NV175 Series 3" x 5" 175-200W Power Supplies Features 1-5 Outputs Up to 90% Efficient Active Power Factor Correction Universal Input (90 - 264VAC) No Minimum Loads Medical Approvals (Basic Insulation Input-Output) Key Market Segments & Applications Specifications Model Input Voltage range Inrush Current Power Factor Harmonics Regulation Total Ripple & Noise Efficiency Minimum Load Overcurrent Protection Overvoltage Protection Overtemperature Protection Hold Up Time (Typ) Leakage Current (max) Remote Sense DC Good Remote On/Off (Specify N option) Operating Temperature (1)(7) Storage Temperature Humidity (non condensing) Cooling Isolation (4) Vibration (non operating) Shock Safety Agency Approvals Immunity Conducted Emissions and Flicker Radiated Emissions (2) Weight (Typ) Size (without cover) (3) Warranty A mV A V ms A g in yrs NV175 90 - 264VAC (47 - 63Hz, 440Hz with reduced PFC) <40A at 25C and 264VAC input, Cold Start EN61000-3-2 Compliant (0.97 typical) 1%; Including Line (for 90-264VAC input change), Load (for 0-100% load change) and Cross (for 0-100% load change on any other output) regulation 1% or 50mV (Which ever is greater) Up to 90%, configuration dependant None >105% CH1 & CH2, 120-130%, Cycle AC line to reset Yes >16ms at 90VAC Input 123A 120VAC 60Hz, 257A 240VAC 60Hz, <300A 264VAC 63Hz (Type Test results) On Outputs CH1 & CH2, 0.5V compensation maximum CH1 Only, High on Fail (90% of nominal 5%) -N1 or -N2 option: TTL level high = Off, -N3 or -N4 option: open circuit = Off (except standby) 0 to +70C. Derate linearily to 50% load from 50C to 70C -40 to +85C 5 - 95% RH Forced air, 2m/s from input to output (Approx 10 CFM) Input to Ground 2.3kVDC, Input to Output 4.3kVDC, Output to Ground 200VDC Conforms to MIL-STD-810E, Method 516.5, Pro I, IV, VI; EN60068-2-6, IEC68-2-6 Conforms to MIL-STD-810E/F, Method 514.4, Pro I, Cat 1,9; EN60068-2-27, EN60068-2-47, IEC68-2-47, IEC68-2-47, JIS C0041-1987 UL/CSA/IEC/EN 60950-1, UL/CSA/IEC/EN 60601-1, ANSI/AAMI ES60601-1, IEC/EN 61010-1, CE Mark EN61000-6-2:2001, EN61000-4-2, -3, -4, -5, -6, -8, -11 EN55022 Class B (per CISPR.22), EN61000-3-3 EN55022 Class A (per CISPR.22) 250g 3" x 5" x 1.25"; N option version 3.7" x 5" x 1.25" Three Years (1) -20C cold start (2) See application note for Class B (3) Including underside component leads (4) Input-Output: Reinforced IEC60950-1, Basic IEC 60601-1. See NV175-M for reinforced medical insulation 1-800-526-2324 * www.us.tdk-lambda.com/lp/ 81 Disclaimer: us.tdk-lambda.com/lp/legal.htm NV175 Series Stocked Models Quick Selector Outline Drawing CH5 Global CH1 CH2 CH3 CH4 Stand By Option Model (5) (5) (6) Type NV1-1T000 12V/15A NV1-1G000 24V/7.5A NV1-453TT +5V/25A +3.3V/15A +12V/5A -12V/1A NV1-453FF +5V/25A +3.3V/15A +15V/5A -15V/1A NV1-4G5TT +24V/7.5A +5V/8A +12V/5A -12V/1A NV1-4G5FF +24V/7.5A +5V/8A +15V/5A -15V/1A NV1-453TT-N3 +5V/25A +3.3V/15A +12V/5A -12V/1A 5V/2A N3 (ATX) NV1-453FF-N3 +5V/25A +3.3V/15A +15V/5A -15V/1A 5V/2A N3 (ATX) NV1-4G5TT-N3 +24V/7.5A +5V/8A +12V/5A -12V/1A 5V/2A N3 (ATX) NV1-4G5FF-N3 +24V/7.5A +5V/8A +15V/5A -15V/1A 5V/2A N3 (ATX) Notes: (5) Maximum combined current from CH1 + CH2 = 25A 5V CH1 models are limited to 175W max. All others 180W, 200Wpk 5 mins (6) CH5 is always on regardless of inhbit status. Peak rated at 2.5A, floating output (7) Convection cooled maximum ratings: CH1: 55W, Ch2: 8.25W, Ch3: 9W, CH4: 3W, 75.25W total. 0C - 40C temperature range (8) 12 - 12.5V if 24V CH3 is fitted. (9) 14.5 - 15.5V if 24V CH3 is fitted. (10) 24 - 24.5V if 5V CH2 is fitted. 24 - 26V if 24V CH3 is fitted See the website for detailed datasheet and outline drawing. Built to Order Model Selector CH1 +5V / 25A +12V / 15A +15V / 12A +24V / 7.5A CH1(5) Code 5 T F G Adjust. Range 5 - 5.5V CH2(5) +1.8V / 15A +2.7V / 15A +3.3V / 15A No output CH2 Code 1 2 3 0 12 - 15V (8) +5V / 10A 12 - 15V (9) No output Adjust. Range 0.9 - 3.3V 2.5 - 3.3V 2.5 - 3.3V - 5 0 24 - 28V (10) +5V / 8A No output 3.3 - 5.5V - 5 0 3.3 - 5.5V - CH3 CH3 Code Adjust. Range +12V / 5A +15V / 5A +24V / 2.5A No output T F G 0 12 - 15V 12 - 15V 18 - 24V - Add "Y" to code for negative polarity output CH4 -12V / 1A -15V / 1A -3.3V / 2A -5V / 2A -12V / 2A -15V / 2A Fan Supply only No output CH4 Code T F 3H 5H TH FH 0H 0 Add "P" to code for positive polarity output Add "P" to code for positive polarity output Adjust. Range Fixed Fixed Fixed Fixed Fixed Fixed Fixed How to Create a Model Number NV1- Enter number of outputs CH1 Code CH2 Code CH3 Code CH4 Code No Option AC Fail, Remote On/Off, 5V/2A Standby, CH1 DC Good AC Fail, Remote On/Off, 12V/1A Standby, CH1 DC Good AC Fail, Remote On/Off, 13.5V/1A Standby, CH1 DC Good ATX AC Fail+Remote On/Off, 5V/2A Standby, CH1 DC Good ATX AC Fail+Remote On/Off, 12V/1A Standby, CH1 DC Good Global Option Case Option Blank N N1 N2 N3 N4 Blank U C F I No Case U Chassis U Chassis with Cover U Chassis, Cover and Fan* U Chassis, Cover and Fan* and IEC inlet * A high output CH4 (3H, 5H, TH, FH) or fan supply 0H must be selected to provide fan option. Example NV1 3 G 5 0 3HP N C Description: Triple output, 24V/7.5A, 5V/8A, 3.3V/2A, Global option N, U Chassis with cover. Mating Parts (Molex) Other Industrial Products CONN J1 J2 NV SC40/60 ZWS/ZWSPAF Housing 39-01-2245 09-50-8051 Pins 44476-3112 08-52-0113 300 to 700W Medical, 1-6 outputs 40 to 80W single, dual & triple 3x5 footprint 5 to 240W single output power supplies For Additional Information, please visit us.tdk-lambda.com/lp/products/nv-series.htm 1-800-526-2324 * www.us.tdk-lambda.com/lp/ 82 Revision C9: Jul 2014 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TDK-Lambda: NV1350FF NV1350FFNC NV1350TT NV1452FF NV1452FFC NV1452FFN NV1452TTC NV1452TTN NV1452TTNC NV1453TTC NV1453TTN3 NV1453TTNC NV14G5FF NV14G5FFN3 NV14G5TTN3 NV1453FFN NV11T000 NV11G000 NV1453FFN3 NV1250T0N NV1350TTC NV11G000HF NV11T000HF NV14G5TTHF NV14G5FFHF NV11G000HN3F NV1250T0HF NV1-453GFHP NV1-3G5T0