PolySwitch® Resettable PPTCs
© 2019 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 01/31/19
Radial Leaded > AGRF Series
AGRF Series RoHS
Description
The AGRF Series is a PPTC resettable device designed
specifically for the automotive industry. It is a 16V
lead-free, radial leaded resettable device that meets
Littelfuse’s Automotive qualification. This qualification
is based on AEC-Q200: Stress Test Qualification for
Passive Components.
Applications
• Motor and motor circuit protection including power door-
locks, mirrors, lumbar umps, seats, sunroofs and windows
• Electronic Control Unit (ECU) I/O protection
• Heating, Ventilation and Cooling (HVAC) motor and
I/O protection
• Telematics, infotainment and navigations systems
• Liquid Crystal Display (LCD) back-light heaters
• Power and cigarette lighter outlets, plugs and adapter/chargers
• Powered networks and buses
• Air-flow detection and overcurrent protection in HVAC
and cooling fan systems
• Stall detection in express window and sunroof circuits
• Resettable overcurrent protection for power distribution,
electrical centers and junction boxes
• Wire downsizing
• Motor electromagnetic interference (EMI) suppression
• Electrostatic discharge (ESD) damage protection
• Load dump and other transient voltage protection
Features
• Overcurrent and overvoltage circuit protection devices
• Resettable and single-use overcurrent devices
• Wide range of form factor and termination methods
• Products meet applicable automotive industry standards
• Devices compatible with high-volume electronics
assembly
• RoHS compliant, Lead-Free and Halogen-Free
Electrical Characteristics
Part
Number
IH(A)@ IH(A)@ ITVMAX IMAX PD Typ Max Time-to-trip RMIN RMAX R1MAX Lead Size
(mm2/AWG)
(R1MAX) (RaMAX) (A) (VDC) (A) (W) (A) (s) (Ω) (Ω) (Ω)
AGRF – 16V
AGRF400 4.0 3.0 7. 6 16 100 2.5 20.0 2.0 0.0186 0.0610 0.0850 0.52/20
AGRF500 5.0 4.3 9.4 16 100 2.7 25.0 2.5 0.0140 0.0340 0.0480 0.52/20
AGRF600 6.0 5.3 10.7 16 100 2.8 30.0 3.5 0.0095 0.0280 0.0320 0.52/20
AGRF700 7. 0 6.5 13.2 16 100 3.0 35.0 4.0 0.0066 0.0200 0.0220 0.52/20
AGRF800 8.0 7. 6 15.0 16 10 0 3.2 40.0 5.5 0.0049 0.0175 0.0181 0.52/20
AGRF900 9.0 8.6 16.5 16 100 3.4 45.0 6.0 0.0041 0.0135 0.0140 0.52/20
AGRF1000 10.0 9.6 18.5 16 100 3.6 50.0 7. 0 0.0034 0.0102 0.0106 0.52/20
AGRF1100 11. 0 10.5 20.3 16 10 0 3.7 55.0 7. 5 0.0033 0.0089 0.0093 0.52/20
AGRF1200 12.0 11. 5 22.1 16 100 4.2 60.0 8.0 0.0030 0.0086 0.0091 0.82/18
AGRF1400 14.0 13.0 27.3 16 100 4.6 70.0 9.0 0.0022 0.0064 0.0067 0.82/18
Notes:
IH : Hold current: maximum current device will pass without interruption in 25°C,
unless otherwise specified.
IT : Trip current: minimum current that will switch the device from low-resistance to
high-resistance in 25°C still air, unless otherwise specified.
VMAX : Maximum voltage device can withstand without damage at rated current.
IMAX : Maximum fault current device can withstand without damage at rated voltage.
PD : Power dissipated from device when in the tripped state in 25°C still air,
unless otherwise specified.
RMIN : Minimum resistance of device as supplied at 25°C, unless otherwise specified.
R1MAX : Maximum resistance of device when measured one hour post trip at 25°C unless
otherwise specified.
RaMAX : Maximum functional resistance of device after being subjected to the stresses
described in PS400 at 25°C, unless otherwise specified.
RaMIN :
Minimum functional resistance of device after being subjected to the stresses
described in PS400 at 25°C, unless otherwise specified.
* Electrical characteristics determined at 25°C.
Additional Information
Datasheet Resources Samples