TO REF. No. APPROVED CHECKED _ | PREPARED DATE sam, ERD [BERN FER Tat 23, By MODEL No, XB4805HX-K90 ps, (YS) DESCRIPTION: DC_FAN (RoHS) REV... ID No. THIS OFFER IS MADE ACCORDING TO YOUR CURRENT INQUIRY. UNLESS OTHERWISE REVISED, THIS SPECIFICATION WILL BE FINAL FOR ALL FUTURE PRODUCTION OF ORDERS FROM YOUR RESPECTED COMPANY KINDLY STUDY IN DETAILS AND RETURN TO US THE DUPLICATE DULY SIGNED AS YOUR CONFIRMATION OF SAME. aa UKAS ERANAGEMENT. ADDA CORP, 005 REGISTERED TG 150 9001 ISO/TS 16949 GERTIFICATE NO.A8035 SESE TSB ar a eer re ee mann PSR UP anes toe DATA-SHEET Engineering BRUSHLESS AXIAL COOLING FANS. Printed on: 07/11/21 RATED CURRENT RATED POWER RATED SPEED AIR FLOW STATIC AIR PRESSURE NOISE LEVEL MOTOR PROTECTION CONNECTION LEAD TYPE _ LIFE EXPECTANCY NET WEIGHT PACKING temperature is 25C for the specified in the acknowledge Customer Ref: (ROHS) ADDA Model No. >: AD4505HxX-K90 P.S:(5) Samples attached piece(s) Safety Approval : CE Specifications TTEM SPECIFICATION / CONDITION DIMENSIONS a5x45x06 MM BEARING TYPE HYPRO RATED VOLTAGE 5.0 VDC OPERATING VOLTAGE RANGE 4.5 vpc - 5,5 vbc START-UP VOLTAGE 4.0 VBC, NOMINAL 0.140 Amp. + 10% MAX 0.70 Watt. 6000 RPM + 10% (IN FREE AER AT RATED VOLTAGE) 9.2 CFM (IN FREE AIR AT RATED VOLTAGE) 0.103 Inch water CIN FREE AIR AT RATED VOLTAGE) 32.6 dB/A BY IMPEDANCE WIRE ,AWG#28 50000 Hours at 25C / 65% 24 Gram. 560 pcs. per Export Carton Unless otherwise stated, the relative humidity is 65%, and the | standard testing. Should you have any doubt,please refer to the environmental cond? ment document, fats eet foe we eS foo AE be) TR Mu 1, 26 >> bE >>> YE a Kees 1 mtr, -> ADDA CORPORATION Model No.: AD4505HX-K90 P.S:(Y5) | Page 2/4 SPECIFICATION 5.0 MECHANICAL INSPECTION 5.1 Rotation Direction Counterclockwise when look into impeller side. 5.2 Protection All fans have integrated protection against locked rotor condition so that there will be no damage to winding or any electronic component. Restarting is automatic as soon as any constraint to rotation has been released. As fan placed at dead angle position, and the switch was changed from off to on. Restarting was automatic normal as soon as and proved that this fan ts good fan. 5.3 Locked Rotor Protection No damage shall be found after 72 hours continuously at condition of rotation locked. Restarting is automatic as soon as constraint to running has been released. 5.4 Avoid the damage, check the correct voltage and proper polarity before connecting with power. 5.5 Free Drop Shock In minimum package condition, the fan should withstand drops on any three faces from a height of 30cm onto a wood board of 10mm thick. 5.6 Please do not stick a grease and/or an oil to the fan housing or blade which may have a harmful inftuence by a chemical reaction at high humidity. 5.7 lf the fan is reinstalled, please pay special attention to the noise due to the vibration (or resonance). 5.8 During the testing of the fan, please make sure the finger guard is used for safety. 6.0 ELECTRICAL INSPECTION 6.1 Insulation Resistance Noi less than 10M ohm between housing and positive end of lead wire (red) at 500V DC. 6.2 Dielectric Strength No damage should be found at 500 VAC for 60 seconds, measured with 1mA trip current between housing and positive end of lead wire. 6.3 Life Expectancy The continous duty life ai given temperature after which, 90% of testing units shall still be running. 6.4 While the fan is running, do not intentionally lock the fan for a iong time since the overheating of the motor produced by the long-time !ocking will damage the fan. 7.0 ENVIRONMENTAL 7.1 improper use such as disassembling the fan, being covered with dust, or dipping the fan in water that results in defects is not covered in the warranty. Do not use the fan in the environment with corrosive air or liquid. 7.2 Operating Temperature / Humidity -10C to +70C at humidity 65%+/-20% RH. 7.3 Storage Temperature All function shall be normal after 500 hours storage at -40C to +70 C with a 24 hour recovery period at room temperature. 7.4 Humidity After 96 hours, 95% RH, 40+/-2C per MIL-STD-202F, method 103B humidity test, the months, the fan may have the electric current leakage. ADDA CORPORATION Model No. : AD4505HX-K90__P.S:(Y5) Page 3/4 SPECIFICATION 8.0 REMARKS 8.1 Material and construction are subject to change without advance notice. The changes should be within specification. 8.2 All fans shall meet the quality inspection under sampling plan MIL-STD-105E as follow: Critical 0.25% Major 1.00% Minor 2.50% 9.0 OUTLINE STYLING & DIMENSIONS 46.8209 4020.3 pee 0.o | O+0 40.4+0.3 LEAD WIRES: UL 1571, AWG28, L=135 +/- 10 MM Red = positive; Black = negative. 10.0 Notes: 10.1 Please do not touch and push Fan Blade with fingers or others, fan blade and hypro bearings may be damaged and it causes noise defect. 10.2 Do not carry the fan by its lead wires. 10.31f the fan does not have the polarity protection function, the connection of the colored wires should bered +red, and black + black, or else the Japawit be damaged in no time. 10.4 For the models without reverse connection of polarity protect connect the lead wire in reverse fe - isto not ADDA CORPORATION Model No. : AD4505HX-K90_P.S:(5) | Page 4/4