2
SCD8609 Rev E 9/9/11 Aeroflex Plainview
ABSOLUTE MAXIMUM RATINGS
PARAMETER RANGE UNITS
Operating (Junction) Temperature Range -55 to +150 C
Lead Temperature (soldering, 10 sec) 300 °C
Storage Temperature Range -65 to +150 C
Input-Output Voltage Differential 30 (Neg) V
Thermal Resistance (junction to case JC) each, Pos. & Neg. 5°C/W
ESD Rating 1.999 1/ KV
1/ Meets ESD testing per MIL-STD-883, method 3015, Class 1C.
NOTICE: Stresses above those listed under "Absolute Maximums Rating" may cause permanent damage to the device. These are stress rating
only; functional operation beyond the "Operation Conditions" is not recommended and extended exposure beyond the "Operation
Conditions" may effect device reliability.
RECOMMENDED OPERATING CONDITIONS
PARAMETER RANGE UNITS
Output Voltage Range -1.3 to -27 VDC
Case Operating Temperature Range -55 to +125 °C
ELECTRICAL PERFORMANCE CHARACTERISTICS 1/
PARAMETER SYM CONDITIONS (P PMAXMIN MAX UNITS
Reference Voltage 4/VREF 3V < (VIN - VOUT) < VDIFF MAX, 10mA < IOUT < IMAX -1.200 -1.300 V
Line Regulation 2/, 4/3V < (VIN - VOUT) < 30V, - 0.05 %/V
Load Regulation 2/, 4/10mA < IOUT < IMAX, VOUT < 5V
10mA < IOUT < IMAX, VOUT > 5V -
-50
1.0 mV
%
Thermal Regulation IOUT = 1.5A, (VIN - VOUT) = 13.3V, 20ms Pulse, 20W,
TC = +25°C -0.02%/W
Ripple Rejection VOUT = -10V, f = 120Hz, CADJ = 10µF 66 - dB
Adjustment Pin Current 4/IADJ IOUT = 10mA, 3V < (VIN - VOUT) < 30V - 100 µA
Adjustment Pin Current
Change 4/IADJ 3V < (VIN - VOUT) < 30V, 10mA < IOUT < IMAX -5µA
Minimum Load Cur rent 3/ 4/IMIN (VIN - VOUT) = 30V - 5 mA
(VIN - VOUT) < 10V - 3
Current Limit 4/, 5/IMAX (VIN - VOUT) < 15V 1.5 - A
(VIN - VOUT) = 30V, TC = +25°C 0.24 -
Long Term Stability 3/TC = +125°C - 1 %
Thermal Resistance, each
Regulator
(Junction to Case) 3/JC -5°C/W
Notes:
1/ Unless otherwise specified, these specifications apply for, (Vin - Vout) = 5V, Iout = 0.5A and -55°C < Tc < +125°C.
2/ Regulation is measured at a constant junction temperature, using pulse testing with a low duty cycle. Changes in output voltage due to
heating effects are covered under the specification for thermal regulation. Measurements taken at the output lead must be adjusted for lead
resistance.
3/ Not tested. Shall be guaranteed to the spec ified limits.
4/ Specification derated to reflect High Dose Rate (1019 condition A) to 100krads(Si) and Low Dose Rate (1019 condition D) to
50krads(Si), @ +25°C.
5/ Pulsed @ < 10% duty cycle @ +25°C.