03] [0.47] 53 [2.09] [1.77] 45 0.5 Output Terminal Name Plate [0.59] Output Terminal 12 15 Input Terminal Input Terminal 6-M4 Mounting Plate (2) Closed the terminal cover [0.08] Terminal cover Terminal cover Tolerance : 1 [0.04] Weight : 300g max 41 [1.61] Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 [0.04] Case : PBT Dimensions in mm, [ ]=inches Terminal block screw tighting torque M4:1.6N-m (16.9kgf-cm) max DIN rail installation Type 92 (11) [3.62] [0.43] 77 [3.03] (2.5) 2-Protection Earth 27 [0.1] [1.06] 8 [0.31] [2.09] [0.47] 53 Output Terminal Name Plate [0.59] 12 Output Terminal Input Terminal 6-M4 Terminal cover Mounting Plate (2) Terminal cover Closed the terminal cover [0.08] 15 Input Terminal 41 [1.61] Tolerance : 1 [0.04] Weight : 300g max Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 [0.04] Dimensions in mm, [ [0.35] 7 DIN rail Note when installing the EMI/EMC Filter on a DIN rail. When the EMI/EMC Filter is grounded through the DIN rail, the proper noise attenuation may not be achieved. Be sure to connect the protection earth (PE) of the EMI/EMC Filter body to the earth. It can connect the ground to either one only. NA-5 ]=inches Terminal block screw tighting torque M4:1.6N-m (16.9kgf-cm) max [0.28] (9) Case : PBT DIN rail Name Plate