QPL Active Delay Lines (TTL)
nActive 5 tap, 14-pin DIP delay lines qualified to MIL-D-83532.
nEstablished reliability assured through a fully approved program in
accordance with MIL-STD-790.*
nStandard total delay values ranging from 25 to 500 ns and tap delay
values from 5 to 100 ns.
nOther military part numbers with non-standard delay values
available upon request.
nQPL JAN I.C.’s (in accordance with MIL-M-38510) incorporated
in all active delay lines.
nAll units transfer molded for maximum reliability.
nPulse Specialty Components - the first delay line supplier to be QPL’d.
*Reliability Assurance Program for Electronic Parts Specifications
TWO PEARL BUCK COURT
l
BRISTOL, PA 19007-6812
l
TEL 215-781-6400
l
FAX 215-781-6403
l
www.pulsespecialty.com
MILITARY
PART NO. TECHNITROL
P ART NO . T A P DEL AYS (n s ) TRR+*
T
DD
1 T
DD
2 T
DD
3 T
DD
4 T
DD
5
M83532/02A001A TTLDL0257JY 5.0 10.0 15.0 20.0 25.0 4.0
M83532/02A006A TTLDL0507JY 10.0 20.0 30.0 40.0 50.0 4.0
M83532/02A011A TTLDL0757JY 15.0 30.0 45.0 60.0 75.0 4.0
M83532/02A014A TTLDL1007JY 20.0 40.0 60.0 80.0 100.0 4.0
M83532/02A015A TTLDL1257JY 25.0 50.0 75.0 100.0 125.0 4.0
M83532/02A016A TTLDL1507JY 30.0 60.0 90.0 120.0 150.0 4.0
M83532/02A018A TTLDL2007JY 40.0 80.0 120.0 160.0 200.0 4.0
M83532/02A020A TTLDL2507JY 50.0 100.0 150.0 200.0 250.0 4.0
M83532/02A026A TTLDL5007JY 100.0 200.0 300.0 400.0 500.0 5.0
ACTIVE MIL-D-83532 QPL DEL AY LINES (TTL LOGIC)
NOTE: Additional slash numbers from 02A001A through 02A029A available upon request.
*Measured @ Vcc = 5.0V, 25oC, with 50pf load to ground and 500 ohms to Vcc
First QPL’d
delay lines.