ACDC 60 Watts SDS Series xppower.com * Single, Dual, Triple & Quad Outputs * Output Voltages from 3.3 V to 48 V * Nonstandard Outputs Available * Industry Standard 3" x 5" Package * Fits 1U Applications * Open Frame, U Channel & Covered Versions * 3 Year Warranty Specification Input * 90-264 VAC (120-370 VDC) * 47-63 Hz * 1.6 A max at 115 VAC 1.0 A max at 230 VAC Inrush Current * <15 A at 115 VAC, cold start at 25 C <30 A at 230 VAC, cold start at 25 C Earth Leakage Current * <0.30 mA at 115 VAC <0.75 mA at 240 VAC Power Factor * EN61000-3-2, Class A Input Protection * T2 A/250 VAC internal fuse in line Input Voltage Input Frequency Input Current Output * See table * 10% on V1 only (see note 4) * Single output models: 1% Multi-output models: 5% Minimum Load * 10% required on V1 & V2 of multi-output models to maintain regulation, unit will start up with no load Start Up Delay * 2 s typical Hold Up Time * 12 ms min at 110 VAC, 100% load Line Regulation * 1% from low line to high line Load Regulation * 7% max all models 3% typical, see table 10% with no load on V1, for multi output models Transient Response * 4% max deviation, recovery to within 1% in 4 ms for a 50% load change Ripple & Noise * 1% pk-pk typical, 20 MHz bandwidth Overvoltage Protection * 112-132% of nominal output voltage on V1 only, recycle input to reset Overload Protection * 110-150% of nominal power, with auto recovery Short Circuit Protection * Trip & restart (hiccup mode), auto recovery Temperature * 0.04%/C Coefficient Output Voltage Output Voltage Trim Initial Set Accuracy General Efficiency Isolation Switching Frequency Power Density Signals MTBF * 80% typical, 230 VAC full load * 3000 VAC Input to Output 1500 VAC Input to Ground 500 VDC Output to Ground * 60 kHz typical * 3.5 W/In3 * Green DC OK LED * 190 kHrs typical to MIL-HDBK-217F at 25 C, GB Environmental Operating Temperature * 0 C to +70 C, derate linearly from 100% load at +50 C to 50% load at +70 C Cooling * Convection-cooled Operating Humidity * 5-95% RH, non-condensing Storage Temperature * -40 C to +85 C EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity * * * * Radiated Immunity EFT/Burst Surge * * * Conducted Immunity Magnetic Field Dips & Interruptions * * * Safety Approvals * EN55022, level B conducted and radiated EN61000-3-2, Class A EN61000-3-3 EN61000-4-2, level 2 contact, level 3 air, Perf Criteria A EN61000-4-3, level 2, Perf Criteria A EN61000-4-4, level 2, Perf Criteria A EN61000-4-5, installation Class 3, Perf Criteria A EN61000-4-6, level 2, Perf Criteria A EN61000-4-8, 1 A/m, Perf Criteria A EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B EN60950-1, UL60950-1, CSA60950-1 per cUL Output Power Output Voltage 50 W 55 W 60 W 63 W 63 W 63 W 63 W 63 W 63 W 63 W 63 W 3.3 5.0 7.0 9.0 12.0 15.0 19.0 24.0 30.0 36.0 48.0 Output Current V V V V V V V V V V V 15.1 11.0 8.6 7.0 5.2 4.2 3.3 2.6 2.1 1.7 1.3 A A A A A A A A A A A Factory-Set Voltage Range(1) 3.0-5.0 5.0-6.0 6.0-8.0 8.0-11.0 11.0-13.0 13.0-16.0 16.0-21.0 21.0-27.0 27.0-33.0 33.0-40.0 40.0-50.0 VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC Output V2(2,3,4) Current Range 16.6-10.0 11.0-9.1 10.0-7.5 7.8-5.7 5.7-4.8 4.8-3.9 3.9-3.0 3.0-2.3 2.3-1.9 1.9-1.5 1.5-1.2 A A A A A A A A A A A Output Power Output V1(2,3,4) Output V3(3) 63.0 W 48.1 W +5.0 V/7.0 A +3.3 V/7.0 A +12.0 V/3.0 A +5.0 V/5.0 A 63.0 63.0 63.0 53.5 53.5 63.0 63.0 63.0 63.0 63.0 63.0 W W W W W W W W W W W +3.3 +3.3 +3.3 +3.3 +3.3 +5.0 +5.0 +5.0 +5.0 +5.0 +5.0 V/6.0 V/6.0 V/6.0 V/5.0 V/5.0 V/6.0 V/6.0 V/6.0 V/6.0 V/6.0 V/6.0 A A A A A A A A A A A +12.0 +12.0 +12.0 +5.0 +5.0 +12.0 +12.0 +15.0 +24.0 +24.0 +24.0 V/3.0 V/3.0 V/3.0 V/5.0 V/5.0 V/3.0 V/3.0 V/3.0 V/2.0 V/2.0 V/2.0 A A A A A A A A A A A -12.0 -5.0 +5.0 +12.0 -12.0 -12.0 -5.0 -15.0 -24.0 -12.0 +12.0 V/0.8 V/0.8 V/0.8 V/1.0 V/1.0 V/0.8 V/0.8 V/0.8 V/0.5 V/0.8 V/0.8 A A A A A A A A A A A 63.0 63.0 63.0 63.0 63.0 63.0 59.3 W W W W W W W +3.3 +3.3 +5.0 +5.0 +5.0 +5.0 +5.0 V/6.0 V/6.0 V/6.0 V/6.0 V/6.0 V/6.0 V/6.0 A A A A A A A +12.0 +12.0 +12.0 +12.0 +12.0 +15.0 +24.0 V/3.0 V/3.0 V/3.0 V/3.0 V/3.0 V/3.0 V/1.8 A A A A A A A -12.0 -12.0 -12.0 -12.0 -12.0 -15.0 -15.0 V/0.8 V/0.8 V/0.8 V/0.8 V/0.8 V/0.8 V/0.1 A A A A A A A Total Regulation Model Number(5,6) 5% 5% 4% 3% 3% 3% 3% 2% 2% 2% 2% SDS60US03 SDS60US05 SDS60US07 SDS60US09 SDS60US12 SDS60US15 SDS60US19 SDS60US24 SDS60US30 SDS60US36 SDS60US48 Output V4(3) Model Number(5,6) SDS60UD01 SDS60UD04 SDS60UT00 SDS60UT01 SDS60UT02 SDS60UT03 SDS60UT04 SDS60UT05 SDS60UT06 SDS60UT07 SDS60UT08 SDS60UT09 SDS60UT10 -5.0 +5.0 -5.0 +24.0 -24.0 -5.0 +12.0 V/0.8 V/0.8 V/0.8 V/0.8 V/0.8 V/0.8 V/0.8 A A A A A A A SDS60UQ00 SDS60UQ01 SDS60UQ02 SDS60UQ03 SDS60UQ04 SDS60UQ05 SDS60UQ06 Notes 1. If an output voltage within the factory-set voltage range is required, a model number will be allocated at the time of order. 2. 10% minimum load required on V1 & V2 of multi-output units to maintain regulation of 5%. Regulation increases to 10% with no load. 3. Other output combinations are available - contact sales for more information. 4. On multi-output units V2 tracks V1, if V1 is adjusted by 5%, V2 changes by 5%. 5. For optional U-bracket, add suffix `B' to model number. 6. For optional 2 pin AC input, contact sales for details. 7. To receive unit with cover fitted, add suffix `-C' to model number. Mechanical Details 0.16 (4.0) DIA MOUNTING HOLE (4PL.) 0.22 (5.6) ADJ DC OK LED 1 6 (multi output only) 7 8 L 2.55 (64.8) 3.00 (76.2) P2 DC OUTPUT AC INPUT P1 Pin 1 2 3 4 5 6 7 8 Single Output Output 1 Output 1 Output 1 Return Return Return PIN CONNECTIONS Dual Output Triple Output Output 2 Output 2 Output 1 Output 1 Output 1 Output 1 Common Common Common Common N/C Output 3 Quad Output Output 2 Output 1 Output 1 Common Common Output 3 Output 4 Output 4 N Notes G 1. All dimensions are in inches (mm) 2. Weight: 0.52 lbs (240 g) approx 3. Tolerance: 0.02 (0.5) 4. Input connector mates with Molex housing 09-50-3051 and Molex 2878 series crimp terminal. 5. Output connector mates with Molex housing 09-50-3061 or 9-50-3081 and Molex 2878 series crimp terminal. 6. For optional cover kit order part number SDS60 COVER KIT, to receive unit with cover fitted add suffix `-C' to model number. Cover size: 5.46 x 3.55 x 1.55 (140 x 91 x 39.7mm). 7. For mating connectors and cable harness order part numbers: SDS60 CON KIT - Single, dual and triple output models SDS60Q CON KIT - Quad output models SDS60 LOOM KIT - Single output models cable harness SDS60DT LOOM KT - Dual and triple output models cable harness SDS60Q LOOM KIT - Quad output models cable harness 0.22 (5.6) 1.20 (30.5) 4.56 (115.8) 5.00 (127.0) 0.12 (3.0) max 21-Jan-11 ACDC SDS60 Models and Ratings